Used Climatic Chamber for sale (6,051)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing

7,009 km
Temperature test chamber 600 liters
VötschVT 7060 –40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VT 7060
Vötsch VT 7060 Temperature Chamber 600 Liter with Simcon 32-net
Chamber is air-cooled
Reliable climate chamber for demanding environmental simulations
Ideal for laboratory, development, and quality assurance applications.
Device Description:
For sale is a professional temperature chamber from the manufacturer Vötsch Industrietechnik, model VT 7060 with SIMcon 32-net controller.
This powerful unit is suitable for a wide range of demanding environmental simulations—from material testing and electronics tests to long-term climatic stress tests.
Technical Data (Excerpt):
Model: Vötsch VT 7060
Internal volume: approx. 600 liters
Temperature range: –40°C to +180°C
Temperature deviation in steady-state conditions:
Temporal: ±0.1 K to ±0.5 K
Spatial: ±0.5 K to ±2.0 K
Temperature change rates (without test specimen):
Heating: 4 K/min
Cooling: 3 K/min
Control system: SIMcon 32-net with touchscreen panel
Interfaces: RS232, optional RS485/422
1 × port NW 50 mm left
1 × port NW 125 mm left
2 × ports, each NW 125 mm right
Dcedpfxswybb No Abcon
External dimensions (approx.): Width 1090 × Height 1960 × Depth 1995 mm
Internal dimensions (approx.): Width 800 × Height 800 × Depth 950 mm
Rated voltage: 3/N/PE AC, 400 V ±10%, 50 Hz
Rated power: 9.1 kW Rated current: 19.0 A
Refrigerants: R 404A and R 23
Weight: approx. 675 kg
For your safety as a buyer, please note the following information!
The following points are carried out on the chambers we offer before sale:
1. Functional check and replacement of necessary components
2. If required, refill with legally compliant refrigerant
3. Leak test with certificate
4. Upon successful inspection, the chambers undergo a documented trial run.
Shipping / Collection:
Collection preferred
Shipping on pallet via freight forwarder Europe-wide possible.
(Shipping costs depending on effort)
Condition: used
Scope of delivery: (See picture)
(Specifications and possible errors subject to change!)
For further questions, please feel free to contact us by phone.
Listing

6,151 km
Cooling chamber
LillnordCombi Room
Call
Year of construction: 2017, condition: good (used), Lillnord Combi Room Cold Storage Chamber
- used
- year of manufacture: 2017
- freezer storage for 18 trolleys 60 x 80 (minus 18°C)
- cold storage chamber for 4–5 trolleys 60 x 80 (plus 6–8°C)
- dismantled and stored in warehouse
- good technical condition
- stainless steel exterior panels
- painted interior panels
Dcjdpfx Asw Dc Uxjbcon
- collection from warehouse
- price on request
Listing

6,385 km
Cooking oven (cooking chamber)
Alto Shaam1200-TH/III Deluxe Control C
Call
Condition: like new (used), The ALTO SHAAM 1200-TH/III Deluxe Control Cook and Hold Oven is a versatile and reliable award-winning commercial oven, ideal for kitchens with limited space. The highly energy-efficient Halo Heat technology enables the unit to both cook and hold food—even overnight—while consuming significantly less energy than conventional cooking methods.
Description Alto-Shaam 1200-TH-III
Cooks by time or via a probe that detects the core temperature of the product, automatically switching from cook mode to hold mode once the set parameters are reached.
Eight programmable menu buttons store favorite recipes in memory (settings for cook/hold/time/probe). This reduces operating requirements to simply loading the oven, pressing the power button, selecting the preset menu, and starting the cycle.
When cooking with the probe, the oven records the highest and lowest temperatures detected by the food probe to ensure items are cooked to the required temperature.
The oven includes the patented SureTemp heat recovery system, which provides instant compensation for any heat loss whenever the door is opened, and gives an audible alert if the door remains open for more than three minutes.
Clear, easy-to-read LED display.
Stackable design for additional capacity.
No oven hood, outside venting, or fire suppression system required (in most areas).
Includes: - Core temperature probe, 6 racks, 2 internal drip pans, 1 external drip pan, 127 mm casters.
Dimensions: 1924 (H) x 574 (W) x 819 (D) mm.
Dcodpfx Abew Ehvdjcjn
Power: 230 V, 4.9 kW, 28.7 A.
Weight: 156 kg.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing

6,816 km
Hot-Chamber Diecasting Machine - Vertic.
FRECHDAW 50
Call
Condition: used, Year of construction: 1992, closing pressure 600 kN
Dcedpfx Aofrvzvsbcen
clamping plate 460x460 mm
distance between columns 300x300 mm
weight of the machine ca. 4,5 t
lock stroke 230 mm
capacity of ejector 40 kN
ejector stroke 70 mm
height of form 120-350 mm
column diameter 56 mm
casting capacity 55 kN
casting plunger stroke 130 m/m
injection plunger diameter 45,50,55 mm
casting volume (DIN 24480) 76,121,165 cm 2
volume cast pressure 345,280,231 kp/cm²
casting area 174,214,260 cm 2
Traverse Stroke 150 m/m
Used Die Casting machine DAW 50 with SBC 2 control for the use of zinc alloys.
Available from used machine stock.
The machine is equipped with an electric furnace from Rauch Typ MO50E and used pneumatic sprayer 401.
Recommendation from the manufacturer is some repair / general overhaul in the overhaul plant. It can be carried out in the scope of agreement.
Listing

7,009 km
Climate test chamber 600 liters with humidity
CTSC-70/600 -70°C bis +180°C
Call
Condition: excellent (used), CTS
Type: C-70/600
Climate Test Chamber CTS C-70/600
incl. Programming/Evaluation Software CID-PRO
– Year of manufacture: 2020 – Water-cooled – Fully equipped – Excellent condition
For sale is a high-quality climate test chamber CTS C-70/600 from 2020, with the latest housing design, water cooling, and extensive special equipment.
The unit is ideally suited for precise climate and temperature testing in research, development, and quality assurance.
Full Equipment includes:
- Volt-free contact for fault reporting
- 2 digital outputs, volt-free – for controlling test samples externally
- Software temperature limiter (min. and max. freely adjustable)
- Ethernet interface
- Programming and evaluation software CID-PRO included
- Observation window in the door
- Automatic water replenishment
- Independent temperature limiter (PT100)
- 1x pipe port NW 50 (right side)
- 2x pipe ports NW 125 (right side)
- 2x pipe ports NW 125 (left side)
- Compressed air connection, switchable via digital channel
– for dry compressed air to prevent condensation
- Mobile/caster-mounted device design
Temperature Testing:
- Temperature range: -70 °C to +180 °C
- Temperature deviation: 0.1 K to 0.3 K over time (in stabilized condition)
- Mean temperature change rate, without test item and without radiant heat:
Heating: 3.5 K/min
Cooling: 3.0 K/min
(in the range from +180 to -65°C)
- Radiant heat max. 4000 W at +20°C
Climate Testing:
- Temperature range: +10°C to +90°C
- Humidity range: 10% to 98% rel. humidity
Dcodpfxewxxf Aj Abcen
- Dew point range: +7°C to +94°C
- Temperature deviation: 0.3 K over time
- Humidity deviation:
1 – 2% r.h. over time up to 90% r.h.
max. 1 – 3% r.h. over time above 90% r.h.
Test chamber dimensions:
Height: approx. 850 mm, Width: approx. 850 mm, Depth: approx. 830 mm
External dimensions:
Height: approx. 1900 mm, Width: approx. 1115 mm, Depth: approx. 1850 mm
Test chamber volume: 600 liters
Electrical connection: 400V 3/N 50Hz
Power rating: 8.7 kW, Nominal current: 14.6 A
Refrigerants: R452A / R23
Weight: 700 kg
Important information for your security as a buyer!
The following steps are performed on all chambers we offer prior to sale:
1. Function check and replacement of necessary components
2. Refilling with legally compliant refrigerant if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of supply: (See image)
(Specifications and information subject to change and error!)
We are happy to answer any further questions you may have by phone.
Discover more used machines
Listing

7,009 km
Shock test chamber –80 °C to +220 °C
VötschVT 7012 S2
Call
Condition: excellent (used), Vötsch
Model: VT 7012 S2
Shock Test Chamber, Air-cooled
Two-chamber design
Hot Chamber:
The temperature range of the hot chamber extends from +50°C to +220°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Dcedpewxc I Uefx Abcen
Heating: 11 K/min
Cold Chamber:
The cold chamber temperature range is from -80°C to +70°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Hot chamber temperature range: +50°C to +220°C
Cold chamber temperature range: -80°C to +70°C
Test chamber dimensions: Width 470 mm, Depth 650 mm, Height 410 mm
External dimensions: Width 930 mm, Depth 2115 mm, Height 1970+ mm
Port diameter: ∅ 67 mm
Voltage: 3/N/PE AC 400V +10% 50 Hz
Nominal power: 10 kW
Nominal current: 25 A
Refrigerants: R452-A / R23
Weight: 1,000 kg
Important information for your safety as a buyer!
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical details are subject to change and correction!)
For further questions, please feel free to contact us by phone.
Listing

7,009 km
Salt spray chamber Corrosion chamber
KöhlerHKT 500 WTG
Call
Condition: excellent (used), Here we offer you a Köhler salt spray chamber.
Köhler Salt Spray Chamber Corrosion Chamber
Köhler Salt Spray Chamber HKT 500
Operation via touch panel
Inner dimensions W x D x H (without hood) 1880 x 840 x 1210 mm
Test chamber volume 500 l
Temperature range chamber room temp. up to 50°C
Mains supply 230V 1P/N/50Hz 3000W
Type: HKT 500 WTG
400 Kg
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Dsdpfx Abon Arqdecjcn
Further questions we can answer on the phone for you.
Listing

7,009 km
Stress test chamber
EspecEHS-221M
Call
Condition: excellent (used), Espec
Here we offer an Espec(ThermoTec) stress test chamber.
Overpressure humidity tests at over 100 degrees in many different modes
Program capacity of 10 patterns with 30
steps per pattern
Dsdsn Arznepfx Abcocn
A variety of protection mechanisms; overheat/overpressure protection, detection of water-
supply failure.Complete door interlock and temperature sensor.
Saturated Temp Range 105 to 142.9°C
Unsaturated Temp Range 105 to 132.9°C
Humidity range 50 to 100% r.h.
Nominal pressure 0.196 MPa at 132.9°C and 100% e.F.
External dimensions: width 740 x height 1553 x depth 1000 mm
Test chamber dimensions: Width 355x Height 355 x Depth 426 mm
Other equipment:
with rails and grid
Test material connections in the interior
Type: EHS-221M
Scope of delivery: See pictures
300 kg
Condition: Used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,009 km
Chamber for parametric testing
S & A4365A
Call
Condition: excellent (used), S & A Test Chamber
Here we offer you a S & A test chamber for parametric testing.
Dcedpfen Arl Sox Abcon
Temperature range
-55 ° C to 200 ° C (LCO2)
-65 ° C to 200 ° C (LN2)
Temperature change rate
15° C / min (Standard Option)
60° C / min (Fast Option)
Stability
± 0.2 ° C (including effects of mains voltage, ambient temperature
between 15° and 45° C and aging)
Uniformity
± 1.0 ° C Max from -65 ° C to -55 ° C
± 0.5 ° C Max from -55 ° C to + 125 ° C
± 1,0 ° C Max from + 125 ° C to + 200 º C
Coolant: LCO2
Chamber can be controlled remotely via IEEE bus or
RS232C interface
Weight approx. 61 kg
Type: 4365A
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,009 km
Temperature chamber 986 liters
ThermotronSE-1000-6-6 -70°C bis + 180°C
Call
Condition: excellent (used), Here we offer you Thermotron temperature chamber.
Water cooled
Thermotron temperature chamber SE-1000-6-6
Inner dimensions: WxDxH 1000 x 1000 x 980 mm
Working volume: approx. 980 liters
Temperature range: -70ºC to 180ºC
Heating up total : ca 4,1 K
Cooling down total : ca 1,2 K
Heating power in ºC/minute -65º to 71ºC: 6.8ºC
Heating power in ºC/minute -65º to 180ºC: 5.6ºC
Dedpfx Abeixtitscjcn
Heating capacity in ºC/minute -40º to 85ºC: 6.5ºC
Cooling capacity in ºC/minute 85º to -40ºC: 4.7ºC
Cooling capacity in ºC/minute 71º to -65ºC: 3.7ºC
Cooling capacity in ºC/minute 180º to -65ºC: 4.3ºC
External dimensions - WxDxH: 1250 x 1900 x 2200 mm
Electrical requirements 400V/5P/N/PE 35 A
Refrigerants: R508B and R404 A
Approx. weight: 900 kg
Type: Thermotron SE- 1000-6-6
For you as a buyer, the following information for your safety!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,009 km
Temperature test chamber
Heraeus VötschHT 7010 -70°C bis +180°C
Call
Condition: excellent (used), Type: HT 7010
Heraeus Vötsch temperature test cabinet, water-cooled
Temperature deviation in time ± 1 K
Temperature deviation in space ± 2 K
Housing dimensions: Width 820 mm Depth 840 mm Height 1670 mm
Dcodpfx Aohhyz Sebcen
Interior: Width 550 mm Depth 350 mm Height 550 mm
Rated voltage: 230V +6/-10% 1/N 50Hz
Rated power: 3.2 kW Rated current: 14.5 A
Temperature range -70°C to + 180°C
2 x side feedthrough 9cm
Weight approx. 260 kg
Refrigerant: R404A and R23
For your safety as a buyer, the following information! The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing

7,009 km
Temperature test chamber
RS-SimulatorenTS 600/45 EX
Call
Condition: excellent (used), RS Simulators
Here we offer a test cabinet.
Water cooled
Temperature range: -40°C to +180°C
Test chamber dimensions: 850mm x 850mm x 800mm (WxHxD)
Outer dimensions: 1100mm x 1850mm x 1500mm (WxHxD)
current consumption: 13,5 A
Refrigerant: R404A
Dedpsg Urq Ijfx Abcocn
Connection voltage: 3x400V/N/PE 9A
Weight: approx. 750kg
Type: TS 600/45
Explosion proof operation not tested
but Max 160°C in this
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in technical data, specifications are reserved!)
Further questions we can answer gladly on the phone for you.
Listing

7,009 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), White temperature shock test chamber
Here we offer a temperature shock test chamber.
Weiss temperature shock test chamber air cooled
( Compressor was renewed ! )
Specification:
Temperature range hot chamber +60°C ... +220°C
Dsdpfjk E Htyox Abcocn
Temperature range cold chamber -10°C ... -80°C
Change hot-/cold chamber 10 s
Temperature constancy ±1 K
Dimensions and further data:
External dimensions: Height 1990 mm
Width ( without and with swivel arm ) without....ca. 1820 mm with....ca. 1915 mm
Depth ( without and with test chamber door ) without....approx. 900 mm with....approx. 1155 mm
Dimensions of the lifting basket ( test chamber ) height 450 mm, width 500 mm, depth 600 mm
volume 130 liters
Test space load max. 20 kg
Test chamber floor load max. 20 kg
Cooling water pressure min. 2 ... max. 6 bar
Max. Backup fuse 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of unit approx. 65 dB(A)
Cooling cascade water cooled
Connected load: 3/N/PE/AC 400V ±10% 50Hz /14,0 kW
nominal current 26,0 A
Refrigerant R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,009 km
Climate chamber
VötschVC³ 4060
Call
Condition: excellent (used), Heraeus Vötsch climatic test chamber
Here we offer a Heraeus Vötsch climatic test chamber.
Heraeus Vötsch climatic test chamber with humidity (water cooled)
Test chamber dimensions: Width 800 mm x depth 800 mm x height 950 mm
Housing dimensions: Width 1090 mm x depth 1960 mm x height 1995 mm
Characteristic values for temperature tests:
Temperature range: -45°C to +180°C
Djdpfxsmt Du To Abcscn
temporal ± 0.1 to ± 0.5 K
spatially ± 0.5 to ± 1.5 K
Temperature change rate according to IEC 60068-3-5
heating: 4.0 K/min
cooling: 3.0 K/min
Characteristic values for climatic tests:
Temperature range: -45°C to +180°C
Temperature deviation in steady state, according to IEC 60068-3-5
depending on test room temperature
Temperature range: - 10°C to +95°C
temporal ± 0.1 to ± 0.3 K
spatially ± 0.5 to ± 1.0 K
Humidity range: 10 % to 98 % r. h.
Humidity deviation temporal +1 to ±3
Electrical connection:
Rated voltage: 3/N/PE AC 400V±10% 50Hz
Rated power: 7,8 kW
Rated current: 15,0 A
Refrigerant R452A
Test chamber capacity: approx. 600 liters
Weight: approx. 620 kg net
Type: VC³ 4060
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.Condition: gebraucht / usedScope of delivery: (See picture)
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,009 km
Temperature test chamber 335 liters
Vötsch-70°C bis +180°C VTS 7034-5
Call
Condition: excellent (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50 Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
Dedpfx Absu H U Twecjcn
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have over the phone.
Listing

7,009 km
Temperature chamber with vibration table
EspecQualmark T2.5 + Kompressor 99480630
Call
Condition: like new (used), HALT/ HASS Espec
Here we offer you a temperature chamber.
Temperature -100 to + 200°C
Table in lower position (WxDxH) 889 x 889 x 889 mm
Table in upper position (WxDxH) 889 x 889 x 635 mm
Overall dimensions (WxDxH) 1425 x 1748 x 2134 mm
Work table 762 x 762 mm
Max load 145 kg
Acceleration 5 to 75 gRMS
Voltage
480 or 440 V / 60 A / 3F
400 or 380 V / 80 A / 3F
Type: Qualmark T2.5 + compressor 99480630
Condition: used Only 147 hours
Dedpfxsqwybge Abcecn
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
More We will be happy to answer any questions you may have over the phone.
Listing

7,009 km
Walk-in climate chamber with humidity
RS-SimulatorenKKM 40/45S
Call
Condition: excellent (used), Here we offer you a walk-in climate chamber.
Manufacturer: RS Simulators, water-cooled
The chamber can be dismantled into 3 parts for transport (bolted)
Temperature range: -30°C to +100°C
Refrigerant: 20kg R-404A + 20kg R-452A
External dimensions: approx. width 3920 mm, depth 7350 mm, height 2600 mm
Test room dimensions: approx. width 3500 mm, depth 5400 mm, height 2110 mm
Electrical data: 68kW nominal power
Voltage: 3x400V/PE; Current: 135A
Type: KKM 40 / 45 S
Further technical data will follow!
For your security as a buyer, the following information!
The following points are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
Dcjdpfx Asqw U Aasbcjn
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data and information are reserved!)
We are happy to answer further questions by phone for you.
Listing

7,009 km
Temperature test chamber 270 liters
VötschVTS³ 7027-25 -72°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VTS³ 7027-25
Heraeus Vötsch temperature test chamber, water-cooled
Performance data:
With temperature change rate of 25 K/min
Test chamber dimensions Height 750 mm Width 580 mm Depth 615 mm
External dimensions Height 1775 mm Width 780 mm Depth 1895 mm
Temperature range -72°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5
Temperature homogeneity in space ± 0.5 to ± 2.0
Temperature change rate cooling 25 K/min
Temperature change rate heating 25 K/min
Heat compensation at -20 °C 8000 W
Heat compensation at +20 °C 8000 W
Test volume: 270 liters
2x lateral feed-through ∅ 125 cm
1x side feed-through ∅ 50 cm
Cabinet is water-cooled
Test room lighting:
Dcsdpfjtz Rl Dsx Abcon
LED strip 24 V, 6.8 W / 2x halogen bulb 24 V, 50 W
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 24 KW
Rated current: 42 A
Refrigerant: R-404A and R-23
Weight: approx. 980 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,009 km
Salt spray chamber
WeissSC/KWT 450
Call
Condition: good (used), White
Type: SC/KWT 450
Salt spray chamber
Technical data:
Test chamber capacity 450 liters
Max. load 100 kg
Brine storage tank 180 liters
External dimensions: Height 920 mm Width 1930 mm Depth 800 mm
Test compartment dimensions: Height 740 mm Width 850 mm Depth 570 mm
Areas of application:
Corrosion tests:
Salt spray test: room temp. up to + 50°C
Condensation water test: Room temp. up to + 45°C
Humidifier +75°C
Temperature constancy
The temperature deviation over time is ± K.
Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated power 2.0 kW Rated current 8.5 A
Combination:
Salt spray test SS: DIN 50021
Condensation water test KFW: DIN 50017
Normal climate (ventilation): DIN 50014
Dcjdpjudvg Rofx Abcjn
Weight: 180 kg
Condition: second-hand / used
Scope of delivery: (see picture)
(We reserve the right to make changes and errors in the technical data and specifications)
We will be happy to answer any further questions you may have on the phone.
Listing

7,009 km
Stress test chamber
EspecEHS-221MD
Call
Condition: excellent (used), Espec
Here we offer an Espec (ThermoTec) stress test chamber.
Outer dimensions: W x H x D: 860 x 1795 x 1000 mm
Test chamber dimensions W x H x D: 355 x 355 x 426 mm
2 x 46 l
Voltage 230 V 1/N 50 Hz
Rated current 37A
Fuses 250 V , 2 x 3 A
Type: EHS-221MD
Temperature range: + 105°C to + 142.9°C
Humidity range 75 to 100 % r.H.
Temperature constancy: -+ 0.5 °C
Pressure range: 0 to 2.0 kg/cm²
Heat-up or pressure build-up time: from 0 to 2.0 kg/cm² in about 60 minutes
390 kg
Dcodepdm Uyspfx Abcen
Condition: Used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,009 km
Temperature test chamber 350 liters
CTSTS-70/350 -70°C bis 180°C
Call
Condition: excellent (used), Here we offer you a temperature test cabinet.
Water cooled
Technical performance data:
Temperature working range
Temperature range in °C -70 / +180°C
Rate of change according to DIN 50 011, part 12
Cooling rate: approx. 5 K/min
Heating rate: approx. 5 K/min
Dimensions:
Test volume: 350 liters
Test chamber dimensions height, approx. 750 mm, width, approx. 650 mm, depth, approx. 720 mm
External dimensions height, approx. 1800 mm, width, approx. 850 mm, depth, approx. 1640 mm
Operating data:
Electrical connection 400 V, 3/N, 50 Hz.
nominal power 13,3 kW
Refrigerant: R404A / R23
Weight: approx. 650 Kg
Type: TS-70/350
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Dodpon Sl T Ssfx Abcjcn
Further questions we can answer on the phone for you.
Trust Seal
Dealers certified through Machineseeker

Listing

7,009 km
Temperature chamber 2000 liters
CTST-40/2000 -40°C bis +180°C
Call
Condition: excellent (used), CTS
Type: T-40/2000
Air-cooled temperature test chamber
Technical design:
Refrigeration unit:
air-cooled, low-noise, fully hermetic, infinitely variable power adjustment
Dcjdpsup T Uqofx Abcon
through electronic monitoring and control system,
environmentally friendly refrigerant R404A
Door:
fully opening door, door hinge left,
one-handed operation, lockable.
Shelf:
Stainless steel, support surface 970 x 980 + 500 mm
Max. load per shelf 35 kg
Total load with max. grid load 100 kg
Test area lighting: 3x halogen lamp 20 W, 12 V
Control:
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoint values
Error messages in plain text
RS 232 interface
Free switching channels for on-site test material control
Temperature range: -40°C to +180°C
Nominal voltage: 400V 3/N 50Hz
Rated power: 10.4 kW
Nominal current: 17.2 A
Compressor: TFH2516Z
Pipe feed-through NW 50
Control panel
Window 570x710 mm
Electrical connection, cable length 5m
Technical performance data:
Temperature tests:
Temperature range -40°C to +180°C
Temperature deviation ≤ ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 1.5 K/min
Heat radiation:
approx. 2500 W at +20°C
approx. 2100 W at ± 0°C
approx. 1500 W at -20°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume: 2000 liters
Test chamber dimensions: Height 900, width 975, depth 2200 mm
External dimensions: Height 1950, width 1290, depth 3145 mm
Operating data:
Electrical connection: 400 V +6/-10 %, 3/N, 50 Hz
Rated power: 17.2 kW
Protection class: IP 22
Condensate drain unpressurized R 1/2" internal thread
Sound pressure level (according to DIN EN ISO 3744
measured at a distance of 1 m from the front) < 55 dB(A)
Weight: approx. 1200 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,009 km
Climate test chamber with humidity 64 liters
VötschVCL 4006 -40 bis + 180°C
Call
Condition: excellent (used), Vötsch
Type: VCL 4006
Vötsch temperature and climate test chamber, air-cooled
32 bit S!MPAC* control with touch panel
Potential-free contact for test material switch-off
Independent, adjustable temperature limiter tmin/tmax
Psychrometric humidity measurement system
TCP/IP interface
Large observation window
Test room lighting
1 pipe feed-through 50 mm
2 insertion grilles
Air-cooled cooling circuit
Humidification bath
Calibration of 2 temperature values and 2 humidity values
Test chamber capacity 64 liters
Performance for temperature tests -40 to + 180°C
Temperature deviation temporal ±0.3 to ±1.0 K
Temperature homogeneity in space ±0.5 to ±2.0 K
Rate of change
Heating 3.5 K/min
Djdpeu Spxlofx Abcscn
Cooling 5.0 K/min
Heat compensation max.800 W
Temperature calibration value +23 °C and +80 °C
Performance for climate tests VCL
Temperature range +10 to +95 °C
Humidity range 10 to 95%r.H.
Humidity deviation over time ±1 to ±3 %RH
Temperature deviation temporal ±0.3 to ±0.5 K
Temperature homogeneity in space ±0.5 to ±1.5 K
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 470 mm Depth 345 mm Height 400 mm
External dimensions: Width 760 mm Depth 980 mm Height 1070 mm
Sound pressure level: 56 dB(A)
Nominal power, max. 1.8 kW
Rated current: 8.0 A
Electrical connection: 1/N/PE AC 230 V ±10 %, 50 Hz
Refrigerant: R 404A
Weight: 235 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,009 km
Temperature shock test chamber
CTSTSS-70/130 +50°C...+250°C -80°C...+100°C
Call
Condition: excellent (used), CTS
Type: TSS-70/130
CTS water-cooled temperature shock test chamber
Type series TSS -70/130
Test chamber volume 130 liters
Test chamber dimensions:
Height, approx. 410 mm Width, approx. 480 mm Depth, approx. 660 mm
External dimensions:
Height, approx. 1820 mm Width, approx. 940 mm Depth, approx. 2335 mm
Temperature operating range:
Temperature range in °C :
Hot chamber +50/+250°C
Cold chamber -80/+100°C
Retempering of ICs < 15 min in kg 10.0
Car changeover time in sec. < 10
Max. test weight in kg 50
Temperature constancy over time in K ± 1
Electrical connection 400 V +6% -10%, 3/N, 50 Hz
Connected load in kW approx. 16.6
Condenser chiller water-cooled
Test chamber weight in kg approx. 950
Sound pressure level in dB(A) < 60
Feed-through Ø in mm 125
Refrigerant: R404A/R23
Weight: 950 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Dcsdpfstql H Asx Abcen
We will be happy to answer any further questions you may have on the phone.
Listing

7,009 km
Climate chamber with humidity 34 liters
WeissWKL 34/60 -60°C bis 150°C
Call
Condition: excellent (used), White
Type: WKL 34/60
Weiss air-cooled climate chamber
Refrigerant converted to R-452A
-60°C to 150°C
Room volume: 34 liters
Entry port installed in basic equipment:
R1 NW 50 mm
L1NW 120 mm
Internal dimensions: Height 310 mm Width 324 mm Depth 300 mmm
External dimensions: Height 1740 mm Width 630 mm Depth 970 mmm
Characteristic values for temperature tests:
Temperature range -60 to +150 °C
Temperature differences in steady state, according to IEC 60068-3-5)
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 1 K ± 1 to ± 2 K
Temperature deviation in space (corresponds to temperature gradient) 2 to 4
Temperature change rate (according to IEC 60068-3-5)
Heating 2.5 K/min
Cooling 3 K/min
Heat compensation max. 550 W
Characteristic values for climate tests:
Temperature range +10 to +95 °C
Dcedpfetr Dinjx Abcen
Humidity range 10 to 98 %r.H.
Temperature and humidity differences (in steady state, according to IEC 60068-3-5)
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 0.5 K
Temperature deviation in space ± 0.5 to ± 1.5
(corresponds to temperature gradient) 1 to 3
Humidity fluctuation over time in the center of the usable space ± 3 to ± 5 %RH
Data for operation:
Test room lighting Halogen bulb 12V, 20W
Nominal voltage 1/N / PE AC 230 V ± 10 % 50 Hz
Rated power 2.5 kW
Rated current 11 A
On-site fuse 16A slow-blow
Heat dissipation air-cooled test chambers
Max. Heat dissipation to surroundings 1700 W
Refrigerant: R-452A / R23
Weight: 140 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
We make it easier for you to find: "climatic chamber"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Climatic Chamber (6,051)
Search Machineseeker now with more than 2,00,000 used machines:Browse through the most popular machine descriptions:
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month