Used Weiss Temperature Shock Test Chamber for sale (17,925)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
7,009 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), Weiss Temperature Shock Test Chamber
Here we offer a temperature shock test chamber.
Weiss Temperature Shock Test Chamber, Water-Cooled
Specification:
Temperature range, hot chamber: +60°C … +220°C
Temperature range, cold chamber: -10°C … -80°C
Hot/cold chamber switching time: 10 sec.
Temperature stability: ±1 K
Dimensions and other data:
External dimensions: Height 1990 mm
Isdjzd Ulgepfx Anvsau
Width (without and with door hinge): without… approx. 1820 mm, with… approx. 1850 mm
Depth (without and with test chamber door): without… approx. 900 mm, with… approx. 1155 mm
Dimensions of the lifting platform (test chamber): Height 450 mm, Width 500 mm, Depth 600 mm
Volume: 130 liters
Test chamber load: max. 20 kg
Load on the test chamber floor: max. 20 kg
Cooling water pressure: min. 2 ... max. 6 bar
Max. fuse rating: 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of the device: approx. 65 dB(A)
Refrigeration cascade, water-cooled
Connection values: 3/N/PE/AC 400V ±10% 50Hz / 14.0 kW
Rated current: 26.0 A
Refrigerant: R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), Weiss Temperature Shock Test Chamber
Here we offer a temperature shock test chamber.
Weiss Temperature Shock Test Chamber, Water-Cooled
Specifications:
Temperature range, hot chamber: +60°C … +220°C
Temperature range, cold chamber: -10°C … -80°C
Switching time, hot/cold chamber: 10 s
Temperature stability: ±1 K
Dimensions and other data:
External dimensions: Height 1990 mm
Width (without and with door hinge): without... approx. 1820 mm, with... approx. 1850 mm
Depth (without and with test chamber door): without... approx. 900 mm, with... approx. 1155 mm
Dimensions of the lifting platform (test chamber): Height 450 mm, Width 500 mm, Depth 600 mm
Volume: 130 liters
Test chamber load: max. 20 kg
Load on the test chamber floor: max. 20 kg
Cooling water pressure: min. 2 ... max. 6 bar
Max. fuse rating: 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of the device: approx. 65 dB(A)
Refrigeration cascade, water-cooled
Connection values: 3/N/PE/AC 400V ±10% 50Hz /18.7 kW
Rated current: 26.0 A
Iaodpfxozd Sfds Anveu
Refrigerant: R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Temperature shock test chamber
Weiss130 Liter TS 130 *
Call
Condition: excellent (used), Here we offer you a temperature shock testing chamber.
Weiss temperature shock testing chamber, air-cooled
Specification:
Temperature range, warm chamber: +60°C … +220°C
Temperature range, cold chamber: -10°C … -80°C
Changeover time, warm/cold chamber: 10 s
Temperature stability: ±1 K
Dimensions and other data:
External dimensions: height 1990 mm
Width (without and with door hinge): without… approx. 1820 mm, with… approx. 1850 mm
Depth (without and with test chamber door): without… approx. 900 mm, with… approx. 1155 mm
Dimensions of the lifting platform (test chamber): height 450 mm, width 500 mm, depth 600 mm
Volume: 130 liters
Test chamber load: max. 20 kg
Load on the test chamber floor: max. 20 kg
Cooling water pressure: min. 2 ... max. 6 bar
Max. fuse rating: 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of the device: approx. 65 dB(A)
Refrigeration cascade, water-cooled
Connection values: 3/N/PE/AC 400V ±10% 50Hz /14.0 kW
Rated current: 26.0 A
Refrigerant: R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used
Iedpszd Sd Hofx Anveau
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have over the phone.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Borken
7,009 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), Weiss Temperature Shock Test Chamber
Here we offer you a temperature shock test chamber.
Weiss Temperature Shock Test Chamber, Air-Cooled
(Compressor has been replaced!)
Specifications:
Temperature range, hot chamber: +60°C … +220°C
Temperature range, cold chamber: -10°C … -80°C
Hot/cold chamber switching time: 10 s
Temperature stability: ±1 K
Dimensions and other data:
External dimensions: Height 1990 mm
Width (without and with swivel arm): without... approx. 1820 mm, with... approx. 1915 mm
Depth (without and with test chamber door): without... approx. 900 mm, with... approx. 1155 mm
Isdpfszd Sdysx Anvsau
Dimensions of the lifting platform (test chamber): Height 450 mm, Width 500 mm, Depth 600 mm
Volume: 130 liters
Test chamber load: max. 20 kg
Load on the test chamber floor: max. 20 kg
Cooling water pressure: min. 2 ... max. 6 bar
Max. fuse rating: 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of the device: approx. 65 dB(A)
Connection values: 3/N/PE/AC 400V ±10% 50Hz / 14.0 kW
Rated current: 26.0 A
Refrigerant: R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by phone.
Listing
Borken
7,009 km
Temperature shock test chamber
CTSTSS-70/32 -80°C bis +200°C
Call
Condition: excellent (used), CTS Temperature Shock Test Chamber
Type: TSS-70/32
Manufacturer: CTS Klima Temperatur Systeme
Design: Air-cooled
For sale is a CTS temperature shock test chamber for temperature change and shock testing in industry, research, and development.
Technical data:
Test chamber volume: approx. 32 liters
Max. test specimen weight: approx. 10 kg
Temperature ranges:
Hot chamber: +50 °C to +200 °C
Cold chamber: -80 °C to +100 °C
Performance data:
Heating rate: approx. 6 K/min
Cooling rate: approx. 6 K/min
Temperature change rate: up to approx. 100 K/min
Changeover time: < 10 seconds
Temperature deviation: ±1 K / ±2 K
Electrical data:
Connection: 400 V / 3/N / 50 Hz
Rated power: approx. 9.7 kW
Rated current: approx. 15.4 A
Fuse: 16 A slow-blow
Protection class: IP 22
Refrigerant:
R404A: 2.3 kg / R23: 0.90 kg
Pressure data:
Operating overpressure: 25 bar
Test pressure: 27.5 bar
Dimensions: approx. 1325 x 2012 x 1820–2020 mm (W x D x H)
Weight: approx. 650 kg
Further data:
Sound pressure level: < 58 dB(A)
Compressed air connection: 1/4" male
Equipment:
Two-chamber system (hot / cold chamber)
Iaedpfx Anoy I Ntcsvju
Digital CTS control
Display / control panel
Program operation
Operating hour counter
Observation window
Interior lighting
Temperature limiter
Test specimen protection
RS232 interface
Documentation:
Declaration of conformity available
Test certificates available
Operating manual available
Wiring diagram available
Piping diagram available
Quick start guide available
Safety data sheets available
Note:
The table shown in the photos is not included in the sale.
Condition:
Used
Optical condition see pictures
Scope of supply as shown in the pictures
Inspection possible by appointment.
Loading can be organized.
Commercial sale
(Changes and errors in the technical data and information are reserved!)
We will be happy to answer any further questions you may have by telephone.
Listing
Borken
7,009 km
Temperature shock test chamber
especTSD-100
Call
Condition: used, Espec
Type: TSD-100
100 liters usable chamber volume for larger test specimens up to 30 kg.
Compliant with all common international standards.
Water-cooled
Temperature range hot chamber: +60°C to +200°C
Temperature range cold chamber: -70°C to 0°C
Test chamber interior dimensions: 710 x 345 x 410 mm (W x H x D)
Isdpfx Anjxugq Aoveau
External dimensions: 1100 x 1885 x 1965 mm (W x H x D)
Water-cooled refrigeration unit
Programmable control via touch panel
Automatic defrosting
Overtemperature protection
Operating hours counter
Mobile design (on castors)
2 stainless steel specimen baskets
Cable entry port ⌀ 100 mm
Refrigerants: 3 kg R404A, 1 kg R23
Power supply: 400V 3Ph 50Hz
Max. current consumption: 32A
Condition: used
Weight: 1100 kg
Important safety information for buyers:
The following procedures are performed on all chambers offered by us prior to sale:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. Upon passing inspection, chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Subject to modifications and errors in technical data and specifications!)
For further questions, please feel free to contact us by phone.
Listing
Borken
7,009 km
Temperature shock test chamber
EspecTSD-100 -70 °C bis +200 °C
Call
Condition: excellent (used), Here we offer a temperature shock test chamber.
with 100 liters of usable space for larger test specimens up to 30 kg.
Compliant with all current international standards.
Iedpen Smtmofx Anveau
Water cooled
Temperature range hot chamber: +60 °C to +200 °C
Temperature range cold chamber: -70 °C to 0 °C
Test chamber dimensions: 710 x 345 x 410 (W x H x D) in mm
External dimensions: 1100 x 1885 x 1965 (W x H x D) in mm
Water-cooled refrigeration unit
Program control via touch panel
Automatic defrost
Overtemperature protection
Operating hours counter
Mobile version
2 test material baskets made of stainless steel
Cable gland Ø 100 mm
Refrigerant: 3 kg R404A 1kg R23
Power supply: 400V 3Ph 50Hz
Max. Current consumption: 32A
Type: TSD-100
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,009 km
Temperature shock test chamber
EspecTSD-100
Call
Condition: good (used), Espec
Type: TSD-100
100 liters of usable space for larger test specimens up to 30 kg.
Complies with all current international standards.
Water-cooled
Temperature range hot chamber: +60 °C to +200 °C
Temperature range cold chamber: 0 °C to -70 °C
Test chamber dimensions: 710 x 345 x 410 (W x H x D) in mm
External dimensions: 1100 x 1885 x 1965 (W x H x D) in mm
Water-cooled refrigeration unit
Program control via touch panel
Iaodjugl H Sopfx Anvou
Automatic defrosting
Overtemperature protection
Operating hours counter
Mobile version
2 stainless steel test baskets
Cable gland Ø 100 mm
Refrigerant: R404A 1kg R23
Power supply: 400V 3Ph 50Hz
Max. Current consumption: 32A
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Temperature shock test chamber
WeissTS 130
Call
Condition: used, White
Type: TS 130
Temperature shock test chamber water-cooled
Specification:
Temperature range hot chamber +60°C … +220°C
Temperature range cold chamber -10°C … -80°C
Switch between hot and cold chambers 10 sec.
Temperature stability ±1 K
Dimensions and other data:
External dimensions: Height 1990 mm
Width (without and with door hinge) without....approx. 1820 mm with....approx. 1850 mm
Iaodpfjvwckhex Anvju
Depth (without and with test chamber door) without....approx. 900 mm with....approx. 1155 mm
Dimensions of the lifting basket (test room) height 450 mm, width 500 mm, depth 600 mm
Volume 130 liters
Test room load max. 20 kg
Test room floor load max. 20 kg
Cooling water pressure min. 2 ... max. 6 bar
Max. fuse 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of the device approx. 65 dB(A)
Water-cooled cooling cascade
Connection values: 3/N/PE/AC 400V ±10% 50Hz /14.0 kW
Rated current 26.0 A
Refrigerant R 404A / R23
Weight: approx. 950 kg
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
More We will be happy to answer any questions you may have over the phone.
Listing
Borken
7,009 km
Temperature shock test chamber 60 liters
WeissTS 60 -72…+220 °C
Call
Condition: excellent (used), Weiss Technik TS 60 Thermal Shock Test Chamber / 60 L, –71…+220 °C
Water-cooled
Item description:
For sale is a Weiss Technik TS 60 Thermal Shock Test Chamber.
The chamber is ideally suited for rapid temperature cycling tests (e.g., per IEC, MIL-STD, JEDEC) and has been well maintained.
Volume & internal dimensions:
Test volume: 60 liters
Internal basket/test room dimensions (W × D × H): approx. 380 × 430 × 370 mm
External dimensions (W × D × H): 895 × 1970 × 1895 mm
Temperature ranges & cycling:
Hot chamber: +50 °C to +220 °C
Cold chamber: –72 °C to +70 °C
Isdpfx Asxr A R Tenvoau
Transfer time (basket between both zones): < 10 seconds
Heating rate / speed up to 17 °C/min
Cooling rate / speed up to 3.7 °C/min
In single mode (cold zone only), heating rate: approx. 3.2 °C/min
Temperature deviation & uniformity:
Temporal deviation (temperature control over time): ± 0.3 to ± 1.0 °C
Load / permissible weight & lifting system:
Basket/lifting system load capacity: 20 kg maximum load
Transfer basket secured by safety grilles on all sides
Additional features & equipment:
Noise level: approx. 58 dB(A) in operation
Control: Touchscreen, RS-232 / USB / Ethernet interfaces
Electrical connection:
3/N/PE AC 400 V ±10% 50 Hz
Rated power: approx. 8.5 kW
Rated current: approx. 25 A
On-site protection: 32 A
Refrigerants: R-404A / R-23
Weight: 800 kg
Important safety information for buyers!
The following steps are carried out on our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and errors reserved!)
For further questions, feel free to contact us by phone.
Listing
Borken
7,016 km
Temperature shock test chamber
VötschVT 7030 S2
Call
Condition: good (used), Year of construction: 1998, Vötsch VT 7030 S2 Temperature Shock Test Chamber -80 °C to +220 °C
The Vötsch VT 7030 S2 Environmental Test Chamber is designed for laboratory applications that require testing of materials and components in a known environment. With its versatile capabilities and easy-to-use controls, this programmable unit can be used to simulate a variety of environmental conditions for scientific studies, product testing and process control.
Data for temperature tests in single chamber operation
Hot chamber:
Temperature shock test chamber Test chamber 300 l
Temperature range +50 °C to +220 °C
Temperature deviation in time in the center of the chamber ± 1 K
Temperature deviation in space ± 2 K
Temperature gradient (according to IEC 60068-3-5) 4 K
Rate of temperature change (according to IEC 60068-3-5, measured in supply air)
Iaedowbdv Sepfx Anvsu
Heating 11 K/min
Cold chamber:
Temperature shock test chamber Test chamber 300 l
Temperature range -80 °C to +70 °C
Temperature deviation in time in the middle of the usable space ± 1 K
Temperature deviation in space 2 K
Temperature gradient (according to IEC 60068-3-5) 4 K
Rate of temperature change (according to IEC 60068-3-5, measured in supply air)
Heating 1.5 K/min
Cooling 4K/min
Technical data:
Temperature shock test chamber
Test chamber volume approx. 300 l
Voltage: 3/N/PE AC 400 V ± 10 % , 50 Hz
Rated power: 30 kW
Rated power: 50 A
Refrigerant: R-404a /R-23
Chiller: Water-cooled
Weight: approx. 940 kg
Year of construction. 1998
Test room dimensions: Width 770 mm x depth 650 mm x height 610 mm
Housing dimensions: Width 1200 mm x depth 1800 mm x height 2050 mm
TS 05
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Further items - new and used - can be found in our store!
International shipping costs on request!
Listing
Borken
7,016 km
Temperature shock test chamber -70-220°C
VötschVT 7012 S2
Call
Year of construction: 2000, operating hours: 1,04,382 h, condition: excellent (used), Vötsch Shock Test Chamber VT 7012 S2
System for extreme temperature cycling
Temperature shock testing is used to test the resistance of components, devices, and other products to rapid changes in ambient temperature.
The test specimens are subjected to rapid temperature changes in air with alternating upper and lower temperature loads.
These cyclical stresses and the accelerated aging caused by temperature changes reveal weaknesses in the test specimen.
Vertical arrangement of the test chambers
Ball screw drive for safe guidance of the car
Cart load capacity 50 kg for VT3 7012 S2
All-around grilles in the car secure the test specimens
High air circulation rate, short temperature change times, and uniform temperature distribution in the test chamber
Hot chamber can be used as a temperature storage unit, cold chamber as a temperature exchange unit
Minimal energy consumption
No compressed air required
Manufacturer: Vötsch
Type: VT 7012 S2
Type: Temperature shock test chamber
Test chamber volume: 120 l
Nominal voltage: 400 V
Nominal power: 10 kW
Nominal current: 25 A
Refrigerant: R452A
Cooling unit: Water-cooled
Shock cooling (nitrogen cooling) via customer-supplied nitrogen
External dimensions
Width: 930 mm
Depth: 2115 mm
Height: 1970 mm
Test chamber dimensions
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Protection class
Device: IP 42
Operating panel: IP 20
Control cabinet: IP 54
Temperature test parameters for single-chamber operation |
Test chamber dimensions
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Protection class ...Temperatur Temperature range
Hot chamber: +50°C to +220°C
Cold chamber: -70°C to +70°C
Temperature deviation over time: ±2 K
in steady state
Temperature deviation over space: ±2 K
Isdpfex Exmtjx Anveau
in steady state in the car
Heating rate, hot chamber: 11 K/min
Cooling rate, cold chamber: K/min
Heating rate, cold chamber: 2 K/min
Cooling rate, hot chamber: K/min
Observation window: 355 x 355 mm
Pipe opening: 67 mm
Year of manufacture: 2000
Operating hours: 104,382
Weight: 1000 kg
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Further items – new and used – can be found in our shop! International shipping costs on request!
Listing
Borken
7,009 km
Shock test chamber
VötschVT 7012 S3
Call
Condition: excellent (used), Vötsch Shock Test Chamber
Here we offer you a Vötsch shock test chamber.
Water-cooled
Temperature range: -80°C to +220°C
Warm chamber: +50 to +220
Intermediate chamber: -10 to +90
Cold chamber: -80 to +70
Supply voltage: 400V ±10% 3/N 50Hz
Rated current: 30.5 A
Rated power: 13.5 kW
Refrigerant VK: R 404A 3.00 kg p*: 25 bar
Refrigerant TK: R23 15 bar p*: 25 bar
Condition: used
Type: VT 7012 S3
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
Iedjzd Uzuspfx Anvoau
We would be happy to answer any further questions you may have by phone.
Listing
Borken
7,009 km
Temperature test chamber -20°C...+140°C
TIRATTRE 2001 S
Call
Condition: excellent (used), Here we offer a TIRA temperature testing chamber.
TIRA temperature testing chamber, air-cooled.
The chamber has the option for an external test box, including an external sensor connection, and can therefore also be used as an external temperature control unit.
Temperature range: -20°C to +140°C
Temperature stability over time: ±0.1°C to ±0.3°C
External dimensions: Width 860 mm x Depth 1500 mm x Height 2100 mm
Test chamber dimensions: Width 601 mm x Depth 545 mm x Height 692 mm
Electrical connection: 400V +6% / -10% 50Hz 3P+N+PE
Rated current: 10.0 (max. 17) A
Ijdpfx Aszd Umqsnvjau
Rated power: 5.2 (max. 9.0) kW
Net weight: 735 kg
Refrigerant: R404A / R23
Type: TTRE 2001S
For your safety as a buyer, please note the following information:
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We would be happy to answer any further questions you may have by phone.
Listing
Borken
7,009 km
Temperature test chamber
Heraeus VötschVTS 7033
Call
Condition: excellent (used), Heraeus Vötsch Temperature Test Chamber
Here we offer a Heraeus Vötsch temperature test chamber.
Vötsch Temperature Test Chamber VTS 7033, Water-Cooled
Temperature range: -70°C to +180°C
Temporal temperature deviation: ± 0.5 K
Isdpfx Aezd Sf Donvjau
Spatial temperature deviation: ± 1.5 K
Heating rate: 7.5 K/min
Cooling rate: 6.5 K/min
Test chamber dimensions: Width 825 mm x Depth 800 mm x Height 870 mm
Housing dimensions: 1080 mm x 1710 mm x 1950 mm
Side openings: 12 cm and 13 cm
Voltage: 400V +6/-10%, 3/N, 50Hz
Rated power: 9.5 kW, Rated current: 22 A
Refrigerant: R404A / R23
Approx. 570 liters, Weight: 580 kg
For your safety as a buyer, please note the following information:
The following steps are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Type: VTS 7033
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Temperature test chamber
RS-SimulatorenTS 150/75
Call
Condition: excellent (used), RS Simulators
Here we offer a temperature test chamber.
Temperature Test Chamber, Water-Cooled
Temperature range: -70°C to +180°C
Time deviation: ±1 K according to DIN 50011 in an empty test chamber
Average heating time: approx. 3 K/min (according to DIN 50011 Part 12)
Average cooling time: approx. 3 K/min (according to DIN 50011 Part 12)
Test chamber dimensions: Width 530 mm x Height 530 mm x Depth 530 mm
External dimensions: Width approx. 900 mm x Height approx. 1800 mm x Depth approx. 1400 mm
Total power: approx. 6 kVA
Current consumption: 12 A
Main fuse: 3 x 16 A, slow-blow
Connection voltage: 3x400V/N/PE 50Hz
Weight: approx. 600 kg
Type: TS 150/75
Refrigerant: R404A / R23
Iasdpfjzd Sfqox Anvou
Condition: used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data and specifications!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Shock test chamber
HeraeusHT 7012 S2
Call
Condition: excellent (used), Here, we offer a shock test chamber.
Water-cooled temperature shock test chamber
Two-chamber design
Warm chamber:
Temperature control in the warm chamber ranges from +50°C to +220°C
Temporal temperature deviation in the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate:
Heating: 11 K/min
Cold chamber:
Temperature control in the cold chamber ranges from -65°C to +70°C
Temporal temperature deviation in the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate:
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Temperature range, warm chamber: +50°C to +220°C
Temperature range, cold chamber: -65°C to +70°C
Test chamber dimensions: Width 470mm, Depth 650mm, Height 410mm
External dimensions: Width 930mm, Depth 2115mm, Height 1970+mm
Rated power: 10 kW
Rated current: 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant: R404A / R23
Operating hours: 27,903 hours
Weight: 1000 kg
For your safety as a buyer, please note the following information:
Iasdpfjzd R Uwsx Anvju
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated instruments.
Type: HT 7012 S2
Condition: used
Scope of supply: (See image)
(Changes and errors in the technical data are subject to change!)
We are happy to answer any further questions you may have by phone.
Listing
Borken
7,009 km
Temperature test chamber 335 liters
VötschVTS 7034-5 -70°C bis +180°C
Call
Condition: excellent (used), Heraeus Vötsch Temperature Test Chamber
Iaedpszd R Tgsfx Anvsu
Here we offer you a Heraeus Vötsch temperature test chamber.
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
Temperature range: -70°C to +180°C
Temperature deviation (temporal): ±0.1 to ±0.5 K
Temperature deviation (spatial): ±0.5 to ±2.0 K
Temperature change rate (cooling): 5.0 K/min
Temperature change rate (heating): 6.5 K/min
Heat compensation at +20°C: 3000 W
Heat compensation at -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Test chamber volume: 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW, Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Side feedthrough: 5.5 cm / 12.5 cm
Chamber is water-cooled
Refrigerant: R 452A and R 23
Weight: approx. 570 kg
Type: VTS 7034-5
For your security as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Temperature test chamber
WEISSWT1-600/70
Call
Condition: excellent (used), Weiss Temperature Test Chamber
Here we offer you a Weiss temperature test chamber.
Weiss Temperature Test Chamber, Water-Cooled
Technical Data:
Test chamber designation: WT1-600/70
External dimensions without hinges and door closure
Height 1980 mm, Width 1085 mm, Depth 1655 mm
Iasdpfx Ajzd R Svenvou
Internal dimensions
Height 950mm, Width 800mm, Depth 800mm
Test chamber volume: approx. 600 liters
Cold/heat operation: -70 to 180°C
Temperature change per unit of time
Cooling: approx. 2.5 K/min
Heating: approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 9.1 kW
Rated current: 19 A
Permissible weight of test specimens
Total load of the shelf supports: 80 kg
Refrigerant: R 404A + R23
Weight: 600 kg
Type: WT1-600/70
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Temperature test chamber
WEISSWT-600/70
Call
Condition: excellent (used), Weiss Temperature Test Chamber
Here we offer a temperature test chamber.
Weiss Temperature Test Chamber, Water-Cooled
Technical Data:
Test chamber designation: WT-600/70
External dimensions with hinges and door lock:
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock:
Height 1995 mm, Width 1000 mm, Depth 1660 mm
Internal dimensions:
Height 950 mm, Width 800 mm, Depth 800 mm
Test chamber volume: approx. 600 liters
Iaedpfxszd R Drs Anveu
Cold / heat operation: -70°C to 180°C
Temperature change per unit of time:
Cooling down: approx. 2.5 K/min
Heating up: approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 9.1 kW
Rated current: 19 A
Fuse (customer-supplied): 32 A slow-blow
Permissible weight of test specimen:
Total load of the shelf supports: 80 kg
Test chamber floor: 80 kg, insert shelf: 40 kg
Refrigerant: R 404A/R23
Weight: 675 kg
Type: WT-600/70
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and information are subject to change!)
We are happy to answer any further questions you may have by phone.
Listing
Borken
7,009 km
Shock test chamber
HeraeusHT 7012 S2
Call
Condition: excellent (used), Heraeus Shock Test Chamber
We offer a shock test chamber here.
Temperature shock test cabinet, water-cooled
Two-chamber design
Warm chamber:
The temperature control of the warm chamber ranges from +50°C to +220°C
Temporal temperature deviation in the center of the usable space ± 1 K
Spatial temperature deviation ± 2 K
Temperature change rate
Heating 11 K/min
Cold chamber:
The temperature control of the cold chamber ranges from -65°C to +70°C
Temporal temperature deviation in the center of the usable space ± 1 K
Spatial temperature deviation ± 2 K
Temperature change rate
Heating 2 K/min
Cooling 3 K/min
Test chamber volume 125 liters
Temperature range, warm chamber +50°C to +220°C
Temperature range, cold chamber -80°C to +70°C
Test chamber dimensions: width 470mm, depth 650mm, height 410mm
External dimensions: width 930mm, depth 2115mm, height 1970+mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant R404A / R23
Weight: 1000 kg
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Type: HT 7012 S2
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications are reserved!)
We will be happy to answer any further questions you may have by phone.
Iaedpfjzd R Azjx Anvou
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
7,009 km
Temperature test chamber, explosion-proof
CTST-30/950 Ex/I
Call
Year of construction: 2011, condition: excellent (used), CTS
Type: T-30/950 Ex/I
CTS Temperature Test Chamber, Explosion-Proof
Control – 32-bit controller
LCD control panel
Digital display for set and actual values
Numerical input of set values
Error messages in plain text
RS 232 interface
Free switching channels for product-side test specimen activation
Temperature Testing:
Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
Heating: 2 K/min
Cooling: 1.5 K/min down to -10°C
Thermal radiation: approx. 1000 W at +20°C
approx. 200 W at -25°C
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with a large flow rate of N2 until the
o2 content drops below 3%. Then, it switches to a base flow amount (approx. 10% of the large flow rate).
The nitrogen flow for the base amount is measured and displayed using a flowmeter and monitored via a limit switch.
O2 monitoring continuously extracts gas from the test chamber via a flame arrestor and passes it over an O2 sensor which checks the residual oxygen content of the extracted air.
Afterwards, the gas is returned to the test chamber via a second flame arrestor.
The extraction pump is monitored by a volumetric flow meter. Additional details can be found in the Dräger user manual in the appendix.
The gas system is currently deactivated!
All technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without irradiation, and without additional equipment.
Dimensions:
Test chamber volume: 950 liters
Test chamber dimensions: Height approx. 700 mm / Width approx. 900 mm / Depth approx. 1500 mm
External dimensions: Height approx. 2400 mm / Width approx. 1270 mm / Depth approx. 3125 mm
Operating data:
Electrical connection: 400V +6/-10 %, 3/N, 50 Hz
Nominal power: 21.6 kW
Rated current: 36.5 A
Protection class: IP 54
Iasdpszd Rzwefx Anveu
Condensate drain: non-pressurized, R 1/2" inner thread
Sound pressure level:
Listing
Borken
7,009 km
Shock test chamber -80°C to +220°C
VötschVT 7012 S2
Call
Condition: excellent (used), Here, we offer a Vötsch shock test chamber.
Temperature shock test cabinet, water-cooled
Two-chamber design
Warm chamber:
The temperature control of the warm chamber ranges from +50°C to +220°C
Iasdpfszd Rzkox Anvsu
Temporal temperature deviation in the center of the usable space ± 1 K
Spatial temperature deviation ± 2 K
Temperature change rate
Heating 11 K/min
Cold chamber:
The temperature range of the cold chamber is from -80°C to +70°C
Temporal temperature deviation in the center of the usable space ± 1 K
Spatial temperature deviation ± 2 K
Temperature change rate
Heating 2 K/min
Cooling 3 K/min
Test chamber volume 125 liters
Temperature range, warm chamber +50°C to +220°C
Temperature range, cold chamber -80°C to +70°C
Test chamber dimensions: width 470mm, depth 650mm, height 410mm
External dimensions: width 930mm, depth 2115mm, height 1970+mm
Feedthrough ∅ 67mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant R404A / R23
Weight: 1000 kg
For your safety as a buyer, please note the following information:
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a test run, which will be monitored with calibrated devices.
Type: VT 7012 S2
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We will gladly answer any further questions you may have by phone.
Listing
Borken
7,009 km
Temperature test chamber 335 liters
Vötsch-70°C bis +180°C VTS 7034-5
Call
Condition: excellent (used), Type: VCS 7034-5
Climate Test Chamber Water-Cooled
Test chamber volume: 335 liters
Performance for temperature tests:
Temperature range: -70 to +180°C
Temperature deviation over time: ±0.1 to ±0.5 K
Temperature deviation spatially: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 3.5 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3,000 W / at -20°C: 3,000 W
Temperature calibration points: +23°C and +80°C
Isdpfxjxufypj Anvjau
Performance for climate tests:
Temperature range: +10 to +95°C
Temperature deviation over time: ±0.1 to ±0.3 K
Temperature deviation spatially: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Humidity deviation over time: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climatic calibration points: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions:
Width: 580 mm, Depth: 765 mm, Height: 750 mm
External dimensions:
Width: 870 mm, Depth: 1595 mm, Height: 1775 mm
Feedthroughs:
1 x approx. 50 mm Ø, left side
2 x approx. 125 mm Ø, left side
1 x approx. 125 mm Ø, right side
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerant: R404A / R-23
For your security as a buyer, please note the following information:
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical data are subject to change and errors!)
If you have further questions, we are happy to answer them by phone.
Listing
Borken
7,009 km
Temperature test chamber 190 L
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
Call
Condition: excellent (used), Here we offer you a Heraeus Vötsch temperature testing chamber.
Heraeus Vötsch temperature testing chamber, water-cooled
Temperature range: -70°C to +180°C
Temperature deviation (time-related): ±0.1 to ±0.5 K
Temperature deviation (spatial): ±0.5 to ±2.0 K
Temperature change rate (cooling): 7.5 K/min
Temperature change rate (heating): 7.5 K/min
Thermal compensation +20°C: 3000 W
Thermal compensation -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 450 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1280 mm, Height 1575 mm
Observation window:
Width 300 mm x Height 540 mm
Test chamber volume: 190 liters
Rated voltage: 3/N/PE AC, 400 V ±10 %, 50 Hz
Rated power: 10.5 kW, Rated current: 22 A
Fuse, on customer side: 32 A, slow-blow
Iaedpfxszdtdhs Anvsu
Sound pressure level at 1 m distance (free-field measurement): < 69 dB(A)
Side access: 50 cm / 125 cm
Chamber is water-cooled
Refrigerant: R 404A and R 23
Weight: approx. 460 kg
Type: VTS 7018-5
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. Refilling with refrigerants that comply with legal regulations
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
We make it easier for you to find: "weiss temperature shock test chamber"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month



































































































































































































































