Used Vötsch Microwave Oven for sale (1,258)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
7,009 km
Climatic test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Type: VCS 7034-5
Water-cooled climatic test chamber
Vötsch VCS 7034-5
Test chamber capacity 335 liters
Performance for temperature tests
Temperature range -70 to +180°C
Temperature deviation temporal K ±0.1 to ±0.5
Hsdpfxjuudx Ds Akrol
Spatial temperature deviation K ±0.5 to ±2.0
Temperature gradient 1 to 4
Rate of change :
Cooling 6.7 K/min
Heating 6.8 K/min
Heat compensation at +20 °C 3000 W / at -20°C 3000 W
Temperature calibration values +23 °C and +80 °C
Performance for climate tests
Temperature range +10 to +95°C
Temperature deviation in time ±0.1 to ±0.3 K
Spatial temperature deviation ±0.5 to ±1.0 K
Temperature gradient 1 to 2 K
Humidity range 10 to 98%
Humidity deviation in time ±1 to ±3%
Dew point range -3 to +94°C
Heat compensation 400W
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 580mm Depth 765mm Height 750mm
External dimensions: Width 870mm Depth 1595mm Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64dB(A)
Cooling water consumption: 1.4m³/h
Refrigerant: R-404A / R-23
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Heat cabinet with nitrogen supply
VötschTU 60/60 G-ISO Temp. 250°C
Call
Condition: excellent (used), Here we offer a bird heat cabinet with nitrogen supply.
Vötsch heat cabinet with nitrogen supply
Nominal temperature: 250°C
Name stream: 10 A
Connection value: 6.3 KVA
Nominal voltage: 400V3coma N)PE AC 50/60hz
Nominal power: 6 KW
Type: TU 60/60 G-ISO
Condition: used/used
Delivery: (See picture)
(Changes and errors in the technical data, information is reserved!)
We can answer more questions on the phone for you.
Hjded Ngg Tspfx Akrol
Listing
Borken
7,009 km
Shock test chamber –80 °C to +220 °C
VötschVT 7012 S2
Call
Condition: excellent (used), Vötsch
Model: VT 7012 S2
Shock Test Chamber, Air-cooled
Two-chamber design
Hot Chamber:
The temperature range of the hot chamber extends from +50°C to +220°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 11 K/min
Cold Chamber:
The cold chamber temperature range is from -80°C to +70°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Hjdpfx Akowxc I Uerol
Hot chamber temperature range: +50°C to +220°C
Cold chamber temperature range: -80°C to +70°C
Test chamber dimensions: Width 470 mm, Depth 650 mm, Height 410 mm
External dimensions: Width 930 mm, Depth 2115 mm, Height 1970+ mm
Port diameter: ∅ 67 mm
Voltage: 3/N/PE AC 400V +10% 50 Hz
Nominal power: 10 kW
Nominal current: 25 A
Refrigerants: R452-A / R23
Weight: 1,000 kg
Important information for your safety as a buyer!
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical details are subject to change and correction!)
For further questions, please feel free to contact us by phone.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Borken
7,009 km
Climate test chamber Temp. -70°C to +180°C
Vötsch 190 LiterVCS 7018-5
Call
Condition: excellent (used), Heraeus Vötsch
Type: VCS 7018-5
Climatic Test Chamber with Humidity Control, Water-Cooled
Test Chamber Dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing Dimensions: Width 870 mm x Depth 1280 mm x Height 1775 mm
Characteristics for Temperature Tests:
Temperature Range: -70°C to +180°C
Temperature Range: ± 0.1 to ± 0.5 K
Spatial Range: ± 0.5 to ± 2.0 K
Temperature Gradient: 1 to 4 K
Temperature Rate of Change according to IEC 60068-3-5
Heating: 7.5 K/min
Cooling: 7.5 K/min
Characteristic values for climatic tests:
Temperature range +10 to +95°C
Humidity range: 10 to 98% RH
Temperature deviation over time: ± 0.1 to ± 0.3 K
Temperature deviation over space: ± 0.5 to ± 1 K
Temperature gradient: 1 to 2 K
Humidity fluctuation over time: ± 1 to ± 3% RH F.
Dew point range -3 to +94 °C
Electrical connection:
Nominal voltage: 3/N/PE AC 400V±10% 50Hz
Nominal power: 10 kW
Nominal current: 21 A
Fuse protection: 32 A slow-blow, provided by the customer
Refrigerant: R-404A / R-23
Test chamber volume: approx. 190 liters
Weight: approx. 460 kg
For your safety, please note the following information!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Hedpfxev N Hc Ej Akrel
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Hodpfx Akjun Izcerel
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Oven
VötschNTU 60/60
Call
Year of construction: 1996, condition: good (used), Here we offer a Voetsch drying oven Waermeschrank Waermeofen.
Voetsch NTU 60/60 250°C
Nominal temperature: 250°C
Supply voltage:
400 V 3 (N) PE AC, 50/60 Hz
Interior dimensions: width 600 mm/height 600 mm/depth 600 mm
External dimensions: width 1000 mm/height 1675 mm/depth 1300 mm
Air circulation blower
Type: Voetsch NTU 60/60
Scope of delivery: (see picture)
(Changes and errors in the technical data are reserved!)
We will be happy to answer any further questions you may have on the phone.
Hodebqh I Sspfx Akrjl
Listing
Borken
7,009 km
With humidity 270 liters
VötschKlimaprüfschrank VCS³ 7027-10
Call
Condition: excellent (used), Vötsch
Type: VCS³ 7027-10
Vötsch Climatic Test Chamber, Water-Cooled
With a temperature change rate of 10 K/min
Temperature test data:
Temperature range -72°C to +180°C
Temperature deviation over time in the center of the work space ± 0.3 K to ± 0.5 K
Temperature deviation over space ± 0.5 K to ± 2.0 K
Temperature change rate
Heating: 10 K/min
Cooling: 14.5 K/min
Climatic test data:
Temperature range +10°C to +95°C
(Extended climatic range: 2°C/95% RH, controlled for a maximum of 2 hours)
Temperature deviation over time in the center of the work space ± 0.2 K to ± 0.3 K
Temperature deviation over space ± 0.5 K to ± 1.0 K
Humidity deviation in the center of the usable space: ± 1% to ± 3% RH
Humidity range: 10% to 98% RH
(Extended climate range: 2°C/95% RH, regulated for a maximum of 2 hours)
External dimensions: Width 780 x Depth 1895 x Height 1775 (mm)
Test chamber dimensions: Width 580 x Depth 615 x Height 750 (mm)
Test chamber volume: approx. 270 liters
Side opening 50 mm
Side opening 125 mm
Operating data:
LED strip 24 V, 6.8 W / 2 x halogen bulb 24 V, 50 W
Rated voltage: 3/N/PE AC 400 V±10%, 50 Hz
Rated power: 14 kW
Hodpfx Akov R Ty Torol
Rated current: 26 A
Fuse, on-site: 63 A slow-blow
Refrigerant R404A/R-23
Weight approx. 835 kg
For your safety, please note the following information as a buyer!
The following steps are performed on our offered chambers in advance:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Temperature cabinet 110 liters
VötschVT 7011 -70°C bis +180°C
Call
Condition: excellent (used), Here we offer a Heraeus Vötsch temperature cabinet.
Heraeus Vötsch temperature chamber water cooled
Test chamber volume 110 liters
Test chamber dimensions: Width 560 mm Depth 350 mm Height 630 mm
Outer dimensions: Width 850 mm Depth 1030 mm Height 1640 mm
Temperature range - 70°C to +180°C
Temperature deviation in time ±0.1 to ±0.5 K
Temperature deviation spatial ±0.5 to ±1.5 K
Temperature gradient 1 to 3 K
Temperature change rate cooling 3.2 K/min
Temperature change rate heating 3,5 K/min
Refrigerant: R-404 A / R 23
Voltage 1/N/PE AC 230V±10% 50Hz
Rated power 1,8 kW
Rated current 12 A
Type: VT 7011
For you as a buyer for safety the following information!
Hjdshrdy Sopfx Akrol
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,009 km
Dryer for coating materials
VötschLTU 60/60
Call
Condition: excellent (used), Vötsch
Type: LTU 60/60
Heraeus Vötsch dryer for coating materials
Maximum concentration of flammable substances of 40 % of the lower explosion limit (LEL)
Highest temperature of the heating surface above 750 °C
Device description:
Technical data:
Interior (usable space) 0.216 m3
Internal dimensions: Width 600 mm Height 600 mm Depth 600 mm
External dimensions: Total width 796 mm Height 1725 mm Depth 850 mm
Loading / load capacity
Total roller conveyor 55 kg
Loading height above installation floor 820 mm
Weight (net) kg 275
Minimum exhaust air volume flow 96 m3/h
Purge time 5-fold air change 90 sec.
Increased recirculation air volume flow 33 m3/h
Total vapor space 0.414 m3
Sound pressure level (according to DIN 45635) < 70 dB(A)
Switch-off temperature
Temperature limiter (TB) fixed setting 300 °C
Temperature selector limiter (TWB) adjustable above nominal temperature 20
Temperature safety class (according to EN 60519-2)
Temperature limiter (TB) 1
Temperature selector limiter (TWB) 2
Nominal temperature 200 °C
Electrical data
Rated voltage / frequency 400V, 3/(N)PE, AC 50/60 Hz
Rated current 12.0 A
Nominal power 6.0 kW
Hedpfxeun Rr Rj Akrsl
Connected load 7.0 kW
Weight: 275kg
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Hedpfxsun Rulj Akrol
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Dryer for coating materials
VötschLTU 60/60 LTU 60/60 200 °C
Call
Condition: excellent (used), Here we offer you a Heraeus Vöstch dryer for coating materials.
Maximum concentration of flammable substances of < 40 % of the lower explosion limit (LEL).
Highest temperature of the heating surface above 750 °C
Equipment description:
Technical data:
Interior (usable space) 0.216 m3
Inner dimensions: width 600 mm height 600 mm depth 600 mm
External dimensions: Total width 796 mm Height 1725 mm Depth 850 mm
Loading / load capacity
Roller conveyor total 55 kg
Loading height above installation floor 820 mm
Weight (net) kg 275
Minimum exhaust air volume flow 96 m3/h
Purge time 5-fold air change 90 sec.
Recirculation air volume flow increased 33 m3/h
Total steam space 0.414 m3
Sound pressure level (according to DIN 45635) < 70 dB(A)
Switch-off temperature
Temperature limiter (TB) fixed 300 °C
Temperature selector limiter (TWB) adjustable above nominal temperature 20
Temperature safety class (according to EN 60519-2)
Temperature limiter (TB) 1
Over-temperature limit controller (TWB) 2
Nominal temperature 200 °C
Electrical data
Rated voltage / frequency 400V, 3/(N)PE, AC 50/60Hz
Rated current 12.0 A Rated power 6.0 kW Connected load 7.0 kW
Hjdshv Ru Sopfx Akrol
Weight: 275kg
Type: LTU 60/60
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,009 km
Temperature test chamber
Heraeus VötschVTS 7033
Call
Condition: excellent (used), Heraeus Vötsch temperature test chamber
Hsdpfslt U Avjx Akrol
Here we offer you a Heraeus Vötsch temperature test chamber.
Vötsch temperature test chamber VTS 7033 water cooled
Temperature range: -70°C to +180°C
Temperature deviation temporal ± 0,5 K
Temperature deviation temporal ± 1,5 K
Heating speed: 7,5 K/min
Cooling rate: 6.5 K/min
Test chamber dimensions: Width 825 mm x depth 800 mm x height 870 mm
housing dimensions: 1080 mm x 1710 mm x 1950 mm
lateral passage 12cm and 13cm
voltage: 400V+6/-10%,3/N, 50Hz
nominal power 9,5 kW nominal current 22 A
refrigerant R404A / R23
approx. 570 liters weight: 580 kg
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored by calibrated equipment.
Type: VTS 7033
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,009 km
Climatic chamber
VötschVCS 7033
Call
Condition: excellent (used), Heraeus Vötsch climatic chamber
Here we offer you a Heraeus Vötsch climatic chamber.
Vötsch climatic chamber VCS 7033 water cooled
Temperature range: -70°C to +180°C
Temperature change rate:
Heating 7.5 K/min.
Cooling 6,5 K/min.
Humidity range: 10% to 98% r.H.
Temperature deviation temporal ± 0.5 K
Temperature deviation time-related ± 1.5 K
Test chamber dimensions: Width 675 mm x Depth 650 mm x Height 760 mm
Housing dimensions: Width 930 mm x depth 1565 mm x height 1840 mm
Lateral feedthrough 90mm ∅
approx. 330 L Weight: 600 kg
voltage: 3/N/PE AC 400V ±6/-10% 50Hz
rated power 9,5 kW
Rated current 17 A
Refrigerant R404A / R23
Type: VCS 7033
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
Hedjpz H Hxjpfx Akrol
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,009 km
Temperature test chamber
VötschVTS³ 7018-5
Call
Condition: excellent (used), Vötsch
Type: VTS³ 7018-5
Water-cooled
Test chamber dimensions: Width 580 mm x depth 450 mm x height 750 mm
Housing dimensions: Width 900 mm x depth 1550 mm x height 1850 mm
Temperature test:
Temperature range: -70°C to +180°C
Temperature change rate: Heating 7.5 K/min
Temperature change rate: cooling 7.5 K/min
Test chamber volume: 190 liters
Nominal voltage: 400V
Rated current: 20 A
Rated power: 9 kW
Weight: approx. 540 kg
Refrigerant: R404A and R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Hsdpfxen E Sk Ee Akrjl
Listing
Borken
7,009 km
Assemblies / Test cabinet
VötschVT 3050 -30°C / +100°C 500 Liter
Call
Condition: excellent (used), Vötsch
Type: VT 3050
Modules / Test Chamber Temperature Chamber
Air-cooled
Test chamber capacity 500 litres
Temperature range -30°C / +100°C
Temporal temperature fluctuation K ±0.5
Spatial temperature fluctuation K ±1.5
Hodpfow S E N Tox Akrsl
Temperature gradient K 3
Change rate
Heating K/min 2.0
Cooling K/min 1.4
Heat compensation max. W 650
Calibration values +23°C +80°C
Test chamber dimensions Width 710 mm Depth 590 mm Height 1250 mm
External dimensions Width 940 mm Depth 1030 mm Height 1955 mm
Sound pressure level db(A)
Listing
Borken
7,009 km
Temperature test chamber spraying device
VötschVBT 03/500 500 Liter -30 bis 80°C
Call
Condition: excellent (used), Vötsch
Type: VBT 03/500
Air-cooled
Temperature test chamber with spray device
Technical description:
Data for temperature tests without water:
Temperature range -30°C to +80°C
Temperature deviation in steady state
according to IEC 60068-3-5 dependent on the test chamber temperature
over time ± 1 K
Temperature change rate according to IEC 60068-3-5
Heating: approx. 2 K/min.
Cooling: approx. 2 K/min.
Data for temperature tests with water
Temperature range +5°C to +80°C
Possible water level -10 mm to 540 mm
Water level = -10 mm
The water level is below the insert grid
Water level = 0 mm
The water level is at the top edge of the insert grid
Data for standard spray device
Number of spray nozzles: 6
Spray volume per nozzle: 0.5 l/min
Data for spray device according to EN 539-2, Method B
Number of spray nozzles: 6
Spray volume per nozzle: 4.5 l/min
Additional flooding nozzles: 2
Spray volume of additional nozzle: 6 l/min
Compressed air consumption: approx. 3 m³/h
Data for water tank with pre-temperature control
Volume: approx. 2000 l
Temperature range for pre-temperature control +5°C to +40°C
Temperature change duration
Hedpfx Aewc Nvgskrsl
Cooling of +18°C to +5°C approx. 15 h
Heating from +15°C to +40°C approx. 10 h
Installation and Operation Data:
Test chamber: Width 1120 mm, Depth 840 mm, Height 540 mm
Housing: Width 2700 mm, Depth 1300 mm, Height 1575 mm
Water tank: Width 1100 mm, Depth 800 mm, Height 2200 mm
Plug-ins
1 50 mm diameter plug installed on the left
Test chamber capacity: approx. 500 liters
Refrigerant R-404a
Electrical connection:
Nominal voltage 3/N/PE AC 400V ± 10% 50Hz
Nominal power approx. 26 kW
Nominal current approx. 44.0 A (neutral conductor loaded)
Fuse protection 63 A gG, on-site
Weight approx. 890 kg net
For your safety, please note the following information!
The following steps are carried out on our chambers in advance:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Temperature cabinet
VötschVTS 7011-5
Call
Condition: good (used), Vötsch
Type: VTS 7011-5
Heraeus Vötsch temperature chamber, water-cooled
Test chamber volume 110 liters
Test chamber dimensions: Width 560 mm Depth 350 mm Height 630 mm
External dimensions: Width 850 mm Depth 1030 mm Height 1640 mm
Temperature range - 70°C to +180°C
Temperature deviation in time ± 0.3 to 1 K
Spatial temperature deviation ± 0.5 to ± 2 K
Hsdpjum Uzmefx Akrsl
Temperature change rate cooling 6 K/min
Temperature change rate heating 10 K/min
Refrigerant: R-404 A / R 23
Voltage 3/N/PE AC 400V±10% 50Hz
Rated power 7.5 kW
Rated current 13 A
Weight: 360 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Hodsun Rv Nopfx Akrsl
Listing
Borken
7,009 km
Climatic test chamber -70°C to +180°C
VötschVCS 7034-5 - 335 Liter
Call
Condition: used, Vötsch
Type: VCS 7034-5
Water-cooled climatic test chamber
Test chamber capacity 335 liters
Performance for temperature tests
Temperature range -70 to +180°C
Hjdpfx Aeuxq T Dskrjl
Temperature deviation in time K ±0.1 to ±0.5
Spatial temperature deviation K ±0.5 to ±2.0
Temperature gradient 1 to 4
Rate of change :
Cooling 6.7 K/min
Heating 6.8 K/min
Heat compensation at +20 °C 3000 W / at -20°C 3000 W
Temperature calibration values +23 °C and +80 °C
Performance for climate tests
Temperature range +10 to +95°C
Temperature deviation in time ±0.1 to ±0.3 K
Spatial temperature deviation ±0.5 to ±1.0 K
Temperature gradient 1 to 2 K
Humidity range 10 to 98%
Humidity deviation in time ±1 to ±3%
Dew point range -3 to +94°C
Heat compensation 400W
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 580mm Depth 765mm Height 750mm
External dimensions: Width 870mm Depth 1595mm Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64dB(A)
Cooling water consumption: 1.4m³/h
Refrigerant: R-404A / R-23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Shock test chamber
VötschVT 7012 S3
Call
Condition: excellent (used), Vötsch shock test chamber
Here we offer you a Vötsch shock test chamber.
Water cooled
Temp. range -80C to +220C
Hot chamber +50 to +220
Medium chamber -10 to +90
Cold chamber -80 to +70
Mains voltage 400V +-10% 3/N 50Hz
Rated current 30.5 A
Rated power 13.5 KW
Refrigerant VK : R 404A 3.00kg p*: 25bar
Refrigerant TK : R23 15bar p* : 25 bar
Condition: used / used
Type: VT 7012 S3
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
Hsdon Avcuepfx Akrol
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,009 km
Temperature test chamber 270 liters
VötschVTS³ 7027-25 -72°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VTS³ 7027-25
Heraeus Vötsch temperature test chamber, water-cooled
Performance data:
With temperature change rate of 25 K/min
Test chamber dimensions Height 750 mm Width 580 mm Depth 615 mm
External dimensions Height 1775 mm Width 780 mm Depth 1895 mm
Temperature range -72°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5
Temperature homogeneity in space ± 0.5 to ± 2.0
Temperature change rate cooling 25 K/min
Temperature change rate heating 25 K/min
Heat compensation at -20 °C 8000 W
Heat compensation at +20 °C 8000 W
Test volume: 270 liters
2x lateral feed-through ∅ 125 cm
1x side feed-through ∅ 50 cm
Cabinet is water-cooled
Test room lighting:
Hedpfx Aketz Rqmjrjl
LED strip 24 V, 6.8 W / 2x halogen bulb 24 V, 50 W
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal power: 26 KW
Rated current: 44 A
Refrigerant: R-452A and R-23
Weight: approx. 980 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
7,009 km
Climate test chamber with humidity 190 liters
VötschVC 7018 -70 bis 180°C
Call
Condition: excellent (used), Vötsch
Hjdpfx Aowgaykskrol
Type: VC 7018
Vötsch Climatic Test Chamber VC 7018 Water-Cooled
Touch Panel Control Unit
On the touch panel control unit, all control and operating commands can be triggered by simply touching the function symbols.
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Ports
The test chamber is equipped with port holes on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Feedthrough included in standard equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Characteristics for temperature tests:
Temperature range: -70°C to +180°C
Temperature ±0.1 to ±0.5 K
Spatial ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min
Cooling: 2.3 K/min
Characteristics for climatic tests:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% r.h. F.
Temperature deviation over time in the center of the usable space ± 0.1 to ± 0.3 K
Temperature deviation over space ± 0.5 to ± 1.0 K
Temperature gradient 1 to 2 K
Humidity deviation over time in the center of the usable space ± 1 to ± 3 %RH
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10 50Hz
Nominal power: 5.9 kW
Nominal current: 12.0 A
Connection cable: 3.5 m
Fuse protection: 16 A slow-blow, provided by the customer
Refrigerants: R-404A and R-23
Test chamber capacity: approx. 190 liters
Weight: approx. 460 kg net
For your safety, the following information is provided as a buyer!
The following steps are performed on our offered chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Temperature test chamber -70°C to +180°C
VötschVTS 7018-5 190 Liter
Call
Condition: excellent (used), Vötsch
Model: VTS 7018-5
Water-cooled Temperature Test Chamber
System retrofitted with R-452A
Temperature range: -70°C to +180°C
Temporal temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature change rate cooling: 7.5 K/min
Temperature change rate heating: 7.5 K/min
Heat compensation at +20°C: 3000 W
Heat compensation at -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 450 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1280 mm, Height 1575 mm
Test chamber volume: 190 liters
Rated voltage: 3/N/PE AC, 400V ±10%, 50Hz
Rated power: 10.0 kW, Rated current: 21 A
Main fuse (on-site): 32 A slow-blow
Sound level at 1m distance (free-field measurement): < 69dB (A)
Hjdpfxewq Iyme Akrel
Side port: 50 mm / 125 mm
Chamber is water-cooled
Refrigerants: R-452A and R 23
Weight approx. 460 kg
For your safety as a buyer, the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, new charging with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (See picture)
(Technical data may be subject to change or error!)
If you have any further questions, we will be happy to answer them by phone.
Listing
Borken
7,009 km
Climate test chamber 1300 liters with humidity control
VötschVCS 7130-15 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Model: VCS 7130-15
Vötsch Climate Test Chamber, Water-Cooled
Temperature Test Data:
Temperature range: -70°C to 180°C
Temporal temperature deviation at center of workspace: ±0.3 to ±0.8 K
Spatial temperature deviation: ±0.5 to ±2 K
Temperature gradient: 1 to 4 K
Temperature change rate:
Heating: 16 K/min
Cooling: 14.5 K/min
Climate Test Data:
Temperature range: +10°C to +95°C
Humidity range: 10 to 98% RH
Temporal temperature deviation at center of workspace: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1 K
Hsdpfx Aowvgwbskrol
Temperature gradient: 1 to 2 K
Temporal humidity fluctuation at center of workspace: ±1 to ±3% RH
Maximum heat compensation: 8000 W
Enclosure dimensions:
External dimensions with hinges and door lock:
Height: 1995 mm, Width: 1680 mm, Depth: 1855 mm
External dimensions without hinges and door lock:
Height: 1995 mm, Width: 1300 mm, Depth: 1855 mm
Internal dimensions:
Height: 950 mm, Width: 1100 mm, Depth: 950 mm
Test chamber volume: approx. 1300 liters
Feedthroughs:
The test chamber is equipped with feedthroughs on both the right and left sides. These allow for test leads and testing devices to be routed into the chamber.
1 x R1 NW 125 mm
1 x R1 NW 140 mm
1 x L1 NW 50 mm
Test chamber illumination:
Halogen bulb 24V, 50W
Power supply: 3/N/PE AC 400V ±10% 50Hz
Rated power: 44.0 kW
Rated current: 63.0 A
Customer-provided fuse: 100 A slow-blow
Maximum heat output to the environment: 2.2 kW
Permissible test item weight:
Total load on shelf supports: 100 kg
Test chamber floor: 150 kg, Removable shelf: 50 kg
Refrigerants: R 404A/R 23
Weight: 1900 kg
For your security as a buyer, please note:
The following steps are carried out in advance on our chambers offered for sale:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Subject to changes and errors in the technical data and specifications!)
We are happy to answer any further questions by phone.
Listing
Borken
7,009 km
Temperature test chamber 335 liters
VötschVTS 7034-5 -70°C bis +180°C
Call
Condition: excellent (used), Heraeus Vötsch temperature test chamber
Here we offer you a Heraeus Vötsch temperature test chamber.
Heraeus Vötsch temperature test chamber water cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6,5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Hedpfx Akeir D U Derel
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
Outer dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free field measurement) < 69dB (A)
side entry 5,5 cm / 12,5 cm
cabinet is water cooled
Refrigerant: R 452A and R 23
weight approx. 570 kg
Type: VTS 7034-5
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
We make it easier for you to find: "vötsch microwave oven"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month





















































































































































































































