Used Corrosion / Condensation Testing Device for sale (21,936)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
7,009 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), Weiss Temperature Shock Test Chamber
Here we offer a temperature shock test chamber.
Weiss Temperature Shock Test Chamber, Water-Cooled
Specification:
Temperature range, hot chamber: +60°C … +220°C
Temperature range, cold chamber: -10°C … -80°C
Hot/cold chamber switching time: 10 sec.
Temperature stability: ±1 K
Dimensions and other data:
External dimensions: Height 1990 mm
Width (without and with door hinge): without… approx. 1820 mm, with… approx. 1850 mm
Depth (without and with test chamber door): without… approx. 900 mm, with… approx. 1155 mm
Dimensions of the lifting platform (test chamber): Height 450 mm, Width 500 mm, Depth 600 mm
Volume: 130 liters
Test chamber load: max. 20 kg
Load on the test chamber floor: max. 20 kg
Cooling water pressure: min. 2 ... max. 6 bar
Max. fuse rating: 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of the device: approx. 65 dB(A)
Refrigeration cascade, water-cooled
Connection values: 3/N/PE/AC 400V ±10% 50Hz / 14.0 kW
Rated current: 26.0 A
Nwsdpfxszd Ulge Alhsh
Refrigerant: R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Test station for adhesive heads included
DÜRR5 Robotergeführte Kleberköpfe
Call
Condition: excellent (used), Here, we offer you a DÜRR testing station for adhesive applicators.
DÜRR testing station for adhesive applicators, including (5 robot-guided adhesive applicators).
DÜRR testing station (custom-built by Dürr) for the automotive industry.
Weight: 1200 kg
Type: DÜRR testing station for adhesive applicators
Condition: used
Scope of delivery: (See image)
Nwsdozd Ukvepfx Alheh
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have over the phone.
Listing
Metzingen
6,834 km
Gear Testing Machine
KLINGELNBERGPFSU 2500
Call
Condition: used, Year of construction: 1980, max. wheel diameter 2500 mm
gear width 0 mm
max. module 34
min. module 1
total power requirement ca. 15 kW
weight of the machine ca. 15 t
dimensions of the machine ca. 4,20 x 2,00 x 2,90 m
Extra große ZR-Prüfmaschine, Gegenhalter
Nodpfst Hw Aaox Alhswh

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Metzingen
6,834 km
Gear Testing Machine
KLINGELNBERGPFSU 1600
Call
Condition: used, Year of construction: 1975, max. wheel diameter 160 - 1.600 mm
Njdpjt Hwptjfx Alhjwh
gear width 250 mm
max. module 20
min. module 1,5
total power requirement 1 kW
weight of the machine ca. 3 t
dimensions of the machine ca. m
Listing
Metzingen
6,834 km
Gear Testing Machine
MAHR894 C
Call
Condition: used, Year of construction: 1980, max. wheel diameter 400 mm
gear width NA mm
max. module 5
min. module
Nodpfst Hw Ebox Alhewh
total power requirement kW
weight of the machine ca. t
dimensions of the machine ca. m
Manual Two Flank Gear Tester
Listing
Borken
7,009 km
Environmental test chamber -70°C to +180°C humidity
ThermotronSM-8-8200
Call
Condition: excellent (used), Here we offer you a Thermotron environmental test chamber.
Thermotron environmental test chamber, water-cooled
Working area volume: 227 liters
Temperature uniformity: All models 0.7°C
Temperature range: -70°C to +180°C
Temperature control tolerance: All models 0.3°C
Shipping weight: approx. 400 kg
Internal dimensions: Width 610 mm x Depth 610 mm x Height 610 mm
External dimensions: Width 890 mm x Depth 1240 mm x Height 1850 mm
Humidity range: All models 10% to 98% RH
Humidity control: All models 2.5% RH
Heating time in minutes -65º to 71ºC: 17
Heating time in minutes -65º to 180ºC: 43
Heating time in minutes -40º to 85ºC: 16
Electrical requirements in full load amps 230/3/60: 19
Electrical requirements in full load amps 230/1/60: 25
Electrical requirements in full load amps 220/1/50: 27
Cooling time in minutes 85º to -40ºC: 32
Nodpfx Alozd Snrohswh
Cooling time in minutes 71º to -65ºC: 54
Cooling time in minutes 180º to -65ºC: 72
Compressor size: (2) -2 Hp
Operating voltage: 400V 16.7 A
Type: SM-8-8200
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by phone.
Listing
Borken
7,009 km
Emissions test chamber
WEISSWT 5,1'/ + 18-45
Call
Condition: excellent (used), Weiss
Here, we offer a Weiss emission test chamber.
Mini - SHED for diurnal loss measurements
Test chamber dimensions: Width 1600 mm x Depth 2140 mm x Height 2150 (usable 1600) mm
Housing dimensions: Width 1760 mm x Depth 3100 mm x Height 2790 mm
Maximum floor load: 250 kg
Operating temperature range: +18 °C ... +45 °C (at higher temperatures, SHED operation is only possible without a Tedlar bag)
Temperature range: +18 °C ... +45 °C
Temperature stability: ≤ ±1 K (over time)
Temperature change rate (heating and cooling): approx. 0.5 K/min, without test specimen
Duct connection (air inlet and outlet): ∅ 80 mm, in the rear wall of the chamber
Shut-off valve, gas-tight (air inlet and outlet): ∅ 80 mm, gas-tight, pneumatic operation; scope of supply: connecting flange of the shut-off valve
Cooling water consumption: approx. 0.8 m3/h
Voltage: 230/400 V; 3-phase + N + PE; 50 Hz
Rated power: 4.1 kW Rated current: 14.0 A
Weight: approx. 2500 kg
Type: WT 5.1'/ + 18-45
Condition: used
Njdpfozd Slkex Alhewh
Sale from our location
Scope of supply: (Only the Weiss emission test chamber WT 5.1'/ + 18-45 Mini-SHED)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
Listing
Borken
7,009 km
Burst test bench
LindnerAGB Berstprüfstand TMM4
Call
Condition: excellent (used), Lindner Burst Test Stand
We offer a Lindner burst test stand here.
AGB Burst Test Stand TMM4
Technical Data:
AGB Burst Test Stand TMM4
Year of manufacture: 2015
Rated voltage: 3/N/PE AC 400V
Rated power: 5.5 kW
Chamber temperature range: RT ... 180°C
Medium temperature range: RT ... 135°C
Pressure range: 0 ... 5 bar
Njdpfozd Sivox Alhewh
Compressed air supply: 6-8 bar
Test medium: Glycol / Water
Heat transfer fluid: Fragoltherm Q-HTF
Dimensions: Length 2150 mm x Width 1050 mm x 2160 mm
Operating voltage: 3/N/PE AC 400V +/-10% 50Hz
Power: 5.5kW
Rated current: 8A
Fuses: 16A
Control voltage: 24VDC
PLC system: S7-1215 DC/DC/RLY
The following items are required for commissioning the burst test stand:
Pump, cooling tower & fire alarm control panel – these are not included.
Type: AGB Burst Test Stand TMM4
Weight approx. 705 kg
Condition: used
Scope of supply: (See image)
(Subject to changes and errors in technical data and specifications!)
We will be happy to answer any further questions you may have by telephone.
Listing
Borken
7,009 km
Temperature test chamber
Heraeus VötschVTS 7033
Call
Condition: excellent (used), Heraeus Vötsch Temperature Test Chamber
Here we offer a Heraeus Vötsch temperature test chamber.
Vötsch Temperature Test Chamber VTS 7033, Water-Cooled
Temperature range: -70°C to +180°C
Nwodpfx Aozd Sf Dolhjh
Temporal temperature deviation: ± 0.5 K
Spatial temperature deviation: ± 1.5 K
Heating rate: 7.5 K/min
Cooling rate: 6.5 K/min
Test chamber dimensions: Width 825 mm x Depth 800 mm x Height 870 mm
Housing dimensions: 1080 mm x 1710 mm x 1950 mm
Side openings: 12 cm and 13 cm
Voltage: 400V +6/-10%, 3/N, 50Hz
Rated power: 9.5 kW, Rated current: 22 A
Refrigerant: R404A / R23
Approx. 570 liters, Weight: 580 kg
For your safety as a buyer, please note the following information:
The following steps are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Type: VTS 7033
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Temperature test chamber
RS-SimulatorenTS 150/75
Call
Condition: excellent (used), RS Simulators
Nwodjzd Sfqspfx Alhjh
Here we offer a temperature test chamber.
Temperature Test Chamber, Water-Cooled
Temperature range: -70°C to +180°C
Time deviation: ±1 K according to DIN 50011 in an empty test chamber
Average heating time: approx. 3 K/min (according to DIN 50011 Part 12)
Average cooling time: approx. 3 K/min (according to DIN 50011 Part 12)
Test chamber dimensions: Width 530 mm x Height 530 mm x Depth 530 mm
External dimensions: Width approx. 900 mm x Height approx. 1800 mm x Depth approx. 1400 mm
Total power: approx. 6 kVA
Current consumption: 12 A
Main fuse: 3 x 16 A, slow-blow
Connection voltage: 3x400V/N/PE 50Hz
Weight: approx. 600 kg
Type: TS 150/75
Refrigerant: R404A / R23
Condition: used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data and specifications!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), Weiss Temperature Shock Test Chamber
Here we offer a temperature shock test chamber.
Weiss Temperature Shock Test Chamber, Water-Cooled
Njdpfx Aezd Sfdslhowh
Specifications:
Temperature range, hot chamber: +60°C … +220°C
Temperature range, cold chamber: -10°C … -80°C
Switching time, hot/cold chamber: 10 s
Temperature stability: ±1 K
Dimensions and other data:
External dimensions: Height 1990 mm
Width (without and with door hinge): without... approx. 1820 mm, with... approx. 1850 mm
Depth (without and with test chamber door): without... approx. 900 mm, with... approx. 1155 mm
Dimensions of the lifting platform (test chamber): Height 450 mm, Width 500 mm, Depth 600 mm
Volume: 130 liters
Test chamber load: max. 20 kg
Load on the test chamber floor: max. 20 kg
Cooling water pressure: min. 2 ... max. 6 bar
Max. fuse rating: 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of the device: approx. 65 dB(A)
Refrigeration cascade, water-cooled
Connection values: 3/N/PE/AC 400V ±10% 50Hz /18.7 kW
Rated current: 26.0 A
Refrigerant: R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Temperature shock test chamber
Weiss130 Liter TS 130 *
Call
Condition: excellent (used), Here we offer you a temperature shock testing chamber.
Weiss temperature shock testing chamber, air-cooled
Specification:
Temperature range, warm chamber: +60°C … +220°C
Temperature range, cold chamber: -10°C … -80°C
Changeover time, warm/cold chamber: 10 s
Temperature stability: ±1 K
Dimensions and other data:
External dimensions: height 1990 mm
Width (without and with door hinge): without… approx. 1820 mm, with… approx. 1850 mm
Depth (without and with test chamber door): without… approx. 900 mm, with… approx. 1155 mm
Dimensions of the lifting platform (test chamber): height 450 mm, width 500 mm, depth 600 mm
Volume: 130 liters
Test chamber load: max. 20 kg
Load on the test chamber floor: max. 20 kg
Cooling water pressure: min. 2 ... max. 6 bar
Max. fuse rating: 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of the device: approx. 65 dB(A)
Nwodpezd Sd Hefx Alhjh
Refrigeration cascade, water-cooled
Connection values: 3/N/PE/AC 400V ±10% 50Hz /14.0 kW
Rated current: 26.0 A
Refrigerant: R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), Weiss Temperature Shock Test Chamber
Here we offer you a temperature shock test chamber.
Weiss Temperature Shock Test Chamber, Air-Cooled
(Compressor has been replaced!)
Nsdpozd Sdyofx Alhjwh
Specifications:
Temperature range, hot chamber: +60°C … +220°C
Temperature range, cold chamber: -10°C … -80°C
Hot/cold chamber switching time: 10 s
Temperature stability: ±1 K
Dimensions and other data:
External dimensions: Height 1990 mm
Width (without and with swivel arm): without... approx. 1820 mm, with... approx. 1915 mm
Depth (without and with test chamber door): without... approx. 900 mm, with... approx. 1155 mm
Dimensions of the lifting platform (test chamber): Height 450 mm, Width 500 mm, Depth 600 mm
Volume: 130 liters
Test chamber load: max. 20 kg
Load on the test chamber floor: max. 20 kg
Cooling water pressure: min. 2 ... max. 6 bar
Max. fuse rating: 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of the device: approx. 65 dB(A)
Connection values: 3/N/PE/AC 400V ±10% 50Hz / 14.0 kW
Rated current: 26.0 A
Refrigerant: R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by phone.
Listing
Borken
7,009 km
Climatic test chamber
Feutron3702/06
Call
Condition: excellent (used), Feutron
Type: 3702/06
Water-cooled climate test chamber
Technical data:
Nominal volume of test chamber: 2.0 m³
Dimensions: Test chamber exterior, with humidifier console
Width: 2970 mm, Height: 2370 mm, Depth: 1530 mm
Rear wall
Minimum insertion dimensions: Width: 2970 mm, Height: 2390 mm, Depth: 1550 mm
Test chamber: Width: 2000 mm, Height: 1000 mm, Depth: 1000 mm
Nsdpjzd Sdmefx Alhswh
Door: double-leaf, clear opening width 2000 mm, height 1000 mm
Viewing window, heated, 2 pieces, width 500 mm, height 600 mm
Feed-through opening, 1 piece, left side wall, diameter 75 mm
Temperature range: -40...100°C
Climate range: 10...95°C
Temperature difference, time-dependent ≤ ± 0.5...± 1.0 ΔN/K
Rate of change measured in the supply air, without load
Cooling up to 2.0 on average K/min
Heating up to 2.0 on average K/min
Humidity range: 10...95 % RH
Humidity difference, time-dependent ≤ ± 3.0 % RH
Dew point range, intermittently up to -5...95°C
Refrigeration system: water-cooled, semi-hermetic Bitzer system
Refrigerant: R507 (Μ-Κ1)
Climate and dryer refrigeration system: air-cooled / hermetic system
Refrigerant: R134a (Μ.ΚΚ)
Power supply:
Electrical connection: 400V 3/N/PE.AC, 50Hz
Power plug: CEE 5-pin, 32 A, with 5.0 m cable
Max. simultaneous power requirement: 10.0 kW
Supply line fuse: 3x 25, Char, C A
Protection class: IP20
Weight: 1300 kg
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Climate test chamber with humidity control
Feutron3707/06 Temp. -40°C bis 150°C
Call
Condition: excellent (used), Here we offer a Feutron climate test chamber.
Feutron Climate Test Chamber
Temperature
Temperature range: -40...90°C
Climatic range (without heat load): 10...85°C
Temporal temperature deviation during temperature operation: ≤ ± 0.5 K/min
Temporal temperature deviation during climatic operation: ± 1.0... ± 1.5 K/min
Change rates
Heating: avg. 2.0 K/min
Cooling: avg. 2.0 K/min
Standard IEC 1646 is achievable with testing, solar modules up to max. 160kg weight and nonlinear ramps (setpoint jump)
Drying
Air drying: condensation drying
Humidity
Air humidification: steam humidification
Humidity range: 10...95 % r.h.
Temporal humidity deviation: ≤ ± 3.0... ±5.0 % r.h.
Dew point range: 8...80.9°C
Test Chamber
Test chamber volume: 7.0 m³
Dimensions
Internal dimensions: Width 1500 mm x Height 2250 mm x Depth 2000 mm
Swing door DIN right, heated, Width 900 mm x Height 2100 mm
Nedpszd Sdgsfx Alhowh
Observation window, heated, with blackout shutter and lockable: Width 500 mm x Height 600 mm
Feedthrough: 2x, right front side, Ø 75 mm
Irradiation unit, test chamber
Opening: 4x in left side wall for SC 2500, each 850 x 700 mm
Irradiated area when using SC 2500: 1200 x 1200 mm
Radiation intensity at 1.0 m wall distance: 1000 ± 10% W/m²
Lighting: 1x halogen lamp, 200W
Refrigeration system: Bitzer compressor, semi-hermetic, 2-stage, air cooled
Condenser: split condenser (outdoor installation, winter control)
Refrigerant: R507 / R23
Temperature control system
Coolant medium Tyfocor / water
Mixing ratio 50/50%
Coolant density: 1.072 kg/dm³
Filling quantity: approx. 80 dm³
Pyranometer
Temperature range: -40...150°C
Max. radiation absorption: 4000 W/m²
Spectral range (50% points): 305...2800 nm
Sensitivity (nominal): 7 µV/W/m²
Power supply, test chamber
Mains connection: 400V, 3/N/PE, AC, 50Hz
Connection type: hardwired
Max. simultaneous power demand: approx. 32.0 kW
Supply fuse: 3 x 63, Char C (A)
Power supply, SolarConstant
Mains connection: 400V, 3/N/PE, AC, 50Hz
Connection type:
Max. simultaneous power demand: approx. 30.0 kW
Supply fuse: 3 x 63, Char C (A)
Overall external dimensions of the test cell including: equipment room/control cabinet and control cabinet for SolarConstant 2500
External dimensions equipment room: Width 3440 mm x Height 2580 mm x Depth 2950 mm
/control cabinet: Width 2200 mm x Height 1830 mm x Depth 1100 mm
External dimensions condenser, split: Width 900 mm x Height 950 mm x Depth 2000 mm
Weight test chamber (total): approx. 2700 kg
Condenser empty weight: 153 kg
Weight: 2700 kg
Type: 3707/06
Condition: used
Scope of delivery: (see picture)
(Technical data and information are subject to change and errors!)
For further questions, we are happy to assist you by phone.
Listing
Borken
7,009 km
Shaft measuring device
MahrHelio-Pan II 700
Call
Condition: excellent (used), Mahr
Here we offer you a Helio-Pan II.
Max. workpiece weight 30 kg at a center height of 100 mm
80 kg at a center height of 150 mm
Measuring range, length: 0 mm to 700 mm
Nodszd R U Depfx Alhswh
Measuring range, outer diameter: 0 mm to 120 mm
Max. measurable throw: 100 mm
Center height: 100 mm
Measuring blades/probe and caliper: 1 mm x 5 mm
Dimensions (W x D x H)
Machine: 2060 mm x 920 mm x 1750 mm
Controller box: 600 mm x 800 mm x 2200 mm
Weight: approx. 900 kg
Electrical power: 230 V / 1200 W / 50 Hz
Air pressure: 6 bar
Type: Helio-Pan II 700
Scope of delivery: (See image)
We will gladly answer any further questions you may have over the phone.
Written orders can be placed via email or fax.
Listing
Borken
7,009 km
Shock test chamber
HeraeusHT 7012 S2
Call
Condition: excellent (used), Here, we offer a shock test chamber.
Water-cooled temperature shock test chamber
Two-chamber design
Warm chamber:
Temperature control in the warm chamber ranges from +50°C to +220°C
Temporal temperature deviation in the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Nedpfxezd R Uwo Alhewh
Temperature change rate:
Heating: 11 K/min
Cold chamber:
Temperature control in the cold chamber ranges from -65°C to +70°C
Temporal temperature deviation in the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate:
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Temperature range, warm chamber: +50°C to +220°C
Temperature range, cold chamber: -65°C to +70°C
Test chamber dimensions: Width 470mm, Depth 650mm, Height 410mm
External dimensions: Width 930mm, Depth 2115mm, Height 1970+mm
Rated power: 10 kW
Rated current: 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant: R404A / R23
Operating hours: 27,903 hours
Weight: 1000 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated instruments.
Type: HT 7012 S2
Condition: used
Scope of supply: (See image)
(Changes and errors in the technical data are subject to change!)
We are happy to answer any further questions you may have by phone.
Listing
Borken
7,009 km
Climate test chamber 280 liters
FeutronKPK 200 Typ: 3416/16 +5 °C bis +100 °C
Call
Condition: excellent (used), We offer a climate test chamber for sale.
Air-cooled
Test chamber nominal volume: 280 liters
Dimensions:
External dimensions of the test chamber: 1500 x 2040 x 1075 mm
With fan motor and door removed: 1500 x 1940 x 925 mm
Test chamber: 720 x 690 x 560 mm
Door, clear opening: 720 x 690 mm
Viewing window, heated: 500 x 600 mm
Temperature range:
+5 to +100 °C
Heating rate: 4.0 K/min
Cooling rate: 0.6 K/min
Climate range: +10 to +95 °C
Humidity range: 10 to 95 % RH
Humidity change rate: ≤ ± 3.0
Water connection for humidifier: Tap water or distilled water, 20-liter reservoir
Power connection: 400 V 3/N/PE, AC, 50 Hz
Maximum power consumption: 6.3 kW
Weight: 500 kg
Type: 3416/16
Refrigerant: R134a
Nwjdpozd R T Tefx Alhsh
For your peace of mind as a buyer, please note the following:
The following steps are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated instruments.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
Listing
Borken
7,009 km
Temperature test chamber 335 liters
VötschVTS 7034-5 -70°C bis +180°C
Call
Condition: excellent (used), Heraeus Vötsch Temperature Test Chamber
Here we offer you a Heraeus Vötsch temperature test chamber.
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
Temperature range: -70°C to +180°C
Temperature deviation (temporal): ±0.1 to ±0.5 K
Temperature deviation (spatial): ±0.5 to ±2.0 K
Temperature change rate (cooling): 5.0 K/min
Temperature change rate (heating): 6.5 K/min
Heat compensation at +20°C: 3000 W
Heat compensation at -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Nwodpszd R Tgofx Alhoh
Test chamber volume: 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW, Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Side feedthrough: 5.5 cm / 12.5 cm
Chamber is water-cooled
Refrigerant: R 452A and R 23
Weight: approx. 570 kg
Type: VTS 7034-5
For your security as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Temperature test chamber
WEISSWT1-600/70
Call
Condition: excellent (used), Weiss Temperature Test Chamber
Here we offer you a Weiss temperature test chamber.
Weiss Temperature Test Chamber, Water-Cooled
Technical Data:
Test chamber designation: WT1-600/70
External dimensions without hinges and door closure
Height 1980 mm, Width 1085 mm, Depth 1655 mm
Internal dimensions
Height 950mm, Width 800mm, Depth 800mm
Test chamber volume: approx. 600 liters
Cold/heat operation: -70 to 180°C
Temperature change per unit of time
Cooling: approx. 2.5 K/min
Heating: approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 9.1 kW
Rated current: 19 A
Permissible weight of test specimens
Total load of the shelf supports: 80 kg
Refrigerant: R 404A + R23
Weight: 600 kg
Type: WT1-600/70
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
Nwedpszd R Svofx Alhoh
We will gladly answer any further questions you may have on the phone.
Listing
Odesa
5,211 km
Turbo Test Bench
VTM GroupTURBO-BOOST-TEST
Call
Condition: new, TURBO-BOOST-TEST turbocharger boost testing bench allows for professional turbocharger calibration and performance evaluation. The test bench can be used in turbine tuning and refinement, in the manufacture of hybrid turbines, to test changes in turbine performance after tuning.
Our test benches are advanced systems for turbocharger tuning and testing in dynamic mode. Its provide turbocharger testing under near realistic operating conditions, ensuring full process control and detection of any potential problems, including oil leaks.
HIGHLIGHTS
• Complete finish testing and tuning of automotive turbochargers for engines up to 3 liters
• Dynamic turbocharger testing
• Installation on the regular surfaces of fastening
• Running in and check on an oil leak
• Tuning of electronically driven turbos is done by connecting to an external tester ATP-3000
• Installation of turbochargers of any design
KEY FEATURES
• More than 2000 turbo references database
• Calculate turbocharger performance;
• Plot supercharging vs. inlet and outlet flow graph;
• Generating the resulting graph;
• Testing of actuator performance: vacuum, pneumatic and electric types;
• Diagnosis of servo-drives of electric actuators (optional);
• All measurements are done in real time.
• Calibration of the test bench before starting work
• N75 valve testing function
• Built-in blower pump to create a constant airflow
• Self-developed Boost Test software.
• Creation and printing of reports on the tuning process.
• Self-diagnostics
SPECIFICATIONS
Maximum rotor speed 99 000 rpm
Nwedpottg S Uofx Alhsh
Maximum air flow rate of compressor 110 m³/min
Maximum pressure of compressor 900mbar
Maximum vacuum created by the vacuum pump -800mbar
Power supply 380V, 3Ph, 50Hz
Power input 6 kW
Dimensions 1330 х 770 х 1440 mm
Weight 265 kg
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
7,009 km
Temperature test chamber
WEISSWT-600/70
Call
Condition: excellent (used), Weiss Temperature Test Chamber
Here we offer a temperature test chamber.
Weiss Temperature Test Chamber, Water-Cooled
Technical Data:
Test chamber designation: WT-600/70
External dimensions with hinges and door lock:
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock:
Height 1995 mm, Width 1000 mm, Depth 1660 mm
Internal dimensions:
Height 950 mm, Width 800 mm, Depth 800 mm
Test chamber volume: approx. 600 liters
Cold / heat operation: -70°C to 180°C
Temperature change per unit of time:
Cooling down: approx. 2.5 K/min
Heating up: approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 9.1 kW
Rated current: 19 A
Fuse (customer-supplied): 32 A slow-blow
Permissible weight of test specimen:
Total load of the shelf supports: 80 kg
Test chamber floor: 80 kg, insert shelf: 40 kg
Refrigerant: R 404A/R23
Weight: 675 kg
Type: WT-600/70
For your safety as a buyer, please note the following information!
Nwedpfozd R Drox Alheh
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and information are subject to change!)
We are happy to answer any further questions you may have by phone.
Listing
Borken
7,009 km
Shock test chamber
HeraeusHT 7012 S2
Call
Condition: excellent (used), Heraeus Shock Test Chamber
We offer a shock test chamber here.
Temperature shock test cabinet, water-cooled
Two-chamber design
Warm chamber:
The temperature control of the warm chamber ranges from +50°C to +220°C
Temporal temperature deviation in the center of the usable space ± 1 K
Spatial temperature deviation ± 2 K
Temperature change rate
Heating 11 K/min
Njdezd R Azjpfx Alhjwh
Cold chamber:
The temperature control of the cold chamber ranges from -65°C to +70°C
Temporal temperature deviation in the center of the usable space ± 1 K
Spatial temperature deviation ± 2 K
Temperature change rate
Heating 2 K/min
Cooling 3 K/min
Test chamber volume 125 liters
Temperature range, warm chamber +50°C to +220°C
Temperature range, cold chamber -80°C to +70°C
Test chamber dimensions: width 470mm, depth 650mm, height 410mm
External dimensions: width 930mm, depth 2115mm, height 1970+mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant R404A / R23
Weight: 1000 kg
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Type: HT 7012 S2
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications are reserved!)
We will be happy to answer any further questions you may have by phone.
Listing
Borken
7,009 km
Temperature test chamber, explosion-proof
CTST-30/950 Ex/I
Call
Year of construction: 2011, condition: excellent (used), CTS
Type: T-30/950 Ex/I
CTS Temperature Test Chamber, Explosion-Proof
Control – 32-bit controller
LCD control panel
Digital display for set and actual values
Numerical input of set values
Error messages in plain text
RS 232 interface
Free switching channels for product-side test specimen activation
Temperature Testing:
Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
Heating: 2 K/min
Cooling: 1.5 K/min down to -10°C
Thermal radiation: approx. 1000 W at +20°C
approx. 200 W at -25°C
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with a large flow rate of N2 until the
o2 content drops below 3%. Then, it switches to a base flow amount (approx. 10% of the large flow rate).
The nitrogen flow for the base amount is measured and displayed using a flowmeter and monitored via a limit switch.
O2 monitoring continuously extracts gas from the test chamber via a flame arrestor and passes it over an O2 sensor which checks the residual oxygen content of the extracted air.
Afterwards, the gas is returned to the test chamber via a second flame arrestor.
The extraction pump is monitored by a volumetric flow meter. Additional details can be found in the Dräger user manual in the appendix.
The gas system is currently deactivated!
All technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without irradiation, and without additional equipment.
Dimensions:
Test chamber volume: 950 liters
Test chamber dimensions: Height approx. 700 mm / Width approx. 900 mm / Depth approx. 1500 mm
External dimensions: Height approx. 2400 mm / Width approx. 1270 mm / Depth approx. 3125 mm
Operating data:
Electrical connection: 400V +6/-10 %, 3/N, 50 Hz
Nominal power: 21.6 kW
Nsdpfezd Rzwex Alhjwh
Rated current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, R 1/2" inner thread
Sound pressure level:
Listing
Borken
7,009 km
Vibration test system
RMSSW 3006 mit TGA 1500
Call
Condition: excellent (used), RMS Electrodynamic Vibration Test System
Vibration Exciter SW 3006+
Power Amplifier TGA 1500
Technical Data:
Sine: 3.7 kN
Random: 3.7 kN
Shock: 3.7 kN
Stroke pk-pk: 26 mm
Velocity: 0.9 m/s
Acceleration: 80 g
Nwjdjzd Rvzjpfx Alheh
Cooling: air-cooled
Condition: used
Untested! Testing was not possible
Scope of delivery: (see picture)
(Changes and errors in the technical data may apply!)
We are happy to answer further questions by phone.
We make it easier for you to find: "corrosion / condensation testing device"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month