Used Weiss Climate Test Chamber With Humidity for sale (17,024)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
7,009 km
Climate test chamber 350 liters with humidity control
CTSC -40/350 -40°C /+180°C
Call
Condition: excellent (used), CTS
Type: C-40/350
Air-cooled Climate Test Chamber
For sale is a professional CTS climate test chamber, model C-40/350. This device is designed for demanding environmental simulations in industrial applications and is ideal for material testing, electronics, automotive, aerospace, and research.
Temperature Testing:
- Temperature range: -40°C to +180°C
- Temperature deviation: ≤ ±0.3 K over time
- Temperature change rate according to IEC 60068-3-5:
- Heating: 3.5 K/min
- Cooling: 4 K/min
- Heat compensation:
- Approx. 3500 W at +20°C
- Approx. 2000 W at -20°C
Climatic Testing:
- Temperature range: +10°C to +90°C
- Humidity range: 10% to 95% relative humidity
- Dew point range: +5°C to +78°C
- Temperature deviation: ≤ 1.0 K over time
- Humidity deviation: ≤ ±3.0% r.h. over time
Technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without heat compensation, and without additional accessories. Options may influence performance data.
Technical Specification:
- Refrigeration unit: Air-cooled, low-noise, fully hermetic, infinitely variable performance adjustment via electronic monitoring and control system, environmentally friendly refrigerant R404A
- Test chamber floor load: 150 kg/m²
- Shelf: Stainless steel, support surface 620 x 600 mm
- Maximum load per shelf: 35 kg
- Total load with maximum number of shelves: 100 kg
Control:
- 32-bit controller
- LCD control panel
- Digital display of setpoint and actual values
- Numeric entry of setpoints
- Plain-text error messages
- RS 232 interface
- Ethernet interface
- Free switching channels for external test sample control
Dimensions:
- Test volume: 350 liters
- Internal dimensions: Height 750 mm × Width 650 mm × Depth 720 mm
- External dimensions: Height 1800 mm × Width 920 mm × Depth 1670 mm
Operating Data:
Ijdpfjzizmzex Af Eoid
- Electrical connection: 400V 3/N, 50 Hz
- Rated power: 7.1 kW
- Rated current: 11.5 A
- Protection class: IP 54
- Sound pressure level:
Listing
Borken
7,009 km
Climate test chamber with humidity, 335 liters
WeissWK3-340/40 -42°C bis +180°C
Call
Condition: excellent (used), Weiss
Model: WK3-340/40
Weiss Climate Test Chamber, Air-Cooled
Temperature Testing
Volume: 335 liters
Test Chamber Dimensions:
Internal Dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External Dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Minimum Temperature: –42°C
Maximum Temperature: +180°C
Temperature Change Rate, Cooling: 4 K/min
Temperature Change Rate, Heating: 3.2 K/min
Temperature Deviation Over Time: ± 0.1 to ± 0.5 K
Temperature Uniformity Spatially: ± 0.5 to ±1.5 K
Iedpjziyygofx Af Ejid
Climate Testing:
Temperature Range: +10°C to +95°C
Dew Point Range: -3°C to +94°C
Humidity Range: 10 to 98% RH
Temperature Deviation Over Time: ± 0.1 to ± 0.3 K
Temperature Uniformity Spatially: ± 0.5 to ± 1 K
Humidity Deviation Over Time: ± 1 to ± 3 % RH
Halogen Lamp: 2 x 24V, 50W
Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated Power: 4.1 kW, Rated Current: 14 A
Refrigerant: R-404A
Weight: approx. 515 kg
For your security as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications reserved!)
Further questions can be answered by phone.
Listing
Borken
7,009 km
Climate test chamber 335 liters with humidity
VötschVCS³ 7034-5 -70°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VCS³ 7034-5
Vötsch Climate Test Chamber, Water-Cooled
With temperature change rate of 5 K/min
Specifications for temperature testing:
Temperature range: -70°C to +180°C
Temporal temperature deviation in the center of the usable space: ±0.1 K to ±0.5 K
Iijdpfeziyx Nsx Af Esd
Spatial temperature deviation: ±0.5 K to ±2.0 K
Temperature change rate:
Heating: 6.8 K/min
Cooling: 6.7 K/min
Specifications for climate testing:
Temperature range: +10°C to +95°C
Temporal temperature deviation in the center of the usable space: ±0.1 K to ±0.3 K
Spatial temperature deviation: ±0.5 K to ±1.0 K
Temporal humidity deviation in the center of the usable space: ±1% to ±3% RH
Humidity range: 10% to 98% RH
(Extended climate range: 2°C/95% RH regulated for a maximum of 2 hours)
Exterior dimensions (W x D x H): 870 x 1700 x 1775 mm
Test chamber dimensions (W x D x H): 580 x 765 x 750 mm
Test chamber volume: approx. 335 liters
Side ports: 50 mm and 125 mm
Operating data:
LED strip 24 V, 6.8 W / 2 x halogen bulbs 24 V, 50 W
Rated voltage: 3/N/PE AC 400 V ±10%, 50 Hz
Rated power: 9 kW Rated current: 20 A
Customer-side fuse: 63 A slow-blow
Refrigerant: R404A / R-23
Weight approx. 570 kg
For your security as a buyer, please note the following:
The following procedures are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant, if needed
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see image)
(Technical data and information subject to change and errors!)
Further questions can be answered by phone.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Borken
7,009 km
Climate test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Type: VCS 7034-5
Climatic Test Chamber, Water-cooled
Iisdpfxoziyxie Af Eed
Vötsch VCS 7034-5
Test Volume: 335 liters
Specifications for Temperature Testing:
Temperature range: -70 to +180°C
Time-based temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration points: +23°C and +80°C
Specifications for Climate Testing:
Temperature range: +10 to +95°C
Time-based temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Time-based humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration points: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerants: R452A / R-23
Important safety information for buyers:
The following procedures are carried out on our offered chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. Recharging with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful testing, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Subject to technical modifications and errors. All information is non-binding!)
For further questions, please do not hesitate to contact us by phone.
Listing
Borken
7,009 km
Climate test chamber with humidity
CTSCS-70/350 350 Liter -70°C /+180°C
Call
Condition: excellent (used), Here we offer you a climate chamber.
Water-cooled
Test chamber volume: 350 liters
Internal chamber dimensions: Height 750 mm, Width 650 mm, Depth 720 mm
External dimensions: Height 1800 mm, Width 850 mm, Depth 1640 mm
Temperature working range:
Temperature range: -70°C to +180°C
Cooling rate: 3.0 K/min
Heating rate: 5.0 K/min
Climate working range:
Temperature range: +10°C to +90°C
Humidity range: +10% to 98% RH
Dew point range: +5°C to 89.5°C
Temperature deviation: ±0.1 - ±0.3 K over time
Humidity deviation: ±1 - ±2% RH over time up to 90% RH
max. ±1 - 3% RH over time above 90% RH
Electrical connection: 400V +6-10%, 3/N, 50Hz
Connected load: 13 kW
Rated current: 25.5 A
Refrigerant: R404A / R23
Weight: 650 kg
Type: CS-70/350
For your safety as a buyer, please note the following information:
The following steps are performed in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a trial run which is monitored with calibrated equipment.
Isdpfoziyw Eex Af Eeid
Condition: used
Scope of delivery: (see photo)
(Specifications, technical data and details may be subject to change. Errors excepted.)
For any further questions, we are happy to assist you by phone.
Listing
Borken
7,009 km
Climate test chamber 600 liters with humidity
WeissWK3-600/0-M -5°C bis +90°C
Call
Condition: excellent (used), Weiss
Model: WK3 600/0-M
Weiss Climate Test Chamber, Water-Cooled
Series: WK3-../0
with SIMPAC* Controller
Iisdpeziywrefx Af Esd
Test chamber volume: approx. 600 liters
Test chamber dimensions: Height 950 mm, Width 800 mm, Depth 800 mm
External dimensions: Height 1995 mm, Width 1090 mm, Depth 1660 mm
Operating data:
Test chamber lighting: LED 24 V, 6.8 W / Halogen bulb 2 x 24V, 50W
Rated voltage: 1/N / PE AC 230 V ±10% 50 Hz
Rated power: 2.3 kW
Rated current: 10 A
Site-provided fuse: 16 A slow-blow
Control cabinet and operator panel protection class: IP 54
Maximum heat emission to environment: 1200 W
Sound pressure level:
Measured at a distance of 1m from the front, at a height of 1.6m: 46 dB(A)
Data for temperature tests:
Temperature range: -5°C to +90°C
Temporal temperature deviation at center of usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Temperature gradient (according to IEC 60068-3-5)
Temperature change rate:
Heating 0.6 K/min
Cooling 0.3 K/min
Heat compensation at +20°C to +50°C: 200 W
Data for climatic tests:
Temperature range: +10°C to +90°C
Dew point range: 4 to +89.5°C
Humidity range: 10 to 98 % r.h.
Temporal temperature deviation at center of usable space: ± 0.1 to ± 0.3 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Temporal humidity deviation: +1 to +3 % r.h.
Refrigerant: R-404A
Weight: 610 kg
For your safety as a buyer, please note the following information!
The following points are carried out in advance on our offered chambers:
1. Functionality check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of delivery: (See image)
(Technical data and information subject to change and errors!)
We are happy to answer any further questions you may have by phone.
Listing
Borken
7,009 km
Climate test chamber with humidity
VötschVC³ 0100 0°C bis + 90°C
Call
Condition: excellent (used), Vötsch
Type: VC³ 0100
Vötsch Climate Test Chamber, Air-Cooled
Internal Test Chamber Dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
Overall Device Dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Test Chamber Volume: 990 litres
Temperature Testing:
Minimum Temperature: -0°C
Maximum Temperature: +90°C
Temperature Change Rate, Cooling: 0.2 K/min
Temperature Change Rate, Heating: 0.5 K/min
Temporal Temperature Deviation: ±0.1 to ±0.5 K
Spatial Temperature Uniformity: ±0.5 to ±1.0 K
Heat Compensation at +20 °C: 350 W
Climatic Testing:
Minimum Temperature: +10°C
Maximum Temperature: +90°C
Dew Point Temperature Range: +4°C to +89.5°C
Humidity Range: 10 to 98% r.h.
Temporal Humidity Deviation: ±1 to ±3% r.h.
Temporal Temperature Deviation: ±0.1 to ±0.3 K
Spatial Temperature Uniformity: ±0.5 to ±1.0 K
Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated Power: 2.3 kW
Rated Current: 10 A
Refrigerant: R-404A
Weight: approx. 1400 kg
Important information for you as a buyer:
The following measures are carried out on our offered chambers prior to delivery:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certification
4. After successful inspection, the chambers undergo a documented test run.
Iodpfx Afeziypue Esid
Condition: used
Scope of delivery: (see image)
(Specifications and technical details are subject to change and error!)
For further questions, we are happy to assist you by phone.
Listing
Borken
7,009 km
Climate test chamber with humidity
VötschVC³ 4100 990 Liter -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Vötsch climatic test chamber.
Model: VC³ 4100, air-cooled
With a temperature change rate of 3 K/min
Test chamber internal dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
Overall unit dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Chamber volume: 990 liters
Port openings: Ø 125 mm, Ø 50 mm
Temperature test specifications:
Temperature range: -42°C to +180°C
Temporal temperature deviation: ± 0.1 to ± 0.5 K
Spatial temperature uniformity: ± 0.5 to ± 1.5 K
Temperature change rate:
Heating: 4.0 K/min
Cooling: 3.0 K/min
Max. heat compensation at +20°C: 4500 watts
Climatic test specifications:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Humidity range: 10 to 98% r.h.
Temporal temperature deviation: ± 0.1 to ± 0.3 K
Spatial temperature uniformity: ± 0.5 to ± 1.0 K
Temporal humidity deviation: ± 1% to ± 3% r.h.
Max. heat compensation: 500 W
Iiodpeziypnsfx Af Eed
Power supply: 3/N/PE AC 400V ±10% 50Hz
Rated power: 11.5 kW
Rated current: 22.0 A
Refrigerant: R-404A
Weight: approx. 840 kg
Type: VC³ 4100
For your security as a buyer, please note the following information!
The following points are checked and carried out on all our chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. If needed, fresh filling with legally compliant refrigerant
3. Leak check with certificate
4. After a successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See photo)
(Subject to prior sale, changes and errors in technical data and specifications reserved!)
We are happy to answer any further questions by phone.
Listing
Borken
7,009 km
Climatic test chamber with humidity, 600 liters
CTSC-40/600 -40 bis +180°C
Call
Condition: excellent (used), CTS Climate Test Chamber Type: C -40/600, Air-Cooled
(converted to R-452a refrigerant)
Test chamber volume: 600 liters
Temperature tests:
- Temperature range: -40°C to +180°C
- Temperature deviation: ±0.1 K / ±0.3 K over time (at stabilized condition)
- Average temperature rate of change (without test load and radiant heat):
- Heating: 2.5 K/min
- Cooling: 3.0 K/min
- Maximum radiant heat input: 2500 W at +20°C
Climatic tests:
- Climate range / Technical data:
- Temperature range: +10°C to +95°C
- Humidity range: 10% r.h. to 98% r.h.
Isdpfxjziizgo Af Eoid
- Dew point range I: +7°C to +94°C
- Dew point range II: –10°C to +7°C
- Consistency values (over time):
- Humidity consistency I: ±0.5% r.h. to ±1.5% r.h.
- Humidity consistency II: ±1% r.h. to ±3% r.h.
- Temperature consistency: ±0.1 K to ±0.3 K
Chamber internal dimensions (approx.): Height: 850 mm, Width: 850 mm, Depth: 830 mm
External dimensions (approx.): Height: 1900 mm, Width: 1115 mm, Depth: 1850 mm
Refrigerant: R-452A
Power connection: 400V 3/N 50Hz
Connected load: 8.2 kW, Rated current: 11.9 A
Weight: 550 kg
Important information for your purchase!
The following checks and procedures are performed on all our offered chambers prior to delivery:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see image)
(Subject to changes and errors in the technical data and specifications!)
If you have further questions, we will be happy to answer them by phone.
Listing
Borken
7,009 km
Climate test chamber with humidity
Weiss -72°C bis +180°CWK3-340/70
Call
Condition: excellent (used), Weiss
Type: WK3-340/70
Weiss Climate Test Chamber, Air-Cooled
Control Panel: "Touch Panel"
All control and operating commands can be initiated on the "Touch Panel" control panel by simply touching the function symbols.
Adjustable Feet
To compensate for uneven floors and to ensure adequate ventilation of the machine, the test chamber is equipped with adjustable feet.
Feedthroughs
The test chamber is equipped with feedthroughs on the right and left sides.
These allow measuring cables and testing equipment to be routed into the test chamber.
Feedthroughs installed as standard:
R1: 125 mm diameter
L1: 85 mm diameter
Volume: 335 liters
Test chamber dimensions:
Height: 750 mm, Width: 580 mm, Depth: 765 mm
External dimensions: Height: 1775 mm, Width: 870 mm, Depth: 1600 mm
Data for temperature tests:
Minimum temperature: -72°C
Maximum temperature: +180°C
Temperature deviation, over time: ± 0.1 to ± 0.5 K
Temperature homogeneity, spatially: ± 0.5 to ± 1.5 K
Temperature change rate, cooling: 3 K/min
Temperature change rate, heating: 3 K/min
Iijdpfxjziiwuo Af Esd
Data for climate tests:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Humidity range: 10 to 98% RH
Temperature deviation, over time: ± 0.1 to ± 0.3 K
Temperature homogeneity, spatially: ± 0.5 to ± 1 K
Humidity deviation, over time: ± 1 to ± 3% RH
Data for operation:
Test chamber lighting: Halogen bulb 2 x 24V, 50W
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 16 A, Rated power: 4.9 kW
Fuse: 16 A slow-blow (to be provided by the customer)
Refrigerant: R-452A/R23
Weight: Approx. 585 kg
For your security as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have by telephone.
Listing
Borken
7,009 km
Climate test chamber with humidity, 190 liters
VötschVC 7018 -70 bis 180°C
Call
Condition: excellent (used), Vötsch
Type: VC 7018
Vötsch Climatic Test Chamber VC 7018 Water-Cooled
Touch Panel Control Unit
On the touch panel control unit, all control and operating commands can be triggered by simply touching the function symbols.
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Ports
The test chamber is equipped with port holes on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Feedthrough included in standard equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Characteristics for temperature tests:
Temperature range: -70°C to +180°C
Temperature ±0.1 to ±0.5 K
Spatial ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min
Cooling: 2.3 K/min
Characteristics for climatic tests:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% r.h. F.
Temperature deviation over time in the center of the usable space ± 0.1 to ± 0.3 K
Temperature deviation over space ± 0.5 to ± 1.0 K
Temperature gradient 1 to 2 K
Humidity deviation over time in the center of the usable space ± 1 to ± 3 %RH
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10 50Hz
Nominal power: 5.9 kW
Nominal current: 12.0 A
Connection cable: 3.5 m
Fuse protection: 16 A slow-blow, provided by the customer
Refrigerants: R-404A and R-23
Test chamber capacity: approx. 190 liters
Weight: approx. 460 kg net
For your safety, the following information is provided as a buyer!
The following steps are performed on our offered chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
Isdozh Huhspfx Af Ejid
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Climate test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Type: VCS 7034-5
Water-cooled climatic test chamber
Iodpfx Afszg Twge Esid
Vötsch VCS 7034-5
Test chamber capacity 335 liters
Performance for temperature tests
Temperature range -70 to +180°C
Temperature deviation temporal K ±0.1 to ±0.5
Spatial temperature deviation K ±0.5 to ±2.0
Temperature gradient 1 to 4
Rate of change :
Cooling 6.7 K/min
Heating 6.8 K/min
Heat compensation at +20 °C 3000 W / at -20°C 3000 W
Temperature calibration values +23 °C and +80 °C
Performance for climate tests
Temperature range +10 to +95°C
Temperature deviation in time ±0.1 to ±0.3 K
Spatial temperature deviation ±0.5 to ±1.0 K
Temperature gradient 1 to 2 K
Humidity range 10 to 98%
Humidity deviation in time ±1 to ±3%
Dew point range -3 to +94°C
Heat compensation 400W
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 580mm Depth 765mm Height 750mm
External dimensions: Width 870mm Depth 1595mm Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64dB(A)
Cooling water consumption: 1.4m³/h
Refrigerant: R-404A / R-23
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Climate test chamber 335 liters 10-98% relative humidity.
VötschVC³ 0034 -10 °C bis +90 °C
Call
Condition: excellent (used), Vötsch VC³ 0034 Climate Test Chamber
Manufacturer: Vötsch Industrietechnik GmbH
Type: VC³ 0034
Machine Type: Climate Test Chamber / Climate Chamber
Test Chamber Volume: approx. 335 liters
For sale is a used climate test chamber from Vötsch for temperature and climate testing in laboratories, research, development, and quality assurance.
Technical Data
Test Chamber Dimensions: approx. 580 x 765 x 750 mm (W x D x H)
Housing Dimensions: approx. 875 x 1860 x 1805 mm (W x D x H)
Temperature Range: -10 °C to +90 °C
Humidity Range: 10 to 98 % RH
Dew Point Range: +4 °C to +89.5 °C
Temperature Homogeneity: ±0.5 to ±1 K
Temperature Deviation: ±0.1 to ±0.5 K
Heating Rate: approx. 1 K/min
Cooling Rate: approx. 0.3 K/min
Max. Heat Compensation: approx. 200 W
Refrigerant: R404A
Filling Quantity: 0.6 kg
ND max.: 25 bar g
HD max.: 25 bar g
Power Connection: 230 V / 50 Hz
Rated Power: 2.3 kW
Rated Current: 10 A
Protection Class: IP54
Weight: approx. 490 kg
Iiodpfozgb Awex Af Esd
Equipment
SIMPAC control system
Temperature and humidity control
Stainless steel test chamber
Ethernet, USB, RS232, RS485/422
Test item protection function
Cable glands
Application Areas
Climate testing
Temperature testing
Material testing
Electronics testing
Quality assurance
Research and development
Scope of Supply
Vötsch VC³ 0034 Climate Test Chamber
Accessories as shown in the pictures
Condition
Used
Optical condition as shown in the pictures
For the safety of our customers, the offered climate chambers are tested before delivery,
if necessary, filled with legally compliant refrigerant, subjected to a leak test,
and delivered with a documented test run.
Subject to change and errors in technical data as well as prior sale.
Listing
Borken
7,009 km
Climate test chamber with humidity, 335 liters
WeissWK3-340/40 -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss climate testing chamber.
Weiss climate testing chamber, water-cooled
(Refrigerant converted to R-452A)
Temperature testing
Volume 335 liters
Test chamber dimensions:
Test chamber dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Minimum temperature -42°C
Maximum temperature +180°C
Iiedpfx Afozgavvj Eod
Temperature change rate, cooling 4 K/min
Temperature change rate, heating 3.2 K/min
Temperature deviation, time-based ± 0.1 to ± 0.5 K
Temperature homogeneity, spatially ± 0.5 to ± 1.5 K
Climate testing:
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range 10 to 98% RH
Temperature deviation, time-based ± 0.1 to ± 0.3 K
Temperature homogeneity, spatially ± 0.5 to ± 1 K
Humidity deviation, time-based ± 1 to ± 3 % RH
Voltage: 3/N/PE AC 400V±10% 50Hz
Rated power 4.1 kW Rated current: 14 A
Refrigerant: R-452A
Type: WK3-340/40
Weight Approx. 515 kg
For your security as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Climate test chamber with humidity
WeissSB2/500/80 -75°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss climate test chamber.
Designation: SB2/500/80, water-cooled
Cold-heat operation: -75°C ... +180°C
Climate operation: +10...+95°C
Humidity range: 10...98 % RH
Temperature stability, over time: ± 0.2K
Humidity stability: ±1 % RH
Temperature change rate:
Cooling: approx. 1.4 K/min
Heating: approx. 2.5 K/min
External dimensions: Height 1980 mm, Width 1265 mm, Depth 1365 mm
Connections:
left side: ∅ 100 mm
right side: ∅ 50 mm
The connection voltage is:
400V/3Ph+N+PE/50 Hz
Power: 10.4 kVA
Weight: approx. 720 kg
Isdszd Ultjpfx Af Ejid
Refrigerant: R404a / R23
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leakage test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: SB2/500/80
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data and information are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Climate test chamber with humidity control
Feutron3707/06 Temp. -40°C bis 150°C
Call
Condition: excellent (used), Here we offer a Feutron climate test chamber.
Feutron Climate Test Chamber
Temperature
Temperature range: -40...90°C
Climatic range (without heat load): 10...85°C
Temporal temperature deviation during temperature operation: ≤ ± 0.5 K/min
Temporal temperature deviation during climatic operation: ± 1.0... ± 1.5 K/min
Change rates
Heating: avg. 2.0 K/min
Cooling: avg. 2.0 K/min
Standard IEC 1646 is achievable with testing, solar modules up to max. 160kg weight and nonlinear ramps (setpoint jump)
Drying
Air drying: condensation drying
Humidity
Air humidification: steam humidification
Humidity range: 10...95 % r.h.
Temporal humidity deviation: ≤ ± 3.0... ±5.0 % r.h.
Dew point range: 8...80.9°C
Test Chamber
Test chamber volume: 7.0 m³
Dimensions
Internal dimensions: Width 1500 mm x Height 2250 mm x Depth 2000 mm
Swing door DIN right, heated, Width 900 mm x Height 2100 mm
Observation window, heated, with blackout shutter and lockable: Width 500 mm x Height 600 mm
Feedthrough: 2x, right front side, Ø 75 mm
Irradiation unit, test chamber
Opening: 4x in left side wall for SC 2500, each 850 x 700 mm
Irradiated area when using SC 2500: 1200 x 1200 mm
Radiation intensity at 1.0 m wall distance: 1000 ± 10% W/m²
Lighting: 1x halogen lamp, 200W
Refrigeration system: Bitzer compressor, semi-hermetic, 2-stage, air cooled
Condenser: split condenser (outdoor installation, winter control)
Refrigerant: R507 / R23
Temperature control system
Coolant medium Tyfocor / water
Mixing ratio 50/50%
Coolant density: 1.072 kg/dm³
Filling quantity: approx. 80 dm³
Pyranometer
Temperature range: -40...150°C
Max. radiation absorption: 4000 W/m²
Spectral range (50% points): 305...2800 nm
Sensitivity (nominal): 7 µV/W/m²
Power supply, test chamber
Mains connection: 400V, 3/N/PE, AC, 50Hz
Connection type: hardwired
Max. simultaneous power demand: approx. 32.0 kW
Supply fuse: 3 x 63, Char C (A)
Power supply, SolarConstant
Mains connection: 400V, 3/N/PE, AC, 50Hz
Connection type:
Max. simultaneous power demand: approx. 30.0 kW
Supply fuse: 3 x 63, Char C (A)
Overall external dimensions of the test cell including: equipment room/control cabinet and control cabinet for SolarConstant 2500
External dimensions equipment room: Width 3440 mm x Height 2580 mm x Depth 2950 mm
/control cabinet: Width 2200 mm x Height 1830 mm x Depth 1100 mm
External dimensions condenser, split: Width 900 mm x Height 950 mm x Depth 2000 mm
Weight test chamber (total): approx. 2700 kg
Condenser empty weight: 153 kg
Weight: 2700 kg
Type: 3707/06
Condition: used
Iiodpezd Sdgjfx Af Eed
Scope of delivery: (see picture)
(Technical data and information are subject to change and errors!)
For further questions, we are happy to assist you by phone.
Listing
Borken
7,009 km
Climate test chamber 335 liters with humidity
VötschVC 4034 -40°C..+180°C
Call
Condition: excellent (used), Vötsch VC 4034 Climate Chamber / Temperature Chamber
Description:
For sale is a used climate and temperature chamber from the manufacturer Vötsch Industrietechnik.
This unit is suitable for demanding temperature and climate tests in research, development,
quality assurance, the electronics industry, automotive technology, as well as material and aging tests.
The test chamber has been converted to the modern refrigerant R452A and features a user-friendly
touch panel control.
Iiedezd Dm Hjpfx Af Ejd
Thanks to the large test chamber volume of approximately 335 liters, the system is suitable for both individual test specimens and
for extensive test setups.
Technical data:
Manufacturer: Vötsch Industrietechnik GmbH
Type: VC 4034
Test chamber volume: approx. 335 liters
Test chamber dimensions: approx. 580 x 765 x 750 mm (W x D x H)
External dimensions: approx. 780 x 1758 x 1800 mm (W x D x H)
Weight: approx. 515 kg
Temperature range: -40 °C to +180 °C
Temperature deviation over time: ±0.1 to ±0.5 K
Temperature homogeneity spatially: ±0.5 to ±1.5 K
Heating rate: approx. 3.2 K/min
Cooling rate: approx. 3.5 K/min
Climate operation:
Temperature range: -40 °C to +180 °C
Humidity range: 10 % to 98 % RH
Temperature deviation over time: ±0.1 to ±0.3 K
Temperature homogeneity spatially: ±0.5 to ±1.0 K
Refrigerant: R452A
Filling quantity: 2.5 kg
GWP: 2141
CO₂ equivalent: 5.35 t
ND max.: 22 bar(g)
HD max.: 25 bar(g)
Power connection: 3/N/PE AC 400 V ±10 % / 50 Hz
Rated power: 4.1 kW
Rated current: 12.5 A
Equipment:
Touch panel control
Programmable test sequences
Stainless steel interior
Viewing window in the door
Test chamber lighting
Air circulation system
Side feedthrough for measuring cables
Several stainless steel insert shelves
Air-cooled refrigeration system
Documentation available
Application areas:
Temperature testing
Climate testing
Material testing
Electronics testing
Aging tests
Environmental simulation
Quality assurance
Research and development
Automotive testing
Condition:
Used
Optical condition as shown in the pictures.
Maintenance and calibration stickers are present.
Refrigeration circuit converted to R452A.
Scope of supply:
1x Vötsch VC 4034 Climate Chamber
Stainless steel insert shelves
Touch panel control unit
Documentation / Documents
Accessories as shown in the pictures
Subject to changes and errors in the technical data.
Subject to prior sale.
Listing
Borken
7,009 km
Climate test chamber with humidity control
BinderMKFT 720 E3.2 -70°C bis 180°C
Call
Condition: excellent (used), Binder MKFT 720 E3.2 Temperature and Humidity Chamber
Device Data
Manufacturer: Binder
Type: MKFT 720 E3.2
Year of Construction: 2017
Article Number: 9020-0288
Design: Temperature and Humidity Chamber
Cooling: Air-cooled
Description
Used temperature and humidity chamber from Binder.
Suitable for temperature, climate, material, and aging tests, as well as stress tests.
Application in industry, research, development, and quality assurance.
Technical Data
Temperature range: -70 °C to +180 °C
Humidity range: 10 % to 98 % RH
Internal volume: approx. 734 liters
Max. total load: 160 kg
Max. load per shelf: 40 kg
Dimensions
External (W x H x D): 1615 x 2005 x 1230 mm
Internal (W x H x D): 1200 x 1020 x 600 mm
Electrical Data
400 V / 3N~ / 50 Hz
Power: 13.0 kW
Current: 22.5 A
Protection class: IP 20
Iodpfjy H H Smex Af Eoid
Refrigeration System
Refrigerant: R404A / R23
Stage 1: 4.00 kg
Stage 2: 0.87 kg
Two-stage refrigeration system
Max. operating pressure: 29 bar
Performance Data Temperature
Temperature deviation over time: 0.1 to 0.5 K
Temperature deviation spatially: 0.3 to 2.0 K
Heating rate: approx. 4.8 K/min
Cooling rate: approx. 4.0 K/min
Heat compensation: approx. 5000 W
Performance Data Climate
Climate range: +10 °C to +95 °C
Humidity range: 10 % to 98 % RH
Temperature deviation: 0.1 to 1.0 K
Heat compensation: approx. 800 W
Equipment
Touch control panel
Program and constant operation
Observation window
Stainless steel test chamber
Internal lighting
Cable entry
Movable on rollers
Robust industrial design
Weight approx. 635 kg
Scope of Supply
Binder MKFT 720 E3.2 Temperature and Humidity Chamber
Scope of supply as shown in the pictures
Functional testing
Refrigerant service
Leak test
Test run with protocol
Condition: Used.
Condition: See pictures.
Inspection possible by arrangement.
Loading and transport can be organized upon request.
Subject to changes and prior sale.
If you have any questions, please do not hesitate to contact us.
Listing
Borken
7,009 km
Climatic test chamber with humidity, 600 liters
RS-SimulatorenKSS600/75-10K -75°C bis +180°C
Call
Condition: excellent (used), RS-Simulators Climate Chamber KSS 600/75-10K
Device Data
Manufacturer: RS-Simulators Prüf- und Messtechnik GmbH
Type: KSS 600/75-10K
Design: Climate test chamber / Environmental simulation chamber
Cooling: Water-cooled
Description
Used climate test chamber from RS-Simulators.
Suitable for temperature tests, climate tests, material and aging tests.
Application in industrial testing and measurement.
Technical Data
Temperature range: -75 °C to +180 °C
Temperature change: Heating/cooling approx. 10 K/min
Test chamber volume: approx. 600 liters
Dimensions
Internal (W x D x H): 840 x 840 x 840 mm
External (W x D x H): 1200 x 1600 x 1995 mm
Electrical Data
400 V / 3~ / N / PE
Current consumption: approx. 55 A
Refrigeration System
Refrigerant: R404A / R23
R404A: 6.0 kg
R23: 3.0 kg
Weight
approx. 1400 kg
Equipment
RS-Simulators control panel / operating panel
Program operation
Observation window
Temperature monitoring in the test chamber
Operating hour counter
Side feed-through
Iijdpfsy H Ib Ajx Af Esd
Robust industrial design
Scope of delivery
RS-Simulators climate chamber KSS 600/75-10K
Scope of delivery as shown in the pictures
Functional test
Refrigerant service
Leak test
Condition: Used.
Condition: See pictures.
Inspection possible by arrangement.
Loading and transport can be organized upon request.
Subject to changes and prior sale.
If you have any questions, please do not hesitate to contact us.
Listing
Amstetten
6,423 km
Weiss climate test chamber SB11/300/40 -40..
WEISSSB11/300/40
Call
Year of construction: 1995, condition: excellent (used), functionality: fully functional, machine/vehicle number: SB11/300/40, For sale is a Weiss climate test chamber.
Designation: SB11/300/40
Cooling-heating operation: -40...+180 °C
Climate operation: +10...+95 °C
Humidity range: 10...98 % RH
Temperature stability
The temporal temperature stability in climate mode is ±0.1...±0.5 K
The temporal temperature stability in cooling-heating mode (without climate) is ±0.2...±0.5 K
Humidity stability
The temporal humidity stability across the entire operating range is ±2...±3 %RH
Condenser: air-cooled
Rate of temperature change:
Cooling: approx. 3.1 K/min
Heating: approx. 3 K/min
Test chamber volume: approx. 301 L
Internal dimensions: Height 680 mm, Width 540 mm, Depth 820 mm
External dimensions: Height 1700 mm, Width 800 mm, Depth 1780 mm
Weight: approx. 420 kg / Power supply: 4.8 kVA
Electrical connection: CEE plug 16 A
Iisdew Dygfopfx Af Eod
Connection voltage:
400V/3Ph+N+PE/50 Hz (+6%/-10%)
Refrigerant: R404A!
Version: mobile
Type: SB11/300/40
Listing
Wymysłów
6,232 km
Vötsch VTL 7010 – climate chamber / temperature test chamber
Vötsch VTL 7010 – komora klimatyczna / komora do badań temperaturowychVötsch VTL 7010 – komora klimatyczna / komora do badań temperaturowych
Call
Condition: excellent (used), For sale is a professional Vötsch VTL 7010 climate chamber, designed for conducting temperature tests and simulating environmental conditions. The device is used in laboratories, quality control departments, research and development centers, and for testing electronic, automotive, and mechanical components.
The chamber is in good working order – the touchscreen starts up correctly and displays the main menu and the current operating temperature, as confirmed by the photos.
Technical specifications:
Manufacturer: Vötsch Industrietechnik GmbH
Model: VTL 7010
Year of manufacture: 2010
Iisdpszi T Nhjfx Af Eod
Temperature range: -70°C to +180°C
Heating/cooling rate: approx. 3.5 K/min
Refrigerant:
R404A – 0.8 kg
R23 – 0.2 kg
Power supply: 230 V AC, 50 Hz
Rated power: 3.5 kW
Rated current: 15.2 A
Operating pressure: 8 bar
Control via a color touchscreen
Working chamber made of stainless steel
Door with a viewing window
Adjustable internal shelves
CE marking
Applications
The device is ideally suited for:
temperature tests,
material testing,
testing electronics and components,
durability tests,
quality control,
research and development work.
Condition:
used,
functional,
control panel operates correctly,
internal chamber is clean and well-maintained,
normal signs of wear and tear,
sold exactly as shown in the pictures.
Included:
Vötsch VTL 7010 climate chamber,
2 perforated shelves,
built-in control panel.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
7,009 km
Climate test chamber 256 liters
MemmertCTC 256 -42 bis +190°C
Call
Condition: excellent (used), Memmert GmbH
Climate Testing Chamber / Temperature Testing Chamber
Used Memmert climate testing chamber, type CTC 256, for temperature and climate testing. This unit is suitable for environmental simulation, material testing, quality assurance, research and development, as well as stress and aging tests.
Technical data:
Manufacturer: Memmert GmbH + Co. KG
Type: CTC 256
Test chamber volume: approx. 256 liters
Test chamber dimensions: approx. 640 x 597 x 670 mm (W x D x H)
Housing dimensions: approx. 898 x 1100 x 1730 mm (W x D x H)
Weight: approx. 320 kg
Temperature range: -42 °C to +190 °C
Heating rate: approx. 3.35 K/min
Cooling rate: approx. 2.8 K/min
Humidity function available
Refrigerant: R404A
Rated cooling capacity: 2.53 kW
Max. operating overpressure: 30 bar
Mains connection: 3/N/PE AC 400 V / 50 Hz
Rated power: approx. 7.0 kW
Rated current: approx. 10.6 A
Equipment
Programmable controller
Viewing window
Stainless steel interior
Air circulation system
Ethernet interface
Printer connection
Alarm contact
230 V service socket
Shelf insert
Documentation available
Scope of delivery
Memmert CTC 256 climate testing chamber
Shelf insert
Water canister
Documentation / test report
Accessories as shown in the pictures
Isdezlidtepfx Af Esid
Condition
Used, optical condition according to the pictures.
(Changes and errors in the technical data are subject to change!)
Subject to prior sale.
Listing
Borken
7,009 km
Climatic test chamber 1000 liters
Erichsen KorrosionsprüfanlageCORROCOMPACT 618-1000
Call
Condition: excellent (used), ERICHSEN CORROCOMPACT 618-1000 Corrosion Testing System
Manufacturer: ERICHSEN GmbH & Co. KG
Type: CORROCOMPACT 618-1000
Year of Manufacture: 2017
Machine Type: Corrosion Testing System / Climate Change Testing System
Test Chamber Volume: 1,000 liters
For sale is a used ERICHSEN CORROCOMPACT 618-1000 corrosion testing system with a separate air conditioning unit and Siemens SIMATIC touch control.
The system was developed for professional corrosion, climate change, salt spray, and condensation tests and is ideally suited for testing laboratories, the automotive industry, research institutions, and quality assurance.
Technical Data:
Model: 618-1000
Series: CORROCOMPACT 617
Serial Number: 16855/005
Test Chamber Volume: 1,000 liters
Power Supply: 3+N+PE AC 400 V / 50 Hz
Connected Load: 5 kVA + 9 kVA (air conditioning unit)
Fuse Rating: 3 × 32 A
Compressed Air Connection: 6–10 bar
Deionized Water Connection: 3–6 bar
Control: Siemens SIMATIC HMI Touch
CPU Version: 2.2.3
HMI Version: 2.2.3
Air Conditioning Unit:
Manufacturer: ERICHSEN
Type: VS-Bo-1,1-40-L-S
Year of Manufacture: 2014
Serial Number: 14-2430
Refrigerant: R507
Connected Load: 3.3 kW
Max. Operating Current: 8.4 A
Compressor Power: 1.3 kW
Evaporator Fan: 0.18 kW
Condenser Fan: 0.28 kW
Steam Humidifier: 1.6 kW
Heater: 5 × 0.2 kW
Dimensions:
External Dimensions (W × D × H): approx. 2,100 × 1,350 × 1,670 mm
Height with Hood Open: approx. 2,500 mm
Internal Dimensions (W × D × H): approx. 1,190 × 815 × 1,040 mm
Equipment:
Siemens SIMATIC Touch Panel
Separate Air Conditioning Unit
1,000-Liter Test Chamber
Climate Change Testing
Salt Spray Testing
Condensation Testing
Automatic Test Programs
Compressed Air Connection
Deionized Water Connection
Salt Solution Connection
Exhaust Connection
Floor Drain
Supported Test Standards:
DIN EN ISO 11997-1
DIN EN ISO 6270-2 AT
ISO 11503
ASTM D2247
VDA 621-415 B
P-VW 1210
DIN EN ISO 9227 NSS
VDA 233-102
DIN EN ISO 6270-2 AHT
DIN EN ISO 9227 AASS
DIN EN ISO 9227 CASS
ASTM B117
D171058
DIN EN ISO 6270-2 CH
Ijdpfx Afszk A Ebe Eeid
DIN 50958
ISO 9227
BS 3900 Part F2
DIN 55991
Transport Data:
Test Chamber (W × D × H): approx. 2,100 × 1,350 × 1,670 mm
Air Conditioning Unit (W × D × H): approx. 1,700 × 900 × 1,900 mm
Weight of Test Chamber: approx. 600 kg
Weight of Air Conditioning Unit: approx. 500 kg
Total Weight: approx. 1,100 kg
Condition:
Used
The system was last used in an industrial setting.
Optical condition according to the pictures.
Scope of Delivery:
ERICHSEN CORROCOMPACT 618-1000
Air Conditioning Unit VS-Bo-1,1-40-L-S
Siemens SIMATIC HMI Touch
Accessories according to the pictures
Availability: by arrangement.
Scope of delivery as shown in the pictures.
Subject to change, errors and prior sale.
Listing
Borken
7,009 km
Climatic test chamber -42 to +190°C
MemmertCTC 256 256 Liter
Call
Condition: excellent (used), Memmert
Type: CTC 256
Memmert Climate Test Chamber CTC 256
Temperature & Humidity Test Chamber
Industrial Quality
For sale is a high-quality climate test chamber / temperature test chamber
from the manufacturer Memmert, model CTC 256.
The unit originates from professional use and is ideally suited for laboratories,
industry, research, development as well as quality assurance.
The Memmert CTC 256 is designed for precise simulation of temperature and climatic conditions.
It enables both cooling and heating processes and – in this configuration – humidity control.
This makes the unit perfect for material testing, aging tests, climatic stress tests,
and long-term experiments under defined environmental conditions.
Thanks to the integrated control system, complex test programs with temperature and time sequences can be set.
The forced air circulation system ensures uniform temperature distribution in the chamber interior.
Via the available interfaces, measurement data can be documented and processed externally.
Features:
Temperature and climate test chamber (heating & cooling)
- Humidity control
Electronic controller with programmable function
Forced air system for even temperature distribution
Internal protocol memory
USB and Ethernet interface
Additional 230 V socket
Feed-through (side)
Water container system (humidification/condensate)
Mobile on castors
Technical Data:
Manufacturer: Memmert
Model: CTC 256
Device type: Climate test chamber
Temperature range: approx. -42 °C to +190 °C
Internal volume: approx. 256 liters
Operating voltage: 3N~ 400 V / 50 Hz
Current consumption: approx. 10.6 A
Power consumption: approx. 7000 W
Protection class: IP20
External dimensions (approx.): 898 x 1730 x 1100 mm (W x H x D)
Internal dimensions (approx.): 640 x 670 x 597 mm (W x H x D)
Weight: approx. 300–350 kg
Condition: used
Scope of delivery: (see photo)
Memmert CTC 256 climate test chamber
Removable shelves
Water canister
Documents
Delivery as shown
Iijdpfx Afey D Ni Aj Eod
(Specifications and technical data are subject to change and error!)
If you have any further questions, we would be happy to assist you by phone.
Listing
Borken
7,009 km
Climatic chamber temperature and humidity
EspecPL-3KPH -40°C bis 180°C
Call
Condition: excellent (used), ESPEC Climate Testing Chamber PL-3KPH
Device Data
Manufacturer: ESPEC
Type: PL-3KPH
Design: Climate Testing Chamber
Cooling: Air-cooled
Description
Used climate testing chamber from ESPEC.
Suitable for temperature and humidity testing.
Used in research, development, and quality assurance.
Operating Status
Display: STOP / ready for operation.
Technical Data
Model: PL-3KPH
Test chamber volume: approx. 400 liters
Temperature range: -40 °C to +180 °C
Temperature change rate (heating): approx. 3.4 K/min
Temperature change rate (cooling): approx. 1.7 K/min
Temperature stability (-40 °C to +100 °C): ±0.3 K
Temperature stability (+100.1 °C to +150 °C): ±0.5 K
Temperature stability (+150.1 °C to +180 °C): ±1.0 K
Humidity range: 20 to 98 % RH
Humidity stability: ±2.5 % RH
Dimensions
Internal (W x H x D): 600 x 850 x 800 mm
External (W x H x D): 1010 x 1690 x 1195 mm
Electrical Data
400 V / 3~ / 50 Hz
Refrigeration System
Refrigerant: R404A
Air-cooled (no external water connection required)
Weight approx. 350 kg
Equipment
Touchscreen control panel
Program and constant operation
BTHC temperature and humidity control
Observation window
Stainless steel test chamber
Internal lighting
Cable gland
Overheating protection
Hour meter
Industrial design
Scope of supply
ESPEC Climate Testing Chamber PL-3KPH
Scope of supply as shown in the images
Iisdoy H H Iujpfx Af Ejd
Service before delivery (optional)
Functional test
Refrigerant service
Leakage test
Test run with protocol
Condition
Used.
Condition see images.
Note
Loading and transport can be arranged upon request.
Subject to changes and prior sale.
If you have any questions, please do not hesitate to contact us.
We make it easier for you to find: "weiss climate test chamber with humidity"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month