Betschart Swiss Trafo Core Test System KPA 15 Isolation Transformer Test Core Testing System
Keine Angabe KPA 15 Prüfanlage

ONO plus VAT
€2,100
Condition
Used
Location
Borken Germany
Betschart Swiss Trafo Core Test System KPA 15 Isolation Transformer Test Core Testing System Keine Angabe KPA 15 Prüfanlage
Betschart Swiss Trafo Core Test System KPA 15 Isolation Transformer Test Core Testing System Keine Angabe KPA 15 Prüfanlage
Betschart Swiss Trafo Core Test System KPA 15 Isolation Transformer Test Core Testing System Keine Angabe KPA 15 Prüfanlage
Betschart Swiss Trafo Core Test System KPA 15 Isolation Transformer Test Core Testing System Keine Angabe KPA 15 Prüfanlage
Betschart Swiss Trafo Core Test System KPA 15 Isolation Transformer Test Core Testing System Keine Angabe KPA 15 Prüfanlage
Betschart Swiss Trafo Core Test System KPA 15 Isolation Transformer Test Core Testing System Keine Angabe KPA 15 Prüfanlage
Betschart Swiss Trafo Core Test System KPA 15 Isolation Transformer Test Core Testing System Keine Angabe KPA 15 Prüfanlage
Betschart Swiss Trafo Core Test System KPA 15 Isolation Transformer Test Core Testing System Keine Angabe KPA 15 Prüfanlage
more Images
Keine Angabe KPA 15 Prüfanlage
Keine Angabe KPA 15 Prüfanlage
Keine Angabe KPA 15 Prüfanlage
Keine Angabe KPA 15 Prüfanlage
Keine Angabe KPA 15 Prüfanlage
Keine Angabe KPA 15 Prüfanlage
Keine Angabe KPA 15 Prüfanlage
Keine Angabe KPA 15 Prüfanlage

Price & Location

ONO plus VAT
€2,100
Location:
Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland Germany
Call

Details about the offer

Listing ID:
A4050120
Reference number:
20560
Update:
07.10.2026

Description

Betschart Swiss Transformer Core Testing System KPA 15
Function
The output voltage, which can be continuously adjusted manually using a rotary knob, is fed directly to the excitation coils of the test core.
Crodod Nxhkepfx Ai Sjh
This is intended to create a homogeneous electromagnetic field in the air gap of the test core, with which core material inserted into the air gap can be characterized.
The basic operation of the core testing system is performed via the switching and display elements on the front panel at the front of the test carriage.

Technical Data
Input voltage: 2 x 400 V – 50/60 Hz
Input current: 38.3 A maximum
Output voltage: 0 … 230 V
Output current: 65 A maximum
Measurements: Moving-coil voltmeter 0 … 500 V for input voltage
Moving-coil voltmeter 0 … 250 V for output voltage
Moving-coil ammeter 0 … 40/80 A for input current
Moving-coil ammeter 0 … 75/150 A for output current
Laboratory sockets for external voltage measurement, direct, 1:1
Circuit breaker, 2-pole, 63 A, characteristic B
Voltage measurement, output voltage
Current measurement, output current
Voltage measurement, input voltage
Current measurement, input current
Laboratory sockets for external current measurement, current transformer 50 A/5 A
Current measurement, current transformer 75 A/5 A, output side
Main and emergency stop switch

Manufacturer's price: 27,000 EUR gross

Matching adjustable transformers can be found in our shop.

You can find more articles – new and used – in our shop!
International shipping costs on request!

The listing was translated automatically. Translation errors are possible.

Seller

Last online: A week ago

Registered since: 2008

541 listings online

Call

Send inquiry

Countryus 
Germany
Austria
Switzerland
United States
United Kingdom
France
Belgium
Spain
Mexico
Italy
Netherlands
Poland
Russian Federation
Belarus
Ukraine
Estonia
Turkey
New Zealand
Ireland
Czech Republic
Denmark
Finland
Sweden
Norway
Luxembourg
Greece
Lithuania
Latvia
Iceland
Portugal
Brazil
Venezuela
Argentina
Hungary
Slovakia
Romania
Moldova
Slovenia
Serbia
Montenegro
Albania
Croatia
Bulgaria
Macedonia
Bosnia and Herzegovina
Israel
Egypt
Morocco
India
Indonesia
South Korea
Japan
Thailand
Malaysia
Vietnam
China (People's Republic of China)
Taiwan
Iran
Bangladesh
Note: Your inquiry will be forwarded to all sellers in this machine category. This allows you to receive a large number of offers.
The inquiry could not be sent. Please try again later.

Telephone & Fax

+49 2862 ... show
These listings may also fit your interest.
Listing
VACUUM CALIBRATION TANK LÜERS VT125-1-6 LÜERS VT 125-1-6
VACUUM CALIBRATION TANK LÜERS VT125-1-6 LÜERS VT 125-1-6
VACUUM CALIBRATION TANK LÜERS VT125-1-6 LÜERS VT 125-1-6
VACUUM CALIBRATION TANK LÜERS VT125-1-6 LÜERS VT 125-1-6
VACUUM CALIBRATION TANK LÜERS VT125-1-6 LÜERS VT 125-1-6
VACUUM CALIBRATION TANK LÜERS VT125-1-6 LÜERS VT 125-1-6
VACUUM CALIBRATION TANK LÜERS VT125-1-6 LÜERS VT 125-1-6
VACUUM CALIBRATION TANK LÜERS VT125-1-6 LÜERS VT 125-1-6
VACUUM CALIBRATION TANK LÜERS VT125-1-6 LÜERS VT 125-1-6
VACUUM CALIBRATION TANK LÜERS VT125-1-6 LÜERS VT 125-1-6
VACUUM CALIBRATION TANK LÜERS VT125-1-6 LÜERS VT 125-1-6
more images
Germany Bockhorn
6,938 km
VACUUM CALIBRATION TANK LÜERS VT125-1-6
LÜERSVT 125-1-6
Call
Listing
Self-levelling cross line laser Self-leveling cross line laser WÜRTH
more images
Germany Wiesbaden
6,914 km
Self-levelling cross line laser
Self-leveling cross line laserWÜRTH
Certified Dealer
Call
Listing
Linear Incremental Measuring System LS487 Heidenhain LS487
Linear Incremental Measuring System LS487 Heidenhain LS487
Linear Incremental Measuring System LS487 Heidenhain LS487
more images
Italy Oberkreuth
6,683 km
Linear Incremental Measuring System LS487
HeidenhainLS487
Call
Listing
Performance test console with transformer
Performance test console with transformer
Performance test console with transformer
Performance test console with transformer
Performance test console with transformer
Performance test console with transformer
more images
Germany Minden
6,869 km
Performance test console with transformer
Call