Used Thermal Shock Test Chamber for sale (14,079)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
7,009 km
Dust test chamber dust chamber
Testzentrum Baden Primus EngineeringDST350
Call
Condition: excellent (used), Primus Engineering
Type: DST 350
This testing equipment was designed for performing IP protection class tests for "dust" according to, for example, DIN 40050 Part 9 and DIN EN 60529.
The testing equipment is intended for testing technical components under the influence of dust and negative pressure within the limits specified in the technical data.
Operation / HMI
Control panel with screen and buttons
Manual controls
Predefined test sequences
Integrated vacuum circuit with flow measurement
Technical data:
Total electrical power: Max. 5 kW
Ljdpfxjzgbtij Abysrn
Connection voltage: 400V/50Hz 3-N/PE (16A CEE socket)
Dimensions: Width approx. 920 mm, Depth approx. 710 mm, Height approx. 1,770 mm
Dimensions of test chamber: Width approx. 700 mm, Depth approx. 650 mm, Height approx. 770 mm
Volume approx. 350 l
Weight: approx. 200 kg
Vacuum: 0 to -100 mbar
Suction air flow: 0 to approx. 5 l/min
Operating climate range: Temperature: +12 °C to +30 °C
Humidity: 25 % rel. to 75 % rel., non-condensing
Protection class tests according to DIN 40050 Part 9 and DIN EN 60529 (VDE 0470 Part 1)
Dust test:
Dust-protected IP5X and IP5KX
Dust-tight IP6X and IP6KX
with and without vacuum
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data and specifications are subject to change!)
We will be happy to answer any further questions you may have by phone.
Listing
Borken
7,009 km
Temperature test chamber
CTSTSR-30/1000
Call
Condition: good (used), CTS
Type: TSR-30/1000
Water-cooled
The type designation of the CTS cabinet series is structured as follows:
e.g., Type TSR-30/1000
1) T means: Temperature
2) S means: Stress Screening
3) R means: External Conditioning
4) -30 means: Lower temperature -30 °C
5) 1000 means: 1000 liters test chamber volume
Technical performance data:
A) TSR-30/1000 base unit without hose connections,
i.e., for use as a stand-alone temperature test chamber
Ljdpfjzgbntjx Abyern
Temperature tests:
Temperature range -40°C to +180°C
Final temperature -45°C
Temperature deviation ≤ ±0.3 K over time
Temperature change rate according to IEC 60068-3-5
Heating 6.0 K/min
Cooling 5.0 K/min
Heat radiation
approx. 5000 W at +20°C
approx. 4200 W at ±0°C
approx. 3000 W at -20°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test specimen, without radiation, and without additional equipment.
Air volume flow rate
approx. 2000 m³/h
B) TSR-30/1000 base unit with hose connections,
for connection to an on-site external test chamber
Temperature tests:
Temperature range -30°C to +170°C
Temperature deviation ≤ ±0.1 to 0.5 K over time
Average temperature change rate,
measured with the circuit short-circuited
Heating 4.0 K/min
Cooling 4.0 K/min
in the range of +150°C to -10°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test specimen, without radiation, and without additional equipment,
measured with the circuit short-circuited
Caution: The on-site external test chamber must be absolutely sealed and appropriately insulated;
any penetrations must be optimally sealed on-site.
Dimensions:
Test volume 1000 liters
Air circulation connection Ø 200 mm
Test chamber dimensions height 900 mm width 1000 mm depth 1100 mm
External dimensions height 1950 mm width 1270 mm depth 2245 mm
Technical design:
Refrigeration unit:
water-cooled, low-noise, hermetically sealed
stepless power adjustment by
electronic monitoring and control system,
environmentally friendly refrigerant R404A
Door:
fully opening door, door stop on the left,
one-hand operation, lockable.
Insert grid:
stainless steel, support area 970 x 980mm
Load per grid max. 35 kg
Total load with max. grid capacity 100 kg
Test chamber lighting: Halogen lamp 20 W, 12 V
Control:
- 32-bit controller
- LCD control panel
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 13.3 kW
Protection class IP 22
Sound pressure level < 60 dB(A)
Weight approx. 850 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by phone.
Listing
Borken
7,009 km
Temperature test chamber 600 liters
WeissWT3-600/40 -42°C bis +180°C
Call
Condition: excellent (used), Here, we offer a Weiss temperature chamber.
Weiss temperature test chamber with S!MCON / 32 control, air-cooled
(Refrigerant converted to R-452A)
Control panel »Touchpanel«
On the »Touchpanel« control panel, all control and operating commands can be triggered by simply touching the function symbols.
Adjustable feet
To compensate for uneven floors and to ensure sufficient ventilation of the machine part, the test chamber is equipped with adjustable feet.
Feedthroughs
The test chamber is equipped with feedthroughs on the right and left sides.
These allow measuring cables and test equipment to be placed in the test chamber.
Ledpfx Abezga Huoysrn
Feedthrough installed as standard
R1: 125 mm
L1: 50 mm
Test chamber volume: approx. 600 liters
External dimensions with hinges and door lock
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock
Height 1995 mm, Width 1000 mm, Depth 1660 mm
Internal dimensions: Height 950 mm, Width 800 mm, Depth 800 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Temperature deviation spatially: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5)
Heating: 4.0 K/min
Cooling: 3.0 K/min
Maximum heat compensation: 2500 W
Data for operation:
Test chamber lighting: halogen bulb 2 x 24V, 50W
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 15 A, Rated power 7.8 kW
Fuse, to be provided by the customer: 16 A, slow-blow
Sound pressure level approx.
measured at a distance of 1m from the front, 1m height: 61 dB(A)
Refrigerant: R-452A
Weight: 620 kg
Type: WT3-600/40
For your safety as a buyer, the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Borken
7,009 km
Climate test chamber with humidity, 335 liters
WeissWK3-340/40 -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss climate testing chamber.
Weiss climate testing chamber, water-cooled
(Refrigerant converted to R-452A)
Temperature testing
Volume 335 liters
Test chamber dimensions:
Test chamber dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Minimum temperature -42°C
Maximum temperature +180°C
Temperature change rate, cooling 4 K/min
Temperature change rate, heating 3.2 K/min
Ledpfx Aezgavvebyorn
Temperature deviation, time-based ± 0.1 to ± 0.5 K
Temperature homogeneity, spatially ± 0.5 to ± 1.5 K
Climate testing:
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range 10 to 98% RH
Temperature deviation, time-based ± 0.1 to ± 0.3 K
Temperature homogeneity, spatially ± 0.5 to ± 1 K
Humidity deviation, time-based ± 1 to ± 3 % RH
Voltage: 3/N/PE AC 400V±10% 50Hz
Rated power 4.1 kW Rated current: 14 A
Refrigerant: R-452A
Type: WK3-340/40
Weight Approx. 515 kg
For your security as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Climate test chamber -40 to +180°C
WeissWK-480/40/10 480 Liter m. Feuchte
Call
Condition: excellent (used), We are offering a Weiss climate testing chamber.
Water-cooled.
Test chamber lighting: halogen bulb 24V, 50W.
Data for temperature tests:
Temperature range: -40°C to +180°C.
Temperature deviation over time in the center of the usable space: ± 0.3 to ± 0.8 K.
Temperature deviation spatially: ± 0.5 to ± 2 K.
Temperature change rate:
Heating: 10 K/min.
Cooling: 12.5 K/min.
Heat compensation at +20°C: 8000 W.
Lrsdpfx Ajzgaipsbyon
Heat compensation at -20°C: 3000 W.
Data for climate tests:
Temperature range: +10°C to +95°C.
Humidity range: 10 to 98 % RH.
Temperature deviation over time in the center of the usable space: ± 0.2 to ± 0.5 K.
Temperature deviation spatially: ± 0.5 to ± 1 K.
Humidity fluctuation over time in the center of the usable space: ± 1 to ± 3 % RH.
Test chamber dimensions: height 950 mm, width 760 mm, depth 650 mm.
External dimensions: height 2025 mm, width 1090 mm, depth 2480 mm.
Rated voltage: 3/N/PE AC 400 V ± 10% 50 Hz.
Rated current: 24 A. Rated power: 16.0 kW.
Refrigerant: R452A.
Weight: approx. 900 kg.
Type: WK-480/40/10.
For your security as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components.
2. If necessary, new filling with legally compliant refrigerant.
3. Leak test with certificate.
4. After successful inspection, the chambers undergo a documented test run.
Condition: used.
Scope of delivery: (See image).
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
Listing
Borken
7,009 km
Temperature test chamber 200 liters
CTSTS-70/200-5/S -70°C bis +180°C
Call
Condition: excellent (used), CTS TS-70/200-5/S Temperature Testing Chamber
Manufacturer: CTS Clima Temperatur Systeme GmbH
Type: TS-70/200-5/S
Machine Type: Temperature Testing Chamber / Stress-Screening Testing Chamber
Test Chamber Volume: approx. 200 liters
For sale is a used temperature testing chamber from the manufacturer CTS.
The testing chamber is suitable for temperature testing, stress screening, environmental simulation,
material testing, quality assurance, as well as development and endurance tests.
Technical Data
Temperature Range: -70 °C to +180 °C
Temperature Change Rate (Heating): approx. 8 K/min
Temperature Change Rate (Cooling): approx. 6 K/min
Max. Heat Radiation at +20 °C: approx. 3500 W
Test Chamber Dimensions (approx.): 650 x 400 x 750 mm (W x D x H)
Housing Dimensions (approx.): 920 x 1345 x 1800 mm (W x D x H)
Weight (approx.): 550 kg
Power Connection: 400 V 3/N / 50 Hz
Power Consumption: 10.9 kW
Rated Current: 15.7 A
Protection Class: IP22
Refrigerant, Pre-cooling Stage: R404A
Refrigerant Quantity, Pre-cooling Stage: 2.5 kg
Refrigerant, Cooling Stage: R23
Refrigerant Quantity, Cooling Stage: 0.6 kg / 15 bar
Operating Pressure PS: 25 bar
Test Pressure PT: 20 bar
Equipment
Touch panel operation
Viewing window in the door
Stainless steel interior
Test chamber lighting
Side openings as shown in the pictures
Shelves / test chamber equipment as shown in the pictures
Over-temperature test specimen protection
Eurotherm safety controller
RS232 interface
Documentation / documents as shown in the pictures
Areas of Application
Temperature testing
Stress screening
Ledpfjzf Hi Hsx Abysrn
Environmental simulation
Material testing
Electronics testing
Quality assurance
Research and development
Scope of Delivery
1x CTS TS-70/200-5/S Temperature Testing Chamber
Shelves / test chamber equipment
Existing documentation / documents
Accessories as shown in the pictures
Condition
Used
Optical condition as shown in the pictures
Scope of delivery as shown in the pictures.
Subject to changes and errors in technical data as well as prior sale.
Listing
Borken
7,009 km
Temperature test chamber 600 liters
Vötsch KlimaprüfschrankVC 4060 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch VC 4060 Climate Testing Chamber
Ljdszf E E Tjpfx Abyjrn
Manufacturer: Vötsch Industrietechnik GmbH
Type: VC 4060
Machine Type: Climate Testing Chamber / Temperature Testing Chamber
Test Chamber Volume: approx. 600 liters
Control System: S!MCON / 32
Cooling: water-cooled
Refrigerant: R452A
For sale is a used climate testing chamber from Vötsch.
The testing chamber is suitable for temperature and climate tests, environmental simulation,
material testing, quality assurance, as well as development and stress tests.
Technical Data
Test Chamber Dimensions: approx. 800 x 800 x 950 mm (W x D x H)
Housing Dimensions: approx. 1090 x 1960 x 1995 mm (W x D x H)
Weight: approx. 600 kg net
Temperature Range: -40 °C to +180 °C
Temperature Change Rate (Heating): approx. 4.0 K/min
Temperature Change Rate (Cooling): approx. 3.0 K/min
Temperature Deviation (Time): ±0.1 to ±0.5 K
Temperature Deviation (Spatial): ±0.5 to ±2 K
Temperature Gradient: approx. 1 to 4 K
Climate Range (Temperature): -10 °C to +95 °C
Humidity Range: 10 % to 98 % RH
Humidity Deviation: ±0.1 to ±3 % RH
Temperature Deviation (Climate Operation, Time): ±0.1 to ±0.3 K
Temperature Deviation (Climate Operation, Spatial): ±0.5 to ±1.0 K
Temperature Gradient (Climate Operation): approx. 1 to 2 K
Power Connection: 3/N/PE AC 400 V ±10 % / 50 Hz
Rated Power: 7.8 kW
Rated Current: 15.0 A
Fuse: 16 A slow-blow, on-site
1 cable entry Ø 50 mm installed on the left
1 cable entry Ø 125 mm installed on the right
Test chamber made of stainless steel
Touch panel operation
Equipment
S!MCON / 32 control system
Touch panel operation
Interior made of stainless steel
Test chamber lighting
Side cable entries Ø 50 mm and Ø 125 mm
Shelving / test chamber equipment as shown in the pictures
Water-cooled system
Documentation / operating manual
Accessories as shown in the pictures
Application Areas
Temperature testing
Climate testing
Environmental simulation
Material testing
Electronics testing
Quality assurance
Research and development
Scope of Supply
1x Vötsch VC 4060 Climate Testing Chamber
Documentation / operating manual
Accessories as shown in the pictures
Condition
Used
Optical condition as shown in the pictures
Inspection possible by appointment
Note: The unit has been converted to use R452A refrigerant.
Scope of supply as pictured.
Subject to changes and errors in the technical data, as well as prior sale.
Listing
Borken
7,009 km
Stress test chamber
EspecEHS-221MD
Call
Condition: excellent (used), Espec
Here we offer an Espec (ThermoTec) stress test chamber.
External dimensions: W x H x D: 860 x 1795 x 1000 mm
Test chamber dimensions: W x H x D: 355 x 355 x 426 mm
2 x 46 liters
Voltage: 230 V 1/N 50 Hz
Rated current: 37 A
Fuses: 250 V, 2 x 3 A
Type: EHS-221MD
Temperature range: +105°C to +142.9°C
Humidity range: 75 to 100% RH
Temperature stability: -+ 0.5 °C
Lsdozfy N Tjpfx Abysrn
Pressure range: 0 to 2.0 kg/cm²
Heating/pressure build-up time: from 0 to 2.0 kg/cm² in approximately 60 minutes
390 kg
Condition: Used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
Listing
Borken
7,009 km
Temperature test chamber
VötschVTS³ 7018-5
Call
Condition: excellent (used), Vötsch
Type: VTS³ 7018-5
Water-cooled
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 900 mm x Depth 1550 mm x Height 1850 mm
Ljdpfxjzfg Uce Abyjrn
Temperature testing:
Temperature range: -70°C to +180°C
Temperature change rate: Heating 7.5 K/min
Temperature change rate: Cooling 7.5 K/min
Test chamber volume: 190 liters
Rated voltage: 400 V
Rated current: 20 A
Rated power: 9 kW
Weight: approx. 540 kg
Refrigerant: R404A and R23
For your safety as a buyer, please note the following information:
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerants
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications are reserved!)
We will be happy to answer any further questions you may have by phone.
Listing
Borken
7,009 km
Stress test chamber
EspecEHS-221M
Call
Condition: excellent (used), Espec
We are offering an Espec (ThermoTec) stress test chamber.
Overpressure and humidity tests at over 100 degrees Celsius in various modes.
Program capacity for 10 samples with 30 steps per sample.
A variety of safety mechanisms: overheating/overpressure protection, detection of water supply failure, complete door locking, and temperature sensor.
Saturated temperature range: 105 to 142.9°C.
Unsaturated temperature range: 105 to 132.9°C.
Lrsdszd Uy Djpfx Abyjn
Humidity range: 50 to 100% RH.
Nominal pressure: 0.196 MPa at 132.9°C and 100% RH.
External dimensions: Width 740 x Height 1553 x Depth 1000 mm.
Test chamber dimensions: Width 355 x Height 355 x Depth 426 mm.
Other features:
With rails and grid.
Test item connections inside the chamber.
Type: EHS-221M
Scope of delivery: See images.
300 kg
Condition: Used
Scope of delivery: (See image)
(Changes and errors in the technical data and specifications are reserved!)
We would be happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Temperature test chamber -20°C...+140°C
TIRATTRE 2001 S
Call
Condition: excellent (used), Here we offer a TIRA temperature testing chamber.
TIRA temperature testing chamber, air-cooled.
The chamber has the option for an external test box, including an external sensor connection, and can therefore also be used as an external temperature control unit.
Temperature range: -20°C to +140°C
Temperature stability over time: ±0.1°C to ±0.3°C
External dimensions: Width 860 mm x Depth 1500 mm x Height 2100 mm
Test chamber dimensions: Width 601 mm x Depth 545 mm x Height 692 mm
Electrical connection: 400V +6% / -10% 50Hz 3P+N+PE
Rated current: 10.0 (max. 17) A
Rated power: 5.2 (max. 9.0) kW
Net weight: 735 kg
Refrigerant: R404A / R23
Lrsdpfx Aszd Umqjbysn
Type: TTRE 2001S
For your safety as a buyer, please note the following information:
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We would be happy to answer any further questions you may have by phone.
Listing
Borken
7,009 km
Climate test chamber with humidity
WeissSB2/500/80 -75°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss climate test chamber.
Designation: SB2/500/80, water-cooled
Cold-heat operation: -75°C ... +180°C
Climate operation: +10...+95°C
Humidity range: 10...98 % RH
Temperature stability, over time: ± 0.2K
Humidity stability: ±1 % RH
Temperature change rate:
Cooling: approx. 1.4 K/min
Heating: approx. 2.5 K/min
External dimensions: Height 1980 mm, Width 1265 mm, Depth 1365 mm
Connections:
left side: ∅ 100 mm
right side: ∅ 50 mm
The connection voltage is:
400V/3Ph+N+PE/50 Hz
Power: 10.4 kVA
Weight: approx. 720 kg
Refrigerant: R404a / R23
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leakage test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Lredpfx Aozd Ultobyon
Type: SB2/500/80
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data and information are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Environmental test chamber -70°C to +180°C humidity
ThermotronSM-8-8200
Call
Condition: excellent (used), Here we offer you a Thermotron environmental test chamber.
Thermotron environmental test chamber, water-cooled
Working area volume: 227 liters
Temperature uniformity: All models 0.7°C
Temperature range: -70°C to +180°C
Temperature control tolerance: All models 0.3°C
Shipping weight: approx. 400 kg
Internal dimensions: Width 610 mm x Depth 610 mm x Height 610 mm
External dimensions: Width 890 mm x Depth 1240 mm x Height 1850 mm
Lrsdpszd Snrsfx Abysn
Humidity range: All models 10% to 98% RH
Humidity control: All models 2.5% RH
Heating time in minutes -65º to 71ºC: 17
Heating time in minutes -65º to 180ºC: 43
Heating time in minutes -40º to 85ºC: 16
Electrical requirements in full load amps 230/3/60: 19
Electrical requirements in full load amps 230/1/60: 25
Electrical requirements in full load amps 220/1/50: 27
Cooling time in minutes 85º to -40ºC: 32
Cooling time in minutes 71º to -65ºC: 54
Cooling time in minutes 180º to -65ºC: 72
Compressor size: (2) -2 Hp
Operating voltage: 400V 16.7 A
Type: SM-8-8200
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by phone.
Listing
Borken
7,009 km
Emissions test chamber
WEISSWT 5,1'/ + 18-45
Call
Condition: excellent (used), Weiss
Lodpfxozd Slkj Abyern
Here, we offer a Weiss emission test chamber.
Mini - SHED for diurnal loss measurements
Test chamber dimensions: Width 1600 mm x Depth 2140 mm x Height 2150 (usable 1600) mm
Housing dimensions: Width 1760 mm x Depth 3100 mm x Height 2790 mm
Maximum floor load: 250 kg
Operating temperature range: +18 °C ... +45 °C (at higher temperatures, SHED operation is only possible without a Tedlar bag)
Temperature range: +18 °C ... +45 °C
Temperature stability: ≤ ±1 K (over time)
Temperature change rate (heating and cooling): approx. 0.5 K/min, without test specimen
Duct connection (air inlet and outlet): ∅ 80 mm, in the rear wall of the chamber
Shut-off valve, gas-tight (air inlet and outlet): ∅ 80 mm, gas-tight, pneumatic operation; scope of supply: connecting flange of the shut-off valve
Cooling water consumption: approx. 0.8 m3/h
Voltage: 230/400 V; 3-phase + N + PE; 50 Hz
Rated power: 4.1 kW Rated current: 14.0 A
Weight: approx. 2500 kg
Type: WT 5.1'/ + 18-45
Condition: used
Sale from our location
Scope of supply: (Only the Weiss emission test chamber WT 5.1'/ + 18-45 Mini-SHED)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
Listing
Borken
7,009 km
Temperature test chamber
Heraeus VötschVTS 7033
Call
Condition: excellent (used), Heraeus Vötsch Temperature Test Chamber
Here we offer a Heraeus Vötsch temperature test chamber.
Vötsch Temperature Test Chamber VTS 7033, Water-Cooled
Temperature range: -70°C to +180°C
Temporal temperature deviation: ± 0.5 K
Spatial temperature deviation: ± 1.5 K
Heating rate: 7.5 K/min
Cooling rate: 6.5 K/min
Test chamber dimensions: Width 825 mm x Depth 800 mm x Height 870 mm
Housing dimensions: 1080 mm x 1710 mm x 1950 mm
Side openings: 12 cm and 13 cm
Voltage: 400V +6/-10%, 3/N, 50Hz
Rated power: 9.5 kW, Rated current: 22 A
Refrigerant: R404A / R23
Approx. 570 liters, Weight: 580 kg
For your safety as a buyer, please note the following information:
The following steps are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
Lsdpfx Ajzd Sf Dobyern
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Type: VTS 7033
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Temperature test chamber
RS-SimulatorenTS 150/75
Call
Condition: excellent (used), RS Simulators
Here we offer a temperature test chamber.
Ljdpfjzd Sfqsx Abysrn
Temperature Test Chamber, Water-Cooled
Temperature range: -70°C to +180°C
Time deviation: ±1 K according to DIN 50011 in an empty test chamber
Average heating time: approx. 3 K/min (according to DIN 50011 Part 12)
Average cooling time: approx. 3 K/min (according to DIN 50011 Part 12)
Test chamber dimensions: Width 530 mm x Height 530 mm x Depth 530 mm
External dimensions: Width approx. 900 mm x Height approx. 1800 mm x Depth approx. 1400 mm
Total power: approx. 6 kVA
Current consumption: 12 A
Main fuse: 3 x 16 A, slow-blow
Connection voltage: 3x400V/N/PE 50Hz
Weight: approx. 600 kg
Type: TS 150/75
Refrigerant: R404A / R23
Condition: used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data and specifications!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Climatic test chamber
Feutron3702/06
Call
Condition: excellent (used), Feutron
Type: 3702/06
Water-cooled climate test chamber
Technical data:
Nominal volume of test chamber: 2.0 m³
Dimensions: Test chamber exterior, with humidifier console
Width: 2970 mm, Height: 2370 mm, Depth: 1530 mm
Rear wall
Minimum insertion dimensions: Width: 2970 mm, Height: 2390 mm, Depth: 1550 mm
Test chamber: Width: 2000 mm, Height: 1000 mm, Depth: 1000 mm
Door: double-leaf, clear opening width 2000 mm, height 1000 mm
Viewing window, heated, 2 pieces, width 500 mm, height 600 mm
Feed-through opening, 1 piece, left side wall, diameter 75 mm
Temperature range: -40...100°C
Climate range: 10...95°C
Temperature difference, time-dependent ≤ ± 0.5...± 1.0 ΔN/K
Rate of change measured in the supply air, without load
Lrodpfx Abozd Sdmoyjn
Cooling up to 2.0 on average K/min
Heating up to 2.0 on average K/min
Humidity range: 10...95 % RH
Humidity difference, time-dependent ≤ ± 3.0 % RH
Dew point range, intermittently up to -5...95°C
Refrigeration system: water-cooled, semi-hermetic Bitzer system
Refrigerant: R507 (Μ-Κ1)
Climate and dryer refrigeration system: air-cooled / hermetic system
Refrigerant: R134a (Μ.ΚΚ)
Power supply:
Electrical connection: 400V 3/N/PE.AC, 50Hz
Power plug: CEE 5-pin, 32 A, with 5.0 m cable
Max. simultaneous power requirement: 10.0 kW
Supply line fuse: 3x 25, Char, C A
Protection class: IP20
Weight: 1300 kg
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Climate test chamber with humidity control
Feutron3707/06 Temp. -40°C bis 150°C
Call
Condition: excellent (used), Here we offer a Feutron climate test chamber.
Feutron Climate Test Chamber
Temperature
Temperature range: -40...90°C
Climatic range (without heat load): 10...85°C
Temporal temperature deviation during temperature operation: ≤ ± 0.5 K/min
Temporal temperature deviation during climatic operation: ± 1.0... ± 1.5 K/min
Change rates
Heating: avg. 2.0 K/min
Cooling: avg. 2.0 K/min
Standard IEC 1646 is achievable with testing, solar modules up to max. 160kg weight and nonlinear ramps (setpoint jump)
Drying
Air drying: condensation drying
Humidity
Air humidification: steam humidification
Humidity range: 10...95 % r.h.
Temporal humidity deviation: ≤ ± 3.0... ±5.0 % r.h.
Dew point range: 8...80.9°C
Test Chamber
Test chamber volume: 7.0 m³
Dimensions
Internal dimensions: Width 1500 mm x Height 2250 mm x Depth 2000 mm
Swing door DIN right, heated, Width 900 mm x Height 2100 mm
Observation window, heated, with blackout shutter and lockable: Width 500 mm x Height 600 mm
Feedthrough: 2x, right front side, Ø 75 mm
Irradiation unit, test chamber
Opening: 4x in left side wall for SC 2500, each 850 x 700 mm
Irradiated area when using SC 2500: 1200 x 1200 mm
Radiation intensity at 1.0 m wall distance: 1000 ± 10% W/m²
Lighting: 1x halogen lamp, 200W
Refrigeration system: Bitzer compressor, semi-hermetic, 2-stage, air cooled
Condenser: split condenser (outdoor installation, winter control)
Refrigerant: R507 / R23
Temperature control system
Coolant medium Tyfocor / water
Mixing ratio 50/50%
Coolant density: 1.072 kg/dm³
Filling quantity: approx. 80 dm³
Pyranometer
Temperature range: -40...150°C
Max. radiation absorption: 4000 W/m²
Spectral range (50% points): 305...2800 nm
Sensitivity (nominal): 7 µV/W/m²
Power supply, test chamber
Mains connection: 400V, 3/N/PE, AC, 50Hz
Connection type: hardwired
Max. simultaneous power demand: approx. 32.0 kW
Supply fuse: 3 x 63, Char C (A)
Power supply, SolarConstant
Lodezd Sdgspfx Abysrn
Mains connection: 400V, 3/N/PE, AC, 50Hz
Connection type:
Max. simultaneous power demand: approx. 30.0 kW
Supply fuse: 3 x 63, Char C (A)
Overall external dimensions of the test cell including: equipment room/control cabinet and control cabinet for SolarConstant 2500
External dimensions equipment room: Width 3440 mm x Height 2580 mm x Depth 2950 mm
/control cabinet: Width 2200 mm x Height 1830 mm x Depth 1100 mm
External dimensions condenser, split: Width 900 mm x Height 950 mm x Depth 2000 mm
Weight test chamber (total): approx. 2700 kg
Condenser empty weight: 153 kg
Weight: 2700 kg
Type: 3707/06
Condition: used
Scope of delivery: (see picture)
(Technical data and information are subject to change and errors!)
For further questions, we are happy to assist you by phone.
Listing
Borken
7,009 km
Climate test chamber 280 liters
FeutronKPK 200 Typ: 3416/16 +5 °C bis +100 °C
Call
Condition: excellent (used), We offer a climate test chamber for sale.
Air-cooled
Test chamber nominal volume: 280 liters
Dimensions:
External dimensions of the test chamber: 1500 x 2040 x 1075 mm
With fan motor and door removed: 1500 x 1940 x 925 mm
Test chamber: 720 x 690 x 560 mm
Door, clear opening: 720 x 690 mm
Viewing window, heated: 500 x 600 mm
Temperature range:
+5 to +100 °C
Heating rate: 4.0 K/min
Cooling rate: 0.6 K/min
Climate range: +10 to +95 °C
Humidity range: 10 to 95 % RH
Humidity change rate: ≤ ± 3.0
Water connection for humidifier: Tap water or distilled water, 20-liter reservoir
Power connection: 400 V 3/N/PE, AC, 50 Hz
Maximum power consumption: 6.3 kW
Lsdpfjzd R T Tex Abyern
Weight: 500 kg
Type: 3416/16
Refrigerant: R134a
For your peace of mind as a buyer, please note the following:
The following steps are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated instruments.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
Listing
Borken
7,009 km
Temperature test chamber 335 liters
VötschVTS 7034-5 -70°C bis +180°C
Call
Condition: excellent (used), Heraeus Vötsch Temperature Test Chamber
Here we offer you a Heraeus Vötsch temperature test chamber.
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
Temperature range: -70°C to +180°C
Temperature deviation (temporal): ±0.1 to ±0.5 K
Temperature deviation (spatial): ±0.5 to ±2.0 K
Temperature change rate (cooling): 5.0 K/min
Temperature change rate (heating): 6.5 K/min
Heat compensation at +20°C: 3000 W
Heat compensation at -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Test chamber volume: 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Ljdpfx Ajzd R Tgsbysrn
Rated power: 10 kW, Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Side feedthrough: 5.5 cm / 12.5 cm
Chamber is water-cooled
Refrigerant: R 452A and R 23
Weight: approx. 570 kg
Type: VTS 7034-5
For your security as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Temperature test chamber
WEISSWT1-600/70
Call
Condition: excellent (used), Weiss Temperature Test Chamber
Here we offer you a Weiss temperature test chamber.
Weiss Temperature Test Chamber, Water-Cooled
Technical Data:
Test chamber designation: WT1-600/70
External dimensions without hinges and door closure
Height 1980 mm, Width 1085 mm, Depth 1655 mm
Internal dimensions
Height 950mm, Width 800mm, Depth 800mm
Test chamber volume: approx. 600 liters
Cold/heat operation: -70 to 180°C
Temperature change per unit of time
Cooling: approx. 2.5 K/min
Heating: approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 9.1 kW
Rated current: 19 A
Permissible weight of test specimens
Total load of the shelf supports: 80 kg
Refrigerant: R 404A + R23
Weight: 600 kg
Type: WT1-600/70
For your safety as a buyer, please note the following information!
Lrsdpfx Abszd R Svjyon
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have on the phone.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
7,009 km
Temperature test chamber
WEISSWT-600/70
Call
Condition: excellent (used), Weiss Temperature Test Chamber
Here we offer a temperature test chamber.
Weiss Temperature Test Chamber, Water-Cooled
Technical Data:
Test chamber designation: WT-600/70
External dimensions with hinges and door lock:
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock:
Height 1995 mm, Width 1000 mm, Depth 1660 mm
Internal dimensions:
Height 950 mm, Width 800 mm, Depth 800 mm
Test chamber volume: approx. 600 liters
Cold / heat operation: -70°C to 180°C
Temperature change per unit of time:
Cooling down: approx. 2.5 K/min
Heating up: approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 9.1 kW
Rated current: 19 A
Fuse (customer-supplied): 32 A slow-blow
Permissible weight of test specimen:
Total load of the shelf supports: 80 kg
Test chamber floor: 80 kg, insert shelf: 40 kg
Refrigerant: R 404A/R23
Weight: 675 kg
Type: WT-600/70
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
Ledpozd R Drjfx Abysrn
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and information are subject to change!)
We are happy to answer any further questions you may have by phone.
Listing
Borken
7,009 km
Temperature test chamber, explosion-proof
CTST-30/950 Ex/I
Call
Year of construction: 2011, condition: excellent (used), CTS
Type: T-30/950 Ex/I
CTS Temperature Test Chamber, Explosion-Proof
Control – 32-bit controller
LCD control panel
Digital display for set and actual values
Numerical input of set values
Error messages in plain text
RS 232 interface
Free switching channels for product-side test specimen activation
Temperature Testing:
Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
Heating: 2 K/min
Ledezd Rzwopfx Abyorn
Cooling: 1.5 K/min down to -10°C
Thermal radiation: approx. 1000 W at +20°C
approx. 200 W at -25°C
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with a large flow rate of N2 until the
o2 content drops below 3%. Then, it switches to a base flow amount (approx. 10% of the large flow rate).
The nitrogen flow for the base amount is measured and displayed using a flowmeter and monitored via a limit switch.
O2 monitoring continuously extracts gas from the test chamber via a flame arrestor and passes it over an O2 sensor which checks the residual oxygen content of the extracted air.
Afterwards, the gas is returned to the test chamber via a second flame arrestor.
The extraction pump is monitored by a volumetric flow meter. Additional details can be found in the Dräger user manual in the appendix.
The gas system is currently deactivated!
All technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without irradiation, and without additional equipment.
Dimensions:
Test chamber volume: 950 liters
Test chamber dimensions: Height approx. 700 mm / Width approx. 900 mm / Depth approx. 1500 mm
External dimensions: Height approx. 2400 mm / Width approx. 1270 mm / Depth approx. 3125 mm
Operating data:
Electrical connection: 400V +6/-10 %, 3/N, 50 Hz
Nominal power: 21.6 kW
Rated current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, R 1/2" inner thread
Sound pressure level:
Listing
Borken
7,009 km
Climate test chamber 335 liters with humidity
VötschVC 4034 -40°C..+180°C
Call
Condition: excellent (used), Vötsch VC 4034 Climate Chamber / Temperature Chamber
Description:
For sale is a used climate and temperature chamber from the manufacturer Vötsch Industrietechnik.
This unit is suitable for demanding temperature and climate tests in research, development,
quality assurance, the electronics industry, automotive technology, as well as material and aging tests.
The test chamber has been converted to the modern refrigerant R452A and features a user-friendly
touch panel control.
Thanks to the large test chamber volume of approximately 335 liters, the system is suitable for both individual test specimens and
for extensive test setups.
Technical data:
Manufacturer: Vötsch Industrietechnik GmbH
Type: VC 4034
Test chamber volume: approx. 335 liters
Test chamber dimensions: approx. 580 x 765 x 750 mm (W x D x H)
External dimensions: approx. 780 x 1758 x 1800 mm (W x D x H)
Weight: approx. 515 kg
Temperature range: -40 °C to +180 °C
Temperature deviation over time: ±0.1 to ±0.5 K
Temperature homogeneity spatially: ±0.5 to ±1.5 K
Heating rate: approx. 3.2 K/min
Cooling rate: approx. 3.5 K/min
Climate operation:
Temperature range: -40 °C to +180 °C
Humidity range: 10 % to 98 % RH
Temperature deviation over time: ±0.1 to ±0.3 K
Temperature homogeneity spatially: ±0.5 to ±1.0 K
Refrigerant: R452A
Filling quantity: 2.5 kg
GWP: 2141
CO₂ equivalent: 5.35 t
ND max.: 22 bar(g)
HD max.: 25 bar(g)
Power connection: 3/N/PE AC 400 V ±10 % / 50 Hz
Rated power: 4.1 kW
Rated current: 12.5 A
Equipment:
Touch panel control
Programmable test sequences
Stainless steel interior
Viewing window in the door
Test chamber lighting
Air circulation system
Side feedthrough for measuring cables
Several stainless steel insert shelves
Air-cooled refrigeration system
Documentation available
Application areas:
Temperature testing
Climate testing
Material testing
Electronics testing
Aging tests
Environmental simulation
Quality assurance
Research and development
Automotive testing
Condition:
Used
Optical condition as shown in the pictures.
Maintenance and calibration stickers are present.
Refrigeration circuit converted to R452A.
Lrsdpfx Aszd Dm Hebyon
Scope of supply:
1x Vötsch VC 4034 Climate Chamber
Stainless steel insert shelves
Touch panel control unit
Documentation / Documents
Accessories as shown in the pictures
Subject to changes and errors in the technical data.
Subject to prior sale.
Listing
Borken
7,009 km
Climate test chamber 256 liters
MemmertCTC 256 -42 bis +190°C
Call
Condition: excellent (used), Memmert GmbH
Climate Testing Chamber / Temperature Testing Chamber
Used Memmert climate testing chamber, type CTC 256, for temperature and climate testing. This unit is suitable for environmental simulation, material testing, quality assurance, research and development, as well as stress and aging tests.
Technical data:
Manufacturer: Memmert GmbH + Co. KG
Type: CTC 256
Test chamber volume: approx. 256 liters
Test chamber dimensions: approx. 640 x 597 x 670 mm (W x D x H)
Housing dimensions: approx. 898 x 1100 x 1730 mm (W x D x H)
Weight: approx. 320 kg
Temperature range: -42 °C to +190 °C
Heating rate: approx. 3.35 K/min
Cooling rate: approx. 2.8 K/min
Ljdpfxszd Dche Abyorn
Humidity function available
Refrigerant: R404A
Rated cooling capacity: 2.53 kW
Max. operating overpressure: 30 bar
Mains connection: 3/N/PE AC 400 V / 50 Hz
Rated power: approx. 7.0 kW
Rated current: approx. 10.6 A
Equipment
Programmable controller
Viewing window
Stainless steel interior
Air circulation system
Ethernet interface
Printer connection
Alarm contact
230 V service socket
Shelf insert
Documentation available
Scope of delivery
Memmert CTC 256 climate testing chamber
Shelf insert
Water canister
Documentation / test report
Accessories as shown in the pictures
Condition
Used, optical condition according to the pictures.
(Changes and errors in the technical data are subject to change!)
Subject to prior sale.
We make it easier for you to find: "thermal shock test chamber"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month











































































































































































































































