Used Vötsch Oven for sale (1,114)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
7,009 km
Climatic test chamber -70°C to +180°C
VötschVCS 7034-5 - 335 Liter
Call
Condition: used, Vötsch
Type: VCS 7034-5
Water-cooled climatic test chamber
Test chamber capacity 335 liters
Performance for temperature tests
Temperature range -70 to +180°C
Temperature deviation in time K ±0.1 to ±0.5
Spatial temperature deviation K ±0.5 to ±2.0
Temperature gradient 1 to 4
Rate of change :
Cooling 6.7 K/min
Heating 6.8 K/min
Heat compensation at +20 °C 3000 W / at -20°C 3000 W
Temperature calibration values +23 °C and +80 °C
Performance for climate tests
Temperature range +10 to +95°C
Temperature deviation in time ±0.1 to ±0.3 K
Spatial temperature deviation ±0.5 to ±1.0 K
Temperature gradient 1 to 2 K
Humidity range 10 to 98%
Humidity deviation in time ±1 to ±3%
Dedpouxq T Defx Akgjkn
Dew point range -3 to +94°C
Heat compensation 400W
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 580mm Depth 765mm Height 750mm
External dimensions: Width 870mm Depth 1595mm Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64dB(A)
Cooling water consumption: 1.4m³/h
Refrigerant: R-404A / R-23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Climate test chamber with humidity 190 liters
VötschVC 7018 -70 bis 180°C
Call
Condition: excellent (used), Vötsch
Type: VC 7018
Vötsch Climatic Test Chamber VC 7018 Water-Cooled
Touch Panel Control Unit
On the touch panel control unit, all control and operating commands can be triggered by simply touching the function symbols.
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Ports
The test chamber is equipped with port holes on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Feedthrough included in standard equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Characteristics for temperature tests:
Temperature range: -70°C to +180°C
Temperature ±0.1 to ±0.5 K
Spatial ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min
Cooling: 2.3 K/min
Characteristics for climatic tests:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% r.h. F.
Temperature deviation over time in the center of the usable space ± 0.1 to ± 0.3 K
Temperature deviation over space ± 0.5 to ± 1.0 K
Temperature gradient 1 to 2 K
Humidity deviation over time in the center of the usable space ± 1 to ± 3 %RH
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10 50Hz
Nominal power: 5.9 kW
Nominal current: 12.0 A
Connection cable: 3.5 m
Fuse protection: 16 A slow-blow, provided by the customer
Refrigerants: R-404A and R-23
Test chamber capacity: approx. 190 liters
Weight: approx. 460 kg net
For your safety, the following information is provided as a buyer!
The following steps are performed on our offered chambers in advance:
1. Functional testing and replacement of necessary components
Dkodpfx Akowgaykegjn
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Shock test chamber
VötschVT 7012 S3
Call
Condition: excellent (used), Vötsch shock test chamber
Here we offer you a Vötsch shock test chamber.
Water cooled
Temp. range -80C to +220C
Hot chamber +50 to +220
Medium chamber -10 to +90
Cold chamber -80 to +70
Mains voltage 400V +-10% 3/N 50Hz
Rated current 30.5 A
Rated power 13.5 KW
Refrigerant VK : R 404A 3.00kg p*: 25bar
Refrigerant TK : R23 15bar p* : 25 bar
Condition: used / used
Type: VT 7012 S3
Dsdpfjn Avcuex Akgokn
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,009 km
Temperature test chamber 270 liters
VötschVTS³ 7027-25 -72°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VTS³ 7027-25
Heraeus Vötsch temperature test chamber, water-cooled
Performance data:
With temperature change rate of 25 K/min
Test chamber dimensions Height 750 mm Width 580 mm Depth 615 mm
External dimensions Height 1775 mm Width 780 mm Depth 1895 mm
Temperature range -72°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5
Dedjtz Rqmopfx Akgjkn
Temperature homogeneity in space ± 0.5 to ± 2.0
Temperature change rate cooling 25 K/min
Temperature change rate heating 25 K/min
Heat compensation at -20 °C 8000 W
Heat compensation at +20 °C 8000 W
Test volume: 270 liters
2x lateral feed-through ∅ 125 cm
1x side feed-through ∅ 50 cm
Cabinet is water-cooled
Test room lighting:
LED strip 24 V, 6.8 W / 2x halogen bulb 24 V, 50 W
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal power: 26 KW
Rated current: 44 A
Refrigerant: R-452A and R-23
Weight: approx. 980 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Temperature test chamber 335 liters
VötschVTS 7034-5 -70°C bis +180°C
Call
Condition: excellent (used), Heraeus Vötsch temperature test chamber
Here we offer you a Heraeus Vötsch temperature test chamber.
Heraeus Vötsch temperature test chamber water cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Dodsir D U Dspfx Akgekn
Temperature deviation in time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6,5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
Outer dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free field measurement) < 69dB (A)
side entry 5,5 cm / 12,5 cm
cabinet is water cooled
Refrigerant: R 452A and R 23
weight approx. 570 kg
Type: VTS 7034-5
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,009 km
Temperature test chamber -70°C to +180°C
VötschVTS 7018-5 190 Liter
Call
Condition: excellent (used), Vötsch
Model: VTS 7018-5
Water-cooled Temperature Test Chamber
System retrofitted with R-452A
Temperature range: -70°C to +180°C
Temporal temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature change rate cooling: 7.5 K/min
Temperature change rate heating: 7.5 K/min
Heat compensation at +20°C: 3000 W
Heat compensation at -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 450 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1280 mm, Height 1575 mm
Test chamber volume: 190 liters
Rated voltage: 3/N/PE AC, 400V ±10%, 50Hz
Rated power: 10.0 kW, Rated current: 21 A
Main fuse (on-site): 32 A slow-blow
Sound level at 1m distance (free-field measurement): < 69dB (A)
Side port: 50 mm / 125 mm
Chamber is water-cooled
Refrigerants: R-452A and R 23
Weight approx. 460 kg
For your safety as a buyer, the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
Dkodpfowq Iymex Akgsn
2. If required, new charging with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (See picture)
(Technical data may be subject to change or error!)
If you have any further questions, we will be happy to answer them by phone.
Listing
Borken
7,009 km
Shock test chamber -80°C to +220°C
VötschVT 7012 S2
Call
Condition: excellent (used), Here we offer Vötsch shock test chamber.
Temperature shock test chamber water cooled
Two-chamber design
Warm chamber:
The temperature control of the warm chamber ranges from +50°C to +220°C
Temperature deviation in time in the center of the chamber ± 1 K
Temperature deviation spatially ± 2 K
Temperature change rate
heating 11 K/min
cold chamber:
the cold chamber from -80°C to +70°C
Temperature deviation temporally in useful space center ± 1 K
temperature deviation spatially ± 2 K
Temperature change rate
heating 2 K/min
cooling 3 K/min
Test chamber volume 125 liters
Temperature range hot chamber +50°C to +220°C
Temperature range cold chamber -80°C to +70°C
Test chamber dimensions width 470mm depth 650mm height 410mm
Outer dimensions width 930mm depth 2115mm height 1970+mm
Dodpjigg Hnsfx Akgjkn
Feedthrough ∅ 67mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant R404A / R23
Weight: 1000 kg
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: VT 7012 S2
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,009 km
Temperature test chamber -70°C to +180°C
VötschVT 7021
Call
Condition: excellent (used), Heraeus Vötsch
Type: VT 7021
Air-cooled temperature test chamber
1 port, nominal width 80 mm,
Test chamber volume: 210 liters
Temperature range: -70°C to +180°C
Temporal temperature deviation: ± 0.2 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (heating): 2.5 K/min
Temperature change rate (cooling): 2.5 K/min
Max. heat compensation: 800 W
Test chamber dimensions: Width 560 mm, Depth 570 mm, Height 630 mm
External dimensions: Width 850 mm, Depth 1250 mm, Height 1640 mm
Electrical connection: 1/NPE AC 230 V ± 10% 50 Hz
Rated power approx. 1.8 kW, rated current 12 A
Refrigerant: R404A and R23
Weight: 355 kg
For your safety as a buyer, please note the following information!
Dsdjwylv Djpfx Akgjkn
The following procedures are performed on the chambers we offer, in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Subject to technical modifications and errors in the details!)
For further questions, please feel free to contact us by phone.
Listing
Borken
7,009 km
Climate test chamber 1300 liters with humidity control
VötschVCS 7130-15 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Model: VCS 7130-15
Vötsch Climate Test Chamber, Water-Cooled
Temperature Test Data:
Temperature range: -70°C to 180°C
Temporal temperature deviation at center of workspace: ±0.3 to ±0.8 K
Spatial temperature deviation: ±0.5 to ±2 K
Temperature gradient: 1 to 4 K
Temperature change rate:
Heating: 16 K/min
Cooling: 14.5 K/min
Climate Test Data:
Temperature range: +10°C to +95°C
Humidity range: 10 to 98% RH
Temporal temperature deviation at center of workspace: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1 K
Temperature gradient: 1 to 2 K
Temporal humidity fluctuation at center of workspace: ±1 to ±3% RH
Maximum heat compensation: 8000 W
Enclosure dimensions:
External dimensions with hinges and door lock:
Height: 1995 mm, Width: 1680 mm, Depth: 1855 mm
External dimensions without hinges and door lock:
Height: 1995 mm, Width: 1300 mm, Depth: 1855 mm
Internal dimensions:
Height: 950 mm, Width: 1100 mm, Depth: 950 mm
Test chamber volume: approx. 1300 liters
Feedthroughs:
The test chamber is equipped with feedthroughs on both the right and left sides. These allow for test leads and testing devices to be routed into the chamber.
1 x R1 NW 125 mm
1 x R1 NW 140 mm
1 x L1 NW 50 mm
Test chamber illumination:
Halogen bulb 24V, 50W
Power supply: 3/N/PE AC 400V ±10% 50Hz
Rated power: 44.0 kW
Rated current: 63.0 A
Customer-provided fuse: 100 A slow-blow
Maximum heat output to the environment: 2.2 kW
Permissible test item weight:
Total load on shelf supports: 100 kg
Test chamber floor: 150 kg, Removable shelf: 50 kg
Refrigerants: R 404A/R 23
Weight: 1900 kg
For your security as a buyer, please note:
Djdswvgwbopfx Akgokn
The following steps are carried out in advance on our chambers offered for sale:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Subject to changes and errors in the technical data and specifications!)
We are happy to answer any further questions by phone.
Listing
Borken
7,009 km
Dryer for coating materials
VötschLTU 60/60
Call
Condition: excellent (used), Vötsch
Type: LTU 60/60
Heraeus Vötsch dryer for coating materials
Maximum concentration of flammable substances of 40 % of the lower explosion limit (LEL)
Highest temperature of the heating surface above 750 °C
Device description:
Technical data:
Interior (usable space) 0.216 m3
Internal dimensions: Width 600 mm Height 600 mm Depth 600 mm
External dimensions: Total width 796 mm Height 1725 mm Depth 850 mm
Loading / load capacity
Dodpfxsun Rrqe Akgokn
Total roller conveyor 55 kg
Loading height above installation floor 820 mm
Weight (net) kg 275
Minimum exhaust air volume flow 96 m3/h
Purge time 5-fold air change 90 sec.
Increased recirculation air volume flow 33 m3/h
Total vapor space 0.414 m3
Sound pressure level (according to DIN 45635) < 70 dB(A)
Switch-off temperature
Temperature limiter (TB) fixed setting 300 °C
Temperature selector limiter (TWB) adjustable above nominal temperature 20
Temperature safety class (according to EN 60519-2)
Temperature limiter (TB) 1
Temperature selector limiter (TWB) 2
Nominal temperature 200 °C
Electrical data
Rated voltage / frequency 400V, 3/(N)PE, AC 50/60 Hz
Rated current 12.0 A
Nominal power 6.0 kW
Connected load 7.0 kW
Weight: 275kg
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Temperature test chamber 680 liters
Heraeus VötschVLM 3068/S -30 °C bis +125 °C
Call
Year of construction: 2010, condition: excellent (used), Here we offer you a Heraeus Vötsch temperature test chamber.
Vötsch temperature test chamber VLM 3068/S air-cooled
(building material test chambers loaded from above)
Control panel
The control panel is mounted on a console on the temperature test chamber. By
control and operating commands can be triggered by simply touching the function symbols.
can be triggered. The operating instructions for the control panel are enclosed
Main switch
The main switch is located at the front of the temperature test chamber.
Air treatment room
The air treatment room is located in the test room
and contains the components required for temperature control.
In the air treatment room, the air is tempered (cooling/heating) and circulated by the test room fan.
circulated by the test room fan. The air is sucked in at the center of the side wall and
enters the test chamber again via the air baffles on the long sides.
Feed-throughs
The temperature test chamber can optionally be equipped with feed-throughs. Through these
can be used to route cables and test equipment into the test chamber.
Entry port front 2 x 82 mm ∅ rear 1 x 85 mm ∅
Internal dimensions Width 2000 mm Depth 570 mm Height 600 mm
External dimensions Width 3000 mm Depth 870 mm Height 1060 mm
Dkedpfxerbiyfs Akgon
Technical data:
Data for mechanical load:
Max. load with test material
Test area floor
(evenly distributed over the surface) 600 kg
Point load 50 kg
Data for temperature tests:
Temperature range -30 °C to +125 °C
Temperature deviation over time in the center of the usable space ±1 K
Temperature change rate
Heating approx. 1 K/min
Cooling approx. 2 K/min
Data for operation:
Nominal voltage 3/N / PE AC 400 V ±10% 50 Hz
Rated power 3 kW Rated current 9 A
Customer fuse 16A slow-blow
Temperature test chamber VLM 3068/S
Test chamber volume approx. 680 l
Weight approx. 700 kg
Refrigerant: R-404A
Noise measurement Sound pressure level approx. 68 dB(A)
Type: VLM 3068/S
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Heating and drying cabinet 250°C
Heraeus VötschVTL 60/60
Call
Condition: excellent (used), Vötsch
Type: VTL 60/60
The Vötsch VTL 60/60 is an industrial heating and drying cabinet,
specifically designed for the safe drying of coated materials,
such as paints and resins.
It meets the safety requirements of EN 1539 and is therefore suitable for processes where flammable solvents may be released.
Technical specifications:
Usable volume: 0.216 m³ (600 × 600 × 600 mm)
Nominal temperature: 250 °C
Maximum heating surface temperature: over 750 °C
Nominal power: 7.2 kW
Connected load: 8 kW
Dkodpjwgcxcjfx Akgjn
Minimum exhaust air flow rate: 102 m³/h
External dimensions (L × W × H): 1150 × 1000 × 1700 mm
Weight: approx. 250 kg
Safety features:
The VTL 60/60 is equipped with a powerful recirculation fan, which ensures even temperature distribution and effective dilution of solvent vapors.
This prevents the formation of explosive atmospheres and ensures safe operation.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Shock test chamber –75°C to +220°C
VötschVT 7012 S2
Call
Condition: excellent (used), Vötsch
Model: VT 7012 S2
Water-cooled
Two-chamber configuration
Hot chamber:
Temperature range of hot chamber: +50°C to +220°C
Temporal temperature deviation at the center of useful space: ±1 K
Spatial temperature deviation: ±2 K
Temperature change rate:
Heating: 11 K/min
Cold chamber:
Temperature range of cold chamber: -74.5°C to +70°C
Temporal temperature deviation at the center of useful space: ±1 K
Spatial temperature deviation: ±2 K
Temperature change rate:
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Temperature range hot chamber: +50°C to +220°C
Temperature range cold chamber: -80°C to +70°C
Test chamber dimensions: width 470 mm, depth 650 mm, height 410 mm
External dimensions: width 930 mm, depth 2115 mm, height 1970+ mm
Dedsx Hhfhspfx Akgokn
Port diameter: 67 mm
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Rated power: 10 kW
Rated current: 25 A
Refrigerants: R-452A / R-23
Weight: 1000 kg
Important safety information for buyers:
The following actions are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Recharging with legally compliant refrigerant
3. Leak test with certificate
4. After a successful check, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Subject to changes and errors in technical data and specifications!)
We are happy to answer further questions by phone.
Listing
Borken
7,009 km
Climate test chamber 190 liters
VötschVC³ 7018 -70°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VC³ 7018
Dkjdpox Hg Uuefx Akgen
Vötsch Air-Cooled Climatic Test Chamber
Temperature Test:
Temperature Range: -70°C to +180°C
Temperature Rate: Heating 4 K/min
Temperature Rate: Cooling 3 K/min
Climatic Test:
+10°C to +95°C
Humidity Range: 10% to 98% RH F.
Temperature deviation over time: ± 0.1 to ± 0.3 K
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1550 mm x Height 1800 mm
Test chamber volume: 190 liters
Nominal voltage: 400 V
Nominal current: 14 A
Nominal power: 5.5 kW
Heat compensation 1500 W (at 20+)
Weight: approx. 460 kg
For your safety, please note the following information!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
-50°C to +220°C, -80 to +70°C, 60 liters
VötschVT³ 7006 S2 Temperaturschockschrank
Call
Condition: excellent (used), Vötsch
Type: VT³ 7006 S2-M
Water-cooled
Technical Specifications:
Maximum specimen weight: 20 kg
Test chamber volume: 60 liters
Test chamber internal dimensions: Width 380 mm, Depth 430 mm, Height 370 mm
External dimensions: Width 875 mm, Depth 1970 mm, Height 1895 mm
Vertical arrangement of hot and cold chambers (chamber change via lift carriage)
Temperature range of hot chamber: +50 °C to +220 °C (calibration value +125 °C)
Temperature range of cold chamber: -80 °C to +70 °C (calibration value -40 °C)
Uniform temperature distribution in the test chamber (±0.5 K to ±2.0 K)
Temporal temperature deviation: ±0.3 K to ±1.0 K
80 mm duct for measurement/supply connections to the specimen
SIMCONTROL software for operation and status display
Voltage: 3/N/PE AC 400V±10% 50Hz
Rated power: 8.5 kW
Rated current: 25 A
Refrigerants: R-404A, R-23
Weight: approx. 800 kg
Important information for your safety as a buyer!
The following points are carried out on the chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant, if required
3. Leak test with certificate
4. Following successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Specifications and information subject to change or error!)
Dedox Hglyepfx Akgokn
Should you have any further questions, we are happy to answer them by phone.
Listing
Borken
7,009 km
Drying cabinet / heating cabinet
Thermo Scientific VötschUT 6420 300 °C
Call
Condition: excellent (used), Thermo Scientific Vötsch
Type: UT 6420
For sale is a professional laboratory and industrial drying oven / heating cabinet, Thermo Scientific / Vötsch Industrietechnik – Type UT 6420.
This unit is suitable for drying, heating, tempering, and heat treating materials and components at precisely controlled temperatures up to 300 °C.
Typical areas of application include laboratory, industry, workshop, research, electronics, and materials testing.
The stainless steel chamber ensures uniform heat distribution and is designed for continuous operation.
Chamber: Stainless steel with insertion racks
External dimensions (approx.): 170 × 70 × 80 cm (H × W × D)
Technical specifications:
Manufacturer: Thermo Scientific / Vötsch Industrietechnik
Type: UT 6420
Max. temperature: 300 °C
Temperature control: Electronic (Heraeus Kelvitron)
Rated voltage: 3/N/PE 400 V, 50/60 Hz
Rated current: 6.6 A
Power consumption: approx. 4.2 kW
Protection class: IP20
Weight: approx. 200–230 kg
Condition: used
Scope of delivery: (see photo)
(Specifications are subject to change and errors; details are non-binding!)
For further questions, we are happy to assist you by phone.
Dodpfx Aksx Hf Uaogjkn
Listing
Ireland
8,033 km
Single Rack Rotary Oven
Revent Single Rack Rotary Oven
Call
Condition: good (used), Revent Single Rack Oven
Rotary Rack Oven
Complete with one mobile oven rack
Dkodpfxjyw T D Do Akgsn
In good working condition
Listing
Dietfurt an der Altmühl
6,666 km
Temperature chamber
VötschVT 7004
Call
Year of construction: 2003, condition: used, 2 units available
Dimensions: internal 320 x 270 x 400 (h) mm
Dimensions: external 920 x 800 x 600 (h) mm
Temperature chamber approx. 35 liters
Temperature range: -70°C to +180°C
Tube port: 85 mm
Mains voltage: 230V +6/-10% 1/N 50Hz
Rated current: 10A
Rated power: 2 KW
RS232
Dkedpfx Akjxyzvdjgon
Type: VT 7004
Listing
Borken
7,016 km
Temperature test chamber
VötschVTR 7033/S
Call
Condition: good (used), Year of construction: 1996, Vötsch VTR 7033/S Temperature test chamber
Manufacturer: Vötsch
Dkjdswbpzmopfx Akgen
Type: VTR 7033/S
Item no.: 60885637
Temperature chamber
Temp. range: -70°C to +180°C
Mains voltage:400V
Rated current:24A
Rated output: 9.5 kW
Refrigerant VK: R 404 A
Refrigerant TK: R 23
Year of manufacture: 1996
TK 07
Financing through our bank is also possible.
komplett-konzept.leasingo.de
You will find further articles - new and used - in our store!
International shipping costs on request!
Listing
Borken
7,016 km
Temperature shock test chamber
VötschVT 7030 S2
Call
Condition: good (used), Year of construction: 1998, Vötsch VT 7030 S2 Temperature Shock Test Chamber -80 °C to +220 °C
The Vötsch VT 7030 S2 Environmental Test Chamber is designed for laboratory applications that require testing of materials and components in a known environment. With its versatile capabilities and easy-to-use controls, this programmable unit can be used to simulate a variety of environmental conditions for scientific studies, product testing and process control.
Data for temperature tests in single chamber operation
Hot chamber:
Temperature shock test chamber Test chamber 300 l
Temperature range +50 °C to +220 °C
Temperature deviation in time in the center of the chamber ± 1 K
Temperature deviation in space ± 2 K
Temperature gradient (according to IEC 60068-3-5) 4 K
Rate of temperature change (according to IEC 60068-3-5, measured in supply air)
Heating 11 K/min
Djdpfxowbdv Ss Akgskn
Cold chamber:
Temperature shock test chamber Test chamber 300 l
Temperature range -80 °C to +70 °C
Temperature deviation in time in the middle of the usable space ± 1 K
Temperature deviation in space 2 K
Temperature gradient (according to IEC 60068-3-5) 4 K
Rate of temperature change (according to IEC 60068-3-5, measured in supply air)
Heating 1.5 K/min
Cooling 4K/min
Technical data:
Temperature shock test chamber
Test chamber volume approx. 300 l
Voltage: 3/N/PE AC 400 V ± 10 % , 50 Hz
Rated power: 30 kW
Rated power: 50 A
Refrigerant: R-404a /R-23
Chiller: Water-cooled
Weight: approx. 940 kg
Year of construction. 1998
Test room dimensions: Width 770 mm x depth 650 mm x height 610 mm
Housing dimensions: Width 1200 mm x depth 1800 mm x height 2050 mm
TS 05
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Further items - new and used - can be found in our store!
International shipping costs on request!
Listing
Borken
7,016 km
Temperature test chamber
VötschVT 7100
Call
Condition: excellent (used), Heraeus Vötsch VT 7100 Temperature test chamber -70°C to +180°C
Heraeus Vötsch
Temperature test chamber
VT 7100
-70°C to +180°C
1035 liters
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Dkjdpfxjph Uzxo Akgen
Further articles - new and used - you will find in our store!
International shipping costs on request!
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
7,016 km
Temperature test chamber Climate test
VötschVTR 7033/S
Call
Year of construction: 1998, condition: good (used), Vötsch VTR 7033/S Temperature Test Chamber
Manufacturer: Vötsch
Type: VTR 7033/S
Item No.: 60885637
Temperature Chamber
Temp. Range: -70°C to +180°C
Dedpfx Asuuin Rjkgekn
Line Voltage: 400V
Rated Current: 24A
Rated Power: 9.5 kW
Refrigerant (VK): R 404 A
Refrigerant (TK): R 23
Year of Manufacture: 1998
TK 09
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
7,016 km
Climate test chamber Temperature test
VötschVCS 7100
Call
Condition: good (used), Vötsch VCS 7100 Climatic Test Chamber -70°C to +180°C
Manufacturer: Vötsch
Type: VCS 7100
Temp. Range: -70°C to +180°C
Line Voltage: 400 V
Rated Current: 17 A
Rated Power: 11 kW
Refrigerant: R404A
Height: 1980 mm
Width: 1350 mm
Depth: 2060 mm
Dkodpfxsuuix No Akgsn
Chamber:
Height: 900 mm
Width: 970 mm
Depth: 1400 mm
KK-05
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
7,016 km
Temperature shock test chamber -70-220°C
VötschVT 7012 S2
Call
Year of construction: 2000, operating hours: 1,04,382 h, condition: excellent (used), Vötsch Shock Test Chamber VT 7012 S2
System for extreme temperature cycling
Temperature shock testing is used to test the resistance of components, devices, and other products to rapid changes in ambient temperature.
The test specimens are subjected to rapid temperature changes in air with alternating upper and lower temperature loads.
These cyclical stresses and the accelerated aging caused by temperature changes reveal weaknesses in the test specimen.
Vertical arrangement of the test chambers
Ball screw drive for safe guidance of the car
Cart load capacity 50 kg for VT3 7012 S2
All-around grilles in the car secure the test specimens
High air circulation rate, short temperature change times, and uniform temperature distribution in the test chamber
Hot chamber can be used as a temperature storage unit, cold chamber as a temperature exchange unit
Minimal energy consumption
No compressed air required
Manufacturer: Vötsch
Type: VT 7012 S2
Type: Temperature shock test chamber
Test chamber volume: 120 l
Nominal voltage: 400 V
Nominal power: 10 kW
Nominal current: 25 A
Refrigerant: R452A
Cooling unit: Water-cooled
Shock cooling (nitrogen cooling) via customer-supplied nitrogen
External dimensions
Width: 930 mm
Depth: 2115 mm
Height: 1970 mm
Test chamber dimensions
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Protection class
Device: IP 42
Operating panel: IP 20
Dedpfsx Exmtjx Akgokn
Control cabinet: IP 54
Temperature test parameters for single-chamber operation |
Test chamber dimensions
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Protection class ...Temperatur Temperature range
Hot chamber: +50°C to +220°C
Cold chamber: -70°C to +70°C
Temperature deviation over time: ±2 K
in steady state
Temperature deviation over space: ±2 K
in steady state in the car
Heating rate, hot chamber: 11 K/min
Cooling rate, cold chamber: K/min
Heating rate, cold chamber: 2 K/min
Cooling rate, hot chamber: K/min
Observation window: 355 x 355 mm
Pipe opening: 67 mm
Year of manufacture: 2000
Operating hours: 104,382
Weight: 1000 kg
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Further items – new and used – can be found in our shop! International shipping costs on request!
Listing
Borken
7,016 km
Large-scale climate test chamber
VötschVCZ 04032
Call
Condition: good (used), Large-scale system for climate tests with S!MCON control
Design
The system consists of the following main components:
- Walk-in, insulated test room
- Air treatment room
- Machine unit
- Air conditioning system
- Control cabinet
Test room
The fixtures in the test room are made of corrosion-resistant material.
The test room can be illuminated, is walk-in, and has a condensate and cleaning drain.
Air treatment room
The air treatment room is located behind the air baffle in the insulated interior.
It contains the following components necessary for temperature control and is accessible via easily removable panels.
- Test room fans
- Heat exchangers
- Electric heaters
- Ventilation and exhaust system
- Temperature sensors
In the air treatment room, the air is tempered (cooled/heated), humidified and dehumidified, and circulated by fans.
The air is drawn in under the ceiling and expelled at floor level.
Sensors
The temperature and humidity sensors are located behind the air baffle in the air treatment room.
Machine Unit
The machine unit, consisting of refrigeration units, supplies the air treatment room with the required energy.
Climate System
The climate system consists of:
- Steam humidifier
- Dehumidification evaporator
Technical Data
Test chamber volume: approx. 32 m³
Direct temperature range: -40 to +100°C
Temperature fluctuation over time in the center of the usable space: +/- 0.5 to +/- 1
Temperature change rate
Heating: from -35°C to +50°C at 3 K/min
Cooling: from +85°C to +85°C at 2 K/min
from +80°C to -40°C at 1 K/min
Data for climate testing
Temperature range: 10 to 95°C
Humidity range: 10 to 95% RH
Dew point range: 5 to 93°C
Dodpfx Akew U Sv Eegjkn
Temperature fluctuation: +/- 5°C
Humidity fluctuation: +/- 3 to +/- 5% RH
Cooling water specifications
Connections
Inlet: 2 x 1 1/2" RH
Return: 2 x 1 1/2" RH
Consumption at full load: max. 16 m³/h
Maximum load on the test chamber floor: 10,000 N/m²
Nominal voltage: 3/N / PE AC 400 V 50 Hz
Nominal power: 97 kW
Nominal current: 148 A
Dimensions:
Test chamber: Width 3.60 m, Height 2.20 m, Depth 5 m
Climate chamber divided for transport at a specified location (approx. 2.50 m).
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items – new and used – in our shop!
International shipping costs on request!
We make it easier for you to find: "vötsch oven"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you