Regenerative Thermal OxidizerFLOW & THERMAL
Regenerative Thermal Oxidizer
FLOW & THERMAL
Year of construction
2021
Condition
Used
(fully functional)
Location
El Prat de Llobregat 

Machine data
- Machine type:
- Regenerative Thermal Oxidizer
- Manufacturer:
- FLOW & THERMAL
- Year of construction:
- 2021
- Condition:
- ready for operation (used)
- Functionality:
- fully functional
Price & Location
- Location:
- 08820 El Prat de Llobregat, Barcelona, Spain

Call
Details about the offer
- Listing ID:
- A22579467
- Reference number:
- PTV-062
- Update:
- 19.08.2026
Description
FLOW & THERMAL Regenerative Thermal Oxidizer (RTO), 18,000 Nm³/h (2021)
Complete industrial system for the treatment of process water containing Volatile Organic Compounds (VOCs), consisting of stripping columns and a three-chamber Regenerative Thermal Oxidizer.
Manufactured by Flow & Thermal Solutions / TECAM in 2021, the equipment was installed at a PET production plant and remained operational until the factory closed on 27 November 2025.
The system removes VOCs from the water by means of air stripping and subsequently destroys them in the RTO through high-temperature thermal oxidation. Heat recovery through ceramic media helps reduce natural gas consumption.
Main features
• Manufacturer: Flow & Thermal Solutions / TECAM
• Year: 2021
• Serial number: F002
• RTO nominal capacity: 18,000 Nm³/h
• Configuration: three-chamber regenerative RTO
• Fuel: natural gas
• Honeywell / Eclipse TJ 200 burner
• Burner output: 58–586 kW
• Electrical supply: 400 V, 50 Hz
• Electrical power stated on the nameplate: 40 kW
• 30 kW Soler & Palau ATEX main fan
• Siemens PLC automation with HMI touchscreen
• LEL monitoring, purge, dilution, bypass and pneumatic valve systems
• Vertical stack: 10 m high, diameter: 800 mm
• CE marked
Performance and operation
The equipment operated at actual flow rates close to its nominal capacity, with recorded values ranging from approximately 16,400 to 17,900 Nm³/h.
The latest available emissions test, carried out by DEKRA in December 2023, recorded the following values:
• TOC: 13 mgC/Nm³
• NOx: 3–4 mg/Nm³
• CO: 125–153 mg/Nm³
During the tests, the equipment operated at an approximate temperature of 775–780 °C, with a treated water flow rate of 3.5 m³/h.
Stripping columns
The system includes:
• Original stripping column, designed for approximately 6 m³/h.
• Second Tecnium SLFKK9 stripping column, manufactured in PPH, with a nominal capacity of 8 m³/h and a maximum capacity of 10 m³/h.
Pjdpfxozvckno Aphegr
The second column was installed, but it is currently dismantled and lying on the ground after being knocked down by strong winds during the winter. It has a hole in the base which, according to the available information, is considered potentially repairable.
The Tecnium column is equipped with internal packing, distributors, a mist eliminator, connections, drainage and provisions for integration with the existing control system.
Condition and maintenance
The system remained operational until the final closure of the plant in November 2025.
The latest preventive maintenance was carried out by TECAM in June 2025 and included mechanical and electrical inspection, burner, fans, stripping columns, instrumentation, valves and functional testing.
The equipment was operational, although maintenance work is required before recommissioning, mainly involving:
• Process valves
• Internal insulation of the towers
• Ductwork and seals
• Main fan impeller and expansion joints
• Repair of the base of the second stripping column
TECAM technical documentation is available regarding the recommended works, and several spare parts are also available.
Scope of supply
The system includes:
• Three-chamber RTO
• Combustion chamber
• Burner and gas train
• Main fan
• Two stripping columns
• Dilution and purge system
• Hot bypass
• LEL analysers
• Stack
• Ductwork
• Electrical cabinets and controls
• Platforms, ladders and support structures
• Available spare parts
Complete industrial system for the treatment of process water containing Volatile Organic Compounds (VOCs), consisting of stripping columns and a three-chamber Regenerative Thermal Oxidizer.
Manufactured by Flow & Thermal Solutions / TECAM in 2021, the equipment was installed at a PET production plant and remained operational until the factory closed on 27 November 2025.
The system removes VOCs from the water by means of air stripping and subsequently destroys them in the RTO through high-temperature thermal oxidation. Heat recovery through ceramic media helps reduce natural gas consumption.
Main features
• Manufacturer: Flow & Thermal Solutions / TECAM
• Year: 2021
• Serial number: F002
• RTO nominal capacity: 18,000 Nm³/h
• Configuration: three-chamber regenerative RTO
• Fuel: natural gas
• Honeywell / Eclipse TJ 200 burner
• Burner output: 58–586 kW
• Electrical supply: 400 V, 50 Hz
• Electrical power stated on the nameplate: 40 kW
• 30 kW Soler & Palau ATEX main fan
• Siemens PLC automation with HMI touchscreen
• LEL monitoring, purge, dilution, bypass and pneumatic valve systems
• Vertical stack: 10 m high, diameter: 800 mm
• CE marked
Performance and operation
The equipment operated at actual flow rates close to its nominal capacity, with recorded values ranging from approximately 16,400 to 17,900 Nm³/h.
The latest available emissions test, carried out by DEKRA in December 2023, recorded the following values:
• TOC: 13 mgC/Nm³
• NOx: 3–4 mg/Nm³
• CO: 125–153 mg/Nm³
During the tests, the equipment operated at an approximate temperature of 775–780 °C, with a treated water flow rate of 3.5 m³/h.
Stripping columns
The system includes:
• Original stripping column, designed for approximately 6 m³/h.
• Second Tecnium SLFKK9 stripping column, manufactured in PPH, with a nominal capacity of 8 m³/h and a maximum capacity of 10 m³/h.
Pjdpfxozvckno Aphegr
The second column was installed, but it is currently dismantled and lying on the ground after being knocked down by strong winds during the winter. It has a hole in the base which, according to the available information, is considered potentially repairable.
The Tecnium column is equipped with internal packing, distributors, a mist eliminator, connections, drainage and provisions for integration with the existing control system.
Condition and maintenance
The system remained operational until the final closure of the plant in November 2025.
The latest preventive maintenance was carried out by TECAM in June 2025 and included mechanical and electrical inspection, burner, fans, stripping columns, instrumentation, valves and functional testing.
The equipment was operational, although maintenance work is required before recommissioning, mainly involving:
• Process valves
• Internal insulation of the towers
• Ductwork and seals
• Main fan impeller and expansion joints
• Repair of the base of the second stripping column
TECAM technical documentation is available regarding the recommended works, and several spare parts are also available.
Scope of supply
The system includes:
• Three-chamber RTO
• Combustion chamber
• Burner and gas train
• Main fan
• Two stripping columns
• Dilution and purge system
• Hot bypass
• LEL analysers
• Stack
• Ductwork
• Electrical cabinets and controls
• Platforms, ladders and support structures
• Available spare parts
These listings may also fit your interest.
Listing
Cremona
6,781 km
Howden TWIN CA46 1.6 MW steam turbine
HowdenKK&K TWIN CA46
HowdenKK&K TWIN CA46
Listing
Germany
6,760 km
Wind Turbine
VestasV52-MK3
VestasV52-MK3
Listing
Bergkamen
6,955 km
Chain excavator
CATERPILLAR352 mit CE und EPA
CATERPILLAR352 mit CE und EPA
Listing
France
7,377 km
Wheel Loader
Caterpillar966 M XE
Caterpillar966 M XE
Listing
Bergkamen
6,955 km
Chain excavator
CATERPILLAR336 Baujahr 2021 CE
CATERPILLAR336 Baujahr 2021 CE
Listing
Geertruidenberg
7,149 km
Crawler excavator
Caterpillar374 F L
Caterpillar374 F L
Listing
Germany
6,760 km
Combined Heat and Power Plant
Jenbacher/ StamfordJMS 612 GS-N.L
Jenbacher/ StamfordJMS 612 GS-N.L
Listing
Passau
6,530 km
Chain excavator
LIEBHERRR970 S HD
LIEBHERRR970 S HD
Your listing has been deleted successfully
An error has occurred