Used Vötsch Emissions Test Chamber for sale (15,690)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
7,009 km
Emissions test chamber
WEISSWT 5,1'/ + 18-45
Call
Condition: excellent (used), Weiss
Here, we offer a Weiss emission test chamber.
Mini - SHED for diurnal loss measurements
Test chamber dimensions: Width 1600 mm x Depth 2140 mm x Height 2150 (usable 1600) mm
Housing dimensions: Width 1760 mm x Depth 3100 mm x Height 2790 mm
Maximum floor load: 250 kg
Itodpszd Slkjfx Acreh
Operating temperature range: +18 °C ... +45 °C (at higher temperatures, SHED operation is only possible without a Tedlar bag)
Temperature range: +18 °C ... +45 °C
Temperature stability: ≤ ±1 K (over time)
Temperature change rate (heating and cooling): approx. 0.5 K/min, without test specimen
Duct connection (air inlet and outlet): ∅ 80 mm, in the rear wall of the chamber
Shut-off valve, gas-tight (air inlet and outlet): ∅ 80 mm, gas-tight, pneumatic operation; scope of supply: connecting flange of the shut-off valve
Cooling water consumption: approx. 0.8 m3/h
Voltage: 230/400 V; 3-phase + N + PE; 50 Hz
Rated power: 4.1 kW Rated current: 14.0 A
Weight: approx. 2500 kg
Type: WT 5.1'/ + 18-45
Condition: used
Sale from our location
Scope of supply: (Only the Weiss emission test chamber WT 5.1'/ + 18-45 Mini-SHED)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
Listing
Borken
7,013 km
Vötsch climatic test chamber Fitotron HGC1014
Vötsch Klimaprüfschrank 5°C bis +45°Fitotron HGC 1014 V Schrank 3 mit Bel.
Call
Condition: excellent (used), functionality: fully functional, Year of construction: 2012, Fitotron® Modular Plant Growth Chambers, Type HGC 1014 V, including HQI-T and Krypton Lighting Module
Temperature range +5°C - +45°C for temperature testing
Test chamber volume approx. 1300 l
Simpac Control System
Network Connection
USB Connection
The Fitotron® HGC series plant growth chambers are based on a modular design. Individual modules can be added or replaced as needed. This allows them to be adapted to different applications. They are suitable for plants with high light requirements, such as wheat, corn, cotton, rice, and C4 plants.
Lighting HQI-BT-400 W/D and 100 W,
Temperature range +5°C to +45°C
Temperature deviation over time ± 0.5 K
Itjdpfx Acjvz U Ersrjh
Humidity range 40% to 95%
Dew point range +4°C to +35°C
Humidity deviation over time ± 3 to 5% RH
Fresh air up to 7.5 m³/h
Power consumption without fresh air operation at 25°C / 75% RH approx. 0.8 kW
Characteristics for climatic tests with irradiation
Temperature range +10°C to +45°C with light on +10°C to +45°C
Temperature deviation over time ± 0.5 K
Humidity range 40% to 95%
Dew point range +4°C to +35°C
Humidity deviation over time ± 3 to 5% RH
Humidification and dehumidification system, stainless steel test chamber
Internal dimensions: Height 1400 mm, Depth 750 mm, Width 1270 mm
External dimensions: Height 1985 mm, Depth 980 mm, Width 2320 mm
External dimensions with lighting module: Height 2450 mm
Single door with observation window
Interface for computer connection
Connection 3/N/PE 400V ±10% 50Hz
CE marking, mobile, very good condition
Pipe penetration ∅ 50 mm
Air cooling
Refrigerant R404A
Weight approx. 480 kg + 130 kg lighting module
Listing
Schweinfurt
6,771 km
Emissions test chamber
VötschVCE 200
Call
Condition: used, Description: Emission Test Chamber
Manufacturer: Vötsch
Model: VCE 200
Test chamber volume: 200 liters
Temperature range: +20°C to +130°C
Humidity range: 30 to 95% RH
Temperature deviation: temporal ± 0.3 K
Temperature deviation: spatial ± 0.5 K
Average temperature change rate: cooling approx. 0.3 K/min, heating approx. 0.4 K/min
Dew point range: +5°C to 60°C
Humidity deviation: temporal ± 1 to 3% RH
Voltage: 3/N/PE AC 400V±10% 50Hz
Rated power / rated current: 21 kW / 41 A
Itedjxg Hrqspfx Acrsh
Refrigerant: R404A
Internal test chamber dimensions: 610 x 610 x 560 mm (W/D/H)
Overall dimensions: 1250 x 1700 x 2350 mm (W/D/H)
Weight: approx. 750 kg
Item Condition:
Used item as shown in the pictures
Please contact us if you have any questions
Shipping:
The quoted shipping costs apply to deliveries within Germany
Worldwide shipping available (please inquire for shipping costs outside Germany)
The given shipping costs apply to shipping within Germany
Sale exclusively to business customers, without warranty or guarantee.
Deviations from technical data and errors in the item description may occur and are reserved.
Listing
Borken
7,009 km
Temperature shock test chamber
EspecTSD-100 -70 °C bis +200 °C
Call
Condition: excellent (used), Here, we offer a temperature shock test chamber with a 100-liter usable volume for larger test specimens up to 30 kg. Compliant with all common international standards.
Water-cooled
Temperature range, warm chamber: +60 °C to +200 °C
Temperature range, cold chamber: -70 °C to 0 °C
Test chamber dimensions: 710 x 345 x 410 (W x H x D) in mm
Itodpfxszfg Ups Acroh
External dimensions: 1100 x 1885 x 1965 (W x H x D) in mm
Water-cooled refrigeration unit
Program control via touch panel
Automatic defrost
Over-temperature protection
Operating hour counter
Mobile design
2 test specimen baskets made of stainless steel
Cable entry Ø 100 mm
Refrigerant: 3 kg R404A, 1 kg R23
Power supply: 400V 3-phase 50Hz
Max. power consumption: 32A
Type: TSD-100
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Temperature test chamber
VötschVTS³ 7018-5
Call
Condition: excellent (used), Vötsch
Type: VTS³ 7018-5
Water-cooled
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 900 mm x Depth 1550 mm x Height 1850 mm
Temperature testing:
Temperature range: -70°C to +180°C
Temperature change rate: Heating 7.5 K/min
Temperature change rate: Cooling 7.5 K/min
Test chamber volume: 190 liters
Rated voltage: 400 V
Rated current: 20 A
Rated power: 9 kW
Weight: approx. 540 kg
Itedpfxozfg Uce Acroh
Refrigerant: R404A and R23
For your safety as a buyer, please note the following information:
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerants
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications are reserved!)
We will be happy to answer any further questions you may have by phone.
Listing
Borken
7,009 km
Shock test chamber
VötschVT 7012 S3
Call
Condition: excellent (used), Vötsch Shock Test Chamber
Here we offer you a Vötsch shock test chamber.
Water-cooled
Temperature range: -80°C to +220°C
Warm chamber: +50 to +220
Intermediate chamber: -10 to +90
Cold chamber: -80 to +70
Supply voltage: 400V ±10% 3/N 50Hz
Rated current: 30.5 A
Rated power: 13.5 kW
Refrigerant VK: R 404A 3.00 kg p*: 25 bar
Refrigerant TK: R23 15 bar p*: 25 bar
Iodpfxozd Uzuj Acroth
Condition: used
Type: VT 7012 S3
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have by phone.
Listing
Borken
7,009 km
Stress test chamber
EspecEHS-221M
Call
Condition: excellent (used), Espec
We are offering an Espec (ThermoTec) stress test chamber.
Itjdpfx Acszd Uy Doroh
Overpressure and humidity tests at over 100 degrees Celsius in various modes.
Program capacity for 10 samples with 30 steps per sample.
A variety of safety mechanisms: overheating/overpressure protection, detection of water supply failure, complete door locking, and temperature sensor.
Saturated temperature range: 105 to 142.9°C.
Unsaturated temperature range: 105 to 132.9°C.
Humidity range: 50 to 100% RH.
Nominal pressure: 0.196 MPa at 132.9°C and 100% RH.
External dimensions: Width 740 x Height 1553 x Depth 1000 mm.
Test chamber dimensions: Width 355 x Height 355 x Depth 426 mm.
Other features:
With rails and grid.
Test item connections inside the chamber.
Type: EHS-221M
Scope of delivery: See images.
300 kg
Condition: Used
Scope of delivery: (See image)
(Changes and errors in the technical data and specifications are reserved!)
We would be happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Temperature test chamber -20°C...+140°C
TIRATTRE 2001 S
Call
Condition: excellent (used), Here we offer a TIRA temperature testing chamber.
TIRA temperature testing chamber, air-cooled.
The chamber has the option for an external test box, including an external sensor connection, and can therefore also be used as an external temperature control unit.
Temperature range: -20°C to +140°C
Temperature stability over time: ±0.1°C to ±0.3°C
External dimensions: Width 860 mm x Depth 1500 mm x Height 2100 mm
Test chamber dimensions: Width 601 mm x Depth 545 mm x Height 692 mm
Electrical connection: 400V +6% / -10% 50Hz 3P+N+PE
Rated current: 10.0 (max. 17) A
Rated power: 5.2 (max. 9.0) kW
Net weight: 735 kg
Refrigerant: R404A / R23
Itodpszd Umqsfx Acrjh
Type: TTRE 2001S
For your safety as a buyer, please note the following information:
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We would be happy to answer any further questions you may have by phone.
Listing
Borken
7,009 km
Climate test chamber with humidity
WeissSB2/500/80 -75°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss climate test chamber.
Designation: SB2/500/80, water-cooled
Cold-heat operation: -75°C ... +180°C
Climate operation: +10...+95°C
Humidity range: 10...98 % RH
Temperature stability, over time: ± 0.2K
Humidity stability: ±1 % RH
Itjdozd Ultspfx Acroh
Temperature change rate:
Cooling: approx. 1.4 K/min
Heating: approx. 2.5 K/min
External dimensions: Height 1980 mm, Width 1265 mm, Depth 1365 mm
Connections:
left side: ∅ 100 mm
right side: ∅ 50 mm
The connection voltage is:
400V/3Ph+N+PE/50 Hz
Power: 10.4 kVA
Weight: approx. 720 kg
Refrigerant: R404a / R23
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leakage test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: SB2/500/80
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data and information are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), Weiss Temperature Shock Test Chamber
Here we offer a temperature shock test chamber.
Weiss Temperature Shock Test Chamber, Water-Cooled
Specification:
Temperature range, hot chamber: +60°C … +220°C
Temperature range, cold chamber: -10°C … -80°C
Hot/cold chamber switching time: 10 sec.
Temperature stability: ±1 K
Dimensions and other data:
External dimensions: Height 1990 mm
Width (without and with door hinge): without… approx. 1820 mm, with… approx. 1850 mm
Depth (without and with test chamber door): without… approx. 900 mm, with… approx. 1155 mm
Dimensions of the lifting platform (test chamber): Height 450 mm, Width 500 mm, Depth 600 mm
Volume: 130 liters
Test chamber load: max. 20 kg
Load on the test chamber floor: max. 20 kg
Cooling water pressure: min. 2 ... max. 6 bar
Max. fuse rating: 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of the device: approx. 65 dB(A)
Refrigeration cascade, water-cooled
Connection values: 3/N/PE/AC 400V ±10% 50Hz / 14.0 kW
Rated current: 26.0 A
Refrigerant: R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Itjdpfxezd Ulgj Acreh
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Temperature test chamber
Heraeus VötschVTS 7033
Call
Condition: excellent (used), Heraeus Vötsch Temperature Test Chamber
Here we offer a Heraeus Vötsch temperature test chamber.
Itedpfxjzd Sf Do Acroh
Vötsch Temperature Test Chamber VTS 7033, Water-Cooled
Temperature range: -70°C to +180°C
Temporal temperature deviation: ± 0.5 K
Spatial temperature deviation: ± 1.5 K
Heating rate: 7.5 K/min
Cooling rate: 6.5 K/min
Test chamber dimensions: Width 825 mm x Depth 800 mm x Height 870 mm
Housing dimensions: 1080 mm x 1710 mm x 1950 mm
Side openings: 12 cm and 13 cm
Voltage: 400V +6/-10%, 3/N, 50Hz
Rated power: 9.5 kW, Rated current: 22 A
Refrigerant: R404A / R23
Approx. 570 liters, Weight: 580 kg
For your safety as a buyer, please note the following information:
The following steps are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Type: VTS 7033
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Temperature test chamber
RS-SimulatorenTS 150/75
Call
Condition: excellent (used), RS Simulators
Here we offer a temperature test chamber.
Temperature Test Chamber, Water-Cooled
Temperature range: -70°C to +180°C
Time deviation: ±1 K according to DIN 50011 in an empty test chamber
Average heating time: approx. 3 K/min (according to DIN 50011 Part 12)
Average cooling time: approx. 3 K/min (according to DIN 50011 Part 12)
Test chamber dimensions: Width 530 mm x Height 530 mm x Depth 530 mm
External dimensions: Width approx. 900 mm x Height approx. 1800 mm x Depth approx. 1400 mm
Total power: approx. 6 kVA
Itodozd Sfqjpfx Acrjh
Current consumption: 12 A
Main fuse: 3 x 16 A, slow-blow
Connection voltage: 3x400V/N/PE 50Hz
Weight: approx. 600 kg
Type: TS 150/75
Refrigerant: R404A / R23
Condition: used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data and specifications!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), Weiss Temperature Shock Test Chamber
Here we offer a temperature shock test chamber.
Weiss Temperature Shock Test Chamber, Water-Cooled
Specifications:
Temperature range, hot chamber: +60°C … +220°C
Temperature range, cold chamber: -10°C … -80°C
Switching time, hot/cold chamber: 10 s
Temperature stability: ±1 K
Dimensions and other data:
External dimensions: Height 1990 mm
Width (without and with door hinge): without... approx. 1820 mm, with... approx. 1850 mm
Depth (without and with test chamber door): without... approx. 900 mm, with... approx. 1155 mm
Dimensions of the lifting platform (test chamber): Height 450 mm, Width 500 mm, Depth 600 mm
Volume: 130 liters
Test chamber load: max. 20 kg
Load on the test chamber floor: max. 20 kg
Cooling water pressure: min. 2 ... max. 6 bar
Max. fuse rating: 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of the device: approx. 65 dB(A)
Refrigeration cascade, water-cooled
Connection values: 3/N/PE/AC 400V ±10% 50Hz /18.7 kW
Rated current: 26.0 A
Refrigerant: R 404A / R23
Weight: approx. 950 kg
Isdpfxozd Sfde Acreth
Type: TS 130
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Temperature shock test chamber
Weiss130 Liter TS 130 *
Call
Condition: excellent (used), Here we offer you a temperature shock testing chamber.
Weiss temperature shock testing chamber, air-cooled
Specification:
Temperature range, warm chamber: +60°C … +220°C
Temperature range, cold chamber: -10°C … -80°C
Changeover time, warm/cold chamber: 10 s
Temperature stability: ±1 K
Dimensions and other data:
External dimensions: height 1990 mm
Width (without and with door hinge): without… approx. 1820 mm, with… approx. 1850 mm
Depth (without and with test chamber door): without… approx. 900 mm, with… approx. 1155 mm
Dimensions of the lifting platform (test chamber): height 450 mm, width 500 mm, depth 600 mm
Volume: 130 liters
Test chamber load: max. 20 kg
Load on the test chamber floor: max. 20 kg
Cooling water pressure: min. 2 ... max. 6 bar
Max. fuse rating: 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of the device: approx. 65 dB(A)
Refrigeration cascade, water-cooled
Connection values: 3/N/PE/AC 400V ±10% 50Hz /14.0 kW
Rated current: 26.0 A
Refrigerant: R 404A / R23
Weight: approx. 950 kg
Isdpfxjzd Sd Ho Acrjth
Type: TS 130
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), Weiss Temperature Shock Test Chamber
Here we offer you a temperature shock test chamber.
Itodszd Sdyopfx Acroh
Weiss Temperature Shock Test Chamber, Air-Cooled
(Compressor has been replaced!)
Specifications:
Temperature range, hot chamber: +60°C … +220°C
Temperature range, cold chamber: -10°C … -80°C
Hot/cold chamber switching time: 10 s
Temperature stability: ±1 K
Dimensions and other data:
External dimensions: Height 1990 mm
Width (without and with swivel arm): without... approx. 1820 mm, with... approx. 1915 mm
Depth (without and with test chamber door): without... approx. 900 mm, with... approx. 1155 mm
Dimensions of the lifting platform (test chamber): Height 450 mm, Width 500 mm, Depth 600 mm
Volume: 130 liters
Test chamber load: max. 20 kg
Load on the test chamber floor: max. 20 kg
Cooling water pressure: min. 2 ... max. 6 bar
Max. fuse rating: 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of the device: approx. 65 dB(A)
Connection values: 3/N/PE/AC 400V ±10% 50Hz / 14.0 kW
Rated current: 26.0 A
Refrigerant: R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by phone.
Listing
Borken
7,009 km
Climatic test chamber
Feutron3702/06
Call
Condition: excellent (used), Feutron
Type: 3702/06
Water-cooled climate test chamber
Technical data:
Nominal volume of test chamber: 2.0 m³
Dimensions: Test chamber exterior, with humidifier console
Itodpfx Ajzd Sdmocrsh
Width: 2970 mm, Height: 2370 mm, Depth: 1530 mm
Rear wall
Minimum insertion dimensions: Width: 2970 mm, Height: 2390 mm, Depth: 1550 mm
Test chamber: Width: 2000 mm, Height: 1000 mm, Depth: 1000 mm
Door: double-leaf, clear opening width 2000 mm, height 1000 mm
Viewing window, heated, 2 pieces, width 500 mm, height 600 mm
Feed-through opening, 1 piece, left side wall, diameter 75 mm
Temperature range: -40...100°C
Climate range: 10...95°C
Temperature difference, time-dependent ≤ ± 0.5...± 1.0 ΔN/K
Rate of change measured in the supply air, without load
Cooling up to 2.0 on average K/min
Heating up to 2.0 on average K/min
Humidity range: 10...95 % RH
Humidity difference, time-dependent ≤ ± 3.0 % RH
Dew point range, intermittently up to -5...95°C
Refrigeration system: water-cooled, semi-hermetic Bitzer system
Refrigerant: R507 (Μ-Κ1)
Climate and dryer refrigeration system: air-cooled / hermetic system
Refrigerant: R134a (Μ.ΚΚ)
Power supply:
Electrical connection: 400V 3/N/PE.AC, 50Hz
Power plug: CEE 5-pin, 32 A, with 5.0 m cable
Max. simultaneous power requirement: 10.0 kW
Supply line fuse: 3x 25, Char, C A
Protection class: IP20
Weight: 1300 kg
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Climate test chamber with humidity control
Feutron3707/06 Temp. -40°C bis 150°C
Call
Condition: excellent (used), Here we offer a Feutron climate test chamber.
Feutron Climate Test Chamber
Temperature
Temperature range: -40...90°C
Climatic range (without heat load): 10...85°C
Temporal temperature deviation during temperature operation: ≤ ± 0.5 K/min
Temporal temperature deviation during climatic operation: ± 1.0... ± 1.5 K/min
Change rates
Heating: avg. 2.0 K/min
Cooling: avg. 2.0 K/min
Standard IEC 1646 is achievable with testing, solar modules up to max. 160kg weight and nonlinear ramps (setpoint jump)
Drying
Air drying: condensation drying
Humidity
Air humidification: steam humidification
Humidity range: 10...95 % r.h.
Temporal humidity deviation: ≤ ± 3.0... ±5.0 % r.h.
Dew point range: 8...80.9°C
Test Chamber
Test chamber volume: 7.0 m³
Dimensions
Internal dimensions: Width 1500 mm x Height 2250 mm x Depth 2000 mm
Swing door DIN right, heated, Width 900 mm x Height 2100 mm
Observation window, heated, with blackout shutter and lockable: Width 500 mm x Height 600 mm
Feedthrough: 2x, right front side, Ø 75 mm
Irradiation unit, test chamber
Opening: 4x in left side wall for SC 2500, each 850 x 700 mm
Irradiated area when using SC 2500: 1200 x 1200 mm
Radiation intensity at 1.0 m wall distance: 1000 ± 10% W/m²
Lighting: 1x halogen lamp, 200W
Ijdozd Sdgepfx Acreth
Refrigeration system: Bitzer compressor, semi-hermetic, 2-stage, air cooled
Condenser: split condenser (outdoor installation, winter control)
Refrigerant: R507 / R23
Temperature control system
Coolant medium Tyfocor / water
Mixing ratio 50/50%
Coolant density: 1.072 kg/dm³
Filling quantity: approx. 80 dm³
Pyranometer
Temperature range: -40...150°C
Max. radiation absorption: 4000 W/m²
Spectral range (50% points): 305...2800 nm
Sensitivity (nominal): 7 µV/W/m²
Power supply, test chamber
Mains connection: 400V, 3/N/PE, AC, 50Hz
Connection type: hardwired
Max. simultaneous power demand: approx. 32.0 kW
Supply fuse: 3 x 63, Char C (A)
Power supply, SolarConstant
Mains connection: 400V, 3/N/PE, AC, 50Hz
Connection type:
Max. simultaneous power demand: approx. 30.0 kW
Supply fuse: 3 x 63, Char C (A)
Overall external dimensions of the test cell including: equipment room/control cabinet and control cabinet for SolarConstant 2500
External dimensions equipment room: Width 3440 mm x Height 2580 mm x Depth 2950 mm
/control cabinet: Width 2200 mm x Height 1830 mm x Depth 1100 mm
External dimensions condenser, split: Width 900 mm x Height 950 mm x Depth 2000 mm
Weight test chamber (total): approx. 2700 kg
Condenser empty weight: 153 kg
Weight: 2700 kg
Type: 3707/06
Condition: used
Scope of delivery: (see picture)
(Technical data and information are subject to change and errors!)
For further questions, we are happy to assist you by phone.
Listing
Borken
7,009 km
Shock test chamber
HeraeusHT 7012 S2
Call
Condition: excellent (used), Here, we offer a shock test chamber.
Water-cooled temperature shock test chamber
Two-chamber design
Warm chamber:
Temperature control in the warm chamber ranges from +50°C to +220°C
Temporal temperature deviation in the center of the usable space: ± 1 K
Itjdezd R Uwjpfx Acrjh
Spatial temperature deviation: ± 2 K
Temperature change rate:
Heating: 11 K/min
Cold chamber:
Temperature control in the cold chamber ranges from -65°C to +70°C
Temporal temperature deviation in the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate:
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Temperature range, warm chamber: +50°C to +220°C
Temperature range, cold chamber: -65°C to +70°C
Test chamber dimensions: Width 470mm, Depth 650mm, Height 410mm
External dimensions: Width 930mm, Depth 2115mm, Height 1970+mm
Rated power: 10 kW
Rated current: 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant: R404A / R23
Operating hours: 27,903 hours
Weight: 1000 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated instruments.
Type: HT 7012 S2
Condition: used
Scope of supply: (See image)
(Changes and errors in the technical data are subject to change!)
We are happy to answer any further questions you may have by phone.
Listing
Borken
7,009 km
Climate test chamber 280 liters
FeutronKPK 200 Typ: 3416/16 +5 °C bis +100 °C
Call
Condition: excellent (used), We offer a climate test chamber for sale.
Air-cooled
Test chamber nominal volume: 280 liters
Dimensions:
Iodpjzd R T Tjfx Acroth
External dimensions of the test chamber: 1500 x 2040 x 1075 mm
With fan motor and door removed: 1500 x 1940 x 925 mm
Test chamber: 720 x 690 x 560 mm
Door, clear opening: 720 x 690 mm
Viewing window, heated: 500 x 600 mm
Temperature range:
+5 to +100 °C
Heating rate: 4.0 K/min
Cooling rate: 0.6 K/min
Climate range: +10 to +95 °C
Humidity range: 10 to 95 % RH
Humidity change rate: ≤ ± 3.0
Water connection for humidifier: Tap water or distilled water, 20-liter reservoir
Power connection: 400 V 3/N/PE, AC, 50 Hz
Maximum power consumption: 6.3 kW
Weight: 500 kg
Type: 3416/16
Refrigerant: R134a
For your peace of mind as a buyer, please note the following:
The following steps are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated instruments.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
Listing
Borken
7,009 km
Temperature test chamber 335 liters
VötschVTS 7034-5 -70°C bis +180°C
Call
Condition: excellent (used), Heraeus Vötsch Temperature Test Chamber
Here we offer you a Heraeus Vötsch temperature test chamber.
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
Temperature range: -70°C to +180°C
Temperature deviation (temporal): ±0.1 to ±0.5 K
Temperature deviation (spatial): ±0.5 to ±2.0 K
Temperature change rate (cooling): 5.0 K/min
Temperature change rate (heating): 6.5 K/min
Heat compensation at +20°C: 3000 W
Heat compensation at -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Test chamber volume: 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW, Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Side feedthrough: 5.5 cm / 12.5 cm
Chamber is water-cooled
Refrigerant: R 452A and R 23
Weight: approx. 570 kg
Type: VTS 7034-5
For your security as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of supply: (See picture)
Itedpfozd R Tgex Acroh
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Temperature test chamber
WEISSWT1-600/70
Call
Condition: excellent (used), Weiss Temperature Test Chamber
Here we offer you a Weiss temperature test chamber.
Weiss Temperature Test Chamber, Water-Cooled
Technical Data:
Test chamber designation: WT1-600/70
External dimensions without hinges and door closure
Ijdpezd R Svofx Acrsth
Height 1980 mm, Width 1085 mm, Depth 1655 mm
Internal dimensions
Height 950mm, Width 800mm, Depth 800mm
Test chamber volume: approx. 600 liters
Cold/heat operation: -70 to 180°C
Temperature change per unit of time
Cooling: approx. 2.5 K/min
Heating: approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 9.1 kW
Rated current: 19 A
Permissible weight of test specimens
Total load of the shelf supports: 80 kg
Refrigerant: R 404A + R23
Weight: 600 kg
Type: WT1-600/70
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have on the phone.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
7,009 km
Temperature test chamber
WEISSWT-600/70
Call
Condition: excellent (used), Weiss Temperature Test Chamber
Here we offer a temperature test chamber.
Weiss Temperature Test Chamber, Water-Cooled
Technical Data:
Test chamber designation: WT-600/70
External dimensions with hinges and door lock:
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock:
Height 1995 mm, Width 1000 mm, Depth 1660 mm
Internal dimensions:
Height 950 mm, Width 800 mm, Depth 800 mm
Test chamber volume: approx. 600 liters
Cold / heat operation: -70°C to 180°C
Temperature change per unit of time:
Itedpfx Ajzd R Drecroh
Cooling down: approx. 2.5 K/min
Heating up: approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 9.1 kW
Rated current: 19 A
Fuse (customer-supplied): 32 A slow-blow
Permissible weight of test specimen:
Total load of the shelf supports: 80 kg
Test chamber floor: 80 kg, insert shelf: 40 kg
Refrigerant: R 404A/R23
Weight: 675 kg
Type: WT-600/70
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and information are subject to change!)
We are happy to answer any further questions you may have by phone.
Listing
Borken
7,009 km
Shock test chamber
HeraeusHT 7012 S2
Call
Condition: excellent (used), Heraeus Shock Test Chamber
We offer a shock test chamber here.
Temperature shock test cabinet, water-cooled
Two-chamber design
Warm chamber:
Iedpfxozd R Azs Acroth
The temperature control of the warm chamber ranges from +50°C to +220°C
Temporal temperature deviation in the center of the usable space ± 1 K
Spatial temperature deviation ± 2 K
Temperature change rate
Heating 11 K/min
Cold chamber:
The temperature control of the cold chamber ranges from -65°C to +70°C
Temporal temperature deviation in the center of the usable space ± 1 K
Spatial temperature deviation ± 2 K
Temperature change rate
Heating 2 K/min
Cooling 3 K/min
Test chamber volume 125 liters
Temperature range, warm chamber +50°C to +220°C
Temperature range, cold chamber -80°C to +70°C
Test chamber dimensions: width 470mm, depth 650mm, height 410mm
External dimensions: width 930mm, depth 2115mm, height 1970+mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant R404A / R23
Weight: 1000 kg
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Type: HT 7012 S2
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications are reserved!)
We will be happy to answer any further questions you may have by phone.
Listing
Borken
7,009 km
Temperature test chamber, explosion-proof
CTST-30/950 Ex/I
Call
Year of construction: 2011, condition: excellent (used), CTS
Type: T-30/950 Ex/I
CTS Temperature Test Chamber, Explosion-Proof
Control – 32-bit controller
LCD control panel
Digital display for set and actual values
Numerical input of set values
Error messages in plain text
RS 232 interface
Free switching channels for product-side test specimen activation
Temperature Testing:
Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
Heating: 2 K/min
Cooling: 1.5 K/min down to -10°C
Thermal radiation: approx. 1000 W at +20°C
approx. 200 W at -25°C
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with a large flow rate of N2 until the
o2 content drops below 3%. Then, it switches to a base flow amount (approx. 10% of the large flow rate).
The nitrogen flow for the base amount is measured and displayed using a flowmeter and monitored via a limit switch.
O2 monitoring continuously extracts gas from the test chamber via a flame arrestor and passes it over an O2 sensor which checks the residual oxygen content of the extracted air.
Afterwards, the gas is returned to the test chamber via a second flame arrestor.
The extraction pump is monitored by a volumetric flow meter. Additional details can be found in the Dräger user manual in the appendix.
The gas system is currently deactivated!
All technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without irradiation, and without additional equipment.
Dimensions:
Test chamber volume: 950 liters
Test chamber dimensions: Height approx. 700 mm / Width approx. 900 mm / Depth approx. 1500 mm
Itedpfx Acszd Rzweroh
External dimensions: Height approx. 2400 mm / Width approx. 1270 mm / Depth approx. 3125 mm
Operating data:
Electrical connection: 400V +6/-10 %, 3/N, 50 Hz
Nominal power: 21.6 kW
Rated current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, R 1/2" inner thread
Sound pressure level:
Listing
Borken
7,009 km
Shock test chamber -80°C to +220°C
VötschVT 7012 S2
Call
Condition: excellent (used), Here, we offer a Vötsch shock test chamber.
Temperature shock test cabinet, water-cooled
Two-chamber design
Warm chamber:
The temperature control of the warm chamber ranges from +50°C to +220°C
Temporal temperature deviation in the center of the usable space ± 1 K
Spatial temperature deviation ± 2 K
Temperature change rate
Heating 11 K/min
Cold chamber:
The temperature range of the cold chamber is from -80°C to +70°C
Temporal temperature deviation in the center of the usable space ± 1 K
Spatial temperature deviation ± 2 K
Temperature change rate
Heating 2 K/min
Cooling 3 K/min
Test chamber volume 125 liters
Temperature range, warm chamber +50°C to +220°C
Temperature range, cold chamber -80°C to +70°C
Test chamber dimensions: width 470mm, depth 650mm, height 410mm
External dimensions: width 930mm, depth 2115mm, height 1970+mm
Feedthrough ∅ 67mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant R404A / R23
Weight: 1000 kg
For your safety as a buyer, please note the following information:
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
Iodpfxszd Rzkj Acrjth
2. New filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a test run, which will be monitored with calibrated devices.
Type: VT 7012 S2
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We will gladly answer any further questions you may have by phone.
We make it easier for you to find: "vötsch emissions test chamber"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you
































































































































































































































