Used Mytron Temperature Cabinet T2240 Temperature Range –40°C To +100°C, 2240 Liters for sale (89,247)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Success:
Your message has been sent.
Listing
Borken
7,009 km
Mytron temperature cabinet T2240 temperature range –40°C to +100°C, 2240 liters
mytronTemperaturschrank
Call
Condition: used, mytron
Type: T2240
Water-cooled temperature chamber
Technical data:
External dimensions: Width 1435 mm, Height 1955 mm, Depth 2590 mm
Dimensions of the test chamber: Width 1050 mm, Height 1400 mm, Depth 1600 mm
Volume of the test chamber: approx. 2240 l
Cable feed-through opening:
2 x 100 mm on the right
2 x 100 mm on the left
Temperature range: -40 °C to +100 °C at 23 °C ambient temperature
Temporal temperature stability: +/- 0.5 °K
Spatial temperature stability: +/- 1.0 °K
Cooling: Water cooling,
Inlet and outlet 1" internal thread
Cooling water shut-off via solenoid valve when the unit is OFF
Fault indication in case of refrigeration machine failure
Cooling water consumption: Inlet temperature approx. 15 °C, approx. 15 l/min,
Outlet temperature approx. 22 °C (approx. 27 °C in continuous cooling)
Mains connection: 3NPE AC 50 Hz 400 V, 32 A CEE plug
Power consumption: approx. 6.5 kVA
Fuses: 3 x 20.0 AT, 3 x 10.0 AT
Lighting: 25 watts each on the left and right sides of the test chamber
Exhaust connection: DN 100 mm plug-in system
Safety device: Electronic overtemperature protection, permanently set
Flue gas monitoring with audible alarm
Viewing window: Five-pane glazing 130 x 360 mm
Refrigerant: R 404 A, approx. 10 kg
Weight: approx. 850 kg
Condition: used
Scope of delivery: (See picture)
Nwsdpfxozizg Uj Airjn
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Weiss temperature chamber WT3-1000/40, 990 liters, temperature range -40°C to +180°C
WeissTemperaturprüfschrank
Call
Condition: used, Weiss
Type: WT3-1000/40
Weiss temperature testing cabinet with S!MCON / 32 control, water-cooled
Control panel: "Touch Panel"
All control and operating commands can be initiated on the "Touch Panel" control panel by simply touching the function symbols.
Adjustable feet
To compensate for uneven floors and to ensure sufficient ventilation of the machine, the testing cabinet is equipped with adjustable feet.
Feedthroughs
The testing cabinet is equipped with feedthroughs on the right and left sides. These allow measuring cables and testing equipment to be routed into the testing chamber.
Feedthroughs installed as standard
R1: 125 mm
L1: 50 mm
Testing chamber volume: approx. 990 liters
Testing chamber dimensions: Height 950 mm, Width 1100 mm, Depth 950 mm
External dimensions: Height 2000 mm, Width 1415 mm, Depth 2105 mm
Data for temperature tests:
Temperature range: -40 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Temperature deviation spatially: ± 0.5 to ± 1.5 K
Temperature change rate
Heating: 4.0 K/min
Cooling: 3.0 K/min
Maximum heat compensation: 4500 W
Data for operation:
Testing chamber lighting: Halogen bulb 2x 24V, 50W
Rated voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Rated current: 22.0 A, Rated power 11.5 kW
Fuse, to be provided by the customer: 32 A, slow-blow
Sound pressure level approx.
measured at a distance of 1 m from the front, 1 m height: 56 dB(A)
Refrigerant: R-404A
Njdozgbt Nspfx Airewn
Weight: 840 kg
For your safety as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have on the phone.
Success:
Your message has been sent.
Listing
Borken
7,016 km
Feutron TPK 3403/125 temperature test chamber -40 to +100°C temperature test cabinet
FeutronTPK 3403/125
Call
Condition: used, Feutron Temperature Test Chamber -40 to +100°C
The Feutron TPK 3403/125, due to its robust design, is a reliable workhorse for standardized temperature tests.
The main application areas for this model are:
1. Electronics and Component Testing
This is the most common application. It involves testing how components react to extreme temperatures:
Functional testing: Does the circuit board still function flawlessly at -40 °C or +150 °C?
Burn-in tests: Artificial aging of components through continuous operation at high temperatures to provoke early failures.
2. Material Testing
Investigation of physical changes in materials:
Brittleness: Do plastics or rubber seals become brittle in the cold?
Deformation: Do composite materials warp in the heat?
Nwsdpfxjy Nynae Airon
Storage tests: How stable do chemical substances or adhesives remain over long periods at a constant temperature?
3. Quality Assurance (QA)
Sampling inspection: Tests carried out during series production to ensure that the production process meets the specified temperature ranges.
Standard testing: Performing tests according to common industry standards (e.g., DIN EN 60068), which specify certain temperature profiles.
4. Research & Development
Prototyping: Testing new housing designs or materials under controlled thermal conditions before mass production.
Manufacturer: Feutron
Type: TPK 3403/125
Temperature range: -40 to +100°C
Refrigeration unit: Air-cooled condenser
Temperature stability: approx. ±0.1 to ±0.5 K
Usable volume: approx. 125 liters
Refrigerant: R22
Operating overpressure: 23 bar
Power connection: 220/280V-3-50Hz
Supply line fuse: 25 A
Protection class: IP 20
Weight: 480 kg
“Everything from a single source: We will gladly offer you suitable bank financing for your project.”
More items - new and used - can be found in our shop!
International shipping costs on request!
Success:
Your message has been sent.
Listing
Borken
7,009 km
Weiss temperature chamber WT11-1000/40, temperature range -40°C to +180°C, 990 liters
WeissWT11-1000/40
Call
Condition: used, Weiss
Type: WT11-1000/40
Nwjdezfzamopfx Airsn
Weiss temperature chamber, air-cooled, with Weiss condenser cooler
Test chamber volume approx. 990 liters
Data for temperature tests:
Temperature range -40°C to +180°C
Temporal temperature deviation in the center of the usable space ± 0.1 to ± 0.5 K
Spatial temperature deviation ± 0.5 to ± 2.0 K
Temperature gradient (according to IEC 60068-3-5) 1 to 4 K
Temperature change rate (according to IEC 60068-3-5)
Heating 4 K/min
Cooling 3 K/min
Heat compensation max. 4500 W
Feedthroughs installed as standard
R1: NW 125 mm
L1: NW 50 m
Dimensions:
Test chamber dimensions: Width 1100 mm x Depth 950 mm x Height 950 mm
Housing dimensions: Width 1390 mm x Depth 1525 mm x Height 1995 mm
Maximum load (evenly distributed over the area) of the test chamber floor 150 kg
Per insert shelf 50 kg
Total load of the shelf supports 100 kg
Data for operation:
Test chamber lighting: Halogen bulb 24V, 50W
Rated voltage 3/N / PE AC 400 V ± 10% 50 Hz
Rated power 11.5 kW
Rated current 22 A
Heat dissipation water-cooled test cabinets max. heat dissipation to the environment 1.3 kW
Noise measurement:
Sound pressure level approx. 64 dB(A)
Refrigerant: (converted to R-452a)
Weight: approx. 840 kg
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Weiss Temperature Chamber WT11-1000/70/5 Temperature range: -70°C to +180°C, 990 liters
WeissWT11-1000/70/5
Call
Condition: used, Weiss
Type: WT11-1000/70/5
Weiss temperature chamber, air-cooled, with Weiss condenser cooler
Test chamber volume approx. 990 liters
Data for temperature tests:
Temperature range -70°C to +180°C
Temporal temperature deviation in the center of the usable space ± 0.1 to ± 0.5 K
Spatial temperature deviation ± 0.5 to ± 2.0 K
Temperature gradient (according to IEC 60068-3-5) 1 to 4 K
Temperature change rate (according to IEC 60068-3-5)
Heating 5 K/min
Cooling 5 K/min
Heat compensation max. 2750 W
Feedthrough installed as standard
R1: NW 125 mm
L1: NW 50 m
Dimensions:
Test chamber dimensions: Width 1100 mm x Depth 950 mm x Height 950 mm
Housing dimensions: Width 1390 mm x Depth 1525 mm x Height 1995 mm
Maximum load (evenly distributed over the area) of the test chamber floor 150 kg
per insert grid 50 kg
Total load of the grid supports 100 kg
Nwodpjzfy Rwjfx Airjn
Data for operation:
Test chamber lighting: Halogen bulb 24V, 50W
Rated voltage 3/N / PE AC 400 V ± 10% 50 Hz
Rated power 27.0 kW
Rated current 42.02 A
Heat dissipation water-cooled test cabinets max. heat dissipation to the environment 1.3 kW
Noise measurement:
Sound pressure level approx. 64 dB(A)
Refrigerant: (converted to R-452a)
Weight: approx. 960 kg
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data and information are subject to change!)
We will gladly answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Feutron climate test chamber with humidity control, temperature range -40 ... +100°C, volume 2.0 m³,
FeutronKlimaprüfkammer
Call
Condition: used, Feutron
Type: 3702/06
Water-cooled climate testing chamber
Technical data:
Test chamber nominal volume: 2.0 m³
Dimensions: Test chamber exterior, with humidifier console
Width: 2970 mm, Height: 2370 mm, Depth: 1530 mm
Rear wall
Minimum insertion dimensions: Width: 2970 mm, Height: 2390 mm, Depth: 1550 mm
Test chamber: Width: 2000 mm, Height: 1000 mm, Depth: 1000 mm
Door: double-leaf, clear opening width: 2000 mm, height: 1000 mm
Nwjdpfjzd Sdmjx Airen
Viewing window: heated, 2 pieces, width: 500 mm, height: 600 mm
Feedthrough opening: 1 piece, left side wall, diameter: 75 mm
Temperature range: -40...100°C
Climate range: 10...95°C
Temperature difference, over time: ≤ ± 0.5...± 1.0 ΔN/K
Rate of change measured in the supply air, without load
Cooling: up to 2.0 K/min on average
Heating: up to 2.0 K/min on average
Humidity range: 10...95 % r.h.
Humidity difference, over time: ≤ ± 3.0 % r.h.
Dew point range, intermittently: -5...95°C
Refrigeration system: water-cooled, semi-hermetic Bitzer system
Refrigerant: R507 (Μ-Κ1)
Climate and drying refrigeration system: air-cooled / hermetic system
Refrigerant: R134a (Μ.ΚΚ)
Power supply:
Electrical connection: 400V 3/N/, 50Hz
Power plug: CEE 5-pole, 32 A, with 5.0 m cable
Max. simultaneous power consumption: 10.0 kW
Supply line fuse: 3x 25, Char, C A
Protection class: IP20
Weight: 1300 kg
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Weiss temperature chamber WT3-340/40, 335 liters, temperature range -42°C to +180°C
WeissTemperaturprüfschrank
Call
Condition: used, Weiss
Type: WT3-340/40
Weiss Temperature Test Chamber with S!MCON / 32 Control System, Water-Cooled
(Refrigerant converted to R-452A)
Control Panel: "Touch Panel"
All control and operating commands can be initiated by simply touching the function symbols on the "Touch Panel" control panel.
Adjustable Feet
To compensate for uneven floors and to ensure sufficient ventilation of the machine part, the test chamber is equipped with adjustable feet.
Feedthroughs
The test chamber is equipped with feedthroughs on the right and left sides.
These allow measuring cables and testing equipment to be routed into the test chamber.
Feedthroughs installed as standard
R1: 125 mm diameter
L1: 50 mm diameter
Nwodpfxszgbkhs Airsn
Test chamber volume: approx. 335 liters
Test chamber dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Temporal temperature deviation in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate
Heating: 3.2 K/min
Cooling: 4.0 K/min
Maximum heat compensation: 2300 W
Data for operation:
Test chamber lighting: Halogen bulb 2x 24V, 50W
Rated voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Rated current: 14 A Rated power 4.1 kW
Fuse (to be provided by the customer): 16 A slow-blow
Sound pressure level approx.
measured at a distance of 1 m from the front, 1 m height: 56 dB(A)
Refrigerant: R-452A
Weight: 515 kg
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Vötsch climate test chamber VC 4034, temperature range -40°C to +180°C, 335 liters
VötschVC 4034
Call
Condition: used, Vötsch
Climate testing chamber / Temperature testing chamber
Vötsch VC 4034 Climate testing chamber
Temperature and climate testing chamber, air-cooled
Converted to R452A
For sale is a used climate testing chamber
from the manufacturer Vötsch Industrietechnik GmbH.
The testing chamber is suitable for temperature and climate tests,
environmental simulation, material testing, quality assurance,
as well as development and stress tests.
Nsdpfxszd Dm Hs Airjwn
Technical data
Manufacturer: Vötsch Industrietechnik GmbH
Type: VC 4034
Equipment type: Climate testing chamber / Temperature testing chamber
Test chamber volume: approx. 335 liters
Test chamber dimensions: approx. 580 x 765 x 750 mm (W x D x H)
Housing dimensions: approx. 780 x 1758 x 1800 mm (W x D x H)
Weight: approx. 515 kg net
Temperature range: -40 °C to +180 °C
Temperature change rate, heating: approx. 3.2 K/min
Temperature change rate, cooling: approx. 3.5 K/min
Temperature deviation over time: ± 0.1 to ± 0.5 K
Temperature homogeneity, spatially: ± 0.5 to ± 1.5 K
Climate range, temperature: -40 °C to +180 °C
Humidity range: 10 % to 98 % RH
Temperature deviation over time: ± 0.1 to ± 0.3 K
Temperature homogeneity, spatially: ± 0.5 to ± 1.0 K
Refrigerant: R452A
Refrigerant quantity: 2.5 kg
Maximum suction pressure: 22 bar g
Maximum discharge pressure: 25 bar g
Mains connection: 3/N/PE AC 400 V +10 % / 50 Hz
Rated power: 4.1 kW
Rated current: 12.5 A
Equipment
Touch panel operation
Viewing window in the door
Stainless steel interior
Test chamber lighting
Side feedthrough
Insert grid
Air-cooled system
Documentation / Operating manual
Accessories according to the pictures
Application areas
Temperature testing
Climate testing
Environmental simulation
Material testing
Electronics testing
Quality assurance
Research and development
Condition
Used
Optical condition according to the pictures
Scope of delivery
1x Vötsch VC 4034 Climate testing chamber
Insert grid
Control panel / controller
Documentation / Documents
Accessories according to the pictures
Important note:
For the safety of our customers, the following work will be carried out on the offered climate chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. Documented test run after successful inspection
Shipping or freight shipping possible.
Subject to changes, errors and prior sale.
We will gladly answer any further questions by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Mytron heating cabinet drying cabinet WT 850 +120°C
mytronWärmeschrank
Call
Condition: used, Mytron
Type: WT 850
Mytron Drying Cabinet
The WT 850 drying cabinet is used for the simultaneous drying of several products or auxiliary devices in the semiconductor industry.
Due to its robust design (box-profile frame) and the use of stainless steel for the heating chamber, the WT 850 drying cabinet can be used universally.
The rolling cart allows for easy loading and unloading of the WT 850 drying cabinet.
An exhaust nozzle with a regulating flap allows the cabinet to be connected to a central extraction system.
Technical Data:
External dimensions: Width 1145 mm x Height 1880 mm x Depth 1810 mm
Dimensions of the heating chamber: Width 850 mm x Height 690 mm x Depth 1410 mm
Volume of the heating chamber: approx. 830 liters
Weight: approx. 230 kg, cart 50 kg
Temperature range: 10°C above ambient temperature to +120°C
Spatial temperature consistency: ± 1°C
Temporal temperature consistency: ± 1°C
Nedpfx Aiezd R Tmorswn
Mains connection: 3NPE AC 50 Hz 400 V, 16 A CEE plug
Power consumption: 4.5 kVA
Fusing: 3 x 16 AT, 1 x 6 AT
Control: Digital controller
Safety device: adjustable over-temperature protection
Through-hole:
Exhaust nozzle 100 mm with regulating flap at the top
Intake nozzle 100 mm with regulating flap at the top
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Success:
Your message has been sent.
Listing
Borken
7,016 km
Vötsch VCS 4100 Climate Test Chamber -40 °C to +180 °C Temperature Test Cabinet KK07
VötschVCS 4100
Call
Condition: used, Vötsch VCS 4100 climate testing chamber, -40 °C to +180 °C
Nwodpfx Aijuuiygorsn
Manufacturer: Vötsch
Type: VCS 4100
Temperature range: -40 °C to +180 °C
Supply voltage: 400 V
Rated current: 17 A
Rated power: 11 kW
Refrigerant: R404A
KK-07
You can find more items – new and used – in our shop! International shipping costs available upon request!
Success:
Your message has been sent.
Listing
Borken
7,009 km
Vötsch Temperature Test Chamber VT³ 4100 -40°C to +180°C, 990 liters
VötschVT³ 4100
Call
Condition: used, Vötsch
Type: VT³ 4100
Water-cooled temperature test chamber
S!MCON/ (with touch panel)
Features of this controller:
Color touchscreen with intuitive menu (usually 5.7" or larger)
Programming of temperature/humidity profiles with ramps and dwell times
Data acquisition & logging (e.g., temperature profile, alarms)
USB port for data export (CSV, optionally S!MPATI-compatible)
Network interface (Ethernet) for remote monitoring and control
User management with password protection
Interfaces: Potential-free contacts, optionally Modbus or Profibus
VT³ 4100 – Technical data (temperature test chamber)
Test volume: 990 liters
Temperature range: -40 °C to +180 °C
Temperature deviation over time: ±0.1 to ±0.5 K
Temperature deviation within the chamber: ±0.5 to ±1.5 K
Temperature gradient: 1 to 3 K
Temperature change rate (according to IEC 60068-3-5):
Heating: 4.0 K/min
Cooling: 3.0 K/min
Heat dissipation capacity (max): 4500 W
Calibration values: +23 °C and +80 °C
Internal dimensions (W×D×H): 1100 × 950 × 950 mm
External dimensions (W×D×H): 1390 × 1955 × 1995 mm
Feedthroughs:
The test chamber is equipped with feedthroughs on the left and right sides.
Nodpfxoziyxpj Airown
These allow measurement cables and testing equipment to be placed in the test chamber.
1 x L1 NW 50 mm
1 x R1 NW 125 mm
3 x R1 NW 50 mm
Electrical connection: 3/N/PE AC, 400V ±10%, 50Hz
Power consumption: 11.5 kW
Rated current: 22 A
Noise level: approx. 62 dB(A)
Refrigerant R452A
Weight: 920 kg
For your security as a buyer, please note the following information!
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Weiss Climate Test Chamber WK3-600/0-M, 600 liters, with humidity control, temperature range -5°C to
WeissKlimaprüfschrank
Call
Condition: used, Weiss
Type: WK3 600/0-M
Weiss Climate Test Chamber, Water-Cooled
Nwodpfx Aeziywreiron
Type series WK3-../0
with SIMPAC* control system
Test chamber volume: approx. 600 liters
Test chamber dimensions: Height 950 mm, Width 800 mm, Depth 800 mm
External dimensions: Height 1995 mm, Width 1090 mm, Depth 1660 mm
Data for operation:
Test chamber lighting: LED 24 V, 6.8 W / Halogen bulb 2 x 24V, 50W
Rated voltage: 1/N / PE AC 230 V ±10% 50 Hz
Rated power: 2.3 kW
Rated current: 10 A
Fuse (on customer's side): 16 A, slow-blow
Protection class, control cabinet and operating panel: IP 54
Max. heat dissipation to environment: 1200 W
Sound pressure level approx.
measured at a distance of 1 m from the front, 1.6 m high: 46 dB(A)
Data for temperature tests:
Temperature range: -5°C to +90°C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Temperature deviation spatially: ± 0.5 to ± 1 K
Temperature gradient
(according to IEC 60068-3-5)
Temperature change rate
Heating: 0.6 K/min
Cooling: 0.3 K/min
Heat compensation at +20 °C to +50 °C: 200 W
Data for climate tests:
Temperature range: +10°C to +90°C
Dew point range: 4 to +89.5 °C
Humidity range: 10 to 98 % RH
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.3 K
Temperature deviation spatially: ± 0.5 to ± 1 K
Humidity deviation over time: +1 to +3 % RH
Refrigerant: R-404A
Weight: 610 kg
For your security as a buyer, please note the following information!
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers will be subjected to a test run, which will be monitored with calibrated equipment.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
CTS Temperature Test Chamber T-70/600, temperature range -70°C to +180°C, 600 liters
CTSTemperaturprüfschrank
Call
Condition: used, CTS
Climate testing chamber T-70/600, water-cooled
Temperature range: -70°C to +180°C
Rated voltage: 400V 3/N PE 50 Hz
Rated power: 6.7 kW
Rated current: 10.2 A
Compressor: TFH2480Z/TFH2511Z, refrigerant R23/R404A
Control:
-Microprocessor-controlled regulation and monitoring system
-Simple, user-friendly terminal integrated into the door.
-Digital display of setpoint and actual temperature
Easy adjustment via +/- buttons
-Digital input for temperature in °C
-PLC compatible
-Up to 100 test programs possible
-RS 232 interface
-2 free switching channels for on-site
test item control
Insert rack:
Stainless steel, support surface 820 x 710 mm
Load per rack max. 35 kg
Total load with max. rack capacity 100 kg
Refrigeration unit:
Water-cooled, low-noise, fully hermetic, stepless power adjustment
via electronic monitoring and control system,
environmentally friendly refrigerant R404A/R23
Temperature tests:
Temperature range -70 °C to +180 °C
Temperature deviation ±0.1 to 10.3 K over time
Temperature change rate
measured in the center of the test chamber according to DIN 50 011, Part 12
Heating 2.5 K/min
Nwjdoziycbjpfx Airsn
Cooling 2 K/min
Heat radiation max. 1500 W at +20°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400 V, without test item, without radiation and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions 850 x 830 x 850 mm (W x D x H)
External dimensions 1050 x 1850 x 1900 mm (W x D x H)
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 6.7 kW
Rated current: 10.2 A
Protection class IP 22
Condensate drain, unpressurized R 1/2" internal thread
Sound pressure level < 62 dB(A)
Weight approx. 400 kg
For your safety as a buyer, the following information!
The following points are carried out on our offered chambers in advance:
1. Function check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We will gladly answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Espec temperature shock test chamber TSD-100, two-chamber shock cabinet, -70 °C to +200 °C
EspecTemperaturschocktestkammer
Call
Condition: used, Espec
Type: TSD-100
New evaporator installed in February 2026
100-liter usable volume for larger test specimens up to 30 kg.
Complies with all common international standards.
Water-cooled
Temperature range, warm chamber: +60 °C to +200 °C
Temperature range, cold chamber: -70 °C to 0 °C
Test chamber dimensions: 710 x 345 x 410 (W x H x D) in mm
External dimensions: 1100 x 1885 x 1965 (W x H x D) in mm
Water-cooled refrigeration unit
Program control via touch panel
Automatic defrost
Over-temperature protection
Operating hour counter
Mobile design
2 test specimen baskets made of stainless steel
Cable entry Ø 100 mm
Refrigerant: 3 kg R404A, 1 kg R23
Power supply: 400V 3-phase 50Hz
Max. power consumption: 32A
Condition: used
Weight: 1100 kg
For your safety as a buyer, please note the following information!
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refilling with legally compliant refrigerant
Nodpfszizl Rsx Airewn
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Vötsch temperature test chamber, 190 liters, temperature range -70°C to +180°C, model VTS 7018-5.
VötschVTS 7018-5
Call
Condition: used, Vötsch
Type: VTS 7018-5
Water-cooled temperature test chamber
System converted to R-452A
Temperature range: -70°C to +180°C
Nodpfoziixxox Airown
Temperature deviation (temporal): ±0.1 to ±0.5 K
Temperature deviation (spatial): ±0.5 to ±2.0 K
Temperature change rate (cooling): 7.5 K/min
Temperature change rate (heating): 7.5 K/min
Thermal compensation at +20°C: 3000 W
Thermal compensation at -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 450 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1280 mm, Height 1575 mm
Test chamber volume: 190 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 100 kW, Rated current: 21 A
Fuse, on customer side: 32 A, slow-blow
Sound level at 1m distance (free-field measurement): < 69dB (A)
Side feed-through: 50 cm / 125 cm
Chamber is water-cooled
Refrigerant: R-452A and R23
Weight: approx. 460 kg
For your safety as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerants
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data and information are subject to change!)
We will be happy to answer any further questions you may have by phone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
TIRA Walk-in Climate Simulation Chamber KB 127 TCZ 4022 S -2K Temperature range: -40 to +140°C
TIRAKB 127 TCZ 4022 S -2K
Call
Condition: used, TIRA
Climate simulation chamber / walk-in climate test chamber
TIRA TCZ 4022 S -2K
Air-cooled | -40 to +140 °C | Refrigerant R449A
Nwodpfx Aisz Sn Uveron
For sale is a used, walk-in climate simulation chamber from the manufacturer TIRA.
The system consists of an insulated test chamber, an air handling unit, external humidification,
a machine unit and a control cabinet. It is used for temperature and humidity testing.
Technical data:
Manufacturer: TIRA
Type: TCZ 4022 S -2K
Cooling type: air-cooled
Temperature range: -40 to +140 °C
Temperature stability, supply air: over time ≤ ±0.5 °C; spatially ≤ ±1.0 °C
Heating / Cooling: approx. 2 K/min each (-30 to +85 °C, without test item and thermal load)
Climate range: +10 to +90 °C
Humidity: 10 to approx. 95 % RH
Dew point: +5 to +89 °C
Humidity stability, supply air: over time ≤ ±2.5 % RH
With heat compensation up to 16 kW:
+15 to +80 °C; 15 to approx. 80 % RH
Dew point: +10 to +74 °C
Test chamber (W x D x H): approx. 2260 x 4648 x 2260 mm
External dimensions: approx. 2660 x 6460 x 2800 mm
Door opening (W x H): 2260 x 2260 mm
Climate module KB 127: 1700 x 800 x 1400 mm
Control cabinet: 800 x 500 x 2000 mm
Power connection: 400 V, 3/PE/N, 50 Hz
Rated power: 95 kW; Rated current: 150 A
Fuse rating: 200 A, slow-blow
Total weight according to specifications: approx. 5834 kg
Equipment:
Stainless steel interior and floor
Double-wing door with viewing window approx. 1000 x 1000 mm
Supply air at the top / exhaust air at the bottom on the rear wall
Electric heating, direct cooling and dehumidification
Bitzer 6G-30.2Y; Refrigerant R449A; Oil SEZ 32
Steam humidifier EDB 40
4 test chamber spotlights à 500 W
Insulation: 80 mm PUR and 120 mm mineral wool
Floor load: 15,000 N/m²; Wheel load: 1,500 N/wheel (≥ 4 cm²)
Application areas:
Temperature and climate testing
Environmental simulation
Material and component testing
Quality assurance and development
Condition:
Used
Optical condition according to pictures
Scope of delivery:
TIRA TCZ 4022 S -2K with associated components as shown in the pictures
Items not explicitly mentioned are not part of the sale.
Shipping by freight forwarder is possible.
Subject to changes, errors and prior sale.
We will be happy to answer any further questions by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Vötsch temperature test chamber, 335 liters, temperature range -70°C to +180°C, model VTS 7034-5
Heraeus VötschVTS 7034-5
Call
Condition: used, Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
Temperature range: -70°C to +180°C
Temperature deviation (temporal): ± 0.1 to ± 0.5 K
Temperature deviation (spatial): ± 0.5 to ± 2.0 K
Temperature change rate (cooling): 5.0 K/min
Temperature change rate (heating): 6.5 K/min
Thermal compensation at +20°C: 3000 W
Thermal compensation at -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Test chamber volume: 335 liters
Rated voltage: 3/N/PE AC, 400V ±10%, 50Hz
Rated power: 10 kW, Rated current: 21 A
Sound level at 1m distance (free-field measurement): < 69dB (A)
Side access port: 5.5 cm / 12.5 cm
The chamber is water-cooled.
Refrigerant: R-404A and R23
Weight: approx. 570 kg
For your safety as a buyer, please note the following information:
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers undergo a test run, which is monitored with calibrated equipment.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by phone.
Nsdpfx Aozg Tpijirjwn
Success:
Your message has been sent.
Listing
Borken
7,009 km
Vötsch temperature test chamber, 335 liters, temperature range -70°C to +180°C, model VTS 7034-5
Heraeus VötschVTS 7034-5
Call
Condition: used, Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
Temperature range: -70°C to +180°C
Temperature deviation (temporal): ± 0.1 to ± 0.5 K
Temperature deviation (spatial): ± 0.5 to ± 2.0 K
Temperature change rate (cooling): 5.0 K/min
Temperature change rate (heating): 6.5 K/min
Thermal compensation at +20°C: 3000 W
Thermal compensation at -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Test chamber volume: 335 liters
Rated voltage: 3/N/PE AC, 400V ±10%, 50Hz
Rated power: 10 kW, Rated current: 21 A
Sound level at 1m distance (free-field measurement): < 69dB (A)
Side access port: 5.5 cm / 12.5 cm
The chamber is water-cooled.
Refrigerant: R-404A and R23
Weight: approx. 570 kg
For your safety as a buyer, please note the following information:
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers undergo a test run, which is monitored with calibrated equipment.
Condition: used
Nwjdszg Tp Nepfx Airen
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by phone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Vötsch temperature test chamber, 335 liters, temperature range -70°C to +180°C, model VTS 7034-5
Heraeus VötschVTS 7034-5
Call
Condition: used, Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch Temperature Testing Chamber, Water-Cooled
Temperature range: -70°C to +180°C
Temperature deviation (temporal): ± 0.1 to ± 0.5 K
Temperature deviation (spatial): ± 0.5 to ± 2.0 K
Temperature change rate (cooling): 5.0 K/min
Temperature change rate (heating): 6.5 K/min
Heat compensation at +20°C: 3000 W
Heat compensation at -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Nedpfx Aiozg Tp Asrewn
Test chamber volume: 335 liters
Rated voltage: 3/N/PE AC, 400V ±10%, 50Hz
Rated power: 10 kW, Rated current: 21 A
Sound level at 1m distance (free-field measurement): < 69dB (A)
Side access: 5.5 cm / 12.5 cm
Chamber is water-cooled
Refrigerant: R-404A and R 23
Weight: approx. 570 kg
For your safety as a buyer, please note the following information:
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers undergo a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by phone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Vötsch Temperature Test Chamber VT³ 4150/S -40°C to +180°C, 1540 liters
Heraeus VötschVötsch Temperaturprüfschrank VT³4150
Call
Condition: used, Vötsch
Type: VT³ 4150/S
Vötsch temperature testing chamber
Water-cooled
Rated voltage: 3/N/PE AC, 400 V ±10 %, 50 Hz
Rated power: 11.5 kW Rated current: 22.0 A
Rate of change: Cooling approx. 3.5 K/min.
Rate of change: Heating approx. 4 K/min.
Temperature testing
Temperature range: -40°C to +180°C
Layout
External dimensions: W x D x H approx. 1390 x 2380 x 1995 mm
Nwsdpfx Asziyvujirsn
Test chamber dimensions: W x D x H approx. 1100 x 1475 x 950 mm
Weight approx. 1020 kg / 1540 liters
Refrigerant: R 404A
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
CTS Temperature Shock Test Chamber TSS-70/350-A Hot: +50°C to +200°C Cold: -70°C to +100°C 350 liter
CTSTSS-70/350-A
Call
Condition: used, CTS
Type: TSS-70/350-A
Water-cooled refrigeration unit
For sale is a high-quality temperature shock test chamber from CTS
(Clima Temperatur Systeme), model TSS-70/350-A.
The device is used for performing temperature shock tests
and is typically used in industry, research, and quality assurance.
Application areas:
Material tests
Aging tests
Electronics and component testing
Temperature shock and cycle temperature tests
Technical data:
Type: TSS-70/350-A
Temperature range:
Hot chamber: +50°C to +200°C
Cold chamber: -70°C to +100°C
Electrical data:
Connection: 400 V, 3/N, 50 Hz
Rated power: approx. 20.4 kW
Rated current: approx. 36.5 A
Refrigeration system:
Refrigerant: R404A / R23
Pre-cooling stage: approx. 6.0 kg
Cooling stage: approx. 3.0 kg
Water-cooled
Equipment / Features:
CTS control panel with touch display
Microprocessor-controlled control and monitoring system
Program operation
Digital setpoint and actual value display
2-zone system (hot and cold chamber)
Nwodpfx Aioy Hkgbsren
Automatic carriage for shock tests
Technical design:
Hot and cold chamber separated
Carriage system for rapid temperature change
Test chamber made of stainless steel
Insert shelf / grating
Viewing window in the door
Water cooling connections available
Control cabinet integrated
Dimensions:
External dimensions (H x W x D): approx. 2450 x 2160 x 2200 mm
Internal dimensions (H x W x D): approx. 610 x 850 x 680 mm
Weight: approx. 2500 kg
Other data:
Protection class: IP 54
Operating overpressure: approx. 25 bar
Test pressure: approx. 27.5 bar
For your safety as a buyer, please note the following information!
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of delivery: see pictures
(Subject to changes and errors in the technical data!)
We will be happy to answer any further questions you may have by telephone.
Trust Seal
Dealers certified through Machineseeker

Success:
Your message has been sent.
Listing
Borken
7,009 km
CTS Temperature Shock Test Chamber TSS-70/350-A Hot: +50°C to +200°C Cold: -70°C to +100°C 350 liter
CTSTSS-70/350-A
Call
Condition: used, CTS Temperature Shock Test Chamber
Type: TSS-70/350-A
Year of manufacture: 10/2017
Water-cooled refrigeration unit
For sale is a high-quality temperature shock test chamber from CTS GmbH
(Clima Temperatur Systeme), model TSS-70/350-A.
The device is suitable for temperature shock tests and cyclic temperature tests
in industry, research, development, and quality assurance.
Areas of application:
Material testing
Aging tests
Electronics and component testing
Temperature cycling and shock tests
Automotive and quality testing
Technical data:
Manufacturer: CTS GmbH
Type: TSS-70/350-A
Design: Shock test / Temperature shock test chamber
Temperature ranges:
Hot chamber: +50°C to +220°C
Cold chamber: -70°C to +100°C
Electrical data:
Rated voltage: 400 V, 3/N, 50 Hz
Rated power: 19.8 kW
Rated current: 46.5 A
Refrigeration system:
Pre-cooling stage: R452A, 7.2 kg
Cooling stage: R23, 2.8 kg / 11.0 bar
CO₂ equivalent: 15.41 t / 41.59 t
Nwsdsy H Hk Ajpfx Airon
GWP: 2140 / 14800
Water-cooled
Pressure data / Protection class:
Operating overpressure PS: 25 bar
Test pressure PT: 27.5 bar
Protection class: IP 54
Equipment / Features:
CTS touchscreen control panel
Microprocessor-controlled regulation and monitoring system
Program operation
Digital setpoint and actual value display
2-zone system with hot and cold chamber
Trolley system for rapid temperature shock testing
Viewing window in the door
Integrated control cabinet
Water connections for cooling water available
Technical design:
Hot and cold chambers are separated
Trolley system for rapid temperature change
Test chamber made of stainless steel
Robust industrial design
Connections for cooling water supply and cooling water return available
Connection type according to documents: CEE 63A
Dimensions:
External dimensions (H x W x D): approx. 2450 x 2160 x 2200 mm
Internal dimensions (H x W x D): approx. 610 x 850 x 680 mm
Weight: approx. 2500 kg
Documentation:
Declaration of conformity available
Test certificates available
Operating manual available
Wiring diagram, piping diagram, and installation plan available
Spare parts list and quick guide available
For your security as a buyer:
The following points can be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. Documented test run after successful inspection
Condition:
used
Optical condition see pictures
Scope of delivery:
CTS Temperature Shock Test Chamber TSS-70/350-A
Documentation as available
Note:
The sale is of a used industrial device.
An inspection by arrangement is possible and recommended.
Loading and transport can be arranged by agreement.
(Changes, prior sale, and errors in the technical data are subject to change!)
We will gladly answer any further questions by telephone or message.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Thermotron Temperature Chamber SE-1000-6-6 -70°C to +180°C 986 liters
ThermotronSE-1000-6-6
Call
Condition: used, Thermotron
Type: Thermotron SE-1000-6-6
Thermotron temperature chamber
Water-cooled
Interface is not functioning!
Thermotron temperature chamber SE-1000-6-6
Internal dimensions: W x D x H 1000 x 1000 x 980 mm
Working area volume: approx. 980 liters
Temperature range: -70°C to 180°C
Total heating rate: approx. 4.1 K
Total cooling rate: approx. 1.2 K
Heating rate in °C/minute -65° to 71°C: 6.8°C
Heating rate in °C/minute -65° to 180°C: 5.6°C
Heating rate in °C/minute -40°C to 85°C: 6.5°C
Cooling rate in °C/minute 85° to -40°C: 4.7°C
Cooling rate in °C/minute 71° to -65°C: 3.7°C
Cooling rate in °C/minute 180° to -65°C: 4.3°C
External dimensions - W x D x H: 1250 x 1900 x 2200 mm
Electrical requirements: 400V/5P/N/PE 35 A
Refrigerant: R508B and R404A
Approx. weight: 900 kg
For your safety as a buyer, please note the following information:
The following steps are performed on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Nwedpfezd R T Hsx Airen
Scope of supply: (See image)
(Changes and errors in technical data are subject to change!)
We would be happy to answer any further questions you may have by phone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Vötsch temperature test chamber, 335 liters, temperature range -70°C to +180°C, model VTS 7034-5
Heraeus VötschVTS 7034-5
Call
Condition: used, Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch Temperature Testing Chamber, Water-Cooled
Temperature range: -70°C to +180°C
Temperature deviation (temporal): ± 0.1 to ± 0.5 K
Temperature deviation (spatial): ± 0.5 to ± 2.0 K
Temperature change rate (cooling): 5.0 K/min
Temperature change rate (heating): 6.5 K/min
Heat compensation at +20°C: 3000 W
Heat compensation at -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Test chamber volume: 335 liters
Nwedjzd R Tgspfx Airen
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW, Rated current: 21 A
Sound level at 1m distance (free-field measurement): < 69dB (A)
Side access port: 5.5 cm / 12.5 cm
The chamber is water-cooled.
Refrigerant: R 452A and R 23
Weight: approx. 570 kg
For your safety as a buyer, please note the following information:
The following steps are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with refrigerants that comply with legal requirements
3. After successful inspection, the chambers undergo a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications are reserved!)
We would be happy to answer any further questions you may have by phone.
Success:
Your message has been sent.
Listing
Borken
7,009 km
Thermotron Temperature Chamber SE-1000-5-5 -70°C to +180°C 986 liters 27259
ThermotronSE-1000-5-5
Call
Condition: used, Thermotron
Nwjdpfozd R S Nex Airjn
Type: Thermotron SE-1000-5-5
Water-cooled
Thermotron temperature chamber SE-1000-5-5
Dimensions of the working area - WxDxH: 102 x 100 x 97 centimeters
Working area volume: 986 liters
Temperature uniformity: ± 0.5°C
Temperature range: -70°C to 180°C
Temperature control tolerance: 0.3°C
Overall dimensions - WxDxH: 122 x 188 x 218 centimeters
Electrical requirements 400/3/50 32.4 A
Refrigerant: R-404A / R23
Approximate weight: 862 kg
For your safety as a buyer, please note the following information:
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leakage test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data and information are subject to change!)
We will be happy to answer any further questions you may have over the phone.
We make it easier for you to find: "mytron temperature cabinet t2240 temperature range –40°c to +100°c, 2240 liters"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you