Used Weiss Climeevent C/340/70/5 for sale (93,098)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Success:
Your message has been sent.
Listing
Borken
7,009 km
Vötsch ClimeEvent C/340/70/5 climate test chamber -70°C to +180°C, 340 liters, with humidity control
WeissClimeEvent C/340/70/5
Call
Condition: used, Vötschtechnik
Climate testing chamber / Temperature testing chamber
Vötschtechnik ClimeEvent C/340/70/5
Temperature and climate testing chamber, water-cooled
For sale is a used climate testing chamber from Vötschtechnik GmbH.
The testing chamber is suitable for temperature and climate tests, environmental simulation, material testing, quality assurance, as well as development and stress tests.
Technical data
Manufacturer: Vötschtechnik GmbH
Type: ClimeEvent C/340/70/5
Device type: Climate testing chamber / Temperature testing chamber
Year of manufacture: 2018
Test chamber volume: approx. 340 liters
Weight: approx. 650 kg
External dimensions (H x W x D): approx. 1830 x 900 x 1890 mm
Internal dimensions (H x W x D): approx. 750 x 580 x 765 mm
Temperature range: -70 °C to +180 °C
Temperature change rate (heating): approx. 7 K/min
Temperature change rate (cooling): approx. 7 K/min
Max. heat compensation: approx. 3000 W
Temperature deviation (over time): ±0.1 to ±0.5 K
Temperature homogeneity (spatial): ±0.5 to ±1 K
Temperature gradient: ≤2 K
Climate range (temperature): +10 °C to +95 °C
Dew point range: -3 °C to +94 °C
Humidity range: 10 to 98 % RH
Humidity deviation (over time): ±1 to ±3 % RH
Temperature deviation (over time, climate operation): ±0.1 to ±0.3 K
Temperature homogeneity (spatial, climate operation): ±0.5 to ±1 K
Refrigerant: R449A / R23
Refrigerant quantity: 2.50 kg / 0.75 kg
Power connection: 3/N/PE AC 400 V ±10 % / 50 Hz
Rated power: 9 kW
Rated current: 20 A
Sound pressure level: approx. 57 dB(A)
Equipment
Touchscreen control
Interior made of stainless steel
Large viewing window
Interior lighting
Water-cooled design
Lateral cable entry
Multiple shelf levels
Ethernet interface
USB interface
Accessories as shown in the pictures
Applications
Temperature testing
Climate testing
Environmental simulation
Material testing
Electronics testing
Quality assurance
Research and development
Condition
Used
Visual condition as shown in the pictures
Scope of delivery
Hnsdpfszrwyiex Akreu
1x Vötschtechnik ClimeEvent C/340/70/5 climate testing chamber
Accessories as shown in the pictures
Important note:
For the safety of our customers, the following work will be carried out on the offered climate chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant if necessary
3. Leak test with certificate
4. Documented test run after successful inspection
The table or other items not explicitly mentioned in the photos are not part of the sale.
Shipping or forwarding possible.
Subject to changes, errors and prior sale.
We are happy to answer any further questions by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Vötsch ClimeEvent C/340/70/5 climate test chamber -70°C to +180°C, 340 liters, with humidity control
WeissClimeEvent C/340/70/5
Call
Condition: used, Vötschtechnik
Climate test chamber / Temperature test chamber
Vötschtechnik ClimeEvent C/340/70/5
Temperature and climate test chamber, water-cooled
Hnsdpfx Aozrtz Askreu
For sale is a used climate test chamber
from the manufacturer Vötschtechnik GmbH.
The test chamber is suitable for temperature and climate tests,
environmental simulation, material testing, quality assurance,
as well as development and stress tests.
Technical data
Manufacturer: Vötschtechnik GmbH
Type: ClimeEvent C/340/70/5
Device type: Climate test chamber / Temperature test chamber
Year of manufacture: 2018
Test chamber volume: approx. 340 liters
Weight: approx. 650 kg
External dimensions (H × W × D): approx. 1830 × 900 × 1890 mm
Internal dimensions (H × W × D): approx. 750 × 580 × 765 mm
Temperature range: -70 °C to +180 °C
Temperature change rate (heating): approx. 7 K/min
Temperature change rate (cooling): approx. 7 K/min
Max. heat compensation: approx. 3000 W
Temperature deviation (time): ±0.1 to ±0.5 K
Temperature homogeneity (spatial): ±0.5 to ±1 K
Temperature gradient: ≤2 K
Climate range (temperature): +10 °C to +95 °C
Dew point range: -3 °C to +94 °C
Humidity range: 10 to 98 % RH
Humidity deviation (time): ±1 to ±3 % RH
Temperature deviation (time, climate operation): ±0.1 to ±0.3 K
Temperature homogeneity (spatial, climate operation): ±0.5 to ±1 K
Refrigerant: R449A / R23
Refrigerant quantity: 2.50 kg / 0.75 kg
Power connection: 3/N/PE AC 400 V ±10 % / 50 Hz
Rated power: 9 kW
Rated current: 20 A
Sound pressure level: approx. 57 dB(A)
Equipment
Touchscreen control
Interior made of stainless steel
Large viewing window
Interior lighting
Water-cooled design
Side cable entry
Several shelf levels
Ethernet interface
USB interface
Accessories as shown in the pictures
Application areas
Temperature testing
Climate testing
Environmental simulation
Material testing
Electronics testing
Quality assurance
Research and development
Condition
Used
Optical condition as shown in the pictures
Scope of supply
1x Vötschtechnik ClimeEvent C/340/70/5 climate test chamber
Accessories as shown in the pictures
Important note:
For the safety of our customers, the following work will be carried out on the offered climate chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leakage test with certificate
4. Documented test run after successful inspection
The table shown in the photos or other items not explicitly mentioned
are not part of the sale.
Shipping or freight transport possible.
Subject to changes, errors and prior sale.
We will be happy to answer any further questions by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Vötsch ClimeEvent C/340/70/5 climate test chamber -70°C to +180°C, 340 liters, with humidity control
WeissClimeEvent C/340/70/5
Call
Condition: used, Vötschtechnik
Climate chamber / Temperature chamber
Vötschtechnik ClimeEvent C/340/70/5
Temperature and climate chamber, water-cooled
For sale is a used climate chamber from Vötschtechnik GmbH.
The chamber is suitable for temperature and climate testing, environmental simulation, material testing, quality assurance, and development and stress testing.
Technical data
Manufacturer: Vötschtechnik GmbH
Type: ClimeEvent C/340/70/5
Device type: Climate chamber / Temperature chamber
Year of manufacture: 2018
Test chamber volume: approx. 340 liters
Weight: approx. 650 kg
External dimensions (H x W x D): approx. 1830 x 900 x 1890 mm
Internal dimensions (H x W x D): approx. 750 x 580 x 765 mm
Temperature range: -70 °C to +180 °C
Temperature change rate (heating): approx. 7 K/min
Temperature change rate (cooling): approx. 6.7 K/min
Max. heat compensation: approx. 3000 W
Temperature deviation (over time): ±0.1 to ±0.5 K
Temperature homogeneity (spatially): ±0.5 to ±1 K
Temperature gradient: ≤2 K
Climate range (temperature): +10 °C to +95 °C
Dew point range: -3 °C to +94 °C
Humidity range: 10 to 98 % RH
Humidity deviation (over time): ±1 to ±3 % RH
Temperature deviation (over time, climate mode): ±0.1 to ±0.3 K
Temperature homogeneity (spatially, climate mode): ±0.5 to ±1 K
Refrigerant: R449A / R23
Refrigerant quantity: 2.50 kg / 0.75 kg
Power connection: 3/N/PE AC 400 V ±10 % / 50 Hz
Rated power: 8.6 kW
Rated current: 21 A
Sound pressure level: approx. 57 dB(A)
Features
Touchscreen control
Interior made of stainless steel
Large viewing window
Interior lighting
Water-cooled design
Side cable entry
Multiple insertion levels
Ethernet interface
USB interface
Accessories according to images
Application areas
Temperature testing
Climate testing
Environmental simulation
Material testing
Electronics testing
Hodpfjznvxiox Akronu
Quality assurance
Research and development
Condition
Used
Optical condition according to images
Scope of supply
1x Vötschtechnik ClimeEvent C/340/70/5 climate chamber
Accessories according to images
Important note:
For the safety of our customers, the following work will be carried out on the offered climate chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. Documented test run after successful inspection
The table shown in the photos and any other items not explicitly mentioned are not included in the sale.
Shipping or freight forwarding possible.
Subject to change, errors and prior sale.
We will be happy to answer any further questions by telephone.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Success:
Your message has been sent.
Listing
Borken
7,009 km
Vötsch ClimeEvent C/340/70/5 climate test chamber -70°C to +180°C, 340 liters, with humidity control
WeissClimeEvent C/340/70/5
Call
Condition: used, Vötschtechnik
Climate test chamber / Temperature test chamber
Hedpfx Aezznx Iokrjnu
Vötschtechnik ClimeEvent C/340/70/5
Temperature and climate test chamber, water-cooled
For sale is a used climate test chamber from Vötschtechnik GmbH.
The test chamber is suitable for temperature and climate tests, environmental simulation, material testing, quality assurance, as well as development and stress tests.
Technical data
Manufacturer: Vötschtechnik GmbH
Type: ClimeEvent C/340/70/5
Device type: Climate test chamber / Temperature test chamber
Year of construction: 2018
Test chamber volume: approx. 340 liters
Weight: approx. 650 kg
External dimensions (H x W x D): approx. 1830 x 900 x 1890 mm
Internal dimensions (H x W x D): approx. 750 x 580 x 765 mm
Temperature range: -70 °C to +180 °C
Temperature change rate (heating): approx. 7 K/min
Temperature change rate (cooling): approx. 6.7 K/min
Max. heat compensation: approx. 3000 W
Temperature deviation (time): ±0.1 to ±0.5 K
Temperature homogeneity (spatial): ±0.5 to ±1 K
Temperature gradient: ≤2 K
Climate range (temperature): +10 °C to +95 °C
Dew point range: -3 °C to +94 °C
Humidity range: 10 to 98 % RH
Humidity deviation (time): ±1 to ±3 % RH
Temperature deviation (time, climate operation): ±0.1 to ±0.3 K
Temperature homogeneity (spatial, climate operation): ±0.5 to ±1 K
Refrigerant: R449A / R23
Refrigerant quantity: 2.50 kg / 0.75 kg
Power connection: 3/N/PE AC 400 V ±10 % / 50 Hz
Rated power: 9 kW
Rated current: 20 A
Sound pressure level: approx. 57 dB(A)
Equipment
Touchscreen control
Stainless steel interior
Large viewing window
Interior lighting
Water-cooled version
Side cable entry
Multiple shelf levels
Ethernet interface
USB interface
Accessories as shown in the pictures
Application areas
Temperature testing
Climate testing
Environmental simulation
Material testing
Electronics testing
Quality assurance
Research and development
Condition
Used
Optical condition as shown in the pictures
Scope of supply
1x Vötschtechnik ClimeEvent C/340/70/5 climate test chamber
Accessories as shown in the pictures
Important note:
For the safety of our customers, the following work will be carried out on the offered climate chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leakage test with certificate
4. Documented test run after successful inspection
Shipping or freight forwarding possible.
Subject to changes, errors and prior sale.
We will gladly answer any further questions by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Vötsch ClimeEvent C/340/70/5 climate test chamber -70°C to +180°C, 340 liters, with humidity control
WeissClimeEvent C/340/70/5
Call
Condition: used, Vötschtechnik
Climate test chamber / Temperature test chamber
Vötschtechnik ClimeEvent C/340/70/5
Temperature and climate test chamber, water-cooled
For sale is a used climate test chamber from Vötschtechnik GmbH.
The test chamber is suitable for temperature and climate tests, environmental simulation, material testing, quality assurance, as well as development and stress tests.
Technical data
Manufacturer: Vötschtechnik GmbH
Type: ClimeEvent C/340/70/5
Device type: Climate test chamber / Temperature test chamber
Year of construction: 2018
Test chamber volume: approx. 340 liters
Weight: approx. 650 kg
External dimensions (H x W x D): approx. 1830 x 900 x 1890 mm
Internal dimensions (H x W x D): approx. 750 x 580 x 765 mm
Temperature range: -70 °C to +180 °C
Temperature change rate (heating): approx. 7 K/min
Temperature change rate (cooling): approx. 6.7 K/min
Max. heat compensation: approx. 3000 W
Temperature deviation (time): ±0.1 to ±0.5 K
Temperature homogeneity (spatial): ±0.5 to ±1 K
Temperature gradient: ≤2 K
Climate range (temperature): +10 °C to +95 °C
Dew point range: -3 °C to +94 °C
Humidity range: 10 to 98 % RH
Humidity deviation (time): ±1 to ±3 % RH
Temperature deviation (time, climate operation): ±0.1 to ±0.3 K
Temperature homogeneity (spatial, climate operation): ±0.5 to ±1 K
Refrigerant: R449A / R23
Refrigerant quantity: 2.50 kg / 0.75 kg
Power connection: 3/N/PE AC 400 V ±10 % / 50 Hz
Rated power: 9 kW
Rated current: 20 A
Sound pressure level: approx. 57 dB(A)
Equipment
Touchscreen control
Stainless steel interior
Large viewing window
Interior lighting
Water-cooled version
Side cable entry
Multiple shelf levels
Ethernet interface
USB interface
Accessories as shown in the pictures
Application areas
Temperature testing
Climate testing
Environmental simulation
Material testing
Electronics testing
Quality assurance
Research and development
Condition
Used
Optical condition as shown in the pictures
Scope of supply
1x Vötschtechnik ClimeEvent C/340/70/5 climate test chamber
Accessories as shown in the pictures
Important note:
For the safety of our customers, the following work will be carried out on the offered climate chambers in advance:
Hsdpjzzag Dofx Akronu
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leakage test with certificate
4. Documented test run after successful inspection
Shipping or freight forwarding possible.
Subject to changes, errors and prior sale.
We will gladly answer any further questions by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Climate test chamber C 340 liters, year of manufacture 2019
Vötschtechnik ClimeEventC/340/70/5/S -70°C bis +180°C
Call
Year of construction: 2019, condition: excellent (used), Vötsch ClimeEvent C/340/70/5/S Climate Testing Chamber (Special Edition)!!
Hsdpfx Ajzp Nv Dokrsnu
Manufacturer: Vötsch Industrietechnik GmbH
Type: ClimeEvent C/340/70/5/S
Year of Manufacture: 2019
Machine Type: Climate Testing Chamber / Temperature and Humidity Testing Chamber
Test Chamber Volume: approx. 340 liters
Description
For sale is a used Vötsch ClimeEvent C/340/70/5/S temperature and climate testing chamber from 2019.
This unit is a rare special edition with three side-pull-out telescopic test drawers. The test specimens can be conveniently prepared and connected outside the test chamber and then inserted into the test chamber. This makes the system particularly suitable for series testing, development tasks, long-term tests, and applications with frequent sample changes.
Each test drawer features a stainless steel grid basket and a separately lockable front with its own test specimen port. The three separate test levels allow for a clear arrangement of several test specimens or assemblies within a single test chamber.
The system is equipped, among other things, with WEBSeason Touch control, temperature and humidity control, Donaldson compressed air treatment, and extensive documentation.
The system is suitable for:
Temperature tests
Climate tests
Environmental simulation
Material testing
Electronics testing
Component testing
Battery testing
Sensor testing
Quality assurance
Research and development
Aging and stress tests
Technical Data
Manufacturer: Vötsch Industrietechnik GmbH
Type: ClimeEvent C/340/70/5/S
Year of Manufacture: 2019
Test Chamber Volume: approx. 340 liters
Temperature Range: approx. -70 °C to +180 °C
Temperature Change Rate: approx. 5 K/min
Max. Heat Compensation: approx. 3,000 W
Temperature Deviation (time-dependent): ±0.1 to ±0.5 K
Temperature Homogeneity (spatial): ±0.5 to ±1 K
Temperature Gradient: ≤2 K
Power Connection: 3/N/PE AC 400 V ±10% / 50 Hz
Rated Power: 9 kW
Rated Current: 20 A
Refrigerant 1: R449A – 2.50 kg
Refrigerant 2: R23 – 0.75 kg
Max. Low Pressure: 21 bar(g)
Max. High Pressure: 25 bar(g)
Stand Pressure R23: 13 bar(g)
Dimensions
External Dimensions (H x W x D):
approx. 1,800 x 895 x 1,810 mm
Test Chamber Dimensions (H x W x D):
approx. 750 x 580 x 765 mm
Weight: approx. 650 kg
Equipment
WEBSeason Touch Panel
Temperature and Humidity Control
Stainless Steel Interior
Large Observation Window
3 side-pull-out telescopic test drawers
3 stainless steel grid baskets
Separately lockable drawers
Heated drawer ports
Test specimen ports
Donaldson Ultrafilter for compressed air treatment
Shipping Information
External Dimensions (H x W x D):
approx. 1,800 x 895 x 1,810 mm
Weight: approx. 650 kg
Condition
Used
The unit has been workshop-tested and subjected to a documented test run.
The optical condition corresponds to the images.
Scope of Supply
Vötsch ClimeEvent C/340/70/5/S Climate Testing Chamber
3 telescopic test drawers
3 stainless steel grid baskets
Donaldson Ultrafilter
Accessories according to images
Shipping or forwarding possible.
Subject to change, errors and prior sale.
We are happy to answer any further questions by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Weiss climate test chamber ClimeEvent C/1000/70/5, -70°C to +180°C, 1000 liters, with humidity contr
WeissClimeEvent C/1000/70/5
Call
Condition: used, Weiss
Climate testing chamber ClimeEvent C/1000/70/5,
water-cooled, 1000 liters, year of manufacture 2019,
operating hours 3577.95 h.
For sale is a high-quality climate testing chamber of the type ClimeEvent C/1000/70/5.
The device is used in industry, development, and quality assurance to test components and products under extreme temperature and climatic conditions.
The chamber enables realistic simulations of environmental conditions – from extreme cold to high temperatures and humidity levels.
Hnedpjy Iyx Aofx Akrsu
Ideal for electronics, automotive, material testing, and research.
The device operates reliably and reproducibly and is designed for long-term tests and tests in accordance with standards.
With this climate chamber, temperature and humidity conditions can be specifically set and controlled.
This allows the aging, stress, and function of components to be tested under real environmental conditions.
Typical applications include temperature cycling tests, climate tests with humidity, and endurance tests.
Due to the rapid temperature change (up to approx. 5 K/min), accelerated tests are also possible.
Technical data:
Type: ClimeEvent C/1000/70/5
Year of manufacture: 2019
Temperature range: approx. -70 °C to +180 °C
Temperature change rate: up to approx. 5 K/min
Humidity range: approx. 10 % to 98 % RH
Internal dimensions (test chamber): approx. 950 x 1100 x 950 mm
Volume: approx. 1000 liters
External dimensions (approx.): 2000 x 1415 x 2030 mm
Power connection: 3/N/PE AC 400 V ±10% / 50 Hz
Rated power: approx. 21 kW
Rated current: approx. 34 A
Refrigerant: R449A / R23
Weight: approx. 1300 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See image)
(Changes and errors in the technical data and information are subject to change!)
We will gladly answer any further questions you may have by phone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Weiss WK3-340/70 Climate Test Chamber -70°C to +180°C, 335 liters, 10–98% relative humidity.
WeissWK3-340/70
Call
Condition: used, Weiss
Climate chamber / Temperature and humidity chamber
Weiss WK3-340/70 Climate chamber
Temperature range from -70 °C to +180 °C with humidity control
Approx. 335 liters / 10 to 98 % RH / air-cooled
For sale is a used climate chamber
from the manufacturer Weiss Umwelttechnik GmbH.
The climate chamber is suitable for temperature and humidity testing,
environmental simulation, material testing, quality assurance,
electronics and component testing
as well as development, aging and stress tests.
The unit features a programmable touch panel control,
temperature and humidity control, a large observation window
and lateral test specimen ports.
Technical data:
Manufacturer: Weiss Umwelttechnik GmbH
Type: WK3-340/70
Device type: Climate chamber / Temperature and humidity chamber
Test chamber volume: approx. 335 liters
Temperature range: -70 °C to +180 °C
Temperature change rate cooling: approx. 3 K/min
Temperature change rate heating: approx. 3 K/min
Temperature deviation over time: ±0.1 to ±0.5 K
Temperature homogeneity spatially: ±0.5 to ±1.5 K
Climate range temperature: +10 °C to +95 °C
Dew point range: -3 °C to +94 °C
Humidity range: 10 to 98 % RH
Temperature deviation over time in climate operation: ±0.1 to ±0.3 K
Temperature homogeneity spatially in climate operation: ±0.5 to ±1 K
Humidity deviation over time: ±1 to ±3 % RH
Refrigerant 1: R404A
Refrigerant quantity: 2.5 kg
Max. low pressure: 22.5 bar g
Max. high pressure: 25 bar g
Refrigerant 2: R23
Refrigerant quantity: 0.55 kg
Max. low pressure: 22.5 bar g
Max. high pressure: 25 bar g
Standby pressure: 13 bar g
Power connection: 3/N/PE AC 400 V ±10 % / 50 Hz
Rated power: 5.5 kW
Rated current: 16 A
Dimensions and weight:
Test chamber volume: approx. 335 liters
Internal dimensions (H × W × D): approx. 750 × 580 × 765 mm
External dimensions (H × W × D): approx. 1,775 × 870 × 1,600 mm
Weight: approx. 585 kg
Equipment:
Programmable touch panel control
Temperature control
Humidity control
Air-cooled design
Stainless steel interior
Large observation window
Test chamber lighting
Lateral test specimen ports
Adjustable feet
Program and manual operation
Test specimen port right: DN 125 mm
Hnedpfsz A A T Hex Akreu
Test specimen port left: DN 50 mm
Stainless steel inserts as shown in the pictures
Areas of application:
Temperature testing
Climate testing
Humidity testing
Environmental simulation
Material testing
Electronics testing
Component testing
Assembly testing
Quality assurance
Research and development
Lifetime testing
Aging and stress tests
Condition:
Used
Optical condition as shown in the pictures
Scope of delivery:
1x Weiss WK3-340/70 Climate chamber
Touch panel control
Stainless steel inserts as shown in the pictures
Accessories as shown in the pictures
Important note:
For the safety of our customers, the following work will be carried out on the offered test and climate systems in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. Documented test run after successful inspection
Shipping or freight forwarding possible.
Subject to change, errors and prior sale.
We will be happy to answer any further questions by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Weiss Temperature Chamber WT11-1000/70/5 Temperature range: -70°C to +180°C, 990 liters
WeissWT11-1000/70/5
Call
Condition: used, Weiss
Type: WT11-1000/70/5
Weiss temperature chamber, air-cooled, with Weiss condenser cooler
Test chamber volume approx. 990 liters
Data for temperature tests:
Temperature range -70°C to +180°C
Temporal temperature deviation in the center of the usable space ± 0.1 to ± 0.5 K
Spatial temperature deviation ± 0.5 to ± 2.0 K
Temperature gradient (according to IEC 60068-3-5) 1 to 4 K
Temperature change rate (according to IEC 60068-3-5)
Heating 5 K/min
Cooling 5 K/min
Heat compensation max. 2750 W
Feedthrough installed as standard
R1: NW 125 mm
L1: NW 50 m
Dimensions:
Test chamber dimensions: Width 1100 mm x Depth 950 mm x Height 950 mm
Housing dimensions: Width 1390 mm x Depth 1525 mm x Height 1995 mm
Maximum load (evenly distributed over the area) of the test chamber floor 150 kg
per insert grid 50 kg
Total load of the grid supports 100 kg
Data for operation:
Hodpfx Akezfy Rwjronu
Test chamber lighting: Halogen bulb 24V, 50W
Rated voltage 3/N / PE AC 400 V ± 10% 50 Hz
Rated power 27.0 kW
Rated current 42.02 A
Heat dissipation water-cooled test cabinets max. heat dissipation to the environment 1.3 kW
Noise measurement:
Sound pressure level approx. 64 dB(A)
Refrigerant: (converted to R-452a)
Weight: approx. 960 kg
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data and information are subject to change!)
We will gladly answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Weiss Temperature Test Chamber WT3-600/70/5, 600 liters, -70°C to +180°C
WeissWT3- 600/70/5
Call
Condition: used, Weiss
Type: WT3-600/70/5
Weiss temperature testing cabinet WT3-600/70/5
water-cooled version
with S!MCON / 32 control system and touch panel
Control panel "Touch Panel"
By simply touching the function symbols on the "Touch Panel" control panel, all control and operating commands can be activated.
Adjustable feet
To compensate for uneven floors and to ensure sufficient ventilation of the machine, the testing cabinet is equipped with adjustable feet.
Feedthroughs
The testing cabinet is equipped with feedthroughs on the right and left sides.
These allow measuring cables and testing equipment to be routed into the test chamber.
Feedthroughs installed as standard:
R1: DN 125 mm
L1: DN 50 mm
Test chamber volume: approx. 600 liters
External dimensions including hinges and door lock:
Height: 1995 mm, Width: 1090 mm, Depth: 1660 mm
External dimensions excluding hinges and door lock:
Height: 1995 mm, Width: 1000 mm, Depth: 1660 mm
Internal dimensions:
Height: 950 mm, Width: 800 mm, Depth: 800 mm
Data for temperature tests:
Hedpfey Nibpsx Akronu
Temperature range: -70 °C to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Temperature deviation spatially: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5):
Heating: 7.5 K/min
Cooling: 7.5 K/min
Maximum heat compensation: 2500 W
Data for operation:
Test chamber lighting: Halogen bulb 2 x 24V, 50W
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: approx. 23 A
Rated power: approx. 13 kW
On-site fuse protection: 16 A slow-blow
Sound pressure level:
Measured at a distance of 1 m in front / 1 m height: approx. 58 dB(A)
Refrigerant:
R-404A / R23
Weight: approx. 620 kg
For your safety as a buyer, here is the following information:
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
-72 to +180°C, 480 liters, with humidity control
Vötsch ClimeEventC/480/70/15 Klimaprüfschrank
Call
Year of construction: 2018, condition: excellent (used), Vötschtechnik ClimeEvent C/480/70/15 Climate Testing Chamber
Hsdpfx Aksz Airforsnu
Manufacturer: Vötsch Industrietechnik GmbH
Type: ClimeEvent C/480/70/15
Machine Type: Climate Testing Chamber / Temperature Testing Chamber
Test Chamber Volume: approx. 480 liters
Temperature Range: -72 °C to +180 °C
For sale is a used Vötschtechnik ClimeEvent C/480/70/15 climate testing chamber in a water-cooled version.
Suitable for temperature and climate testing, environmental simulation, material testing, quality assurance, as well as development, aging, and stress tests. Temperature and humidity profiles, as well as automatic test programs, can be executed via the touchscreen control.
Technical Data:
Test Chamber Volume: approx. 480 liters
Temperature Range: -72 °C to +180 °C
Heating Rate: approx. 17 K/min
Cooling Rate: approx. 15 K/min
Max. Heat Compensation at +20 °C: approx. 8,000 W
Climate Range: +10 °C to +95 °C
Humidity Range: 10 to 98 % RH
Dew Point Range: +4 °C to +94 °C
Refrigerant: R449A / R23
Refrigerant Quantity: 4.00 kg / 2.30 kg
Mains Connection: 3/N/PE AC 400 V ±10 % / 50 Hz
Rated Power: 24 kW
Rated Current: 43 A
Cooling:
Water-cooled version
Cooling water inlet and outlet
Connection for demineralized water
Overflow and condensate drain
Dimensions:
External dimensions according to the installation plan (W × D × H): approx. 2,807 × 1,000 × 2,020 mm
Transport dimensions with overhangs (L × W): approx. 2,857 × 1,115 mm
Equipment:
Touchscreen control / WEBPanel
Program and manual test operation
Temperature and humidity control
Stainless steel interior
Viewing window
Test chamber lighting
Shelves / Insert levels
Side test chamber openings
RS232, RS485 / RS422 and USB
Status, alarm and maintenance display
Program management and report function
Transport Data:
Transport dimensions: approx. 2,857 × 1,115 × 2,020 mm
Weight according to series documentation: approx. 1,350 kg
Shipping by freight forwarder possible
Condition:
Used
Workshop inspected
Optical condition as shown in the pictures.
Scope of Delivery:
Vötschtechnik ClimeEvent C/480/70/15
Shelves as shown in the pictures
Available documentation / Operating manual
Accessories as shown in the pictures
Availability: by arrangement.
Scope of delivery as shown in the pictures.
Subject to changes, errors and prior sale.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Weiss climate chamber WK11-600/70/5 with humidity control, approx. 600 liters, temperature range -70
WeissWK11-600/70/5
Call
Condition: used, Weiss
Type: WK11 - 600/70/5
Weiss Climate Chamber, Water-Cooled
The Weiss climate chamber WK11-600/70/5, with an approximate usable volume of 600 liters, is suitable for temperature and humidity testing as well as for conditioning samples and materials in the range of -70 °C to +180 °C.
Simcon/32 - Net Controller
Technical Data:
Test chamber designation: WK11-600/70/5
External dimensions with hinges and door closure:
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door closure:
Height 1995 mm, Width 1000 mm, Depth 800 mm
Internal dimensions:
Height 950 mm, Width 800 mm, Depth 800 mm
Connections:
2x R1 NW 125 mm ∅
1x L1 NW 50 mm ∅
Test chamber volume: approx. 600 liters
Data for temperature tests:
Temperature range -70 °C to 180 °C
Temporal temperature deviations in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviations: ± 0.5 to ± 2 K
Temperature gradient: 1 to 4 K
Temperature change rate:
Heating: 6 K/min
Cooling: 6 K/min
Thermal compensation:
at +20 °C: 5000 W
at -20 °C: 5000 W
Data for climate tests:
Temperature range +10 to +95 °C
Humidity range 10 to 98 % RH
Temporal temperature deviations in the center of the usable space: ± 0.1 to ± 0.3 K
Spatial temperature deviations: ± 0.5 to ± 1 K
Temperature gradient: 1 to 2 K
Temporal humidity fluctuation in the center of the usable space: ± 1 to ± 3 % RH
Thermal compensation: 500 W
3/N/PE AC 400V ±10% 50Hz
Rated power: 16.5 kW
Rated current: 29 A
Fuse on customer side: 32 A slow-blow
Permissible weight of test specimen:
Total load of the shelf supports: 80 kg
Test chamber floor: 80 kg, insert shelf: 40 kg
Weight: 675 kg
Refrigerant: R452A / R23
Important note:
"The table shown in the photos is not included in the sale."
For your safety as a buyer, please note the following information!
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
Hnedpfezimg Hjx Akrsu
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Weiss Climate Test Chamber WK3-340/70 with humidity control, temperature range -72°C to +180°C, appr
WeissKlimaprüfschrank
Call
Condition: used, Weiss
Type: WK3-340/70
Weiss Climate Testing Chamber, Air-Cooled
Control Panel »Touch Panel«
All control and operating commands can be initiated by simply touching the function symbols on the »Touch Panel« control panel.
Adjustable Feet
To compensate for uneven floors and ensure sufficient ventilation of the machine section, the testing chamber is equipped with adjustable feet.
Feedthroughs
The testing chamber is equipped with feedthroughs on the right and left sides.
These allow measuring cables and testing equipment to be routed into the test chamber.
Hnedpoziiwuofx Akrou
Feedthrough installed as standard
R1: 125 mm
L1: 85 mm
Volume: 335 liters
Test chamber dimensions:
Test chamber dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Data for temperature tests:
Minimum temperature -72°C
Maximum temperature +180°C
Temperature deviation, over time ± 0.1 to ± 0.5 K
Temperature homogeneity, spatially ± 0.5 to ± 1.5 K
Temperature change rate, cooling 3 K/min
Temperature change rate, heating 3 K/min
Data for climate tests:
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range 10 to 98% RH
Temperature deviation, over time ± 0.1 to ± 0.3 K
Temperature homogeneity, spatially ± 0.5 to ± 1 K
Humidity deviation, over time ± 1 to ± 3% RH
Data for operation:
Test chamber lighting: Halogen bulb 2 x 24V, 50W
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 16 A Rated power 4.9 kW
Fuse, to be provided by the customer: 16 A slow-blow
Refrigerant: R-452A/R23
Weight Approx. 585 kg
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are subject to change!)
We will be happy to answer any further questions you may have over the phone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Weiss WT-1000/70/5 Temperature Test Chamber 1000L -70/+180°C 6.1 K/min Heating 6 K/min Cooling
WeissWT-1000/70/5
Call
Condition: used, Weiss
Type: WT-1000/70/5
Hodpey D Nyuofx Akrenu
Weiss temperature testing chamber, water-cooled
With a temperature change rate of 5 K/min
Data for temperature tests:
Temperature range: -70 °C to +180 °C
Temporal temperature deviation in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature homogeneity: ± 0.5 to ± 2 K
Temperature change rate:
Heating: 6.1 K/min
Cooling: 6 K/min
Permissible test specimen weight:
Total load on the test chamber floor: 150 kg
Load per insert shelf: 50 kg
Dimensions:
Test chamber dimensions: Height 950 mm, Width 1100 mm, Depth 950 mm
External dimensions: Height 2000 mm, Width 1415 mm, Depth 2105 mm
Test chamber volume: 990 liters
Data for operation:
Nominal voltage: 3/N/PE AC 400 V ± 10% 50 Hz
Nominal current: 38 A Nominal power: 26 kW
Refrigerant: R404 / R23
Weight: approx. 955 kg
Information for buyers:
To ensure the safety of our customers, the following work will be carried out on the offered climate chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak test with certificate
4. Documented test run after successful inspection
Condition: used
Scope of supply: (See image)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Weiss Temperature Test Chamber TempEvent T/1000/70/5 -70°C to +180°C 1000 liters
WeissTempEvent T/1000/70/5
Call
Condition: used, Weiss
Temperature test chamber TempEvent T/1000/70/5,
water-cooled, 1000 liters, year of manufacture 2020,
operating hours 6126 h.
Description:
For sale is a high-quality climate test chamber from Vötsch Industrietechnik
(Weiss Technik), model TempEvent T/1000/70/5.
The device is used to simulate temperature conditions and is ideal for:
Material tests
Electronics tests
Hjdpoyxm Ulofx Akronu
Environmental and aging tests
Quality and endurance tests
The chamber can generate very low temperatures up to approx. -70 °C as well as high temperatures up to +180 °C
and change these at a defined rate (temperature ramps).
Precise control allows reproducible test conditions to be achieved.
Operation is conveniently carried out via an integrated touch panel.
Special features:
Fast temperature changes (up to 5 K/min)
Uniform temperature distribution in the test chamber
Water-cooled system
Industrial standard – robust design
Maintenance indicator and operating hour counter available
Technical data:
Model: TempEvent T/1000/70/5
Temperature range: approx. -70 °C to +180 °C
Temperature change: up to 5 K/min
High precision & stability:
Temporal temperature deviation: ±0.1 to ±0.5 K
→ very stable temperature over time
Spatial deviation: ±0.5 to ±1.0 K
Temperature gradient: ≤ 2.0 K
This makes the chamber ideal for demanding testing processes
with high repeatability
Test chamber: approx. 950 × 1100 × 950 mm (W × H × D)
External dimensions: approx. 2000 × 1415 × 2030 mm (W × H × D)
Side opening 50 cm / 125 cm
Electrical data:
400 V / 3~ / 50 Hz
Rated current: approx. 34 A
Power: approx. 21 kW
Refrigerant:
R449A (approx. 2.9 kg)
R23 (approx. 1.3 kg)
Weight: approx. 1200 kg
For your safety as a buyer, the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerants
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Weiss temperature chamber WT1-340/30, temperature range: -30°C to +180°C, 340 liters
WeissWT1-340/30
Call
Condition: used, Weiss
Type: WT1-340/30
Converted to R452a
Weiss temperature chamber, air-cooled
Temperature range: from -30°C to 180°C
Temperature change rate, cooling: 1.6 K/min
Temperature change rate, heating: 2.1 K/min
Test chamber dimensions: Width 550 mm x Depth 750 mm x Height 800 mm
Housing dimensions: Width 800 mm x Depth 1500 mm x Height 1800 mm
Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 4.9 kW, Rated current: 9 A
Refrigerant: R452a
Weight: 515 kg
For your safety as a buyer, please note the following information:
The following steps are performed on our offered chambers in advance:
1. Functional check and replacement of any necessary components
Hnsdpfszd Rw Sox Akrju
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Weiss temperature chamber WT3-340/40, 335 liters, temperature range -42°C to +180°C
WeissTemperaturprüfschrank
Call
Condition: used, Weiss
Type: WT3-340/40
Weiss Temperature Test Chamber with S!MCON / 32 Control System, Water-Cooled
(Refrigerant converted to R-452A)
Control Panel: "Touch Panel"
All control and operating commands can be initiated by simply touching the function symbols on the "Touch Panel" control panel.
Adjustable Feet
To compensate for uneven floors and to ensure sufficient ventilation of the machine part, the test chamber is equipped with adjustable feet.
Feedthroughs
The test chamber is equipped with feedthroughs on the right and left sides.
These allow measuring cables and testing equipment to be routed into the test chamber.
Feedthroughs installed as standard
R1: 125 mm diameter
L1: 50 mm diameter
Test chamber volume: approx. 335 liters
Test chamber dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Temporal temperature deviation in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate
Heating: 3.2 K/min
Cooling: 4.0 K/min
Maximum heat compensation: 2300 W
Data for operation:
Test chamber lighting: Halogen bulb 2x 24V, 50W
Rated voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Rated current: 14 A Rated power 4.1 kW
Fuse (to be provided by the customer): 16 A slow-blow
Sound pressure level approx.
measured at a distance of 1 m from the front, 1 m height: 56 dB(A)
Refrigerant: R-452A
Weight: 515 kg
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
Hjdpfx Aezgbkhjkronu
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Weiss Technik temperature test chamber TempEvent T/1000/70e/5 -70°C to +180°C 1000 litres
WeissTempEvent T/1000/70e/5
Call
Condition: used, Weiss
Temperature testing chamber TempEvent T/1000/70e/5,
water-cooled, 1000 liters, year of manufacture 2021,
operating hours 4979.69 h
For sale is a used temperature testing chamber from Weiss Technik.
The testing chamber is used to test components and materials under various
temperature conditions (e.g., cold, heat, aging).
Explanation of the designation:
T = Temperature testing chamber
1000 = approx. 1000 liters volume
70 = Low-temperature range (-70 °C)
e = energy-optimized version
5 = Temperature change rate (series)
Equipment:
Stainless steel interior
Circulation fans
Touch operation (WEBSeason)
Hsdpoy El Ttjfx Akrenu
Viewing window
Temperature control automatic / manual
Technical data:
Model: TempEvent T/1000/70e/5
Internal volume: approx. 1000 liters
Temperature range: approx. -70 °C to +180 °C
Temperature change:
Cooling approx. 6 K/min
Heating approx. 8 K/min
External dimensions: approx. 2000 x 1415 x 2030 mm (H x W x D)
Internal dimensions: approx. 950 x 1100 x 950 mm (H x W x D)
Connection: 3/N/PE AC 400V =10% 50Hz
Rated current: approx. 34 A Power: approx. 21 kW
Refrigerant: R449A / R23
Weight: approx. 1200 kg
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and information are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Weiss climate test chamber WK1-1000/70, temperature range from -70°C to +180°C with humidity control
WeissKlimaprüfschrank WK1-1000/70
Call
Condition: used, Weiss
Type: WK1-1000/70
Weiss Climate Test Chamber, Water-Cooled
(Refrigerant converted to R-452A)
Control Panel “Touch Panel”
All control and operating commands can be initiated on the “Touch Panel” control panel by simply touching the function symbols.
Feedthroughs
The test chamber is equipped with feedthroughs on the right and left sides.
These allow measurement cables and testing equipment to be placed in the test chamber.
Feedthroughs:
1 feedthrough, ∅ 125 mm, installed on the right
1 feedthrough, ∅ 50 mm, installed on the left
Volume: 990 liters
Test chamber dimensions:
Test chamber: Width 1100 mm, Depth 950 mm, Height 950 mm
Housing: Width 1385 mm, Depth 1850 mm, Height 1980 mm
Data for temperature tests:
Minimum temperature: -70 °C
Maximum temperature: +180 °C
Temperature deviation, temporal: ± 0.1 to ± 0.5 K
Temperature homogeneity, spatial: ± 0.5 to ± 2 K
Temperature change rate, heating: 4 K/min
Temperature change rate, cooling: 2.5 K/min
Max. heat compensation: 2750 W
Data for climate tests:
Temperature range: +10°C to +95°C
Humidity range: 10 to 98% RH
Temperature deviation, temporal: ± 0.1 to ± 0.3 K
Temperature homogeneity, spatial: ± 0.5 to ± 1 K
Humidity deviation, temporal: ± 1 to ± 3% RH
Data for operation:
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 29A, Nominal power: 19.8 kW
Refrigerant: R-452A / R23
Hsdpfxozgbtpj Akrjnu
Weight: approx. 910 kg
For your safety as a buyer, here is the following information:
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and information are subject to change!)
We would be happy to answer any further questions you may have by phone.
Success:
Your message has been sent.
Listing
Bastogne
7,092 km
2002 WEISS CR25-225
WEISSCR25-225
Call
Condition: used, Year of construction: 2002, Power 18.5kw
Rotor 600mm
Opening 100cm/100cm
Hjdpfx Aez Ihw Uokrsnu
Hours : 2677
380V
Success:
Your message has been sent.
Listing
Borken
7,009 km
Weiss WT-1300/70/15 Temperature Test Chamber 1300 liters -70°C to +180°C 15 K/min
WeissWT-1300/70/15
Call
Condition: used, Weiss
Type: WT-1300/70/15
Weiss temperature testing chamber, water-cooled
with touch panel control
Data for temperature tests:
Temperature range: -70 °C to +180 °C
Test chamber volume: approx. 1340 liters
Temperature change rate:
Heating: 15 K/min
Cooling: 10 K/min
Temperature deviation over time in the center of the usable space:
± 0.1 to ± 0.5 K
Temperature homogeneity spatially:
± 0.5 to ± 2 K
Test chamber dimensions:
Height: 920 mm, Width: 1100 mm, Depth: 1330 mm
External dimensions:
Height: approx. 2050 mm, Width: approx. 1300 mm, Depth: approx. 3200 mm
Permissible test item weight:
Total load on the test chamber floor: 150 kg
Load per insert shelf: 50 kg
Data according to the nameplate:
Manufacturer: Weiss Umwelttechnik GmbH
Type: WT-1300/70/15
Data for operation:
Rated voltage: 3/N/PE AC 400 V ±10% 50 Hz
Rated current: 63 A
Rated power: 44 kW
Refrigerant:
R404A: 14.0 kg
R23: 5.4 kg
Maximum permissible pressures:
R404A LP max.: 18 bar
R404A HP max.: 25 bar
R23 LP max.: 19 bar
R23 HP max.: 25 bar
Standby pressure: 18.5 bar
Equipment:
Touch panel control
Stainless steel test chamber
Multiple insertion levels
Side access
Heated door seal
Water-cooled refrigeration unit
CEE connector
CE marking available
Weight: approx. 1500 kg
For the safety of our customers, the following work will be carried out on the offered climate chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. Documented test run after successful inspection
Hnedpfx Akoza Dv Iorou
Condition: used
Scope of delivery: (See image)
Shipping or freight forwarding possible.
Subject to changes, errors and prior sale.
We will gladly answer any further questions by telephone.
Trust Seal
Dealers certified through Machineseeker

Success:
Your message has been sent.
Listing
Borken
7,009 km
Weiss Technik temperature test chamber TempEvent T/1000/70e/5 -70°C to +180°C 1000 litres
WeissTempEvent T/1000/70e/5
Call
Condition: used, Weiss
Temperature test chamber TempEvent T/1000/70e/5,
water-cooled, 1000 liters, year of manufacture 2021,
operating hours 5128 h
For sale is a used temperature test chamber from Weiss Technik.
The test chamber is used to test components and materials under various
temperature conditions (e.g., cold, heat, aging).
Explanation of the designation:
T = Temperature test chamber
1000 = approx. 1000 liters volume
70 = Low-temperature range (-70 °C)
e = energy-optimized design
5 = Temperature change rate (series)
Hsdpfxjy Dck Te Akronu
Equipment:
Stainless steel interior
Circulation fans
Touch operation (WEBSeason)
Viewing window
Temperature control, automatic / manual
Technical data:
Model: TempEvent T/1000/70e/5
Internal volume: approx. 1000 liters
Temperature range: approx. -70 °C to +180 °C
Temperature change:
Cooling approx. 6 K/min
Heating approx. 8 K/min
External dimensions: approx. 2000 x 1415 x 2030 mm (H x W x D)
Internal dimensions: approx. 950 x 1100 x 950 mm (H x W x D)
Connection: 400 V / 50 Hz / 3~
Rated current: approx. 34 A
Power: approx. 21 kW
Refrigerant: R449A / R23
Weight: approx. 1200 kg
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Weiss Technik temperature test chamber TempEvent T/1000/70e/5 -70°C to +180°C 1000 litres
WeissTempEvent T/1000/70e/5
Call
Condition: used, Weiss
Temperature testing chamber TempEvent T/1000/70e/5,
water-cooled, 1000 liters, year of manufacture 2021
Operating hours: 5018 h
For sale is a used temperature testing chamber from Weiss Technik.
The testing chamber is used to test components and materials under various
temperature conditions (e.g., cold, heat, aging).
Meaning of the designation:
T = Temperature testing chamber
1000 = approx. 1000 liters volume
70 = Low-temperature range (-70 °C)
e = energy-optimized version
5 = Temperature change rate (model series)
Equipment:
Stainless steel interior
Circulation fans
Touch operation (WEBSeason)
Viewing window
Temperature control, automatic / manual
Technical data:
Model: TempEvent T/1000/70e/5
Internal volume: approx. 1000 liters
Temperature range: approx. -70 °C to +180 °C
Temperature change:
Cooling approx. 6 K/min
Heating approx. 8 K/min
External dimensions: approx. 2000 x 1415 x 2030 mm (H x W x D)
Internal dimensions: approx. 950 x 1100 x 950 mm (H x W x D)
Connection: 400 V / 50 Hz / 3~
Rated current: approx. 34 A
Power: approx. 21 kW
Refrigerant: R449A / R23
Weight: approx. 1300 kg
Hnsdpfx Aey Dclqekrou
For your security as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Weiss Technik temperature test chamber TempEvent T/1000/70e/5 -70°C to +180°C 1000 litres
WeissTempEvent T/1000/70e/5
Call
Condition: used, Weiss
Temperature testing chamber TempEvent T/1000/70e/5,
water-cooled, 1000 liters, year of manufacture 2021,
operating hours 4748.2 h
For sale is a used temperature testing chamber from Weiss Technik.
The testing chamber is used to test components and materials under various
temperature conditions (e.g., cold, heat, aging).
Meaning of the designation:
T = Temperature testing chamber
1000 = approx. 1000 liters volume
70 = Low-temperature range (-70 °C)
e = energy-optimized design
5 = Temperature change rate (model series)
Hnodpfey Dd Nqex Akrou
Equipment:
Stainless steel interior
Circulation fans
Touch operation (WEBSeason)
Viewing window
Temperature control, automatic / manual
Technical data:
Model: TempEvent T/1000/70e/5
Internal volume: approx. 1000 liters
Temperature range: approx. -70 °C to +180 °C
Temperature change:
Cooling approx. 6 K/min
Heating approx. 8 K/min
External dimensions: approx. 2000 x 1415 x 2030 mm (H x W x D)
Internal dimensions: approx. 950 x 1100 x 950 mm (H x W x D)
Connection: 400 V / 50 Hz / 3~
Rated current: approx. 34 A
Power: approx. 21 kW
Refrigerant: R449A / R23
Weight: approx. 1200 kg
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Weiss Technik temperature test chamber TempEvent T/1000/70e/5 -70°C to +180°C 1000 litres
WeissTempEvent T/1000/70e/5
Call
Condition: used, Weiss
Temperature test chamber TempEvent T/1000/70e/5,
water-cooled, 1000 liters, year of manufacture 2021,
operating hours 4748 h
For sale is a used temperature test chamber from Weiss Technik.
The test chamber is used to test components and materials under various
temperature conditions (e.g., cold, heat, aging).
Explanation of the designation:
T = Temperature test chamber
1000 = approx. 1000 liters volume
70 = Low-temperature range (-70 °C)
e = energy-optimized design
5 = Temperature change rate (series)
Equipment:
Stainless steel interior
Circulation fans
Touch control (WEBSeason)
Viewing window
Hnodsy Dciijpfx Akrsu
Temperature control, automatic / manual
Technical data:
Model: TempEvent T/1000/70e/5
Internal volume: approx. 1000 liters
Temperature range: approx. -70 °C to +180 °C
Temperature change:
Cooling approx. 6 K/min
Heating approx. 8 K/min
External dimensions: approx. 2000 x 1415 x 2030 mm (HxWxD)
Internal dimensions: approx. 950 x 1100 x 950 mm (HxWxD)
Connection: 400 V / 50 Hz / 3~
Rated current: approx. 34 A
Power: approx. 21 kW
Refrigerant: R449A / R23
Weight: approx. 1200 kg
For your security as a buyer, the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data, information subject to change!)
We will be happy to answer any further questions you may have on the telephone.
We make it easier for you to find: "weiss climeevent c/340/70/5"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month













































































































































































































