Used Weiss Weiss Climate Test Chamber Sb11/300/40 -40.. for sale (42,848)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
7,016 km
Climate test chamber with seat pulsator
WeissSD 1400/+20 DU
Call
Condition: good (used), Weiss Climatic Test Chamber with Seat Pulsator
Manufacturer: Weiss
Type: SD 1400/+20 DU
Test Chamber:
Material: Stainless steel
Dimensions
Height approx. 800 mm
Width approx. 2000 mm
Depth approx. 900 mm
Capacity: 1440 liters
Outer casing
Material: Double-coated Zincor sheet
Dimensions
Height approx. 2000 mm
Width approx. 2200 mm
Depth approx. 2000 mm
HxWxD 2000 x 2200 x 2000 mm
Paint finish: Light gray (RAL 9002)
Double-leaf door: hinged on the left and right
Equipment:
Tubing in the floor and ceiling: 2 each, NW 100 mm, for installing the pulsator tables
Tubing in the the side walls: 1 each, left and right, 100 mm
Cooling unit: Air-cooled
Control: Digital measurement and control system DMR
Basic control panel: Integrated into the main switch panel
Interface: RS 232 C, for connection to a PC
Software: Operating software for MS Windows
Performance data:
Temperature range without air conditioning: +20...+100 °C
Temperature stability without air conditioning: +0.2 ... t0.5 K (over time) depending on the range, in steady state
Temperature range with air conditioning: 20...+95 °C
Temperature stability with air conditioning: +0.2 ... +0.5 K (over time) depending on the range, in steady state
Dew point range: 20...+94 °C
Humidity range: 10...98 % RH
Humidity stability: +3 ... +5 % RH depending on the range, in steady state
Temperature change rate measured in the exhaust without a test specimen and without load
- Cooling: 0.5 K/min on average, between +100 and +20 °C
⁃ Heating: 0.5 K/min. On average, between +20 and +100 °C
The performance specifications refer to an ambient temperature of max. +25 °C and the specified nominal voltage.
For proper operation of the system, the ambient temperature must be between +10 and +35 °C.
Seat test device with steel construction for placing and attaching to the climatic test chamber, including:
• 2 pneumatic weight lifting devices (150 mm stroke) for changing test specimens, 12 weights of 5 kg each
• 1 base frame in mild steel welded construction for attaching to the underside of the climatic test chamber. This frame is equipped with removable panels on all sides and has two hinged doors for adjusting the eccentricity. These doors have safety switches.
• 2 eccentric discs with bearings and tachometer, 2 connecting rods, 2 ball bearings,
• 2 mounting tables, perforated, 20 mm grid, 650 x 650 mm, for attaching the test specimens, made of aluminum, thickness min. 10 mm
• 2 mounting plates, perforated, 20 mm grid, 200 x 200 mm, for attaching the buttocks simulation
• 2 stainless steel 60° load rods (The connection to the test specimen is not included in our price, but can be offered subsequently upon precise specification.)
• 2 three-phase motors, 2 belt drives with tensioning devices,
Iodpoxbgrgefx An Deia
• 1 pneumatic control unit with 2 manual valves, a filter-regulator unit, and a shut-off valve. 1 electrical control cabinet with 2 SEW frequency converters, hand switches, emergency stop button, 2 on/off switches, 2 speed indicators, 2 potentiometers for speed adjustment, 2 pre-selected load changers with zero position and shutdown.
Technical specifications:
Frequency: 100-1000 strokes/minute
Load: 2 x 45 g
Stroke: 0-40 mm
Load from above: 450 N each
Financing through our bank is also possible.
komplett-konzept.leasingo.de
You can find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
7,016 km
Large-scale climate test chamber
VötschVCZ 04032
Call
Condition: good (used), Large-scale system for climate tests with S!MCON control
Design
The system consists of the following main components:
- Walk-in, insulated test room
- Air treatment room
- Machine unit
- Air conditioning system
- Control cabinet
Test room
The fixtures in the test room are made of corrosion-resistant material.
The test room can be illuminated, is walk-in, and has a condensate and cleaning drain.
Air treatment room
The air treatment room is located behind the air baffle in the insulated interior.
It contains the following components necessary for temperature control and is accessible via easily removable panels.
- Test room fans
- Heat exchangers
- Electric heaters
- Ventilation and exhaust system
- Temperature sensors
Iodpfx Anew U Sv Ej Dsia
In the air treatment room, the air is tempered (cooled/heated), humidified and dehumidified, and circulated by fans.
The air is drawn in under the ceiling and expelled at floor level.
Sensors
The temperature and humidity sensors are located behind the air baffle in the air treatment room.
Machine Unit
The machine unit, consisting of refrigeration units, supplies the air treatment room with the required energy.
Climate System
The climate system consists of:
- Steam humidifier
- Dehumidification evaporator
Technical Data
Test chamber volume: approx. 32 m³
Direct temperature range: -40 to +100°C
Temperature fluctuation over time in the center of the usable space: +/- 0.5 to +/- 1
Temperature change rate
Heating: from -35°C to +50°C at 3 K/min
Cooling: from +85°C to +85°C at 2 K/min
from +80°C to -40°C at 1 K/min
Data for climate testing
Temperature range: 10 to 95°C
Humidity range: 10 to 95% RH
Dew point range: 5 to 93°C
Temperature fluctuation: +/- 5°C
Humidity fluctuation: +/- 3 to +/- 5% RH
Cooling water specifications
Connections
Inlet: 2 x 1 1/2" RH
Return: 2 x 1 1/2" RH
Consumption at full load: max. 16 m³/h
Maximum load on the test chamber floor: 10,000 N/m²
Nominal voltage: 3/N / PE AC 400 V 50 Hz
Nominal power: 97 kW
Nominal current: 148 A
Dimensions:
Test chamber: Width 3.60 m, Height 2.20 m, Depth 5 m
Climate chamber divided for transport at a specified location (approx. 2.50 m).
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items – new and used – in our shop!
International shipping costs on request!
Listing
Borken
7,016 km
Temperature test chamber Climate test
VötschVTR 7033/S
Call
Year of construction: 1997, condition: good (used), Vötsch VTR 7033/S Temperature Test Chamber
Manufacturer: Vötsch
Type: VTR 7033/S
Item No.: 60885637
Temperature Chamber
Temp. Range: -70°C to +180°C
Line Voltage: 400V
Iijdpfxsuuiv Is An Doa
Rated Current: 24A
Rated Power: 9.5 kW
Refrigerant (VK): R 404 A
Refrigerant (TK): R 23
Year of Manufacture: 1997
TK 08
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs upon request!

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Borken
7,016 km
Climate test chamber Temperature test
VötschVCS 4100
Call
Condition: good (used), Vötsch VCS 4100 Climatic Test Chamber -40°C to +180°C
Manufacturer: Vötsch
Type: VCS 4100
Temp. Range: -40°C to +180°C
Line Voltage: 400 V
Rated Current: 17 A
Rated Power: 11 kW
Iedpfxouuiyge An Doia
Refrigerant: R404A
KK-07
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
7,016 km
Climate test chamber Temperature test
Heraeus VötschHC 4055
Call
Condition: good (used), Heraeus Vötsch HC 4055 Temperature Test Chamber
Iiedpouuilvofx An Dsa
Manufacturer: Heraeus Vötsch
Type: HC 44055
Temperature Chamber
Temperature Range: +180°C
Rated Voltage: 380V, +-10%, 3/N, 50Hz
Rated Current: 13.5 A
Rated Power: 9 kW
Housing Dimensions: W 1065 x D 1560 x H 1890 (mm)
Observation Window: Width x Height 350 x 640 mm
Test Chamber: (L x D x H) approx. 800 x 795 x 855 mm
Test Chamber Volume: 550 l
Cabinet is air-cooled
Caution
Cabinet can only be operated as an oven.
Refrigeration circuit empty and shut down.
Air conditioning system shut down.
Disconnected contactors:
03K2 Compressor
03K5 Condenser fan
15K6 Panel heater
Solid state relay 21V4 Humidifier.
Weight approx. 550 kg
Financing through our bank is also possible.
komplett-konzept.leasingo.de
More items - new and used - can be found in our shop!
International shipping costs on request!
Listing
Borken
7,016 km
Climate test chamber Temperature test
VötschVTSR 7034/S
Call
Year of construction: 2002, condition: good (used), Vötsch VTSR 7034/S Climatic Test Chamber -70 to +180°C
Manufacturer: Vötsch
Type: VTSR 7034/S
Test Chamber Capacity: 335 liters
Climatic Test Chamber
Temp. Range: -70 to +180°C
Line Voltage: 3/N/PE AC, 400 V ±10%, 50 Hz
Rated Current: 22 A
Rated Power: 12.5 kW
Refrigerant (VK): R 404 A
Refrigerant (TK): R 23
Test Chamber Dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External Dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Year of Manufacture: 2002
Iisdpfx Ansuuif Ne Dea
TK-11
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs on request!
Listing
Borken
7,016 km
Walk-in climate test chamber
VötschVSKZ 04/120/S
Call
Year of construction: 1996, condition: excellent (used), Vötsch VSKZ 04/120/S Walk-In Climatic Test Chamber
Manufacturer: Vötsch
Type: VSKZ 04/120/S
Temp. Range: -40°C to +120°C
Line Voltage: 400V
Rated Current: 95A
Rated Power: 56 kW
Refrigerant: R 404 A
Year of Manufacture: 1996
External Dimensions: W 2850 x D 4100 x H 3080 mm
Iiedpfeuuigyex An Dsa
SO-01
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs on request!
Listing
Borken
7,016 km
Temperature shock chamber climate test
NemaNTS 3000 / 2S
Call
Year of construction: 2000, condition: good (used), Nema Temperature Shock Test Chamber -40°C to +120°C
Manufacturer: Nema
Type: NTS 3000 / 2S
Temp. Range: -40°C to +120°C
Line Voltage: 400 V
Rated Current: 88 A
Rated Power: 55 kW
Refrigerant: R 404 A
Year of Manufacture: 2000
Weight: 5000 kg
External Dimensions: W 4000 x D 2760 x H 3450 mm
Chamber: W 3000 x D 1250 x H 1610 mm
Ijdpfxouuiayj An Doia
TS-06
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
7,016 km
Corrosion climate change test chamber
WEISSSC 1000/+20IU
Call
Condition: excellent (used), Weiss SC 1000/+20IU Corrosion Climatic Cycle Test Chamber
Weiss SC 1000/+20 JU Corrosion Climatic Cycle Test Chamber
The test system is a combination of a climatic test chamber with variable temperature and humidity and a corrosion test chamber with a salt spray test.
At-risk metallic components are tested for corrosion in a time-lapse manner according to the relevant standards.
Temperature Working Range
Temperature: +20 °C ... +60 °C
Temperature variation over time: +0.5 °C
Climatic Working Range
Temperature: +20 °C ... +60 °C
Temperature variation over time: +0.5 °C
Relative Humidity: 10...98 % RH
Temperature variation over time: 3...5 % RH
Dew point: +12 °C ... +59 °C
Salt spray test SS (ambient temperature range +5 °C ... +50 °C)
according to DIN 50 021 (salt spray via dual-fluid nozzle, 1.5 x 0.5 mV 80 cm h)
Control
Digital measurement and control system SIMCON/32*-Net with touchscreen control panel
Interfaces - Serial interface RS 232 C - Parallel printer interface
Operating modes adjustable via process controller:
- Temperature mode
- Air conditioning mode
- Salt spray test
- Direct spraying with saline solution
- Condensate load
- Flushing test chamber walls
- Drying/ventilating test chamber
Temperature sensor: Pt 100 resistance thermometer
Humidity sensor: Psychrome fresh measuring device TFT (with forced humidification)
Technical data SC 1000/+20 JU
Usable space dimensions
Height up to
sloped roof approx. 1000 mm
+ roof approx. 350 mm
Iiodpeph U Dhjfx An Dea
Width approx. 1100 mm
Width between heaters approx. 1000 mm
Depth approx. 1000 mm
Test room door made of glass, hinged on the left
Height approx. 1350 mm
Width approx. 1000 mm
External dimensions including unit components and control cabinet
Height approx. 2100 mm
Width approx. 1450 mm
Width with touch control panel approx. 1700 mm
Depth approx. 2600 mm
Floor load max. 100 kg
Brine storage tank
approx. 200 l, with level monitoring separately next to/behind the unit
Height approx. 1000 mm
Width approx. 600 mm
Depth approx. 900 mm
Electrical connection: 400 V
Power rating: 13 kW
Weight: 1300 kg
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items – new and used – in our shop!
International shipping costs on request!
Listing
Borken
7,009 km
Climatic test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Type: VCS 7034-5
Water-cooled climatic test chamber
Vötsch VCS 7034-5
Test chamber capacity 335 liters
Performance for temperature tests
Temperature range -70 to +180°C
Temperature deviation temporal K ±0.1 to ±0.5
Spatial temperature deviation K ±0.5 to ±2.0
Temperature gradient 1 to 4
Rate of change :
Cooling 6.7 K/min
Heating 6.8 K/min
Heat compensation at +20 °C 3000 W / at -20°C 3000 W
Temperature calibration values +23 °C and +80 °C
Performance for climate tests
Temperature range +10 to +95°C
Temperature deviation in time ±0.1 to ±0.3 K
Spatial temperature deviation ±0.5 to ±1.0 K
Temperature gradient 1 to 2 K
Humidity range 10 to 98%
Humidity deviation in time ±1 to ±3%
Dew point range -3 to +94°C
Heat compensation 400W
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 580mm Depth 765mm Height 750mm
External dimensions: Width 870mm Depth 1595mm Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Iiodpfx Ajuudx Don Dja
Sound pressure level: 64dB(A)
Cooling water consumption: 1.4m³/h
Refrigerant: R-404A / R-23
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Climate test chamber 280 liters
FeutronKPK 200 Typ: 3416/16 +5 °C bis +100 °C
Call
Condition: excellent (used), Here we offer a climatic test chamber.
Air cooled
Nominal test chamber volume: 280 liters
Dimensions
Isdpfx Anjiz Tqce Deia
Test chamber outside: 1500 x 2040 x 1075 mm
Fan motor and door disassembled: 1500 x 1940 x 925 mm
test chamber: 720 x 690 x 560 mm
door, clear width: 720 x 690 mm
viewing window, heated: 500 x 600 mm
Temperature range
+5 to +100 C
heating: 4,0 K /min
Cooling: 0.6 K /min
Climate range +10 to +95 C
Humidity range: 10 to 95 % r.H.
Humidity difference, temporal: ≤ ± 3.0
Water connection humidifier: city water or distilled water 20l reservoir tank.
Mains connection: 400 V 3/N/PE, AC, 50 Hz
Power requirement max : 6,3 kW
Weight : 500 Kg
Type : 3416/16
Refrigerant : R134a
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,009 km
Climate test chamber Temp. -70°C to +180°C
Vötsch 190 LiterVCS 7018-5
Call
Condition: excellent (used), Heraeus Vötsch
Type: VCS 7018-5
Climatic Test Chamber with Humidity Control, Water-Cooled
Test Chamber Dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing Dimensions: Width 870 mm x Depth 1280 mm x Height 1775 mm
Characteristics for Temperature Tests:
Temperature Range: -70°C to +180°C
Temperature Range: ± 0.1 to ± 0.5 K
Spatial Range: ± 0.5 to ± 2.0 K
Iiodpov N Hc Esfx An Dea
Temperature Gradient: 1 to 4 K
Temperature Rate of Change according to IEC 60068-3-5
Heating: 7.5 K/min
Cooling: 7.5 K/min
Characteristic values for climatic tests:
Temperature range +10 to +95°C
Humidity range: 10 to 98% RH
Temperature deviation over time: ± 0.1 to ± 0.3 K
Temperature deviation over space: ± 0.5 to ± 1 K
Temperature gradient: 1 to 2 K
Humidity fluctuation over time: ± 1 to ± 3% RH F.
Dew point range -3 to +94 °C
Electrical connection:
Nominal voltage: 3/N/PE AC 400V±10% 50Hz
Nominal power: 10 kW
Nominal current: 21 A
Fuse protection: 32 A slow-blow, provided by the customer
Refrigerant: R-404A / R-23
Test chamber volume: approx. 190 liters
Weight: approx. 460 kg
For your safety, please note the following information!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Climate test chamber with humidity
WeissSB2/500/80 -75°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss climate test chamber.
Designation: SB2/500/80 water cooled
Cold-heat operation: -75°C ...+180°C
Climatic operation: +10...+95°C
Humidity range: 10...98 % r. h.
Iedpfx Anjm Tvzcs Doia
Temperature constancy, temporally ± 0.2K
Humidity constancy: ±1 r.F.
Temperature rate of change:
Cooling: approx. 1.4 K/min
Heating up: approx. 2.5 K/min
External dimensions: Height 1980 mm, width 1265 mm, depth 1365 mm
Feedthroughs:
left side: ∅ 100 mm
right side: ∅ 50 mm
The connection voltage is:
400V/3Ph+N+PE/ 50 Hz
Power: 10,4 kVA
Weight: approx. 720 kg
Refrigerant R404a / R 23
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: SB2/500/80
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,009 km
Climate test chamber 900 liters
CTSCS-70/900 -70...+180°C
Call
Condition: used, Type: CS-70/900
CTS Climate Test Chamber with Humidity, water-cooled
Iodjxb Dm Ijpfx An Doia
(converted to R-452a refrigerant)
Temperature range: -70°C to +180°C
Humidity range: 10–98% RH
Test chamber internal dimensions: Height approx. 870 mm / Width approx. 1000 mm / Depth approx. 1000 mm
External dimensions: Height approx. 1950 mm / Width approx. 1200 mm / Depth approx. 2220 mm
Control cabinet dimensions: Height approx. 2100 mm / Width approx. 800 mm / Depth approx. 400 mm
Test chamber volume: 900 liters
Refrigerant: R-452a / R23
Electrical connection: 400 V +6/-10%, 3/N, 50 Hz
Connected load: 21.2 kW, Rated current: 35.7 A
Chamber weight: 900 kg
Control cabinet weight: 150 kg
Important safety information for buyers:
The following steps are carried out on all chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. Refilled with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see photo)
(Specifications and technical data subject to change and errors reserved!)
For any further questions, please contact us by phone.
Listing
Borken
7,009 km
Climate test chamber with humidity 34 liters
VötschVCL 7003 -70°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VCL 7003
Air-cooled climatic test chamber
Test chamber capacity approx. 34 liters
Capacity for temperature tests:
Temperature range -70 to +180°C
Temperature deviation over time ±0.3 to ±1.0 K
Temperature homogeneity over space ±0.5 to ±2.0 K
Heating rate of change 4.0 K/min
Cooling rate of change 3.0 K/min
Heat compensation max. 550 W
Temperature calibration value +23°C and +80°C
Capacity for climatic tests:
Temperature range +10 to +95°C
Humidity range 10 to 98%
Humidity deviation over time ±1 to ±3%
Temperature deviation over time ±0.3 to ±0.5 K
Spatial temperature homogeneity ±0.5 to ±1.5 K
Climate calibration values +23 °C / 50% RH and +95 °C / 50% RH
Test room dimensions: Width 350 mm, Depth 300 mm, Height 310 mm
External dimensions: Width 640 mm, Depth 750 mm, Height 1730 mm
Electrical connection:
1/N/PE AC 230 V ±10%, 50 Hz
Rated current 11.0 A
Rated power, max. 2.5 kW
Sound pressure level 59 dB(A)
Refrigerant: R-404 A / R23
Weight approx. 130 kg
For your safety, please note the following information as a buyer!
Iiedpfx Ajv Tnd Sen Dja
The following steps are performed on our chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Climatic test chamber shaker chamber 2160 liters
WeissWK3-2200/40/5/V -40°C bis +180°C
Call
Condition: excellent (used), Weiss
Type: WK3-2200/40/5/V
Weiss Climate Test Chamber, Water-Cooled
Specifications for Temperature Testing:
Temperature range: -40°C to +180°C
Temperature change rates:
Heating: 6.0 K/min
Cooling: 11.5 K/min
Temperature deviation:
Temporal ± 0.8 K
Spatial ± 2.0 K
Heat compensation max. 8000 W
Specifications for Climatic Testing:
Temperature range: +10°C to +95°C
Dew point temperature range: +4°C to +94°C with closed floor element
Humidity range: 10 to 95% rH
Temperature deviation (temporal): ± 0.3 K
Humidity deviation (temporal): ± 3% rH
Temperature uniformity:
Spatial ± 1.0 K
Heat compensation max.: 500 W
Test chamber volume: 2,160 liters
Test chamber dimensions: Height 1,115 mm, Width 1,400 mm, Depth 1,400 mm
External dimensions (lowered): Height 2,318 mm, Width 1,860 mm, Depth 3,658 mm
External dimensions above shaker: Height 2,710 mm
External dimensions max. stroke height: 3,038 mm
Exchangeable floor dimensions: Width 1,600 mm, Depth 1,504 mm
Operating Data:
Rated voltage: 3/N/PE AC 400V +10% 50Hz
Rated power: 38.0 kW
Rated current: 63.0 A
Customer-side fuse: 80 A slow-blow
Refrigerant: R 404A
Weight: approx. 2,100 kg
Important information for your safety as a buyer:
The following points will be carried out on the chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. If required, refilling with refrigerant compliant with legal regulations
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
Iodpfx Aow I Rxrsn Dsia
(Technical data subject to change and errors excepted!)
We are happy to answer any further questions you may have by phone.
Listing
Borken
7,009 km
Climate test chamber Temp. -70 to 180°C
Weiss explosionsgeschütztWK-600/70 (I)-(II) 2 G EEx
Call
Condition: excellent (used), Weiss
Type: WK-600/70 (I)-(II) 2 G EEx /22605147
Weiss climate chamber water-cooled
(test room explosion-proof)
INERTIZATION WITH NITROGEN / EXPLOSION-PROOF TEST ROOM
Technical data:
Test chamber designation: WK-600/70 (I)-(II) 2 G EEx
External dimensions with hinges and door lock
Height 1995 mm, width 1090 mm, depth 1660 mm
External dimensions without hinges and door lock
Height 1995 mm, width 1000 mm, depth 1660 mm
Test room capacity: approx. 600 liters
Cold / heat operation -70 to 180°C
Climate operation 10 – 95°C
Humidity 10...98% r. H.
Temperature change per time
Cooling approx. 2.5 K/min
Heating approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 14 kW
Rated current: 25 A
On-site fuse: 32 A slow-blow
Permissible test item weight
Total load of the grate supports 80 kg
Test room floor 80 kg, grate insert 40 kg
Weight: 800 kg
Refrigerant: R 404A/R 23
(The air conditioning system's evaporator has been replaced)
For your safety as a buyer, the following information! The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
Ijdpfxev Ewy Ho An Doia
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Climatic test chamber -70°C to +180°C
VötschVCS 7034-5 - 335 Liter
Call
Condition: used, Vötsch
Type: VCS 7034-5
Water-cooled climatic test chamber
Test chamber capacity 335 liters
Performance for temperature tests
Temperature range -70 to +180°C
Temperature deviation in time K ±0.1 to ±0.5
Spatial temperature deviation K ±0.5 to ±2.0
Temperature gradient 1 to 4
Rate of change :
Iiedpfsuxq T Dox An Dja
Cooling 6.7 K/min
Heating 6.8 K/min
Heat compensation at +20 °C 3000 W / at -20°C 3000 W
Temperature calibration values +23 °C and +80 °C
Performance for climate tests
Temperature range +10 to +95°C
Temperature deviation in time ±0.1 to ±0.3 K
Spatial temperature deviation ±0.5 to ±1.0 K
Temperature gradient 1 to 2 K
Humidity range 10 to 98%
Humidity deviation in time ±1 to ±3%
Dew point range -3 to +94°C
Heat compensation 400W
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 580mm Depth 765mm Height 750mm
External dimensions: Width 870mm Depth 1595mm Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64dB(A)
Cooling water consumption: 1.4m³/h
Refrigerant: R-404A / R-23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Climatic test chamber
Feutron3702/06
Call
Condition: excellent (used), Feutron
Type: 3702/06
Water-cooled climatic test chamber
Technical data:
Test chamber nominal volume 2.0 m³
Dimensions: Test chamber exterior, with humidifier console
Width 2970 mm Height 2370 mm Depth 1530 mm
Rear wall
Minimum insertion dimensions: Width 2970 mm Height 2390 mm Depth 1550 mm
Test chamber: Width 2000 mm Height 1000 mm Depth 1000 mm
Double-leaf door, clear width Width 2000 mm Height 1000 mm
Heated viewing window, 2 pieces Width 500 mm Height 600 mm
Feed-through opening, 1 side panel left ∅ 75 mm
Temperature range: -40...100°C
Climatic range: 10...95°C
Temperature difference, temporal ≤ ± 0.5...± 1.0 ΔN/K
Change rates measured in the supply air without load
Cooling up to 2.0 on average K/min
Heating up to 2.0 on average K/min
Iiodpfx Ask E Hnqon Dja
Humidity range: 10...95 %r. F.
Humidity difference, temporal ≤ ± 3.0 %r. F.
Dew point range, temporary down to -5... 95°C
Refrigeration system: water-cooled semi-hermetic Bitzer system
Refrigerant: R507 (Μ-Κ1)
Air conditioning and dryer refrigeration system air-cooled /hermetic system
Refrigerant: R134a (Μ.ΚΚ)
Power supply:
Electrical mains connection: 400V 3/N/PE.AC,50Hz
Mains plug: CEE 5-роlig, 32 A, with 5.0 m cable
Max. simultaneous power requirement 10.0 kW
Supply line fuse: 3x 25, Char, C A
Degree of protection IP20
Weight: 1300 kg
Condition: used
Scope of delivery: (see picture)
(Subject to changes and errors in the technical data and specifications)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Climate test chamber with humidity 190 liters
VötschVC 7018 -70 bis 180°C
Call
Condition: excellent (used), Vötsch
Type: VC 7018
Vötsch Climatic Test Chamber VC 7018 Water-Cooled
Touch Panel Control Unit
On the touch panel control unit, all control and operating commands can be triggered by simply touching the function symbols.
Adjustable Feet
Iedpfx Aswgayksn Djia
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Ports
The test chamber is equipped with port holes on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Feedthrough included in standard equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Characteristics for temperature tests:
Temperature range: -70°C to +180°C
Temperature ±0.1 to ±0.5 K
Spatial ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min
Cooling: 2.3 K/min
Characteristics for climatic tests:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% r.h. F.
Temperature deviation over time in the center of the usable space ± 0.1 to ± 0.3 K
Temperature deviation over space ± 0.5 to ± 1.0 K
Temperature gradient 1 to 2 K
Humidity deviation over time in the center of the usable space ± 1 to ± 3 %RH
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10 50Hz
Nominal power: 5.9 kW
Nominal current: 12.0 A
Connection cable: 3.5 m
Fuse protection: 16 A slow-blow, provided by the customer
Refrigerants: R-404A and R-23
Test chamber capacity: approx. 190 liters
Weight: approx. 460 kg net
For your safety, the following information is provided as a buyer!
The following steps are performed on our offered chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Climatic test chamber 800 L, -55°C to +180°C
WeissClimeEvent C/800/55a/25/S 25K/min
Call
Year of construction: 2020, condition: excellent (used), Weiss
Type: C/800/55a/25/S
Year of manufacture: 2020
Weiss ClimeEvent Climate Test Chamber, Water-cooled
Chamber volume: 800 liters
Internal dimensions: Height 950 mm, Width 1100 mm, Depth 800 mm
External dimensions: Height 2015 mm, Width 1415 mm, Depth 3156 mm
Floor load capacity: designed for a maximum load of 250 kg
Specifications for temperature testing:
Temperature range: -55 to +180°C
Temporal temperature fluctuation at chamber center: ±0.1 to ±0.5 K
Spatial temperature deviation (temperature gradient): 0.5 to 2.0 K
Heating rate: 25 K/min
Cooling rate: 25 K/min (down to -45°C)
Heating compensation: max. 8000 W
Specifications for climate testing:
Temperature range: +10 to +95°C
Humidity range: 10 to 98% RH
Climate performance data (excerpt)
Humidity range: 10 to 98% relative humidity (RH)
Humidity deviation (temporal):
Iijdpew R Rt Iefx An Dja
At chamber center, in steady-state condition, depending on climatic setting:
±1 to ±3% RH
Temperature deviation (temporal):
At chamber center, in steady-state condition, depending on temperature:
±0.1 to ±0.3 K
Temperature uniformity (spatial):
Relative to the setpoint (in the range > 20% RH):
±0.5 to ±1 K
Operational data:
LED strip: 24 V, 6.8 W / 2 x Halogen lamp 24 V, 50 W
Rated voltage: 3/N / PE AC 400 V ± 10%, 50 Hz
Rated power: 53 kW
Rated current: 87 A
Refrigerant: WT69-R449A
Chamber is equipped with Greenmode
Weight: approx. 2050 kg
Buyer Safety Information!
The following steps are performed on all chambers we offer:
1. Functional inspection and replacement of necessary components
2. Refill with legally compliant refrigerant if required
3. Leak test with certificate
4. Upon successful testing, chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical data are subject to change and error!)
For further questions, we are happy to answer your call.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
7,009 km
Battery test system with climate chamber
Keysight / Scienlab / AngelantoniBatterie-Testsystem SL1001A
Call
Condition: used, Keysight / Scienlab Battery Test System SL1001A + Angelantoni Climate Chamber DM500 C 10 ESS SPEEDY BT SP
Complete Battery Testing System – For Laboratory Use
Incl. PC, software & technical documentation
For sale is a professional battery test system, consisting of:
- Keysight / Scienlab SL1001A Battery Test System
- Angelantoni DM500 C 10 ESS SPEEDY BT SP Climate Chamber
- Monitoring/Sampling Unit
- Control PC with original software
- Technical documentation
The system is fully functional, well-maintained, and ideally suited for battery module testing, research, development, and quality assurance.
Technical Data – Scienlab SL1001A:
- Manufacturer: Keysight / Scienlab
- Model: SL1001A
- Year of manufacture: 2020
- Voltage / Current / Power: 80 V / 600 A / 24 kW
- Dimensions (L×W×H): approx. 1.6 × 0.9 × 3.3 m
- Weight: approx. 700 kg
- Function: Charging, discharging, and cycling of battery modules
- Condition: Very well maintained, laboratory use only
Technical Data – Angelantoni DM500 C 10 ESS SPEEDY BT SP:
- Manufacturer: Angelantoni Industrie S.r.l., Italy
- Model: DM500 C 10 ESS SPEEDY BT SP
- Year of manufacture: 2019
Iisdpfx Ansxuqk Hs Dsa
- Weight: approx. 1,225 kg
- Temperature range: -70 °C ... +180 °C
- Humidity range: 10 ... 98 % rH
- Refrigerants: R449A + R23
- Pressure ranges (PS Hi/Lo): 28 bar / 8 bar
- Wi-Fi integrated
- CE certification present
- Internal dimensions (L×W×H): approx. 1.6 × 2.3 × 3.3 m
- Function: Temperature and humidity testing, ESS (Environmental Stress Screening)
- Power supply: 3PH + N + PE, 400 V ±10 %, 50 Hz, full load 54 A
- Max. power consumption: 32.5 kW
Monitoring / Sampling Unit:
- Dimensions: 0.6 × 0.5 × 0.2 m
- Measured variables: Cell voltages, current, temperature
- Interfaces: CAN, Ethernet
- Compatible with Scienlab / Keysight PathWave software
PC + Software + Documentation:
- Industrial PC with control and measurement software
- Enables automated test runs, logging, and data analysis
Overall Dimensions / Weight (approx.):
Component Dimensions (L×W×H) Weight
Scienlab SL1001A 1.6 × 0.9 × 3.3 m 700 kg
Angelantoni Chamber 1.6 × 2.3 × 3.3 m 1,225 kg
Monitoring / PC 0.6 × 0.5 × 0.2 m 50 kg
Total system L 3.2 m × W 2.5 m × H 3.3 m approx. 1,975 kg
Applications:
- Development, testing, and lifespan analysis of battery modules (e.g., Li-ion, LFP, NMC)
- Fast charging and cycle tests
- Environmental simulation for temperature and humidity
- Research, industrial, and university laboratories
Important Note:
"The table shown in the photos is not included in the sale."
Scope of Delivery:
- Scienlab SL1001A power unit
- Angelantoni DM500 C 10 ESS SPEEDY BT SP climate chamber
- Monitoring/Sampling unit
- Control PC with software
- Technical documentation and manuals
- Connection cables and accessories (as available)
Condition: used
Scope of delivery: (see image)
(Specifications and data are subject to change and error!)
For any further questions, we are happy to assist you by phone.
Listing
Borken
7,009 km
Climate test chamber with humidity 800 liters
EspecEGNX28-6CWL -70 bis +180°C
Call
Condition: excellent (used), Espec
Type: EGNX28-6CWL
Espec climate test chamber water-cooled
Climate test chamber N series
Temperature range -70 to +180°C
Temperature change rate
Heating 10 °K/min
Cooling 5.5 °K/min
Humidity range 10 to 95% RH according to diagram
Iisdpfev Duuxex An Dsa
Internal dimensions W x H x D in mm 1000 x 1000 x 800
External dimensions W x H x D in mm 1205 x 1930 x 1960
Usable space volume 800 liters
Cooling capacity 3.6 kW at -50 °C
Heating system 10 kW
Refrigerant R-404A
Refrigerant R- 508A
Power supply:
AC 400 V 3-phase 50/60Hz 38A
Weight: approx. 695 kg
For your safety as a buyer, the following information!
The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Climate test chamber with humidity 335 liters
WeissWK3-340/40 -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss climate test chamber.
Weiss climate test chamber water-cooled
(refrigerant converted to R-452A)
Temperature test
Volume 335 liters
Test chamber dimensions:
Test chamber dimensions: Height 750 mm, width 580 mm, depth 765 mm
External dimensions: Height 1775 mm, width 870 mm, depth 1600 mm
Minimum temperature -42°C
Maximum temperature +180°C
Temperature change rate, cooling 4 K/min
Temperature change rate, heating 3.2 K/min
Temperature deviation, temporal ± 0.1 to ± 0.5 K
Temperature homogeneity, spatial ± 0.5 to ±1.5 K
Climate test:
Iisdpfx Ansq U Sdcj Dea
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range 10 to 98% r.h.
Temperature deviation, temporal ± 0.1 to ± 0.3 K
Temperature homogeneity, spatial ± 0.5 to ±1 K
Humidity deviation, temporal ± 1 to ± 3 % r.h.
Voltage: 3/N/PE AC 400V±10% 50Hz
Rated power 4.1 kW Rated current: 14 A
Refrigerant: R-452A
Type: WK3-340/40
Weight Approx. 515 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Climate test chamber 1540 liters
WeissWK1-1500/40 Temp. -40°C bis +180°C
Call
Condition: used, Weiss
Iisdpfx Asw Hctton Doa
Type: WK1/1500/40
Weiss Climate Test Chamber, Air-Cooled with Humidity Control
(converted to use refrigerant R-452a)
Temperature range: -40°C to +180°C
Cooling rate approx. 2.5 K/min, heating rate approx. 3.5 K/min
Temporal temperature deviation at center of test space: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature range: +10°C to +95°C
Humidity range: 10% to 98% r.H.
Temporal temperature deviation at center of test space: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Heat compensation
In the range of +25°C to +95°C, at a relative humidity up to 90%: 500 W
Test chamber dimensions: Height: 950 mm, Width: 1100 mm, Depth: 1475 mm
External dimensions: Height: 2005 mm, Width: 1300 mm, Depth: 2450 mm
Test volume: approx. 1540 liters
Test chamber lighting: Halogen bulb 12V, 50W
Rated voltage: 3/NPEAC 400V ±10% 50Hz
Rated power: 11.5 kW, Rated current: 22.0 A
Fuse on site: 32A slow-blow
Protection class (control cabinet and operator panel): IP 54
Refrigerant: R-452a
Weight: 920 kg
For your safety as a buyer, please note the following information:
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a test run, monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Technical specifications subject to change and errors excepted!)
If you have further questions, we will be happy to answer them by phone.
We make it easier for you to find: "weiss weiss climate test chamber sb11/300/40 -40.."
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
















































































































































































































































































