Catalytic oxidation plant 6,000 Nm³/hKopf Holding GmbH
katalytische Oxidationsanlage
Catalytic oxidation plant 6,000 Nm³/h
Kopf Holding GmbH
katalytische Oxidationsanlage
Year of construction
2011
Condition
Used
Location
Bad Wörishofen 

Machine data
- Machine type:
- Catalytic oxidation plant 6,000 Nm³/h
- Manufacturer:
- Kopf Holding GmbH
- Year of construction:
- 2011
- Condition:
- not inspected (used)
Price & Location
- Location:
- Messerschmittstraße 2, 86825 Bad Wörishofen, Deutschland

Call
Details about the offer
- Listing ID:
- A22510312
- Update:
- 07.08.2026
Description
Complete gas treatment and catalytic oxidation system with heat recovery – built in 2011
On behalf of our client, we offer a high-quality industrial gas treatment and catalytic oxidation system for sale.
The system was originally designed and built for the treatment of methane, hydrogen sulfide, and hydrocarbon-containing gas streams from a geothermal application. It is still fully assembled and can be inspected by appointment.
The system was taken out of service in 2015 in functional condition and subsequently decommissioned professionally. All components in contact with the process medium were emptied and cleaned. Since the decommissioning, the system has neither been operated nor regularly maintained.
Crodpfx Aezr T Dkjbxof
A current functional test has not been carried out. Before recommissioning, a technical inspection and, if necessary, the modernization of individual components – in particular, the control and automation technology – are required.
Technical data
Manufacturer: KOPF Holding GmbH (complete system)
Model: Customer-specific special system
Year of construction: 2011
Process air/exhaust gas flow rate: up to 6,000 Nm³/h
Methane conversion according to original design: 90%
Burner output: 250 kW
Waste heat utilization: up to approx. 370 kW thermal output
System scope
Vacuum degassing system
Hydrogen sulfide absorber
Vacuum compressor system
Water treatment
Catalytic oxidation system
Catalytic reactor up to 750 °C
Two-stage pre-filtration
Stainless steel main heat exchanger
Waste heat recovery heat exchanger
Gas burner
Frequency-controlled main fan
Dräger gas measurement technology
Siemens S7 control system with process visualization
Extensive measuring, control and safety technology
Documentation
Extensive original documents are available for the system, including:
Process description
Layout drawings
Piping and instrumentation diagrams (P&IDs)
Isometrics
Quotation and project documentation
The completeness of Ex certificates and pressure vessel documentation is currently being checked.
Condition
System completely assembled
Taken out of service in functional condition in 2015
Components in contact with the process medium emptied and cleaned
Not operated since decommissioning
Sale in current condition
Inspection possible by appointment
The system is particularly suitable for applications in gas treatment, methane oxidation, VOC/exhaust gas purification, biogas, landfill gas or comparable industrial processes.
Sale is on behalf of the client.
Technical data is provided to the best of our knowledge based on the available original documents. A current functional test has not been carried out. Errors, changes and prior sale are reserved.
The listing was translated automatically. Translation errors are possible.
On behalf of our client, we offer a high-quality industrial gas treatment and catalytic oxidation system for sale.
The system was originally designed and built for the treatment of methane, hydrogen sulfide, and hydrocarbon-containing gas streams from a geothermal application. It is still fully assembled and can be inspected by appointment.
The system was taken out of service in 2015 in functional condition and subsequently decommissioned professionally. All components in contact with the process medium were emptied and cleaned. Since the decommissioning, the system has neither been operated nor regularly maintained.
Crodpfx Aezr T Dkjbxof
A current functional test has not been carried out. Before recommissioning, a technical inspection and, if necessary, the modernization of individual components – in particular, the control and automation technology – are required.
Technical data
Manufacturer: KOPF Holding GmbH (complete system)
Model: Customer-specific special system
Year of construction: 2011
Process air/exhaust gas flow rate: up to 6,000 Nm³/h
Methane conversion according to original design: 90%
Burner output: 250 kW
Waste heat utilization: up to approx. 370 kW thermal output
System scope
Vacuum degassing system
Hydrogen sulfide absorber
Vacuum compressor system
Water treatment
Catalytic oxidation system
Catalytic reactor up to 750 °C
Two-stage pre-filtration
Stainless steel main heat exchanger
Waste heat recovery heat exchanger
Gas burner
Frequency-controlled main fan
Dräger gas measurement technology
Siemens S7 control system with process visualization
Extensive measuring, control and safety technology
Documentation
Extensive original documents are available for the system, including:
Process description
Layout drawings
Piping and instrumentation diagrams (P&IDs)
Isometrics
Quotation and project documentation
The completeness of Ex certificates and pressure vessel documentation is currently being checked.
Condition
System completely assembled
Taken out of service in functional condition in 2015
Components in contact with the process medium emptied and cleaned
Not operated since decommissioning
Sale in current condition
Inspection possible by appointment
The system is particularly suitable for applications in gas treatment, methane oxidation, VOC/exhaust gas purification, biogas, landfill gas or comparable industrial processes.
Sale is on behalf of the client.
Technical data is provided to the best of our knowledge based on the available original documents. A current functional test has not been carried out. Errors, changes and prior sale are reserved.
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2020
4 listings online
Send inquiry
Telephone & Fax
+49 8247 ... show