Machine data
- Machine type:
- Negative monoblock overhanging refrigeration unit
- Manufacturer:
- L19130B
- Model:
- JKS
- Condition:
- new
Price & Location
Fixed price plus VAT
€4,844
- Location:
- Rue de Fontenay 110, 94300 Vincennes, France

Call
Details about the offer
- Listing ID:
- A20495340
- Update:
- 10.11.2025
Description
- External dimensions (LxWxH): 644x930x863 mm
- Application range: -18 ÷ -22°C
- Evaporation temperature: -30°C
- Condensation temperature: +40°C
- Cold room temperature: -20°C
- Ambient temperature: 32°C
- Defrost: Hot gas
- Power supply: 230 V / 1+N ph / 50 Hz
- Maximum absorbed current: 13.2 A
- Maximum absorbed power: 2.8 kW
- Nominal absorbed power: 110 W
- Refrigerant: R452A
- Output: 1,318 W
- Nominal output: 1.9 HP
- Compressor type: E
- Fin spacing: 2.5 mm
- Fans: 1 x ø300 mm
- Airflow: 1,000 m³/h
- Air throw: 6 m
- Weight: 89 kg
- Volume: 0.80 m³
- Hermetic compressor
- Air-cooled condenser
- Galvanized sheet body
- Automatic reset high and low pressure switch
- Axial fan
- Hot gas defrost solenoid valve
- Condensate drain trap
- Condensate drain heater (BT models only)
- Ambient temperature sensor
- End-of-defrost sensor
- Condensation control sensor
- Power cable for door heater
- Micro-switch connection cable
- Digital display with temperature indication
- Operating status display:
Fjdjxvr Upopfx Aagsgi
- Cooling/defrost
- Evaporator fans
- Active alarm
- Programming keys
- Manual defrost button
- Audible alarm
- Low and high temperature alarm
- High condenser temperature alarm (dirty condenser)
- Low condenser temperature alarm
- Door open alarm
- High and low pressure alarm
- End-of-defrost time overrun alarm
- Faulty temperature sensor alarm
- Condensation control sensor failure alarm
- Evaporating temperature at -10°C for positive temperature (TN)
- Condensation temperature at +40°C for TN
- Evaporating temperature at -30°C for low temperature (BT)
- Condensation temperature at +40°C for BT
The listing was translated automatically. Translation errors are possible.
- Application range: -18 ÷ -22°C
- Evaporation temperature: -30°C
- Condensation temperature: +40°C
- Cold room temperature: -20°C
- Ambient temperature: 32°C
- Defrost: Hot gas
- Power supply: 230 V / 1+N ph / 50 Hz
- Maximum absorbed current: 13.2 A
- Maximum absorbed power: 2.8 kW
- Nominal absorbed power: 110 W
- Refrigerant: R452A
- Output: 1,318 W
- Nominal output: 1.9 HP
- Compressor type: E
- Fin spacing: 2.5 mm
- Fans: 1 x ø300 mm
- Airflow: 1,000 m³/h
- Air throw: 6 m
- Weight: 89 kg
- Volume: 0.80 m³
- Hermetic compressor
- Air-cooled condenser
- Galvanized sheet body
- Automatic reset high and low pressure switch
- Axial fan
- Hot gas defrost solenoid valve
- Condensate drain trap
- Condensate drain heater (BT models only)
- Ambient temperature sensor
- End-of-defrost sensor
- Condensation control sensor
- Power cable for door heater
- Micro-switch connection cable
- Digital display with temperature indication
- Operating status display:
Fjdjxvr Upopfx Aagsgi
- Cooling/defrost
- Evaporator fans
- Active alarm
- Programming keys
- Manual defrost button
- Audible alarm
- Low and high temperature alarm
- High condenser temperature alarm (dirty condenser)
- Low condenser temperature alarm
- Door open alarm
- High and low pressure alarm
- End-of-defrost time overrun alarm
- Faulty temperature sensor alarm
- Condensation control sensor failure alarm
- Evaporating temperature at -10°C for positive temperature (TN)
- Condensation temperature at +40°C for TN
- Evaporating temperature at -30°C for low temperature (BT)
- Condensation temperature at +40°C for BT
The listing was translated automatically. Translation errors are possible.
Documents
Seller
Note: Register for free or log in, to access all information.
Registered since: 2025
Send inquiry
Telephone & Fax
+33 1 84 ... show
Your listing has been deleted successfully
An error has occurred