Interior simulation boxIPETRONIK
IPETRONIK Innenraumsimulationsbox
Interior simulation box
IPETRONIK
IPETRONIK Innenraumsimulationsbox
Fixed price plus VAT
€18,500
Condition
New
Location
Borken 

Machine data
Price & Location
Fixed price plus VAT
€18,500
- Location:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Call
Details about the offer
- Listing ID:
- A22150412
- Reference number:
- 23509
- Update:
- 18.06.2026
Description
IPETRONIK Interior Simulation Box
Here we offer an IPETRONIK interior simulation box.
Technical data and description of the system:
IPETRONIK Interior Simulation Box (new and unused)
The interior simulation box is designed to simulate the passenger compartment for tests in recirculation mode.
It has a variable interior volume of 1.8 to 4 m³.
The exhaust air volume flow from the front evaporator or the air conditioning unit is regulated and directed into the interior.
Only rear evaporators installed in the passenger compartment are tested with the interior simulation box.
The insulated housing is mounted on an aluminum profile frame with rollers.
A light is installed in the chamber.
The box is protected against overheating via a safety thermostat (ESTI).
If the permissible temperature is exceeded, a glass cartridge in the ESTI is destroyed. The system is stopped.
(TRIGGER TEMPERATURE: 80°C)
Technical data of the insulated chamber:
Dimensions:
External: Width 1,860 mm, Depth 2,360 mm, Height 1,360 mm
Internal: Width 1,700 mm, Depth 2,200 mm, Height 1,200 mm
Insulation:
80 mm rigid polyurethane foam, CFC-free, U-value 0.27 W/m2K, building material class B1 according to DIN 4102
Technical data and description of the system:
Iisdpfezd Ukpox Anvsc
Connection: Tongue-and-groove system with foam-injected eccentric locking latches.
Surfaces:
Both sides: 0.8 mm stainless steel sheet 1.4301, polished, grit 320
Floor design:
2.0 mm stainless steel sheet 1.4301, SM rhombus pattern, non-slip,
Floor with a 90° upturned edge around the perimeter (approx. 15 mm), floor sheet flush with wall sheet,
Pressure distribution plate made of laminated wood, can withstand a load of 1,500 N / rubber wheel (contact area > 4 cm2),
30,000 N/m2 surface load, floor joints completely welded, welded stainless steel pipe as a floor drain,
led downwards through the floor
Chamber door:
Hatch door, 1-leaf, 800 x 1200 mm i.L., DIN left, heated door frame (230 V),
Heating tapes are silicone-free, 4-sided sealing profile made of EPDM,
Latch closure, lockable, emergency release,
Heated viewing window, 500 x 500 mm, triple-glazed,
Surface heating (230 V), frame heating (230 V), heating controlled by the customer,
Silicone-free edge trim
Sliding wall:
1680 x 1180 mm, 80 mm rigid polyurethane foam, 0.8 mm stainless steel sheet 1.4301 on both sides,
polished, grit 320, with protective film, closed on the other side with sheet metal
(The rear wall is manually adjustable in stepless increments to change the volume)
Recirculation system:
A heat exchanger (Systemair) for indirect temperature control is installed in the recirculation circuit for temperature control.
The air is circulated by a radial duct fan (Cosmo), and heating is provided by an electric heater (Türk and Hillinger) integrated into the brine circuit.
The heaters are continuously monitored by means of temperature monitors and limiters (Türk and Hillinger, Johnsson Controls).
Cooling is carried out via a secondary brine circuit with pumps (KSB) and a 3-way valve (Belimo).
Installed electrical heating power 1 * 6kW.
The mixing ratio is 50% water / 50% ethylene glycol.
Power supply from station: =TME2++AS-QF21
Operating voltage: 400V
Power: 17kW
Rated current: 33A
Fuse: 35A
Control voltage: 24V DC / 24V AC / 230V AC
PLC system: S7 300
Type: IPETRONIK Interior Simulation Box
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data, information are subject to change!)
We will be happy to answer any further questions
The listing was translated automatically. Translation errors are possible.
Here we offer an IPETRONIK interior simulation box.
Technical data and description of the system:
IPETRONIK Interior Simulation Box (new and unused)
The interior simulation box is designed to simulate the passenger compartment for tests in recirculation mode.
It has a variable interior volume of 1.8 to 4 m³.
The exhaust air volume flow from the front evaporator or the air conditioning unit is regulated and directed into the interior.
Only rear evaporators installed in the passenger compartment are tested with the interior simulation box.
The insulated housing is mounted on an aluminum profile frame with rollers.
A light is installed in the chamber.
The box is protected against overheating via a safety thermostat (ESTI).
If the permissible temperature is exceeded, a glass cartridge in the ESTI is destroyed. The system is stopped.
(TRIGGER TEMPERATURE: 80°C)
Technical data of the insulated chamber:
Dimensions:
External: Width 1,860 mm, Depth 2,360 mm, Height 1,360 mm
Internal: Width 1,700 mm, Depth 2,200 mm, Height 1,200 mm
Insulation:
80 mm rigid polyurethane foam, CFC-free, U-value 0.27 W/m2K, building material class B1 according to DIN 4102
Technical data and description of the system:
Iisdpfezd Ukpox Anvsc
Connection: Tongue-and-groove system with foam-injected eccentric locking latches.
Surfaces:
Both sides: 0.8 mm stainless steel sheet 1.4301, polished, grit 320
Floor design:
2.0 mm stainless steel sheet 1.4301, SM rhombus pattern, non-slip,
Floor with a 90° upturned edge around the perimeter (approx. 15 mm), floor sheet flush with wall sheet,
Pressure distribution plate made of laminated wood, can withstand a load of 1,500 N / rubber wheel (contact area > 4 cm2),
30,000 N/m2 surface load, floor joints completely welded, welded stainless steel pipe as a floor drain,
led downwards through the floor
Chamber door:
Hatch door, 1-leaf, 800 x 1200 mm i.L., DIN left, heated door frame (230 V),
Heating tapes are silicone-free, 4-sided sealing profile made of EPDM,
Latch closure, lockable, emergency release,
Heated viewing window, 500 x 500 mm, triple-glazed,
Surface heating (230 V), frame heating (230 V), heating controlled by the customer,
Silicone-free edge trim
Sliding wall:
1680 x 1180 mm, 80 mm rigid polyurethane foam, 0.8 mm stainless steel sheet 1.4301 on both sides,
polished, grit 320, with protective film, closed on the other side with sheet metal
(The rear wall is manually adjustable in stepless increments to change the volume)
Recirculation system:
A heat exchanger (Systemair) for indirect temperature control is installed in the recirculation circuit for temperature control.
The air is circulated by a radial duct fan (Cosmo), and heating is provided by an electric heater (Türk and Hillinger) integrated into the brine circuit.
The heaters are continuously monitored by means of temperature monitors and limiters (Türk and Hillinger, Johnsson Controls).
Cooling is carried out via a secondary brine circuit with pumps (KSB) and a 3-way valve (Belimo).
Installed electrical heating power 1 * 6kW.
The mixing ratio is 50% water / 50% ethylene glycol.
Power supply from station: =TME2++AS-QF21
Operating voltage: 400V
Power: 17kW
Rated current: 33A
Fuse: 35A
Control voltage: 24V DC / 24V AC / 230V AC
PLC system: S7 300
Type: IPETRONIK Interior Simulation Box
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data, information are subject to change!)
We will be happy to answer any further questions
The listing was translated automatically. Translation errors are possible.
Send inquiry
Telephone & Fax
+49 2861 ... show
Your listing has been deleted successfully
An error has occurred









