Dry-running double pumpWilo
DL-E 100/145-11/2-S1
Dry-running double pump
Wilo
DL-E 100/145-11/2-S1
ONO plus VAT
€6,640
Condition
Used
Location
Borken 

Show images
Show map
Machine data
- Machine type:
- Dry-running double pump
- Manufacturer:
- Wilo
- Model:
- DL-E 100/145-11/2-S1
- Condition:
- good (used)
Price & Location
ONO plus VAT
€6,640
- Location:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

Call
Details about the offer
- Listing ID:
- A18920911
- Reference number:
- 33806
- Update:
- 27.11.2025
Description
Wilo DL-E 100/145-11/2-S1 Glanded double pump
Glanded double pump in inline design for pipe installation or foundation installation with integrated frequency converter for electronic control for constant or variable differential pressure (Δp-c/Δp-v).
Design
Electronically controlled glanded double pump in inline design with flange connection and automatic power adjustment
Application
Pumping of heating water (in accordance with VDI 2035), cold water and water-glycol mixtures without abrasive substances in heating, cold water and cooling systems.
Equipment/function
Operating modes
Δp-c for constant differential pressure
Δp-v for variable differential pressure
PID control
Actuator mode (n=constant)
Manual operating level
Setting the differential pressure setpoint
Setting the speed (manual control mode)
Setting the operating mode
Setting pump ON/OFF
Configuration of all operating parameters
Error acknowledgement
External control functions
“Priority Off” control input
“External pump replacement” control input (only effective for dual pump operation)
Analog input 0-10 V, 0-20 mA for actuator operation (DDC) and remote setpoint adjustment
Analog input 2-10 V, 4-20 mA for actuator operation (DDC) and remote setpoint adjustment
Analog input 0-10 V for actual value signal of the pressure sensor
Analog input 2-10 V, 0-20 mA, 4-20 mA for actual value signal of the pressure sensor
Message and display functions
Collective fault message SSM
Collective operation message SBM
Data exchange
Infrared interface for wireless data exchange with IR monitor/IR stick
Slot for Wilo IF modules (Modbus, BACnet, CAN, PLR, LON) for connection to the building automation system
Safety functions
Full motor protection with integrated tripping electronics
Access lock
Double pump management (double pump or 2 x single pump) 2 x single pump)
Cedpowbqrtofx Addeaa
Main/standby mode (automatic fault switchover)
Main/standby mode Pump replacement after 24 hours
Add-on mode
Add-on mode (efficiency-optimized peak load switch-on and switch-off)
Your benefits
Energy saving thanks to integrated electronic power adjustment
Simple operation thanks to green button technology and display
Various operating modes: Main/standby mode and parallel operation
Configurable fault behavior tailored to heating and air conditioning applications
Integrated full motor protection (KLF) with tripping electronics
Drive
Mains connection
3~380 V, 50/60 Hz
3~400 V, 50/60 Hz
3~440 V, 50/60 Hz
Motor efficiency class: IE4
Power consumption P1 max: 13000 W
Nominal motor power P2: 11 kW
Current (max) Imax: 21 A
Speed max. nmax: 2970 1/min
Interference emission EN 61800-3
Interference immunity EN 61800-3
Insulation class: F
Protection class motor: IP55
Motor protection: KLF integrated
Installation dimensions
Installation length L0 500 mm
Suction-side pipe connection DNs DN 100
Pressure-side pipe connection DNd DN 100
RRP: € 29,006.25
Find more new and used items in our store!
International shipping costs on request!
Glanded double pump in inline design for pipe installation or foundation installation with integrated frequency converter for electronic control for constant or variable differential pressure (Δp-c/Δp-v).
Design
Electronically controlled glanded double pump in inline design with flange connection and automatic power adjustment
Application
Pumping of heating water (in accordance with VDI 2035), cold water and water-glycol mixtures without abrasive substances in heating, cold water and cooling systems.
Equipment/function
Operating modes
Δp-c for constant differential pressure
Δp-v for variable differential pressure
PID control
Actuator mode (n=constant)
Manual operating level
Setting the differential pressure setpoint
Setting the speed (manual control mode)
Setting the operating mode
Setting pump ON/OFF
Configuration of all operating parameters
Error acknowledgement
External control functions
“Priority Off” control input
“External pump replacement” control input (only effective for dual pump operation)
Analog input 0-10 V, 0-20 mA for actuator operation (DDC) and remote setpoint adjustment
Analog input 2-10 V, 4-20 mA for actuator operation (DDC) and remote setpoint adjustment
Analog input 0-10 V for actual value signal of the pressure sensor
Analog input 2-10 V, 0-20 mA, 4-20 mA for actual value signal of the pressure sensor
Message and display functions
Collective fault message SSM
Collective operation message SBM
Data exchange
Infrared interface for wireless data exchange with IR monitor/IR stick
Slot for Wilo IF modules (Modbus, BACnet, CAN, PLR, LON) for connection to the building automation system
Safety functions
Full motor protection with integrated tripping electronics
Access lock
Double pump management (double pump or 2 x single pump) 2 x single pump)
Cedpowbqrtofx Addeaa
Main/standby mode (automatic fault switchover)
Main/standby mode Pump replacement after 24 hours
Add-on mode
Add-on mode (efficiency-optimized peak load switch-on and switch-off)
Your benefits
Energy saving thanks to integrated electronic power adjustment
Simple operation thanks to green button technology and display
Various operating modes: Main/standby mode and parallel operation
Configurable fault behavior tailored to heating and air conditioning applications
Integrated full motor protection (KLF) with tripping electronics
Drive
Mains connection
3~380 V, 50/60 Hz
3~400 V, 50/60 Hz
3~440 V, 50/60 Hz
Motor efficiency class: IE4
Power consumption P1 max: 13000 W
Nominal motor power P2: 11 kW
Current (max) Imax: 21 A
Speed max. nmax: 2970 1/min
Interference emission EN 61800-3
Interference immunity EN 61800-3
Insulation class: F
Protection class motor: IP55
Motor protection: KLF integrated
Installation dimensions
Installation length L0 500 mm
Suction-side pipe connection DNs DN 100
Pressure-side pipe connection DNd DN 100
RRP: € 29,006.25
Find more new and used items in our store!
International shipping costs on request!
Seller
Note: Register for free or log in, to access all information.
Registered since: 2008
Send inquiry
Telephone & Fax
+49 2862 ... show
These listings may also fit your interest.
Listing
Nordhorn
6,992 km
Driven roller conveyor system
SSI Schäfer
SSI Schäfer
Listing
Oftersheim
6,886 km
Centrifugal pump
GrundfosCR 60 20 A-F-A-BBUE Model B500002P39447
GrundfosCR 60 20 A-F-A-BBUE Model B500002P39447
Listing
Berlin
6,574 km
Centrifugal Pump
Alfa LavalLKH 85/226 DMS
Alfa LavalLKH 85/226 DMS
Listing
Klam bei Grein
6,426 km
Filling system wood chips filling auger
Löttner Maschinenbau
Löttner Maschinenbau
Listing
Wiefelstede
6,930 km
Electric motor 160 kW 1485 rpm
LoherAMGA-315MD-04A
LoherAMGA-315MD-04A
Listing
Leipzig
6,627 km
Linearmotor
Leomotor A/SKC 218B159 - LM 2000 - 12630
Leomotor A/SKC 218B159 - LM 2000 - 12630
Listing
Luckenwalde
6,581 km
Bar Transferred Conveyor Systems
PROTONBar Transferred Conveyor
PROTONBar Transferred Conveyor
Listing
Frankenberg/Sa.
6,577 km
ETANORM G 150-250 pump
KSBETANORM G 150-250 G10
KSBETANORM G 150-250 G10
Listing
Piskorzów
6,291 km
Electric motor
ABBM3BP 400LKB 4 IMB3/IM1001 630 kW
ABBM3BP 400LKB 4 IMB3/IM1001 630 kW
Listing
Galgenau
6,449 km
Overloading screw / screw conveyor
MixitTCF
MixitTCF
Your listing has been deleted successfully
An error has occurred