2004 kW Jenbacher JMS 612 GS-N.L Cogeneration PlantJENBACHER
JMS 612 GS-N.L.
2004 kW Jenbacher JMS 612 GS-N.L Cogeneration Plant
JENBACHER
JMS 612 GS-N.L.
Condition
Used
Location
Portugal 

Show images
Show map
Machine data
- Machine type:
- 2004 kW Jenbacher JMS 612 GS-N.L Cogeneration Plant
- Manufacturer:
- JENBACHER
- Model:
- JMS 612 GS-N.L.
- Condition:
- used
Price & Location
- Location:
- Portugal

Call
Details about the offer
- Listing ID:
- A19886270
- Reference number:
- RG1040
- Update:
- 24.09.2025
Description
Used Jenbacher JMS 612 GS-N.L Gas-Powered CHP Plant
Manufactured in 2011, this combined heat and power (CHP) plant is currently configured for tri-generation — producing cooling, heating, and power within a single integrated process. Cooling is achieved via absorption chillers.
Technical Specifications:
Electrical output: 2,004 kWel
Thermal output: 4,551 kWt
Fuel consumption: 479 Nm³/h of natural gas
Dedpfx Ajw T Rg Tsddjwf
Gas flow rate: 2.79 kg/s
Exhaust gas temperature: 410 °C
Engine speed: 1,500 rpm
Inlet air temperature: Ambient +10 °C
Frequency: 50 Hz
Voltage: 6,300 V
Included Equipment:
Heat Recovery Boiler — Water tube design; gas flow 2.79 kg/s; inlet temperature 410 °C; outlet temperature 120 °C; water outlet 101 °C; water inlet 90 °C; recovery capacity 953 kWt.
Absorption Chiller — Refrigeration capacity 1,000 kWt; hot water flow 78.5 m³/h.
Plate Heat Exchanger — Constructed from 316 stainless steel; designed for producing hot process water using hot water recovered from the boiler.
Air Cooler — Ensures stable engine operation and optimized thermal efficiency.
Cooling Tower — Supports effective heat dissipation for continuous tri-generation performance.
More technical details, drawings, and operational data are available upon request.
Manufactured in 2011, this combined heat and power (CHP) plant is currently configured for tri-generation — producing cooling, heating, and power within a single integrated process. Cooling is achieved via absorption chillers.
Technical Specifications:
Electrical output: 2,004 kWel
Thermal output: 4,551 kWt
Fuel consumption: 479 Nm³/h of natural gas
Dedpfx Ajw T Rg Tsddjwf
Gas flow rate: 2.79 kg/s
Exhaust gas temperature: 410 °C
Engine speed: 1,500 rpm
Inlet air temperature: Ambient +10 °C
Frequency: 50 Hz
Voltage: 6,300 V
Included Equipment:
Heat Recovery Boiler — Water tube design; gas flow 2.79 kg/s; inlet temperature 410 °C; outlet temperature 120 °C; water outlet 101 °C; water inlet 90 °C; recovery capacity 953 kWt.
Absorption Chiller — Refrigeration capacity 1,000 kWt; hot water flow 78.5 m³/h.
Plate Heat Exchanger — Constructed from 316 stainless steel; designed for producing hot process water using hot water recovered from the boiler.
Air Cooler — Ensures stable engine operation and optimized thermal efficiency.
Cooling Tower — Supports effective heat dissipation for continuous tri-generation performance.
More technical details, drawings, and operational data are available upon request.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2020
Send inquiry
Telephone & Fax
+44 1325 ... show
These listings may also fit your interest.
Listing
Balaguer
7,548 km
Welding equipment
FRONIUSMagicWave 3000
FRONIUSMagicWave 3000
Listing
Sonsbeck
7,046 km
Combined heat and power plant
G2MWM
G2MWM
Listing
Poland
6,172 km
ABB HIGH VOLTAGE INDUCTION MOTORS
ABBAMI 400L2L 630 KW
ABBAMI 400L2L 630 KW
Listing
Berlin
6,574 km
Combined Heat and Power Plant
HERFORD/ MARELLI
HERFORD/ MARELLI
Listing
Bruckmühl
6,636 km
Combined heat and power plant
JenbacherJGC 312 GS-N.LC
JenbacherJGC 312 GS-N.LC
Listing
Germany
8,869 km
Welding Unit
KEMPPIPS 3500
KEMPPIPS 3500
Listing
Sheffield
7,565 km
CNC Turning Centre - Horizontal
Takisawa TaiwanEX308
Takisawa TaiwanEX308
Listing
Maasmechelen
7,091 km
Glass grinding machine
LattuadaTLR 13 C
LattuadaTLR 13 C
Listing
Hopsten
6,962 km
Combined heat and power plant
Spanner Re2HKA49
Spanner Re2HKA49
Listing
Chrzanowo
6,050 km
Fogo FDT 820 S generator set
FogoFDT 820 S
FogoFDT 820 S
Your listing has been deleted successfully
An error has occurred







































































































