Used Heraeus Vötsch Vtl 60/60 for sale (21,667)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Dortmund
6,971 km
El. heated chamber oven
HeraeusBT 5042
Call
Condition: used, functionality: fully functional, El. heated chamber oven, make Heraeus
Type: BT 5042
Temperature: 250°C
Fgjdpfxjxlruzo Ag Aec
Clear dimensions (W x D x H): 390 x 285 x 350 mm
Listing
Borken
7,016 km
Vacuum pump 30m / h 2 stage
Leybold HeraeusTrivac D 30 A & S 30 A
Call
Condition: good (used), Rotary vane vacuum pump oil lubricated
Fgsdpfxob Ii E De Ag Asc
Manufacturer: Leybold
Type: Trivac D 30 A & S 30 A
Voltage: 400V / 50Hz
Suction capacity: approx. 30 m³/h
Ultimate pressure: approx. 5x10e-3 mbar & 5x10e-2
Status: Refurbished
Warranty: 12 months
Accessories: Instruction manual
Mineral oil filling
Quantity: several available
Delivery time. from stock
Listing
Borken
7,009 km
Climate test chamber 335 liters with humidity
VötschVCS³ 7034-5 -70°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VCS³ 7034-5
Vötsch Climate Test Chamber, Water-Cooled
With temperature change rate of 5 K/min
Specifications for temperature testing:
Temperature range: -70°C to +180°C
Temporal temperature deviation in the center of the usable space: ±0.1 K to ±0.5 K
Spatial temperature deviation: ±0.5 K to ±2.0 K
Temperature change rate:
Heating: 6.8 K/min
Cooling: 6.7 K/min
Specifications for climate testing:
Temperature range: +10°C to +95°C
Temporal temperature deviation in the center of the usable space: ±0.1 K to ±0.3 K
Spatial temperature deviation: ±0.5 K to ±1.0 K
Temporal humidity deviation in the center of the usable space: ±1% to ±3% RH
Humidity range: 10% to 98% RH
(Extended climate range: 2°C/95% RH regulated for a maximum of 2 hours)
Exterior dimensions (W x D x H): 870 x 1700 x 1775 mm
Test chamber dimensions (W x D x H): 580 x 765 x 750 mm
Test chamber volume: approx. 335 liters
Side ports: 50 mm and 125 mm
Operating data:
LED strip 24 V, 6.8 W / 2 x halogen bulbs 24 V, 50 W
Rated voltage: 3/N/PE AC 400 V ±10%, 50 Hz
Rated power: 9 kW Rated current: 20 A
Customer-side fuse: 63 A slow-blow
Refrigerant: R404A / R-23
Weight approx. 570 kg
For your security as a buyer, please note the following:
The following procedures are carried out on our offered chambers in advance:
Fedpfxjygvn Ns Ag Ajgc
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant, if needed
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see image)
(Technical data and information subject to change and errors!)
Further questions can be answered by phone.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Borken
7,009 km
Temperature test chamber 990 liters
VötschVT³ 4100 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VT³ 4100
Water-Cooled Temperature Test Chamber
S!MCON/32.NET (with Touch Panel)
Control System Features:
- Color touchscreen with intuitive menu navigation (typically 5.7" or larger)
- Programming of temperature/humidity profiles with ramps and dwell times
- Data acquisition & logging (e.g., temperature profile, alarms)
Fodoygvm Ejpfx Ag Ajgc
- USB port for data export (CSV, optionally S!MPATI compatible)
- Network interface (Ethernet) for remote monitoring and control
- User management with password protection
- Interfaces: Volt-free contacts, optionally Modbus or Profibus
VT³ 4100 – Technical Specifications (Temperature Test Chamber)
- Test volume: 990 liters
- Temperature range: -40 °C to +180 °C
- Temporal temperature deviation: ±0.1 to ±0.5 K
- Spatial temperature deviation: ±0.5 to ±1.5 K
- Temperature gradient: 1 to 3 K
- Temperature change rate (per IEC 60068-3-5):
• Heating: 4.0 K/min
• Cooling: 3.0 K/min
- Maximum heat compensation capacity: 4500 W
- Calibration values: +23 °C and +80 °C
- Internal dimensions (W×D×H): 1100 × 950 × 950 mm
- External dimensions (W×D×H): 1390 × 1955 × 1995 mm
Feed-Throughs:
The chamber is equipped with feed-throughs on both the right and left sides, allowing insertion of measuring cables and test devices into the test space.
• 1 × L1 nominal width 50 mm
• 1 × R1 nominal width 125 mm
• 3 × R1 nominal width 50 mm
Electrical connection: 3/N/PE AC, 400V ±10%, 50Hz
Power consumption: 11.5 kW
Rated current: 22 A
Noise level: approx. 62 dB(A)
Refrigerant: R452A
Weight: 920 kg
Important information for buyers:
For your security, the following measures are carried out on all our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant, if needed
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see picture)
(Subject to change and errors in technical data; information may be subject to alteration!)
For any further questions, feel free to contact us by phone.
Listing
Borken
7,009 km
Climatic chamber
VötschVC³ 4100
Call
Condition: excellent (used), Vötsch Climate Test Chamber
We offer a Vötsch climate test chamber.
Model: VC³ 4100, air-cooled
With a temperature change rate of 3 K/min
Test chamber internal dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
External dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Chamber volume: 990 liters
Feed-throughs: Ø 125 mm, Ø 50 mm
Specifications for temperature tests:
- Temperature range: -42°C to +180°C
- Temporal temperature deviation: ±0.1 to ±0.5 K
- Spatial temperature uniformity: ±0.5 to ±1.5 K
- Temperature change rates:
- Heating: 4.0 K/min
- Cooling: 3.0 K/min
- Maximum heat compensation at +20°C: 4500 W
Specifications for climate tests:
- Temperature range: +10°C to +95°C
- Dew point range: -3°C to +94°C
- Humidity range: 10 to 98% r.H.
- Temporal temperature deviation: ±0.1 to ±0.3 K
Fsdpjyguw Nefx Ag Ajgc
- Spatial temperature uniformity: ±0.5 to ±1.0 K
- Temporal humidity deviation: ±1 to ±3% r.H.
- Max. heat compensation: 500 W
Power supply: 3/N/PE AC 400V ±10% 50Hz
Nominal power: 11.5 kW
Nominal current: 22.0 A
Refrigerant: R-404A
Weight: approx. 840 kg
Type: VC³ 4100
Important buyer information:
The following procedures are carried out on all our chambers prior to sale:
1. Functional checks and replacement of necessary components
2. If required, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (See picture)
(Technical data subject to change and errors excepted!)
For further questions, please feel free to contact us by phone.
Listing
Borken
7,009 km
Temperature test chamber
VötschVT³ 4150/S
Call
Condition: excellent (used), Vötsch
Model: VT³ 4150/S
Vötsch Temperature Test Chamber
Water-cooled
Rated voltage: 3/N/PE AC, 400 V ±10%, 50 Hz
Rated power: 11.5 kW; Rated current: 22.0 A
Change rate (cooling): approx. 3.5 K/min
Change rate (heating): approx. 4 K/min
Fgjdpsyguuzsfx Ag Ajc
Temperature testing
Temperature range: -40°C to +180°C
Layout drawing
External dimensions (W x D x H): approx. 1390 x 2380 x 1995 mm
Test chamber dimensions (W x D x H): approx. 1100 x 1475 x 950 mm
Weight: approx. 1020 kg / 1540 liters
Refrigerant: R 404A
For your safety as the buyer, please note the following information!
The following items are carried out on all chambers offered by us:
1. Functional inspection and replacement of necessary components
2. If needed, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see photo)
(Technical data and information subject to change and errors excepted!)
We are happy to answer further questions by telephone.
Listing
Borken
7,009 km
Climate test chamber with humidity
VötschVC³ 0100 0°C bis + 90°C
Call
Condition: excellent (used), Vötsch
Type: VC³ 0100
Vötsch Climate Test Chamber, Air-Cooled
Internal Test Chamber Dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
Overall Device Dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Test Chamber Volume: 990 litres
Temperature Testing:
Minimum Temperature: -0°C
Maximum Temperature: +90°C
Temperature Change Rate, Cooling: 0.2 K/min
Temperature Change Rate, Heating: 0.5 K/min
Temporal Temperature Deviation: ±0.1 to ±0.5 K
Spatial Temperature Uniformity: ±0.5 to ±1.0 K
Heat Compensation at +20 °C: 350 W
Climatic Testing:
Minimum Temperature: +10°C
Maximum Temperature: +90°C
Dew Point Temperature Range: +4°C to +89.5°C
Humidity Range: 10 to 98% r.h.
Temporal Humidity Deviation: ±1 to ±3% r.h.
Temporal Temperature Deviation: ±0.1 to ±0.3 K
Spatial Temperature Uniformity: ±0.5 to ±1.0 K
Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated Power: 2.3 kW
Fodpfoygut Rsx Ag Aogc
Rated Current: 10 A
Refrigerant: R-404A
Weight: approx. 1400 kg
Important information for you as a buyer:
The following measures are carried out on our offered chambers prior to delivery:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certification
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical details are subject to change and error!)
For further questions, we are happy to assist you by phone.
Listing
Borken
7,009 km
Climate test chamber with humidity
VötschVC³ 4100 990 Liter -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Vötsch climatic test chamber.
Model: VC³ 4100, air-cooled
With a temperature change rate of 3 K/min
Test chamber internal dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
Overall unit dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Chamber volume: 990 liters
Port openings: Ø 125 mm, Ø 50 mm
Temperature test specifications:
Fjdpfx Agjygutwo Aegc
Temperature range: -42°C to +180°C
Temporal temperature deviation: ± 0.1 to ± 0.5 K
Spatial temperature uniformity: ± 0.5 to ± 1.5 K
Temperature change rate:
Heating: 4.0 K/min
Cooling: 3.0 K/min
Max. heat compensation at +20°C: 4500 watts
Climatic test specifications:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Humidity range: 10 to 98% r.h.
Temporal temperature deviation: ± 0.1 to ± 0.3 K
Spatial temperature uniformity: ± 0.5 to ± 1.0 K
Temporal humidity deviation: ± 1% to ± 3% r.h.
Max. heat compensation: 500 W
Power supply: 3/N/PE AC 400V ±10% 50Hz
Rated power: 11.5 kW
Rated current: 22.0 A
Refrigerant: R-404A
Weight: approx. 840 kg
Type: VC³ 4100
For your security as a buyer, please note the following information!
The following points are checked and carried out on all our chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. If needed, fresh filling with legally compliant refrigerant
3. Leak check with certificate
4. After a successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See photo)
(Subject to prior sale, changes and errors in technical data and specifications reserved!)
We are happy to answer any further questions by phone.
Listing
Borken
7,009 km
Climate test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Type: VCS 7034-5
Fsdpoygur Tefx Ag Asgc
Climatic Test Chamber, Water-cooled
Vötsch VCS 7034-5
Test Volume: 335 liters
Specifications for Temperature Testing:
Temperature range: -70 to +180°C
Time-based temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration points: +23°C and +80°C
Specifications for Climate Testing:
Temperature range: +10 to +95°C
Time-based temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Time-based humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration points: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerants: R452A / R-23
Important safety information for buyers:
The following procedures are carried out on our offered chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. Recharging with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful testing, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Subject to technical modifications and errors. All information is non-binding!)
For further questions, please do not hesitate to contact us by phone.
Listing
Maasmechelen
7,091 km
Open Top vertical washing machine
IWSVTL1600-PA4-OT
Call
Year of construction: 2016, condition: used, functionality: fully functional, machine/vehicle number: 160410, Open top washer for 3-12mm
Fedpfx Aewnw Afeg Ajgc
Washing height 1600mm
Listing
Rödermark
6,869 km
Curing oven
HERAEUS-KENDROK 1252 S
Call
Year of construction: 1999, condition: used, machine/vehicle number: 99116961, Technical specifications:
Fsdpfxex E Ubgo Ag Aogc
- Rated / continuous temperature up to 1150 °C
- Infinitely variable temperature control
- Temperature display
- Drive: 400 V / 5 kW
- Internal dimensions approx.: W 160 x H 160 x D 360 mm
- Required space approx.: W 850 x H 700 x D 600 mm
- Weight approx.: 140 kg
Listing
Duxford
7,469 km
Heraeus Sepatech 3743 Centrifuge Rotor
Heraeus Sepatech3743
Call
Condition: used, The Heraeus Sepatech 3743 centrifuge rotor is engineered for efficient and precise sample separation. Built for durability and balance at high speeds, it supports consistent laboratory workflows and is ideal for research, clinical, and industrial centrifugation applications
Fgodpeyx S T Hjfx Ag Ajc
Listing
Budapest
6,101 km
Refrigerated Centrifuge
HeraeusBiofuge Primo R w/ Drum Rotor
Call
Condition: like new (used), The Heraeus Primo R Refrigerated Centrifuge is the perfect centrifuge solution when performing routine analysis in different types of labs. This unit brings you flexibility, efficiency and functionality in a compact, high-performance system all designed to accelerate your sample processes. The Primo R features an imbalance recognition system for improper loading, an EASYcontrol® II control panel for user comfort and user-friendly technology with automatic rotor recognition system. To complete this instrument, we offer a complete selection of rotors and adapters to meet the needs of any lab.
Product Features:
Fgodpsii Ahxjfx Ag Aec
Touch keypad microprocessor control (EASYcontrol II)
Digital display shows all run parameters
Variable speed/RCF/time control
QUICK RUN key for short spins
Choice of 2 acceleration and 9 braking curves for sensitive samples
Memory retains current settings
With optional rotor/adapter combinations, accept tubes from 0.2 to 100mL
Specifications:
Capacity: 400mL (4 x 100mL)
Max RCF: 21,885 x g
Max Speed: 15,000 rpm; adjustable in increments of 10
Max Noise Level:
Listing
Dorsten
7,003 km
Oven - Electric
HERAEUST5042E
Call
Condition: used, degree 250 °c
width . mm
depth . mm
No.8505548
The tech. Data are manufacturer or operator information and therefore non-
binding. We reserve the right to prior sale; Our terms and conditions of sale
apply exclusively.
About us More
than 400 of our own machines in stock
Over 15,000 m² of storage space, 70 t crane capacity
More than 10,000 items and accessories for your workshop
If you are interested in selling machines, production lines, or your business, please contact us. You can find further offers on our website. Tours are possible by appointment.
Fgedpfx Agjyutups Asc
We look forward to your visit.
Your Markus Hirsch Team
Listing
Möttingen
6,739 km
Professional pressure blasters for industry
Mammut 60 liter Druck-Sandstrahlgerätmit Quick-STOP
Call
Condition: new, Our SAPI "Mammut" pressure blasting unit with a 60-liter tank capacity is suitable for all common blasting media. The blasting pressure can be continuously adjusted from 0.1 to 12 bar using the permanently installed pressure regulator. A water separator is also permanently installed on the blasting unit; this separates moisture from the compressed air and prevents the blasting media from clumping due to excessive moisture.
Our safety shut-off device is included for safe operation of the sandblaster. This starts and stops the blasting process by operating the hand lever mounted on the blasting hose.
Included in delivery:
SAPI pressure blasting unit "Mammut 60 L"
1" pressure regulator, permanently mounted
1" water separator, permanently mounted
SAPI safety shut-off
Technical specifications for the pressure blasting unit:
Precisely adjustable from 0.1 - 12 bar
TÜV-tested with certificate
1" fixed piping, internal and external
Rubber-coated metal cone with rubber seal
Generous hand hole
Rubber-coated metal cone with rubber seal
Large hand hole
Rubber-wheeled chassis
Abrasive dosing valve (suitable for all common blasting media)
Capacity 60 l
Total height 1,130 mm
Bowl diameter 360 mm
Total diameter 700 mm
Weight approx. 60 kg
ADVANTAGES OF THE SAPI PRESSURE BLASTING UNIT with safety shut-off
Fast shut-off and start-up times, while complying with the regulations of the professional associations (VBG 48)
Pressure setting Can be precisely adjusted before the actual blasting process, continuously adjustable from 0.1 to 12.0 bar.
Reduced abrasive consumption, as the pressure vessel remains permanently pressurized, thus eliminating unnecessary abrasive run-on.
Upon restart, the full blasting pressure is immediately available at the nozzle and does not need to be slowly built up. This significantly reduces abrasive consumption and significantly reduces wear on the blasting hose.
No moisture (condensate) builds up in the vessel, as the vessel remains constantly pressurized and is not vented and vented with every start and stop. This process also offers other advantages, such as:
Optimal abrasive dosing with a hardened fine dosing valve
Lower compressed air consumption, thus significantly reducing fuel consumption (diesel)
One-person operation, as the blasting pressure is constantly displayed by the vessel pressure and can be easily adjusted on the pressure gauge without prior start-up.
Fgodpfx Agjwc Afhs Aec
No failure-prone components such as control valves, diaphragms, or seals, making it easy to maintain and reliable. Only the blasting hose needs to be checked in the safety shutoff and replaced if necessary.
Listing
Żychlin
6,147 km
Heraeus Primo R laboratory centrifuge
HeraeusBiofuge Primo R
Call
Condition: excellent (used), The Thermo Scientific Heraeus Biofuge Primo R centrifuge enables high-throughput and low-throughput processing with optional rotors and accessories and a maximum speed of up to 15,000 rpm. This compact, high-performance refrigerated centrifuge provides efficient and flexible sample processing. The Primo R features automatic rotor recognition and unbalance detection with uniform temperature control. The Primo R is ideal for small medical laboratories, biochemical and molecular biology research, and routine analysis in industrial laboratories. Typical applications include sedimentation of cells (algae, yeast, bacteria, etc.), sedimentation of cell organelles and cell fragments, preparation of DNA samples and protein precipitates, blood and urine analysis, and centrifugation of standard test series in microliter tubes. This refrigerated centrifuge is equipped with a fixed angle and tiltable rotor. Technical specifications: Voltage: 220-240 V Current: 2.9 A Power: 490 W Maximum centrifuge speed: 15,000 rpm (adjustable in increments of 10) Minimum centrifuge speed: 300 rpm Maximum RFC Weight: 21855 g Temperature range: -9...40°C Noise level at maximum speed: < 60 dB Rotor recognition: automatic Unbalance recognition: electronic Safety features: lid lock and interlock Rotor specification 1: Number: 7591 Type: swinging bucket rotor Maximum speed: 4000 rpm Maximum RCF: 2585 g Maximum capacity: 4 x 100 mL
Fgjdpfjt Eva Ijx Ag Ajc
Listing
Wiefelstede
6,930 km
Drying oven 2.2 kW 300 °C
HeraeusT 6120 100 Liter
Call
Condition: good (used), Drying oven, drying cabinet, chamber dryer oven, warming oven, heating chamber, drying oven, drying cabinet, drying and warming cabinet, universal oven
-Manufacturer: Heraeus, drying cabinet universal oven type T 6120 with viewing window
-Useful space: BTH 550/370/495 mm / 100 liters
Fodpfx Agowbc U Hj Aogc
-Heating power: 2.2 kW
-Nominal temperature: 300°C
-Voltage: 230 V
-Individual components: digital temperature controller, adjustable ventilation flap
-Dimensions: 940/585/H720 mm
-Weight: 72 kg
Listing
Metzingen
6,834 km
Oven - Electric
HERAEUSRL320E
Call
Year of construction: 1985, condition: used, degree 650
working heigth 250 mm
length 250 mm
width 250 mm
depth 450 mm
total power requirement 8 kW
weight of the machine ca. t
dimensions of the machine ca. m
Fgodpfot Hw Tfsx Ag Ajc
Listing
Borken
7,009 km
Testing of lithium-ion batteries
VötschVC³ 4018/S Li-Ion CO/CO
Call
Condition: excellent (used), Vötsch
Type: VC³ 4018/S
Vötsch VC³ 4018/S Climate Test Chamber – Li-Ion CO/CO₂
−42 to +150 °C 400 V Air-cooled
For sale is a temperature and climate test chamber from the renowned German manufacturer Vötsch Industrietechnik GmbH, model VC³ 4018/S, year of manufacture 2012. The unit is specifically equipped for testing lithium-ion batteries and features CO monitoring as well as CO₂ inertization for enhanced operational safety.
Important Note:
Due to these safety features, the test chamber is software-limited to a temperature range of −42 °C to +150 °C.
The chamber is ideally suited for:
- Li-Ion battery testing
- Electronics and assembly testing
- Temperature and climate stress tests
- Development and quality assurance tasks
Technical Data:
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
External dimensions: Width 870 mm x Depth 1550 mm x Height 1800 mm
Test chamber volume: 190 liters
Feed-throughs included as standard:
R1: Ø 125 mm
L1: Ø 50 mm
Data for temperature tests:
Temperature range: -42°C to +150°C
Temporal temperature deviation: ± 0.1 to ± 0.5 K
Spatial temperature uniformity: ± 0.5 to ± 1.5 K
Temperature change rate:
Heating 4 K/min
Cooling 4 K/min
Max. heat compensation: 2300 W
Data for climate tests:
Temperature range: +10 to +95 °C
Dew point range: -3 to +94 °C
Humidity range: 10 to 98 % RH
Temporal temperature deviation: ± 0.1 to ± 0.3 K
Spatial temperature uniformity: ± 0.5 to ± 1.0 K
Temporal humidity deviation: ± 1 to ± 3 % RH
Heat compensation: 400 W
Operating data:
Test chamber lighting: Halogen bulb 2 x 24V, 50W
Fsdpfx Agsx Slm Hj Ajgc
3/N/PE AC 400V ±10% 50 Hz
Rated power: 4.1 kW
Rated current: 14 A
Refrigerant: R-404A
Weight: 470 kg
Important Safety Information for Buyers!
The following servicing steps are performed on our offered chambers in advance:
1. Function check and replacement of necessary components
2. If required, new refill with legally compliant refrigerant
3. Leak test with certification
4. After successful inspection, the chambers undergo a documented test run.
Condition: Used
Scope of delivery: (See image)
(Specifications and technical data are subject to change and errors are excepted!)
If you have further questions, we are happy to assist you by phone.
Listing
Beringen
6,885 km
Hardening furnace
HERAEUSLan 40/50
Call
Condition: good (used), Internal dimensions diametre x depth 430 x 630 mm
Temperature 800°
MARCELS MASCHINEN AG
Fjdpfsw Nnquox Ag Ajgc
Listing
Bockhorn
6,938 km
Single-screw extruder
CINCINNATI PROTON 1-60-30GPROTON 1-60-30 G
Call
Operating hours: 54,000 h, condition: ready for operation (used), functionality: fully functional, CINCINNATI PROTON 60-30G
Screw diameter: 60 mm, L/D = 30
Grooved feed section
Throughput: approx. 450 kg/h PE
Motor (DC drive): 163 kW
Screw speed: max. 221 rpm
Tool zones: 5 pcs + 1 pc for adapter
Melt pressure & temperature sensors included
Fsdpfxoyrihgo Ag Ajgc
Control system: Cincinnati EXc Pro-NT
Cylinder in bimetal design – condition: good
Screw with wear-protection and hardened feed section – condition: good
Dimensions (L x W x H): 2,580 x 1,430 x 1,800 mm
Weight: 2,500 kg
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
7,009 km
Temperature test chamber 335 liters
Vötsch-70°C bis +180°C VTS 7034-5
Call
Condition: excellent (used), Type: VCS 7034-5
Climate Test Chamber Water-Cooled
Test chamber volume: 335 liters
Performance for temperature tests:
Temperature range: -70 to +180°C
Temperature deviation over time: ±0.1 to ±0.5 K
Temperature deviation spatially: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Fgodpfx Agoxufype Asc
Change rate:
Cooling: 3.5 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3,000 W / at -20°C: 3,000 W
Temperature calibration points: +23°C and +80°C
Performance for climate tests:
Temperature range: +10 to +95°C
Temperature deviation over time: ±0.1 to ±0.3 K
Temperature deviation spatially: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Humidity deviation over time: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climatic calibration points: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions:
Width: 580 mm, Depth: 765 mm, Height: 750 mm
External dimensions:
Width: 870 mm, Depth: 1595 mm, Height: 1775 mm
Feedthroughs:
1 x approx. 50 mm Ø, left side
2 x approx. 125 mm Ø, left side
1 x approx. 125 mm Ø, right side
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerant: R404A / R-23
For your security as a buyer, please note the following information:
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical data are subject to change and errors!)
If you have further questions, we are happy to answer them by phone.
Listing
Borken
7,009 km
Climatic chamber
VötschVCS 7034-5
Call
Condition: used, Vötsch
Model: VCS 7034-5
Climatic Test Chamber, Water-Cooled
Test chamber volume: 335 liters
Specifications for temperature testing:
Fsdpfxoxqzbbo Ag Ajgc
Temperature range: -70 to +180°C
Temporal temperature deviation: K ±0.1 to ±0.5
Spatial temperature deviation: K ±0.5 to ±2.0
Temperature gradient: 1 to 4 K
Rate of change:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration values: +23°C and +80°C
Specifications for climate testing:
Temperature range: +10 to +95°C
Temporal temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Temporal humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400W
Climate calibration values: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580mm, Depth 765mm, Height 750mm
External dimensions: Width 870mm, Depth 1595mm, Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10%, 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerants: R404A / R-23
For your safety as a buyer, please take note of the following information!
The following procedures are carried out in advance on all chambers we offer:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. Upon successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see picture)
(Technical specifications subject to change and error)
If you have further questions, we would be happy to answer them by phone.
Listing
Borken
7,009 km
Temperature test chamber 335 liters
Vötsch-70°C bis +180°C VTS 7034-5
Call
Condition: excellent (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50 Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Fsdpfx Ageu H U Two Aogc
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Climatic test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Type: VCS 7034-5
Water-cooled climatic test chamber
Vötsch VCS 7034-5
Fedeuudx Djpfx Ag Aegc
Test chamber capacity 335 liters
Performance for temperature tests
Temperature range -70 to +180°C
Temperature deviation temporal K ±0.1 to ±0.5
Spatial temperature deviation K ±0.5 to ±2.0
Temperature gradient 1 to 4
Rate of change :
Cooling 6.7 K/min
Heating 6.8 K/min
Heat compensation at +20 °C 3000 W / at -20°C 3000 W
Temperature calibration values +23 °C and +80 °C
Performance for climate tests
Temperature range +10 to +95°C
Temperature deviation in time ±0.1 to ±0.3 K
Spatial temperature deviation ±0.5 to ±1.0 K
Temperature gradient 1 to 2 K
Humidity range 10 to 98%
Humidity deviation in time ±1 to ±3%
Dew point range -3 to +94°C
Heat compensation 400W
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 580mm Depth 765mm Height 750mm
External dimensions: Width 870mm Depth 1595mm Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64dB(A)
Cooling water consumption: 1.4m³/h
Refrigerant: R-404A / R-23
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
We make it easier for you to find: "heraeus vötsch vtl 60/60"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month


























































































































































































