Description
We have a 2000 KVA container generator for sale.
Optionally 400/230 V (50 Hz)
or 10 kV (+/- 5%) (50 Hz)
Fully installed in two soundproof 40' HC containers.
Suitable and intended for multi-layer installation.
Dimensions: (L x W x H) 12020 x 2500 x 5800 mm
Weight: approx. 33 t + 11 t
Engine: MTU 16v396 TB 34D
Generator: A.v. Kaick DIDBN 130/125 h/4
2000 KVA Generator
Engine and generator completely mounted on a base frame and connected via a flexible coupling.
Cooling system:
Separate table cooler installed as a dual-circuit cooler in the upper container, including temperature control, connecting lines (stainless steel cooling water lines with shut-off valves for each line), circulation pumps, control valves, etc. for safe operation.
Tank system:
4000-liter tank system installed in the upper container, including system-specific accessories and complete piping.
Crodpjwa Tg Defx Abcjh
Air supply and exhaust system:
Soundproof baffles within the air supply and exhaust chambers in the container.
Air supply and exhaust openings each equipped with appropriate weather protection grilles, motor-operated blinds in the container that open automatically when the generator is in operation.
Exhaust system:
Insulated exhaust ducts within the container lead vertically from the container via silencers through the upper container, discharging the exhaust gases through the container roof.
Switchgear:
Medium/low-voltage switchgear for fully automatic emergency power operation!!!
Optionally 400/230 V or 10 kV (+/-5%)
Fully automatic machine monitoring with control for power failure detection, automatic start-up, and emergency power takeover. Upon power recovery, the system automatically switches back to the mains supply.
In the low-voltage range, parallel operation with the mains/resynchronization is possible.
Control for external mains switch - optionally 10 kV or 400/230 V
Low-voltage switchgear equipped with: 3200 A generator switch (400/230 V)
Medium-voltage switchgear equipped with: 115 A generator switch (10 kV)
Technical data of the type-tested medium-voltage switchgear
Panel type: ZS8
Rated voltage: 12 kV
Operating voltage: 10 kV
etc.
The listing was translated automatically. Translation errors are possible.
Optionally 400/230 V (50 Hz)
or 10 kV (+/- 5%) (50 Hz)
Fully installed in two soundproof 40' HC containers.
Suitable and intended for multi-layer installation.
Dimensions: (L x W x H) 12020 x 2500 x 5800 mm
Weight: approx. 33 t + 11 t
Engine: MTU 16v396 TB 34D
Generator: A.v. Kaick DIDBN 130/125 h/4
2000 KVA Generator
Engine and generator completely mounted on a base frame and connected via a flexible coupling.
Cooling system:
Separate table cooler installed as a dual-circuit cooler in the upper container, including temperature control, connecting lines (stainless steel cooling water lines with shut-off valves for each line), circulation pumps, control valves, etc. for safe operation.
Tank system:
4000-liter tank system installed in the upper container, including system-specific accessories and complete piping.
Crodpjwa Tg Defx Abcjh
Air supply and exhaust system:
Soundproof baffles within the air supply and exhaust chambers in the container.
Air supply and exhaust openings each equipped with appropriate weather protection grilles, motor-operated blinds in the container that open automatically when the generator is in operation.
Exhaust system:
Insulated exhaust ducts within the container lead vertically from the container via silencers through the upper container, discharging the exhaust gases through the container roof.
Switchgear:
Medium/low-voltage switchgear for fully automatic emergency power operation!!!
Optionally 400/230 V or 10 kV (+/-5%)
Fully automatic machine monitoring with control for power failure detection, automatic start-up, and emergency power takeover. Upon power recovery, the system automatically switches back to the mains supply.
In the low-voltage range, parallel operation with the mains/resynchronization is possible.
Control for external mains switch - optionally 10 kV or 400/230 V
Low-voltage switchgear equipped with: 3200 A generator switch (400/230 V)
Medium-voltage switchgear equipped with: 115 A generator switch (10 kV)
Technical data of the type-tested medium-voltage switchgear
Panel type: ZS8
Rated voltage: 12 kV
Operating voltage: 10 kV