Used Mytron Mytron Temperature Cabinet T2240 Temperature Range –40°C To +100°C, 2240 Liters for sale (89,387)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Success:
Your message has been sent.
Listing
Borken
7,009 km
CTS climate test chamber CW-60/5.5, -60°C to +100°C, 5,500 liters (5.5 m³)
CTSKlimakammer CW -60/5,5
Call
Condition: used, CTS
CTS CW‑60/5.5 – Water-Cooled Climatic Test Chamber
The CW‑60/5.5 from CTS GmbH (Climatic Test Systems) is a medium-sized,
walk-in or drive-in climatic chamber for performing temperature
and humidity tests on multiple test specimens simultaneously.
Device Description
The climatic test chamber can be used to test the function or material properties of a test specimen
under temperature and humidity conditions.
The efficient air circulation with a correspondingly high air exchange rate guarantees
good heat transfer to the test specimen.
The air handling unit is located on the rear of the interior chamber.
The components are located in a separate frame behind the device and are easily accessible.
The control system is housed in a separate control cabinet.
The operating panel is integrated into the control cabinet door.
To dehumidify the test chamber, the chamber is equipped with a self-regenerating compressed air dryer.
The test chamber can be purged with fresh air using a fan.
Psdpfxjzizmno Airogu
Technical Performance Data:
Temperature Tests:
Temperature range: -60 °C to +100 °C
Temperature deviation: ±0.5 to 1 K over time
Temperature change rate: linear, depending on the test specimen
and with heat radiation, measured in the supply air
Heating: 2 K/min from -40 °C to +85 °C
Cooling: 2 K/min from +85 °C to -40 °C
Climatic Tests:
Temperature range: +10 °C to +90 °C
Humidity range: 10 % to 95 % relative humidity
in the dew point range: +5 °C to +89 °C
Temperature deviation: ± 0.5 K over time
Humidity deviation: ±1 to ±3 % RH over time
The technical data refers to an ambient temperature of +25 °C,
rated voltage 400 V, without test specimen, without radiation, and without additional equipment.
Dimensions:
Internal dimensions (test chamber / usable space):
Volume: approx. 5,500 liters (5.5 m³)
Internal dimensions (approx.): Height: 2300 mm, Width: 1600 mm, Depth: 1550 mm
External dimensions: Height: 2800 mm, Width: 2250 mm, Depth: 5000 mm
Operating Data:
Electrical connection: 400 V +6/-10%, 3/N, PE, 50 Hz
Rated power: 58.3 kW (incl. 5 sockets)
Rated current: 86.0 A
Protection class: IP 54
Technical Design:
Refrigeration unit:
water-cooled, low noise, semi-hermetic,
stepless power adjustment through electronic
monitoring and control system,
environmentally friendly refrigerant R 23 / R 404 A
Notes
Inspection possible by appointment (46325 Borken)
Shipping by freight forwarder possible – costs & organization on request
Scope of supply: (See image)
(Changes and errors in the technical data and specifications are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
CTS climate test chamber CW-60/5.5, -60°C to +100°C, 5,500 liters (5.5 m³)
CTSKlimakammer CW -60/5,5
Call
Condition: used, CTS
CTS CW‑60/5.5 – Water-Cooled Climate Test Chamber
The CW‑60/5.5 from CTS GmbH (Climatic Test Systems) is a medium-sized,
walk-in or drive-in climate chamber for conducting temperature
and humidity tests on multiple test specimens simultaneously.
Device Description
The climate test chamber can be used to test the function or material properties of a test specimen
under temperature and humidity conditions.
The good air circulation, with a correspondingly high volume of recirculated air, guarantees
good transfer to the test specimen.
Pedpfx Aiszizmberegu
The air handling unit is located at the rear of the interior.
The units are located behind the device in a separate frame and are easily accessible.
The control system is housed in a separate control cabinet.
The control panel is integrated into the control cabinet door.
To dehumidify the test chamber, the chamber is equipped with a self-regenerating compressed air dryer.
The test chamber can be purged with fresh air via a fan.
Technical Performance Data:
Temperature Tests:
Temperature range -60 °C to +100 °C
Temperature deviation ±0.5 to 1 K over time
Temperature change rate, linear with test specimen
and with heat radiation, measured in the supply air
Heating: 2 K/min from -40 °C to +85 °C
Cooling: 2 K/min from +85 °C to -40 °C
Climate Tests:
Temperature range +10 °C to +90 °C
Humidity range 10 % to 95 % relative humidity
in the dew point range +5°C to +89 °C
Temperature deviation ± 0.5 K over time
Humidity deviation ±1 - ±3 % r.h. over time
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400 V, without test specimen, without radiation, and without additional equipment.
Dimensions:
Internal dimensions (test chamber / usable space):
Volume: approx. 5,500 liters (5.5 m³)
Internal dimensions (approx.): Height: 2300 mm Width: 1600 mm Depth: 1550 mm
External dimensions: Height: 2800 mm Width: 2250 mm Depth: 5000 mm
Operating Data:
Electrical connection: 400 V +6/-10%, 3/N, PE, 50 Hz
Rated power: 58.3 kW (incl. 5 sockets)
Rated current: 86.0 A
Protection class IP 54
Technical Design:
Refrigeration unit
water-cooled, low-noise, semi-hermetic,
stepless power adjustment through electronic
monitoring and control system,
environmentally friendly refrigerant R 23 / R 404 A
Notes
Inspection possible by arrangement (46325 Borken)
Shipping by freight forwarder possible – costs & organization on request
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Espec climate chamber PHP-J3, temperature and humidity up to +100°C
EspecKlimakammer PHP-J3
Call
Condition: used, Espec
Pgjdpfx Aozgtahjirou
Type: PHP - J3
Technical data:
Air-cooled
Temperature and humidity range: Ambient temperature +10°C to +100°C / 40 to 98% relative humidity
Temperature fluctuation: ±0.3 K
Humidity fluctuation: ±2.5%
Internal volume: 398 liters
Dimensions:
Internal dimensions: Width 600 mm x Height 830 mm x Depth 800 mm
External dimensions: Width 1010 mm x Height 1690 mm x Depth 1273 mm
Mains voltage: 400 VAC 3-phase 50 Hz
Maximum current: 400 VAC 8.3 A
Weight: 335 kg
Scope of delivery: Espec climate testing chamber
For your peace of mind as a buyer, please note the following:
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refilling with refrigerant that complies with legal regulations
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Binder Incubator Model BD 115, 115 liters, 5°C to 100°C
BinderInkubator BD 115
Call
Condition: used, Binder
Type: BD 115
Key Features
Model BD 115 | Standard incubator with natural convection
Technical Data BD 115
External Dimensions:
Width (net) 835 mm Height (gross, including feet/castors) 705 mm Depth (net) 645 mm Depth (gross, including door handle and exhaust pipe) 750 mm
Wall Clearance (rear, minimum) 100 mm
Wall Clearance (side, minimum) 160 mm
Pgsdpfx Ajzgaicoirou
Exhaust Pipe, Outer Diameter 52 mm
Doors
Number of Doors 1
Internal Dimensions:
Width 600 mm Height 480 mm Depth 400 mm
Internal Volume 115 liters
Steam Chamber Volume 142 liters
Drawers
Number of Drawers 0
Maximum Number of Drawers 5
Maximum Load per Drawer 20 kg
Permissible Total Load 50 kg
Weight (empty) 61 kg
Temperature Data
Temperature Range, 5°C above ambient temperature to 100°C
Temporal Temperature Deviation
at 37°C ± 0.1 K
at 50°C ± 0.1 K
Spatial Temperature Deviation
at 37°C ± 0.4 K
at 50°C ± 0.8 K
Heating Time
to 37°C 70 minutes
to 50°C 90 minutes
Recovery Time after 30 sec door open
at 37°C 10 minutes
at 50°C 12 minutes
Electrical Data:
BD115-230V
IP 20
Rated Voltage (+/-10%) at 50 Hz mains frequency 230 V
Rated Voltage (+/-10%) at 60 Hz mains frequency 230 V
Type of Current 1N~
Rated Power 0.20 kW
Condition: used
Scope of Delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Weiss climate test chamber with humidity control, temperature range -42°C to +180°C, approx. 335 lit
WeissKlimaprüfschrank
Call
Condition: used, Weiss
Type: WK3-340/40
Weiss Climate Test Chamber, Air-Cooled
Temperature Testing
Volume: 335 liters
Test Chamber Dimensions:
Test Chamber Dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External Dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Minimum Temperature -42°C
Maximum Temperature +180°C
Temperature Change Rate, Cooling 4 K/min
Temperature Change Rate, Heating 3.2 K/min
Temperature Deviation, Over Time ± 0.1 to ± 0.5 K
Temperature Homogeneity, Spatially ± 0.5 to ±1.5 K
Climate Testing:
Temperature Range +10°C to +95°C
Dew Point Range -3°C to +94°C
Humidity Range 10 to 98% RH
Temperature Deviation, Over Time ± 0.1 to ± 0.3 K
Temperature Homogeneity, Spatially ± 0.5 to ± 1 K
Humidity Deviation, Over Time ± 1 to ± 3 % RH
Halogen Bulb 2 x 24V, 50W
Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated Power 4.1 kW Rated Current: 14 A
Refrigerant: R-404A
Weight: approx. 515 kg
For your peace of mind as a buyer, please note the following information!
The following steps are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See image)
Pgsdjziyygspfx Airju
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
CTS Temperature Test Chamber T-70/600/S Temperature -70°C to 180°C 600 liters
CTSTemperaturprüfschrank
Call
Condition: used, CTS
Type: T-70/600/S
Water-cooled temperature testing chamber
Control:
- 32-bit controller
- LCD control panel
- Digital display of setpoint and actual values
- Numerical input of setpoints
- Error messages in plain text
- RS 232 interface
- Free switching channels for external control of the test item
Technical performance data
Temperature tests:
Temperature range -70 °C to +180 °C
Temperature deviation ±0.1 to ±0.3 K over time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat radiation
approx. 2500 W at +20°C
approx. 2500 W at +0°C
approx. 1800 W at -40°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test item, without radiation, and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions height, approx. 850 mm, width, approx. 850 mm, depth, approx. 830 mm
External dimensions height, approx. 1900 mm, width, approx. 1120 mm, depth, approx. 1875 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 8.8 kW
Rated current 14.8 A
Protection class IP 22
Refrigerant: R404A / R23
Weight approx. 700 kg
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Psdpfezg Ty Iox Airegu
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Weiss climate test chamber with humidity control, temperature range -42°C to +180°C, approx. 335 lit
WeissKlimaprüfschrank
Call
Condition: used, Weiss
Type: WK3-340/40
Weiss Climate Test Chamber, Water-Cooled
(Refrigerant converted to R-452A)
Temperature Testing
Volume: 335 liters
Test Chamber Dimensions:
Test Chamber Dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External Dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Minimum Temperature: -42°C
Maximum Temperature: +180°C
Temperature Change Rate, Cooling: 4 K/min
Temperature Change Rate, Heating: 3.2 K/min
Temperature Deviation, Time: ± 0.1 to ± 0.5 K
Temperature Homogeneity, Spatial: ± 0.5 to ± 1.5 K
Climate Testing:
Temperature Range: +10°C to +95°C
Dew Point Range: -3°C to +94°C
Humidity Range: 10 to 98% RH
Temperature Deviation, Time: ± 0.1 to ± 0.3 K
Temperature Homogeneity, Spatial: ± 0.5 to ± 1 K
Humidity Deviation, Time: ± 1 to ± 3% RH
Pjdpfx Aiozgavvoregu
Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated Power: 4.1 kW, Rated Current: 14 A
Refrigerant: R-452A
Weight: Approx. 515 kg
For your safety as a buyer, please note the following information!
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of Delivery: (See image)
(Changes and errors in technical data are subject to change!)
We will be happy to answer any further questions you may have over the phone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Heraeus Vötsch temperature test chamber VTS 7033 -70°C to +180°C approx. 570 liters
Heraeus VötschHeraeus Vötsch
Call
Condition: used, Heraeus Vötsch
Type: VTS 7033
Vötsch temperature testing cabinet VTS 7033, water-cooled
Temperature range: -70°C to +180°C
Temporal temperature deviation: ± 0.5 K
Spatial temperature deviation: ± 1.5 K
Heating rate: 7.5 K/min
Pgodpfxjzd Sf Dj Airsu
Cooling rate: 6.5 K/min
Test chamber dimensions: Width 825 mm x Depth 800 mm x Height 870 mm
Housing dimensions: 1080 mm x 1710 mm x 1950 mm
Side feed-throughs: 12 cm and 13 cm
Voltage: 400V +6/-10%, 3/N, 50Hz
Rated power: 9.5 kW, Rated current: 22 A
Refrigerant: R404A / R23
Approx. 570 liters, Weight: 580 kg
For your peace of mind as a buyer, please note the following information:
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Vötsch Temperature Test Chamber VTS³ 7018-5, 190 liters, -70°C to +180°C
VötschTemperaturprüfschrank VTS³ 7018-5
Call
Condition: used, Vötsch
Type: VTS³ 7018-5
Temperature test cabinet, water-cooled
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 900 mm x Depth 1550 mm x Height 1850 mm
Temperature testing:
Temperature range: -70°C to +180°C
Temperature change rate: Heating 7.5 K/min
Temperature change rate: Cooling 7.5 K/min
Test chamber volume: 190 liters
Pgsdpfxszfg Uce Airou
Rated voltage: 400V
Rated current: 20 A
Rated power: 9 kW
Weight: approx. 540 kg
Refrigerant: R404A and R23
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
CTS Temperature Test Chamber T-70/600/S Temperature -70°C to 180°C 600 liters
CTSTemperaturprüfschrank
Call
Condition: used, CTS
Type: T-70/600/S
Water-cooled temperature testing chamber
Refrigerant: Converted to R-452A
Control:
- 32-bit controller
- LCD control panel
- Digital display of setpoint and actual values
- Numerical input of setpoints
- Error messages in plain text
- RS 232 interface
- Free switching channels for customer-specific test specimen control
Technical performance data
Temperature tests:
Temperature range -70 °C to +180 °C
Temperature deviation ±0.1 to ±0.3 K over time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat radiation
approx. 2500 W at +20°C
approx. 2500 W at +0°C
approx. 1800 W at -40°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400 V, without test specimen, without radiation, and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions height, approx. 850 mm, width, approx. 850 mm, depth, approx. 830 mm
External dimensions height, approx. 1900 mm, width, approx. 1120 mm, depth, approx. 1875 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 8.8 kW
Rated current 14.8 A
Protection class IP 22
Weight approx. 700 kg
Refrigerant: R-452A / R23
Weight: 700 kg
For your safety as a buyer, please note the following information:
Pgsdpfx Aiozh D E Rorsu
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Vötsch Temperature Chamber VT 7011 -70°C to +180°C 110 liters (5717)
VötschVT 7011
Call
Condition: used, Vötsch
Type: VT 7011
Heraeus Vötsch temperature control cabinet, water-cooled
Psdpfjzdtd Iex Airegu
Test chamber volume: 110 liters
Test chamber dimensions: Width 560 mm, Depth 350 mm, Height 630 mm
External dimensions: Width 850 mm, Depth 1030 mm, Height 1640 mm
Temperature range: -70°C to +180°C
Temporal temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1.5 K
Temperature gradient: 1 to 3 K
Cooling rate: 3.2 K/min
Heating rate: 3.5 K/min
Refrigerant: R-404 A / R 23
Voltage: 1/N/PE AC 230V ±10%, 50Hz
Rated power: 1.8 kW
Rated current: 12 A
For your security as a buyer, please note the following:
The following steps are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data and information are subject to change!)
We are happy to answer any further questions you may have by phone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Weiss Temperature Test Chamber TempEvent T/1000/70/5 -70°C to +180°C 1000 liters
WeissTempEvent T/1000/70/5
Call
Condition: used, Weiss
Temperature test chamber TempEvent T/1000/70/5,
water-cooled, 1000 liters, year of manufacture 2020,
operating hours 6126 h.
Description:
For sale is a high-quality climate test chamber from Vötsch Industrietechnik
(Weiss Technik), model TempEvent T/1000/70/5.
The device is used to simulate temperature conditions and is ideal for:
Material tests
Electronics tests
Environmental and aging tests
Quality and endurance tests
The chamber can generate very low temperatures up to approx. -70 °C as well as high temperatures up to +180 °C
and change these at a defined rate (temperature ramps).
Precise control allows reproducible test conditions to be achieved.
Operation is conveniently carried out via an integrated touch panel.
Special features:
Fast temperature changes (up to 5 K/min)
Uniform temperature distribution in the test chamber
Water-cooled system
Industrial standard – robust design
Maintenance indicator and operating hour counter available
Technical data:
Model: TempEvent T/1000/70/5
Temperature range: approx. -70 °C to +180 °C
Temperature change: up to 5 K/min
High precision & stability:
Temporal temperature deviation: ±0.1 to ±0.5 K
→ very stable temperature over time
Spatial deviation: ±0.5 to ±1.0 K
Temperature gradient: ≤ 2.0 K
This makes the chamber ideal for demanding testing processes
with high repeatability
Test chamber: approx. 950 × 1100 × 950 mm (W × H × D)
External dimensions: approx. 2000 × 1415 × 2030 mm (W × H × D)
Side opening 50 cm / 125 cm
Electrical data:
400 V / 3~ / 50 Hz
Rated current: approx. 34 A
Power: approx. 21 kW
Refrigerant:
R449A (approx. 2.9 kg)
R23 (approx. 1.3 kg)
Weight: approx. 1200 kg
For your safety as a buyer, the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerants
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
Pgsdpfx Ajyxm Ulsirsu
We will be happy to answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Weiss Temperature Test Chamber WT3-600/70/5, 600 liters, -70°C to +180°C
WeissWT3- 600/70/5
Call
Condition: used, Weiss
Type: WT3-600/70/5
Weiss temperature testing cabinet WT3-600/70/5
water-cooled version
with S!MCON / 32 control system and touch panel
Control panel "Touch Panel"
By simply touching the function symbols on the "Touch Panel" control panel, all control and operating commands can be activated.
Adjustable feet
To compensate for uneven floors and to ensure sufficient ventilation of the machine, the testing cabinet is equipped with adjustable feet.
Feedthroughs
The testing cabinet is equipped with feedthroughs on the right and left sides.
These allow measuring cables and testing equipment to be routed into the test chamber.
Feedthroughs installed as standard:
R1: DN 125 mm
L1: DN 50 mm
Test chamber volume: approx. 600 liters
External dimensions including hinges and door lock:
Height: 1995 mm, Width: 1090 mm, Depth: 1660 mm
External dimensions excluding hinges and door lock:
Height: 1995 mm, Width: 1000 mm, Depth: 1660 mm
Internal dimensions:
Height: 950 mm, Width: 800 mm, Depth: 800 mm
Data for temperature tests:
Temperature range: -70 °C to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Temperature deviation spatially: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5):
Heating: 7.5 K/min
Cooling: 7.5 K/min
Maximum heat compensation: 2500 W
Data for operation:
Test chamber lighting: Halogen bulb 2 x 24V, 50W
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: approx. 23 A
Rated power: approx. 13 kW
On-site fuse protection: 16 A slow-blow
Sound pressure level:
Measured at a distance of 1 m in front / 1 m height: approx. 58 dB(A)
Refrigerant:
R-404A / R23
Weight: approx. 620 kg
For your safety as a buyer, here is the following information:
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
Pgodey Nibpspfx Airou
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,016 km
Vötsch VT 7100 temperature test chamber -70°C to +180°C, test chamber volume 990 liters
VötschVT 7100
Call
Condition: used, Vötsch VT 7100 Temperature Test Chamber -70°C to +180°C
Features:
• Touch panel
• Microprocessor-controlled monitoring and control system MINCON/32
• Extremely low noise level
• Protection of test specimens through independent temperature measurement
• Maintenance-friendly design
• Door with window (including test chamber lighting)
• Aerodynamically optimized air flow
Manufacturer: Weiss Vötsch
Type: Temperature test chamber
Model: VT 7100
Control system: MINCON / 32
Operating unit: Touch panel
Test chamber volume: 990 l
Temperature range: -70 °C to +180 °C
Temporal temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.1 to ±0.5 K
Temperature change rate (cooling): 2.2 K/min
Temperature change rate (heating): 3 K/min
Electrical connection: 3/N/PE AC, 400 V ±10 %, 50 Hz
Rated power: 13.8 kW
Rated current: 29 A
Weight: 910 kg
Dimensions of the test chamber:
Width: 1100 mm
Depth: 950 mm
Height: 950 mm
Pgsdpsph Uzxofx Airsu
External dimensions:
Width: 1390 mm
Depth: 1855 mm
Height: 1995 mm
You can find more items – new and used – in our shop! International shipping costs available upon request!
Success:
Your message has been sent.
Listing
Borken
7,016 km
Weiss Temperature Test Chamber WT 11-18 KWP 500/40, 500 liters, -40°C to +180°C
WeissKWP 500/40
Call
Condition: used, Weiss temperature testing cabinet WT 11-18 KWP 500/40
Spring, summer, autumn, and winter – your products must be able to withstand different temperatures during manufacturing, transport, storage, and use. The temperature testing cabinets from Weiss Technik help you test the influence of thermal conditions on the properties, function, and lifespan of your products.
Manufacturer: Weiss Technik
Type: KWP 500/40 - 180 DU
Designation: WT 11-18
Type: Temperature testing cabinet
Test chamber volume: 500 liters
Temperature range: -40°C to +180°C
External dimensions: 110 cm wide, 173 cm deep, and 204 cm high
Internal dimensions: 80 cm wide, 85 cm deep, and 85 cm high
Pressure: 25 bar
Pgjdpsh Izh Iofx Airju
Voltage: 380 V
Frequency: 50 Hz
kVA: 4.7
Refrigerant: R 502
Year of manufacture: 1990
Condition: used
Complete factory closure,
large selection of storage platforms, pallet racking, shelving units, paternoster lifts.
High-quality industrial machines, lathes, grinding machines, hand tools.
More items – new and used – can be found in our shop!
International shipping costs on request!
Success:
Your message has been sent.
Listing
Borken
7,009 km
Vötsch VT 7012 S2 Temperature Shock Test Chamber -80°C to +220°C, 125 Liter Climate Chamber
VötschSchocktestkammer
Call
Condition: used, Vötsch
Temperature Shock Chamber / Shock Test Chamber
Vötsch VT 7012 S2 Temperature Shock Chamber
Two-chamber system for rapid temperature changes from -80 °C to +220 °C
Water-cooled version with a mobile cart and programmable controller
For sale is a used temperature shock chamber from the manufacturer Vötsch Industrietechnik GmbH.
The system is suitable for temperature shock and temperature cycling tests,
environmental simulation, material testing, quality assurance,
electronics and component testing, as well as development, aging, and stress tests.
The test chamber operates with a hot and a cold chamber.
The test specimen is moved between the two temperature zones using a mobile cart.
The system has an observation window,
test chamber lighting, and a programmable controller.
Technical data:
Manufacturer: Vötsch Industrietechnik GmbH
Type: VT 7012 S2
Device type: Temperature shock chamber / Shock test chamber
Version: Two-chamber system / water-cooled
Temperature range, hot chamber: +50 °C to +220 °C
Temperature range, cold chamber: -80 °C to +70 °C
Temperature deviation (time): ±1.0 K
Temperature deviation (spatial): ±2.0 K
Heating rate, hot chamber: approx. 11.0 K/min
Cooling rate, cold chamber: approx. 3 K/min
Heating rate, cold chamber: approx. 2.0 K/min
Test chamber volume: approx. 125 liters
Test chamber dimensions: 470 × 410 × 650 mm (W × H × D)
Max. load capacity, mobile cart: 40 kg
Max. total load capacity, mobile cart: 20 kg
Pipe connection: Ø 67 mm
Refrigerant 1: R404A
Refrigerant quantity: 2.5 kg
Max. low pressure: 22.5 bar g
Max. high pressure: 25 bar g
Refrigerant 2: R23
Refrigerant quantity: 1.1 kg
Max. low pressure: 22.5 bar g
Max. high pressure: 25 bar g
Standby pressure: 13 bar g
Power supply: 3/N/PE AC 400 V ±10 % / 50 Hz
Rated power: 10 kW
Rated current: 25 A
On-site fuse: 32 A slow-blow
Compressor power: 2 × 3 kW
Cooling water supply:
Inlet pressure: 3 to 6 bar
Differential pressure, inlet and outlet: ≥2.5 bar
Water connection: R 3/4" internal thread
Dimensions:
External dimensions: approx. 975 × 2,115 × 1,675 mm (W × D × H)
Weight: approx. 1,000 kg
Psdpfxoz Ehrgs Airegu
Equipment:
Two-chamber temperature shock system
Hot chamber
Cold chamber
Motor-driven mobile cart
Programmable controller
Manual operation
Automatic operation
Shock test operation
Observation window
Test chamber lighting
Pipe connection Ø 67 mm
Water-cooled refrigeration system
Signal light
Control terminal
Accessories as shown in the pictures
Application areas:
Temperature shock testing
Temperature cycling testing
Environmental simulation
Material testing
Electronics testing
Component testing
Assembly testing
Quality assurance
Research and development
Service life testing
Aging and stress tests
Condition:
Used
Optical condition as shown in the pictures
Scope of delivery:
1x Vötsch VT 7012 S2 Temperature Shock Chamber
Control terminal
Original operating manual
Accessories as shown in the pictures
Important note:
For the safety of our customers, the following work will be carried out on the offered testing and climate systems in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. Documented test run after successful inspection
The table or other items not explicitly mentioned in the photos are not part of the sale.
Shipping or forwarding possible.
Subject to changes, errors and prior sale.
We are happy to answer further questions by phone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Vötsch VT 7012 S2 temperature shock test chamber -74°C to +220°C, 125 liter climate chamber
VötschVT 7012 S2
Call
Condition: used, Vötsch
Temperature shock test chamber / Shock test chamber
Vötsch VT 7012 S2 temperature shock test chamber
Two-chamber system for rapid temperature changes from -74 °C to +220 °C
Water-cooled version with mobile cart and programmable control
For sale is a used temperature shock test chamber
from the manufacturer Vötsch Industrietechnik GmbH.
The system is suitable for temperature shock and temperature cycling tests,
environmental simulation, material testing, quality assurance,
electronics and component testing
as well as development, aging and stress tests.
The test chamber operates with a hot and a cold chamber.
The test specimen is moved between the two temperature zones via a mobile cart.
The system features an observation window,
test chamber lighting and programmable control.
Technical data:
Manufacturer: Vötsch Industrietechnik GmbH
Type: VT 7012 S2
Equipment type: Temperature shock test chamber / Shock test chamber
Version: Two-chamber system / water-cooled
Temperature range, hot chamber: +50 °C to +220 °C
Temperature range, cold chamber: -74 °C to +70 °C
Temperature deviation over time: ±1.0 K
Temperature deviation spatially: ±2.0 K
Heating rate, hot chamber: approx. 11.0 K/min
Cooling rate, cold chamber: approx. 3 K/min
Heating rate, cold chamber: approx. 2.0 K/min
Test chamber volume: approx. 125 liters
Test chamber dimensions: 470 × 410 × 650 mm (W × H × D)
Max. load capacity, mobile cart: 40 kg
Max. total load capacity, mobile cart: 20 kg
Pipe passage: Ø 67 mm
Refrigerant 1: R404A
Refrigerant quantity: 2.5 kg
Max. low pressure: 22.5 bar g
Max. high pressure: 25 bar g
Refrigerant 2: R23
Psdpsz Ehuujfx Airegu
Refrigerant quantity: 1.1 kg
Max. low pressure: 22.5 bar g
Max. high pressure: 25 bar g
Standby pressure: 13 bar g
Power connection: 3/N/PE AC 400 V ±10 % / 50 Hz
Rated power: 10 kW
Rated current: 25 A
On-site fuse: 32 A slow-blow
Compressor power: 2 × 3 kW
Cooling water supply:
Inlet pressure: 3 to 6 bar
Differential pressure, inlet and outlet: ≥2.5 bar
Water connection: R 3/4" internal thread
Dimensions:
External dimensions: approx. 975 × 2,115 × 1,675 mm (W × D × H)
Weight: approx. 1,000 kg
Equipment:
Two-chamber temperature shock system
Hot chamber
Cold chamber
Motorized mobile cart
Programmable control
Manual operation
Automatic operation
Shock test operation
Observation window
Test chamber lighting
Pipe passage Ø 67 mm
Water-cooled refrigeration unit
Signal light
Operator terminal
Accessories according to images
Application areas:
Temperature shock testing
Temperature cycling testing
Environmental simulation
Material testing
Electronics testing
Component testing
Assembly testing
Quality assurance
Research and development
Service life testing
Aging and stress tests
Condition:
Used
Optical condition according to images
Scope of delivery:
1x Vötsch VT 7012 S2 temperature shock test chamber
Operator terminal
Original operating manual
Accessories according to images
Important note:
For the safety of our customers, the following work will be carried out on the offered test and climate systems in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant if necessary
3. Leak test with certificate
4. Documented test run after successful inspection
The table shown in the photos or any other items not expressly mentioned are not included in the sale.
Shipping or freight forwarding possible.
Subject to changes, errors and prior sale.
We wi
Success:
Your message has been sent.
Listing
Borken
7,009 km
Espec temperature test chamber EGN28-6CWL, temperature range -70 to +180°C
EspecTemperaturprüfschrank
Call
Condition: used, Espec
Type: EGN28-6CWL
Espec, water-cooled temperature chamber
Temperature test chamber, N series
Power supply:
AC 400 V, 3-phase, 50/60 Hz, 38 A
Temperature range: -70 to +180°C
Temperature change rate:
Heating: 10 °K/min
Cooling: 5.5 °K/min
Internal dimensions (W x H x D) in mm: 1000 x 1000 x 800
External dimensions (W x H x D) in mm: 1205 x 1920 x 2159
Usable volume: 800 liters
Refrigerant: R-404A
Refrigerant: R-508A
Weight: approx. 695 kg
For your safety as a buyer, please note the following:
The following steps will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Pgsdpfxozg Tyne Airou
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Vötsch temperature test chamber VTS³ 7027-25, 270 liters, -72°C to +180°C
VötschTemperaturprüfschrank
Call
Condition: used, Vötsch
Type: VTS³ 7027-25
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
Performance Data:
With a temperature change rate of 25 K/min
Test chamber dimensions: Height 750 mm, Width 580 mm, Depth 615 mm
External dimensions: Height 1775 mm, Width 780 mm, Depth 1895 mm
Temperature range: -72°C to +180°C
Temperature deviation (temporal): ± 0.1 to ± 0.5
Temperature homogeneity (spatial): ± 0.5 to ± 2.0
Temperature change rate (cooling): 25 K/min
Temperature change rate (heating): 25 K/min
Heat compensation at -20 °C: 8000 W
Heat compensation at +20 °C: 8000 W
Test volume: 270 liters
2x side feedthroughs, Ø 125 cm
1x side feedthrough, Ø 50 cm
Chamber is water-cooled
Test chamber lighting:
LED strip 24 V, 6.8 W / 2x halogen bulb 24 V, 50 W
Electrical connection:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 26 kW
Rated current: 44 A
Refrigerant: R-452A and R-23
Weight: approx. 980 kg
For your safety as a buyer, please note the following information:
The following steps are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerants
3. Leak test with certificate
Pgsdpfx Aijzg Eygjrsu
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by phone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Weiss WT-1300/70/15 Temperature Test Chamber 1300 liters -70°C to +180°C 15 K/min
WeissWT-1300/70/15
Call
Condition: used, Weiss
Type: WT-1300/70/15
Weiss temperature testing chamber, water-cooled
with touch panel control
Data for temperature tests:
Temperature range: -70 °C to +180 °C
Test chamber volume: approx. 1340 liters
Temperature change rate:
Heating: 15 K/min
Cooling: 10 K/min
Temperature deviation over time in the center of the usable space:
± 0.1 to ± 0.5 K
Temperature homogeneity spatially:
± 0.5 to ± 2 K
Test chamber dimensions:
Height: 920 mm, Width: 1100 mm, Depth: 1330 mm
External dimensions:
Height: approx. 2050 mm, Width: approx. 1300 mm, Depth: approx. 3200 mm
Permissible test item weight:
Total load on the test chamber floor: 150 kg
Load per insert shelf: 50 kg
Data according to the nameplate:
Manufacturer: Weiss Umwelttechnik GmbH
Type: WT-1300/70/15
Data for operation:
Pgsdpfx Asza Dv Ieirsu
Rated voltage: 3/N/PE AC 400 V ±10% 50 Hz
Rated current: 63 A
Rated power: 44 kW
Refrigerant:
R404A: 14.0 kg
R23: 5.4 kg
Maximum permissible pressures:
R404A LP max.: 18 bar
R404A HP max.: 25 bar
R23 LP max.: 19 bar
R23 HP max.: 25 bar
Standby pressure: 18.5 bar
Equipment:
Touch panel control
Stainless steel test chamber
Multiple insertion levels
Side access
Heated door seal
Water-cooled refrigeration unit
CEE connector
CE marking available
Weight: approx. 1500 kg
For the safety of our customers, the following work will be carried out on the offered climate chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. Documented test run after successful inspection
Condition: used
Scope of delivery: (See image)
Shipping or freight forwarding possible.
Subject to changes, errors and prior sale.
We will gladly answer any further questions by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
CTS Temperature Shock Test Chamber TSS-70/130 Hot: +50°C to +200°C Cold: -80°C to +100°C 130L
CTSTSS-70/130
Call
Condition: used, CTS
Type: TSS-70/130
Water-cooled cooling unit
For sale is a high-quality temperature shock test chamber from CTS
(Clima Temperatur Systeme), model TSS-70/130.
The device is used for performing temperature shock tests
Podpsy Hkd Hsfx Airegu
and is typically used in industry, research, and quality assurance.
Application areas:
Material tests
Aging tests
Electronics and component tests
Temperature shock and cyclic temperature tests
Technical data:
Type: TSS-70/130
Test volume: 130 liters
Temperature range:
Hot chamber: +50°C to +200°C
Cold chamber: -80°C to +100°C
Heating rate: approx. 6 K/min from room temperature to +180°C
Cooling rate: approx. 4 K/min from room temperature to -60°C
Temperature deviation:
±1 K in time
±2 K spatially
Temperature change rate:
max. 100 K/min on average for shock test tests
without heat input
Temperature adjustment rate:
≤ 15 min in the range of -65°C to +200°C
with 10 kg of ICs
Cycle time:
< 10 seconds
Electrical data:
Connection: 400 V, 3/N, 50 Hz
Rated power: approx. 17.2 kW
Rated current: approx. 29 A
On-site protection: 32 A slow-blow fuse
Connection: Cekon 32
Refrigeration system:
Refrigerant: R404A / R23
water-cooled, low-noise, fully hermetic
Equipment / Features:
CTS control panel
Microprocessor-controlled control and monitoring system
Program operation
up to 100 test programs possible
digital setpoint and actual value display
RS232 interface
2 free switching channels for on-site control of the test specimen
Fault message on potential-free contact
Load up to 30 V DC, 2 A
EMC tested
Technical design:
Hot and cold chamber
Mobile frame with lifting spindle drive
Test chamber / mobile frame made of stainless steel, material no. 1.4301
Insert basket made of stainless steel wire
Pipe passage NW 50 with sealing plug
Compressed air connection 1/4" AG
Condensate drain non-pressurized R 1/2" internal thread
Safety door lock
lockable door with window
Dimensions according to installation diagram:
External dimensions approx.: 2335 x 940 x 1820 mm
Loading dimension approx.: 1990 x 940 x 1652 mm
Test chamber dimensions: height approx. 410 mm
Width approx. 480 mm, depth approx. 660 mm
Window: 300 x 300 mm
Other data:
Protection class: IP 22
Sound pressure level: < 60 dB(A)
Weight: approx. 950 kg
Average consumption during test cycle: approx. 8 kWh
For your safety as a buyer, the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: see pictures
(Changes and errors in technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
Trust Seal
Dealers certified through Machineseeker

Success:
Your message has been sent.
Listing
Borken
7,009 km
Weiss temperature test chamber WT-600/70/5 -70°C to +180°C, 600 liters
WeissWT-600/70
Call
Condition: used, Weiss
Weiss Umwelttechnik WT-600/70/5
Temperature testing chamber -70°C to +180°C
Water-cooled
Pgjdpfx Asy At Sxoirsu
For sale is a used temperature testing chamber from Weiss Umwelttechnik.
The unit is functional and has been inspected.
This is a temperature testing device without a humidity function.
The chamber is suitable for testing components, electronics, and materials
under extreme temperature conditions.
It is often used in industry, development, and quality assurance.
The temperature range is from -70°C to +180°C.
The unit can heat up and cool down quickly and operates with forced air circulation
for uniform temperature distribution inside.
Cable feedthroughs with 125 mm and 50 mm are available.
Technical data:
Test chamber designation: WT-600/70/5
Cold/heat operation -70°C to 180°C
Temperature change per unit of time
Cooling: approx. 6 K/min
Heating: approx. 6 K/min
External dimensions with hinges and door lock
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock
Height 1995 mm, Width 1000 mm, Depth 1660 mm
Internal dimensions:
Height 950 mm, Width 800 mm, Depth 800 mm
Test chamber volume: approx. 600 liters
3/N/PE AC 400V ±10% 50Hz
Rated power: 16 kW
Rated current: 19 A
Fuse (customer-supplied): 29 A slow-blow
Permissible test item weight
Total load capacity of the shelf supports: 80 kg
Test chamber floor: 80 kg, Insert shelf: 40 kg
Refrigerant: R 404A/R23
Weight: 675 kg
For your peace of mind as a buyer, the following information!
The following steps are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After a successful inspection, the chambers are subjected to a test run, which is monitored with calibrated instruments.
Condition: used
Scope of delivery: (See image)
(Changes and errors in technical data and information are subject to change!)
We will gladly answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Vötsch Climate Test Chamber VC 7018 Temperature Range -70°C to +180°C with Humidity Control, 190 Lit
VötschKlimaprüfschrank
Call
Condition: used, Vötsch
Type: VC 7018
Vötsch Climate Testing Chamber VC 7018, Water-Cooled
Control Panel: “Touch Panel”
All control and operating commands can be initiated by simply touching the function symbols on the “Touch Panel” control panel.
Adjustable Feet
To compensate for uneven floors and to ensure sufficient ventilation of the machine, the testing chamber is equipped with adjustable feet.
Feedthroughs
The testing chamber is equipped with feedthroughs on the right and left sides.
These allow measuring cables and testing equipment to be routed into the testing chamber.
Pgjdpfxezh Huho Airou
Feedthroughs installed as standard:
R1: 125 mm
L1: 50 mm
Testing chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Performance data for temperature tests:
Temperature range: -70°C to +180°C
Temporal: ±0.1 to ±0.5 K
Spatial: ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min.
Cooling: 2.3 K/min.
Performance data for climate tests:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% RH
Temporal temperature deviation in the center of the usable space: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Temporal humidity deviation in the center of the usable space: ±1 to ±3 % RH
Electrical connection:
Rated voltage: 3/N/PE AC 400V ±10 50Hz
Rated power: 5.9 kW
Rated current: 12.0 A
Connection cable: 3.5 m
Fuse: 16 A, slow-blow, provided on site
Refrigerant: R-404A and R-23
Testing chamber volume: approx. 190 liters
Weight: approx. 460 kg net
For your safety as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We will gladly answer any further questions you may have over the phone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Weiss Climate Test Chamber WK3-340/70 with humidity control, temperature range -72°C to +180°C, appr
WeissKlimaprüfschrank
Call
Condition: used, Weiss
Type: WK3-340/70
Weiss Climate Testing Chamber, Air-Cooled
Control Panel »Touch Panel«
All control and operating commands can be initiated by simply touching the function symbols on the »Touch Panel« control panel.
Adjustable Feet
To compensate for uneven floors and ensure sufficient ventilation of the machine section, the testing chamber is equipped with adjustable feet.
Feedthroughs
The testing chamber is equipped with feedthroughs on the right and left sides.
These allow measuring cables and testing equipment to be routed into the test chamber.
Feedthrough installed as standard
R1: 125 mm
L1: 85 mm
Volume: 335 liters
Test chamber dimensions:
Test chamber dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Data for temperature tests:
Minimum temperature -72°C
Maximum temperature +180°C
Temperature deviation, over time ± 0.1 to ± 0.5 K
Temperature homogeneity, spatially ± 0.5 to ± 1.5 K
Temperature change rate, cooling 3 K/min
Temperature change rate, heating 3 K/min
Data for climate tests:
Temperature range +10°C to +95°C
Pjdpfx Ajziiwueirsgu
Dew point range -3°C to +94°C
Humidity range 10 to 98% RH
Temperature deviation, over time ± 0.1 to ± 0.3 K
Temperature homogeneity, spatially ± 0.5 to ± 1 K
Humidity deviation, over time ± 1 to ± 3% RH
Data for operation:
Test chamber lighting: Halogen bulb 2 x 24V, 50W
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 16 A Rated power 4.9 kW
Fuse, to be provided by the customer: 16 A slow-blow
Refrigerant: R-452A/R23
Weight Approx. 585 kg
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are subject to change!)
We will be happy to answer any further questions you may have over the phone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Temperature test chamber 1000 liters
CTST-55/1000 Li -50°C bis 100°C
Call
Condition: excellent (used), CTS
Temperature testing chamber T-55/1000 Li, water-cooled
Temperature range: -50°C to +100°C
Rated voltage: 400V 3/N 50Hz
Rated power: 9.5 kW
Rated current: 18 A
Compressor: TFH2511Z / TFH2511Z, refrigerant R404A/R23
The type designation of the CTS chamber series is as follows:
e.g., Type T -55/1000/Li
1) T means: Temperature
2) -55 means: lower temperature -55°C
3) 1000 means: 1000-liter test chamber volume
4) Li means: special equipment for
Podpjzg Ty Usfx Airegu
testing with lithium-ion batteries
Control:
32-bit controller
LCD control panel
Digital display of setpoint and actual values
Numerical input of setpoints
Error messages in plain text
Ethernet interface
RS 232 interface
Free switching channels for customer-specific
control of the test item
Test chamber lighting:
energy-efficient, bright LED light strip mounted on the door
Insert rack:
Stainless steel, support surface 970 x 980 mm
Load per rack max. 35 kg
Total load with max. rack load 100 kg
1a Conduit NW50
1b Conduit 2x NW125
1c Conduit 2x Rp 314°
for Minimax
Technical performance data:
Temperature tests:
Temperature range -50°C to +100°C
Temperature deviation ≤ ±0.3 K over time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Thermal compensation
approx. 4000 W at +20°C
approx. 2200 W at -40°C
The technical data refer to an ambient temperature of +25°C,
rated voltage 400V, without test item, without thermal compensation and without additional equipment.
Options can affect the performance data.
Dimensions:
Test volume 1000 liters
Test chamber dimensions Height, approx. 1000 mm, Width, approx. 860 mm, Depth, approx. 1100 mm
External dimensions Height, approx. 1950 mm, Width, approx. 1270 mm, Depth, approx. 1900 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated current 18 A
Rated power 9.5 kW
Protection class IP 54
Sound pressure level < 58 dB(A)
(measured according to DIN EN ISO 3744
at a distance of 1 m from the front)
Weight approx. 1000 kg
Heat dissipation to the installation room 10.4 kW
Refrigeration unit:
water-cooled, low-noise, fully hermetic
stepless power adjustment by electronic monitoring and control system,
environmentally friendly refrigerant R404A/R23
For your safety as a buyer, the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerants
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and information are subject to change!)
We will gladly answer any further questions you may have on the phone.
We make it easier for you to find: "mytron mytron temperature cabinet t2240 temperature range –40°c to +100°c, 2240 liters"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you

































































































































































































