BAC S15E 1018-10 LE open evaporative cooling tower chiller dry cooler refrigeration unitBAC
S15E 1018-10 LE
BAC S15E 1018-10 LE open evaporative cooling tower chiller dry cooler refrigeration unit
BAC
S15E 1018-10 LE
ONO plus VAT
€26,800
Condition
Used
Location
Borken 

Basic data
- Machine type:
- BAC S15E 1018-10 LE open evaporative cooling tower chiller dry cooler refrigeration unit
- Manufacturer:
- BAC
- Model:
- S15E 1018-10 LE
- Condition:
- used
Price & Location
ONO plus VAT
€26,800
- Location:
- 46325 Borken, Deutschland

Call
Details about the offer
- Listing ID:
- A21340202
- Reference number:
- 60821
- Update:
- 21.10.2026
Description
BAC S1500E Cooling Tower
The BAC S15E 1018-10-LE is a high-performance, open-circuit cooling tower from the S1500E series manufactured by Baltimore Aircoil Company (BAC).
This specific model is designed for industrial cooling applications and large HVAC systems where high efficiency and ease of maintenance are priorities.
Technology
Patented BACross III fill media system, which allows for easy inspection of the fill to prevent biological growth (e.g., Legionella).
Key Features of the S1500E Series
Maintenance access: A large, inward-swinging access door and internal maintenance platforms allow technicians to conveniently perform inspections while standing inside the unit.
Hygiene control: The design minimizes standing water and protects against sunlight through special air inlet elements, reducing algae growth.
Flexibility: The single-sided air intake allows the cooling tower to be installed even in confined spaces or directly against walls.
Materials: Galvanized steel with Baltibond hybrid coating.
Typical Applications
Industrial cooling: Used in factories for process cooling.
HVAC: Used in large building complexes as part of a central chiller system.
Refrigeration: Used as a condenser in commercial refrigeration systems.
Cooling Capacity
An open evaporative cooling tower does not have a fixed, single kW cooling capacity, as the actual performance depends entirely on the thermodynamic ambient conditions and system temperatures.
The model is designed for maximum flow rates of up to 198 liters per second.
Under typical industrial or HVAC standard conditions, the nominal cooling capacity of this model is in the range of approximately 1,200 kW to 2,100 kW.
Lsdpfx Aoynkbmekmsru
Why does the cooling capacity vary?
Wet-bulb temperature (outside air): The cooler and drier the ambient air, the more water can evaporate, and the higher the cooling capacity.
Water temperatures: The performance changes significantly depending on the warm water inlet temperature (e.g., 35 °C) and the cold water outlet temperature (e.g., 29 °C).
Air volume flow: According to BAC's technical data, the S15E 1018-10 LE model actively moves 60.0 m³/s of air through three installed 11.0 kW fan motors.
If this air volume is reduced by a frequency inverter (e.g., during night operation or in winter), the cooling capacity decreases in a controlled manner.
Approach: This is the most important thermodynamic limit. It describes the difference between the desired cold water temperature and the physically determined wet-bulb temperature. The closer the cold water is cooled to the wet-bulb temperature (smaller approach), the less kW of power the tower can provide.
Technical Data:
Fan and Air Data
- Air volume flow: 60.0 m³/s (generated in suction operation)
- Fan motors: 3x 11.0 kW (axial fans)
- Technology: Integrated belt drive
- Water flow: 198 l/s
Hydraulic Connections
- Water inlet: 1x DN 250 (nominal size ND 250 mm)
- Water outlet: 1x DN 300 (nominal size ND 300 mm)
- Make-up water connection: 1x DN 40 (ND 40 mm)
- Overflow / Drain: DN 80 (ND 80 mm) / DN 50 (ND 50 mm)
Dimensions and Weights
- Operating weight: 11,446 kg (including water fill up to overflow)
- Shipping weight: 5,350 kg (empty weight)
- Heaviest single part: 3,114 kg (for installation)
The listing was translated automatically. Translation errors are possible.
The BAC S15E 1018-10-LE is a high-performance, open-circuit cooling tower from the S1500E series manufactured by Baltimore Aircoil Company (BAC).
This specific model is designed for industrial cooling applications and large HVAC systems where high efficiency and ease of maintenance are priorities.
Technology
Patented BACross III fill media system, which allows for easy inspection of the fill to prevent biological growth (e.g., Legionella).
Key Features of the S1500E Series
Maintenance access: A large, inward-swinging access door and internal maintenance platforms allow technicians to conveniently perform inspections while standing inside the unit.
Hygiene control: The design minimizes standing water and protects against sunlight through special air inlet elements, reducing algae growth.
Flexibility: The single-sided air intake allows the cooling tower to be installed even in confined spaces or directly against walls.
Materials: Galvanized steel with Baltibond hybrid coating.
Typical Applications
Industrial cooling: Used in factories for process cooling.
HVAC: Used in large building complexes as part of a central chiller system.
Refrigeration: Used as a condenser in commercial refrigeration systems.
Cooling Capacity
An open evaporative cooling tower does not have a fixed, single kW cooling capacity, as the actual performance depends entirely on the thermodynamic ambient conditions and system temperatures.
The model is designed for maximum flow rates of up to 198 liters per second.
Under typical industrial or HVAC standard conditions, the nominal cooling capacity of this model is in the range of approximately 1,200 kW to 2,100 kW.
Lsdpfx Aoynkbmekmsru
Why does the cooling capacity vary?
Wet-bulb temperature (outside air): The cooler and drier the ambient air, the more water can evaporate, and the higher the cooling capacity.
Water temperatures: The performance changes significantly depending on the warm water inlet temperature (e.g., 35 °C) and the cold water outlet temperature (e.g., 29 °C).
Air volume flow: According to BAC's technical data, the S15E 1018-10 LE model actively moves 60.0 m³/s of air through three installed 11.0 kW fan motors.
If this air volume is reduced by a frequency inverter (e.g., during night operation or in winter), the cooling capacity decreases in a controlled manner.
Approach: This is the most important thermodynamic limit. It describes the difference between the desired cold water temperature and the physically determined wet-bulb temperature. The closer the cold water is cooled to the wet-bulb temperature (smaller approach), the less kW of power the tower can provide.
Technical Data:
Fan and Air Data
- Air volume flow: 60.0 m³/s (generated in suction operation)
- Fan motors: 3x 11.0 kW (axial fans)
- Technology: Integrated belt drive
- Water flow: 198 l/s
Hydraulic Connections
- Water inlet: 1x DN 250 (nominal size ND 250 mm)
- Water outlet: 1x DN 300 (nominal size ND 300 mm)
- Make-up water connection: 1x DN 40 (ND 40 mm)
- Overflow / Drain: DN 80 (ND 80 mm) / DN 50 (ND 50 mm)
Dimensions and Weights
- Operating weight: 11,446 kg (including water fill up to overflow)
- Shipping weight: 5,350 kg (empty weight)
- Heaviest single part: 3,114 kg (for installation)
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Last online: A week ago
Registered since: 2008
534 listings online
Send inquiry
Telephone & Fax
+49 2862 ... show
These listings may also fit your interest.
Success:
Your message has been sent.
Listing
Łęczna
5,908 km
Chiller / Heat pump
New Chiller / Heat pumpBlue Box 16/18 kW | With warranty
New Chiller / Heat pumpBlue Box 16/18 kW | With warranty
Success:
Your message has been sent.
Listing
Dinkelscherben
6,736 km
Conveyor belt ascending conveyor belt conveyor system
die magnetprofis2021100803
die magnetprofis2021100803
Success:
Your message has been sent.
Listing
Remseck am Neckar
6,836 km
Industrial refrigeration compound system with Bitzer
Bitzer Verbundanlage6J-22.2Y-40P/ 4H-15.2Y-40P
Bitzer Verbundanlage6J-22.2Y-40P/ 4H-15.2Y-40P
Success:
Your message has been sent.
Listing
Niedźwiedź
6,062 km
Cooler
GüntnerS-GGN 066C/27
GüntnerS-GGN 066C/27
Success:
Your message has been sent.
Listing
Hillegom
7,168 km
Waterchiller
YorkYLCS1110HA 50Y A
YorkYLCS1110HA 50Y A
Success:
Your message has been sent.
Listing
Niedźwiedź
6,062 km
Compressor DWM Copeland D6DH3-3500-AWM/D
DWM CopelandD6DH3-3500-AWM/D
DWM CopelandD6DH3-3500-AWM/D
Success:
Your message has been sent.
Listing
Romania
6,946 km
Engel DUO 3550/400 pico
EngelDUO 3550/400 pico
EngelDUO 3550/400 pico
Success:
Your message has been sent.
Listing
Hillegom
7,168 km
Dry cooler
CaberoGCHSD089MB/X7S-40 Y V
CaberoGCHSD089MB/X7S-40 Y V
Success:
Your message has been sent.
Listing
Niedźwiedź
6,062 km
Condenser
GüntnerGVH 090.2A/2x5-N(D)
GüntnerGVH 090.2A/2x5-N(D)
Success:
Your message has been sent.
Listing
Hillegom
7,168 km
Cooling tower
EvapcoATW 36-4M
EvapcoATW 36-4M
Your listing has been deleted successfully
An error has occurred