BDVA-HV 1000-10Ruhstrat
Transformator
BDVA-HV 1000-10
Ruhstrat
Transformator
ONO plus VAT
€20,000
Year of construction
2025
Condition
New
Location
Leuna 

Show images
Show map
Machine data
- Machine type:
- BDVA-HV 1000-10
- Manufacturer:
- Ruhstrat
- Model:
- Transformator
- Machine number:
- 0400-01-0010000
- Year of construction:
- 2025
- Condition:
- new
- Functionality:
- fully functional
Price & Location
ONO plus VAT
€20,000
- Location:
- Leuna, Germany
Call
Technical details
- Type of input current:
- AC
- Overall weight:
- 2,750 kg
- Input voltage:
- 10,000 V
- Input frequency:
- 50 Hz
- Total height:
- 1,953 mm
- Total width:
- 1,000 mm
- Total length:
- 1,600 mm
- Warranty duration:
- 72 months
- Nominal power (apparent):
- 1,000 kVA
- Nominal power:
- 1,000 kW (1,359.62 HP)
- Secondary voltage:
- 400 V
- Protection type (IP code):
- IP00
- Temperature:
- 40 °C
- Empty load weight:
- 2,750 kg
- Space requirement width:
- 1,600 mm
- Space requirement length:
- 1,000 mm
- Space requirement height:
- 1,920 mm
- Ambient temperature (max.):
- 40 °C
- Roll spacing:
- 820 mm
- Equipment:
- documentation/manual, type plate available
Details about the offer
- Listing ID:
- A18869326
- Reference number:
- 700134
- Update:
- 30.09.2025
Description
Three-phase cast-resin transformer
Gsdsv U Ncrjpfx Aabokc
Designed according to DIN EN 60076-11, VDE 0532, with separate winding
Reduced no-load losses in accordance with Ecodesign Regulation EU No. 548/2014, Eco Directive 2009/125/EC
Design features:
- Flame-retardant and self-extinguishing
- High-voltage winding vacuum-encapsulated, low-voltage winding vacuum-impregnated
- Partial discharge-free (< 5 pC)
- Taps can be changed in the de-energized state using switch lugs
- Mobile design, 4 interchangeable transport rollers
- Winding material: aluminum/aluminum
- 4 lifting eyes, 4 draw eyes, 2 grounding screws
- Documentation: Dimensional drawing, nameplate, data sheet, circuit diagram, operating instructions in German/English - Use of double-sided insulated, grain-oriented, low-loss electrical steel sheets
- Reduced power losses A0 Level 2/Ak (Eco Directive 2009/125/EC)
- Suitable for converter operation, THDu < 5%
- 3x PT100 connected to terminals in the terminal box (IP 54)
RATED POWER: 1000 kVA
CIRCUIT: Dyn5
OVERVOLTAGE: 10 kV, with a value of ± 2x 2.5%
FREQUENCY: 50 Hz
UNDERVOLTAGE: 400 V + N
SHORT-CIRCUIT VOLTAGE: 6% (tolerance ±10%)
NO-LOAD CURRENT: 0.6% (tolerance +30%)
INSULATION LEVEL HV (AC/LI): 12/28/75 kV – L2
INSULATION LEVEL LV (AC/LI):
The listing was translated automatically. Translation errors are possible.
Gsdsv U Ncrjpfx Aabokc
Designed according to DIN EN 60076-11, VDE 0532, with separate winding
Reduced no-load losses in accordance with Ecodesign Regulation EU No. 548/2014, Eco Directive 2009/125/EC
Design features:
- Flame-retardant and self-extinguishing
- High-voltage winding vacuum-encapsulated, low-voltage winding vacuum-impregnated
- Partial discharge-free (< 5 pC)
- Taps can be changed in the de-energized state using switch lugs
- Mobile design, 4 interchangeable transport rollers
- Winding material: aluminum/aluminum
- 4 lifting eyes, 4 draw eyes, 2 grounding screws
- Documentation: Dimensional drawing, nameplate, data sheet, circuit diagram, operating instructions in German/English - Use of double-sided insulated, grain-oriented, low-loss electrical steel sheets
- Reduced power losses A0 Level 2/Ak (Eco Directive 2009/125/EC)
- Suitable for converter operation, THDu < 5%
- 3x PT100 connected to terminals in the terminal box (IP 54)
RATED POWER: 1000 kVA
CIRCUIT: Dyn5
OVERVOLTAGE: 10 kV, with a value of ± 2x 2.5%
FREQUENCY: 50 Hz
UNDERVOLTAGE: 400 V + N
SHORT-CIRCUIT VOLTAGE: 6% (tolerance ±10%)
NO-LOAD CURRENT: 0.6% (tolerance +30%)
INSULATION LEVEL HV (AC/LI): 12/28/75 kV – L2
INSULATION LEVEL LV (AC/LI):
The listing was translated automatically. Translation errors are possible.
Documents
Seller
Note: Register for free or log in, to access all information.
Registered since: 2025
Send inquiry
Telephone & Fax
+49 3461 ... show
Your listing has been deleted successfully