Used Chamber Furnace for sale (2,768)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing

6,955 km
Tempering continuous furnace
VEI-EngineeringVEI DLO_EB
Call
Year of construction: 2015, condition: used, external dimensions:
lenght: 3900 mm
width: 1320 mm
height: 1090 mm (above base frame)
muffle lenght: 3960 mm
mesh belt: 480 mm width
Hnjdpeclupdjfx Aabou
clear height 140 mm
max. furnace area temperature: 750°C
max. temperature inside the muffle: 700°C
water cooled ventilators : 3
electrical connected loads:
three-phase: 3 x 400 V, 50 Hz
power consumption: 75 kVA
heating power, 3 zones each: 24 kW = 72 kW
PLC : Siemens S7
Listing

7,009 km
Climate test chamber 1300 liters with humidity control
VötschVCS 7130-15 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Model: VCS 7130-15
Vötsch Climate Test Chamber, Water-Cooled
Temperature Test Data:
Temperature range: -70°C to 180°C
Temporal temperature deviation at center of workspace: ±0.3 to ±0.8 K
Spatial temperature deviation: ±0.5 to ±2 K
Temperature gradient: 1 to 4 K
Temperature change rate:
Heating: 16 K/min
Cooling: 14.5 K/min
Climate Test Data:
Temperature range: +10°C to +95°C
Humidity range: 10 to 98% RH
Temporal temperature deviation at center of workspace: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1 K
Temperature gradient: 1 to 2 K
Temporal humidity fluctuation at center of workspace: ±1 to ±3% RH
Maximum heat compensation: 8000 W
Enclosure dimensions:
External dimensions with hinges and door lock:
Height: 1995 mm, Width: 1680 mm, Depth: 1855 mm
External dimensions without hinges and door lock:
Height: 1995 mm, Width: 1300 mm, Depth: 1855 mm
Internal dimensions:
Height: 950 mm, Width: 1100 mm, Depth: 950 mm
Test chamber volume: approx. 1300 liters
Feedthroughs:
The test chamber is equipped with feedthroughs on both the right and left sides. These allow for test leads and testing devices to be routed into the chamber.
1 x R1 NW 125 mm
1 x R1 NW 140 mm
1 x L1 NW 50 mm
Test chamber illumination:
Halogen bulb 24V, 50W
Hnjdpfxjwvgwbo Aabju
Power supply: 3/N/PE AC 400V ±10% 50Hz
Rated power: 44.0 kW
Rated current: 63.0 A
Customer-provided fuse: 100 A slow-blow
Maximum heat output to the environment: 2.2 kW
Permissible test item weight:
Total load on shelf supports: 100 kg
Test chamber floor: 150 kg, Removable shelf: 50 kg
Refrigerants: R 404A/R 23
Weight: 1900 kg
For your security as a buyer, please note:
The following steps are carried out in advance on our chambers offered for sale:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Subject to changes and errors in the technical data and specifications!)
We are happy to answer any further questions by phone.
Listing

6,506 km
Glass tempering furnace
TAMGLASS / GlastonHTF ProE-2442-CTS-10-R
Call
Condition: good (used), Year of construction: 2000, functionality: fully functional, type of input current: AC, Equipment: documentation/manual, Glass tempering furnace
Hnedjxaugcspfx Aabsu
TAMGLASS / GLASTON, HTF ProE-2442-CTS-10-R
2400 x 4200 mm, Right – Left
Year: 2000. With convection (Low-E glass)
Noise reduction cabin included.
400 V, 50 Hz, total power: 1210 kW (heating 630 kW, motors 580 kW)
In good technical condition. Inspection is possible by appointment.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing

6,807 km
Horizontal Packing Machine With Chamber Vacuumizer
AMTECHPFS CHAM-VACU 1
Call
Year of construction: 2025, condition: new, Sample system for filling wet coleslaws, sauerkraut, red cabbage into prefabricated bags including vacuuming of the bags. Rotary type volume dosing station with the special feature that the product is pressed into the bag by a piston cylinder. The filled bags are then transferred to the rotating vacuum and sealing station. 10 individual chamber vacuumers - particularly suitable for products containing high liquid - ensure an excellent vacuuming result. Thermal transfer printer and product infeed unit included. PLC controlled, operation via touch screen. Suitable for a wide range of pouches such as composite and single-layer aluminium, PE, BOPP and PP films, paper, etc. - Specifications: Filling range: 20-1000g; max. number of machine cycles in neutral: 80 cycles/min; bag dimensions: W(80-160)xL(80-240)mm; dimensions of the machine LxWxH: 2100x1400x1700mm. Please note: This is only a sample system. The dosing unit is selected according to the product requirements. Specifications may differ and depend on the final layout.
Hedpfx Aaev Nlnmsbenu
Please note that our new prices are often below the usual used prices. Please feel free to inquire and tell us your packaging task. - Usually 30-50 different new machines are available immediately from stock. In addition, we have very short delivery times from approx. 3 weeks for customized machines. Deviations from the sample photo are possible. - All machines are available with full warranty.
Listing

7,016 km
Air-cooled climatic test chamber
VötschVC 0033
Call
Condition: good (used), Climatic Test Chamber +10°C to +90°C, Air-Cooled
The test chamber is designed and built for climatic testing within its operating range.
Test procedures that determine the influence of temperature and humidity on material properties
and functional reliability of the test specimen can be performed.
The test chamber can be operated in manual mode (fixed-value mode) or automatic mode.
The EDIT program can be used to program extensive climatic tests and save a maximum of 99 test programs.
These test programs are run in automatic mode.
The test chamber can be controlled during operation via the RS 232 interface with a computer and the TSI software or in ASCII mode.
The operating temperature limiter protects the test specimen from excessively high temperatures.
To protect the test specimen, the upper and lower temperature limits can also be set on the terminal.
Manufacturer: Heraeus Vötsch
Type: VC 0033
Specifications for temperature tests:
Temperature range: +10°C to +90°C
Humidity range: 30 - 95%
Rated voltage: 230V +6/-10% 1/N 50Hz
Rated power: 2.7 kW
Rated current: 12 A
Refrigerant: R 404A
Test chamber volume: approx. 333 liters
Humidity range:
Humidity range for normal operation (ranges 1 and 3) with a dew point limitation of +5°C
Humidity range 3 is omitted if additionally equipped with a capacitive humidity measurement system
Tolerances for standard climate conditions
23°C/65% RH
Temperature ±0.1 K
Humidity < ±1.5%
Hnjdpfsxbnkwex Aabju
85°C / 85% RH
Temperature ±0.1 K
Humidity
Discover more used machines
Listing

6,760 km
Continuous Furnace
Lincoln1164-C01-A-K1835
Call
Condition: ready for operation (used), A small tunnel oven for pizza production is available. Heating capacity: 10kW, temperature range: 120°C-300°C, conveyor time: 90s-20min, conveyor belt dimensions X/Y: 460mm/1320mm, baking area X/Y: 460mm/610mm, production capacity for 26cm pizzas: approx. 70 pieces/h, machine dimensions X/Y/Z: approx. 1450mm/1000mm/450mm, weight: approx. 170kg. An on-site inspection is possible.
Hnedpfx Aoxapgqoabou
Listing

5,404 km
EDMUND-ERDMAN GLASS TEMPERING FURNACE
EDMUND-ERDMAN2007 Vitromod
Call
Condition: used, Year of construction: 2007, 2 (two) chambers
Max. size: 2580 X 4200mm
Min. size: 100 X 200 mm
Thicknes: 4-19mm
LowE
Hedpfeiqn Aiox Aabjnu
The line is currently dismantled and stored in our warehouse as shown on the pictures.
Listing

7,009 km
Temperature test chamber 190 liters
VötschVT 7018 -70°C bis +180°C
Call
Operating hours: 630 h, condition: excellent (used), Vötsch
Model: VT 7018
Air-cooled temperature test chamber
Only approx. 630 operating hours (read out)!
Test chamber dimensions: Width 580 x Depth 450 x Height 750 mm
External dimensions: Width 865 x Depth 1280 x Height 1780 mm
Test chamber volume: approx. 190 liters
Technical specifications for temperature tests:
Temperature range: -70 °C to +180 °C
Temperature deviation in steady state, according to IEC 60068-3-5
depending on the test chamber temperature
temporal ±0.1 to ±0.5 K
spatial ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min.
Cooling: 2.3 K/min.
Thermal compensation max. 1000 W
Tube port L1: DN 50 mm
Tube port L2: DN 125 mm
Tube port R1 R2: DN 125 mm
Hjdew Nqimjpfx Aabonu
Electrical connection:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 5.9 kW
Rated current: 12 A
Protection: 16 A time-lag, to be provided by customer
Weight: approx. 460 kg net
Refrigerants: R 404A and R 23
Important safety information for you as a buyer!
The following points are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (See image)
(Subject to change and errors in technical data!)
We are happy to answer further questions by phone.
Listing

6,695 km
Hot air furnace, workshop furnace, hall heater
FabbriF28 c.v. mit Komfort Kit
Call
Condition: new, Year of construction: 2024, Firing chamber output: 34 kW
Working power: 29 kW
New appliance, original packaging: Yes
Hot air blower, flue gas blower, control with digital display: included
Hot air conveying pipes: 2 x 180 mm with 2 freely rotatable plug-in bends
Intake filter / supply air filter: large-surface supply air filter without power loss / included
Smoke outlet diameter: 160 mm
Firebox length: 500 mm
Firebox width: 400 mm
Firebox height: 590 mm
Air flow : 2200 m³/h
Hjdpfopkwhqsx Aabenu
Power consumption: 400W
designed for room volume: 500 m³
Area to be heated: 100/150 m²
Stove height without hot air conveying pipes: 1560 mm
Oven width: 550 mm
Oven length without flue gas fan: 920 mm
Weight: 200 kg
Listing

6,957 km
Vacuum truck
ScaniaP320 6x2 with Terberg Viking 2-Chamber
Call
Condition: used, mileage: 16,000 km, Year of construction: 2023, Serial number: YS2P6X2000569xxxx
Please contact ATS Norway for more information
Please provide reference number upon request: 21031
Chassis:
Scania P320 6x2*4 (steerable tag axle)
Engine: 320 hp, 9,000 ccm, 6-cylinder, Euro 6
Cab type: CP14L
Wheelbase: 3,550 mm
Allison GA866 automatic transmission
Air suspension front and rear
Black leather seats
Scania Infotainment Premium
Gearbox and engine PTO
Body: Terberg Viking Dual-Chamber
Total volume: 17.2 m³
Left chamber: 11.2 m³
Right chamber: 6 m³
Fully automatic bin lifter
Prepared for dynamic weighing and RFID on chamber
Control panels on both sides (rear)
Pick-up function for bins
Compatible with:
140–1000 L bins on wide side
140–360 L bins on narrow side (can be equipped for 660 L or split bins)
Can empty split bins
2 LED rotating warning lights (rear, with guards)
LED tail lights
Cycle time:
2-wheel bins: max 8 sec
4-wheel bins: 12–15 sec
Hydraulically operated tailgate
Auto lift of seal strip during reversing or speeds > 7 km/h
Auto-retractable step with handhold (right side)
Integrated underrun protection
Separate hydraulic systems for each chamber
Color: White
Includes broom and shovel
Km: 16000
HK: 319
Technical approved: Yes
EU-approved until: 20.12.2025
Own weight: 18100
Total Weight: 27000
Payload: 8825
Width: 253
Hnjdpfx Aew Ia D Rsabsu
Length: 948
Model: P320
Gearbox: Automatic
Listing

7,016 km
Drying cabinet Chamber oven
VötschVTU 100/150
Call
Condition: good (used), Vötsch VTU 100/150 heating and drying cabinet
Manufacturer: Vötsch
Type: VTU 100/150
Nominal temperature: 250 °C
Usable volume: 1500 m³
Total load: 400 kg
Nominal power: 27 kW
Connected load: 29 kW
Nominal current: 42 A
Mains connection: 400 V, 3 PH+N PE, 50 Hz
Weight: 780 kg
Microprocessor-controlled temperature and program controller
Jumo two-point controller
Digital display of setpoint/actual temperature, plain text display
Easy loading of the device floor via folding ramp
Dimensions
Interior: (W x H x D) 1000 x 1500 x 1000 mm
External: (W x H x D) 1840 x 2389 x 1450 mm
Hnodpfxjxbgt De Aabsu
You can find more items—new and used—in our shop!
International shipping costs on request!
Buy-it-Now

6,531 km
Tabletop quartz tube furnace
ATV Techologie GmbHPEO 601
Condition: used, Year of construction: 2007, operating hours: 6,383 h, functionality: fully functional, machine/vehicle number: 172, ATV Technologie GmbH Tabletop Quartz Tube Furnace, PEO 601
Model: PEO601
Condition: Used
Technical Data:
230/400V AC
50Hz
16A
6.3kW
20-1000°C
General Information:
Year of manufacture: 2007
Serial number: 172
Operating hours: 6,383
Compact tabletop unit for Plasma Electrolytic Oxidation (PEO) or Micro Arc Oxidation (MAO)
Equipment for firing or annealing electronic components
Designed for surface treatment processes of aluminum, magnesium, and titanium
Hnedpfxjw Dbrvo Aabou
Produces ceramic coatings on metal surfaces that are particularly hard, corrosion-resistant, and temperature-resistant
Programmable firing furnace with precise temperature control
Maximum temperature range: up to approx. 1,000°C
Heating rate: approx. 100°C/min
Processing chamber: diameter approx. 112 mm (4½″), suitable for wafers up to 100 mm
Application in semiconductor, micro, and nanosystem technology
Ideal for research, development, and small series production
Microprocessor-based control with adjustable parameters (e.g., voltage, current, time)
Integrated control panel with digital displays
RS-232 interface for process data monitoring and control
Optional connection for process gases (e.g., N₂, H₂)
Accessories:
Scope of delivery as shown in the photos
Listing

6,147 km
Nabertherm N 450 furnace
NaberthermN450
Call
Condition: excellent (used), Nabertherm N450 ceramic firing kiln, maximum temperature 1280 degrees C.
German-made kiln.
The kiln is equipped with a very intuitive controller with 6 programs.
New spirals have been installed in the kiln, which guarantee the achievement of maximum temperature.
Chamber with a capacity of 450 liters.
Chamber dimensions:
Height 100 cm
Width 60 cm
Depth 75 cm
External dimensions
Height 182 cm
Hsdpfx Aaowdzt Hebenu
Width 103 cm
Depth 145 cm
Power supply 400 V
Power 24 kW
Maximum temperature 1280 degrees C
Kiln in very good condition.
Listing

7,009 km
Climate test chamber 600 liters with humidity
WeissWK3-600/70 -70°C bis +180°C
Call
Condition: excellent (used), Weiss
Model: WK3-600/70
Climate Test Chamber, Water-cooled
Specifications for temperature testing:
Temperature range: -70°C to +180°C
Temperature change rate:
Heating: 4.0 K/min
Cooling: 2.5 K/min
Temperature deviation:
Temporal: ±0.1 to ±0.5 K
Spatial: ±0.5 to ±1.5 K
Heat compensation: max. 2500 W
Specifications for climate testing:
Temperature range: +10 to +95 °C
Dew point temperature range: -3 to +94°C
Humidity range: 10 to 98% r.h.
Temperature deviation (temporal): ±0.1 to ±0.3 K
Temperature deviation (spatial): ±0.5 to ±1 K
Humidity deviation (temporal): ±1 to ±3% r.h.
Temperature uniformity (spatial): ±0.5 to ±1.0 K
Heat compensation: max. 500 W
Test chamber volume: 600 liters
Test chamber dimensions (H x W x D): 950 mm x 800 mm x 800 mm
External dimensions (H x W x D): 1998 mm x 1000 mm x 1745 mm
Feedthrough diameters: NW 125 mm and NW 50 mm
Operating data:
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal power: 9.1 kW
Nominal current: 19.0 A
Refrigerant: R 452A & R23
Hnedpfx Aew Nqhpeabsu
Weight: 680 kg
Important safety information for buyers!
The following procedures are carried out on all chambers we offer prior to delivery:
1. Functional check and replacement of necessary components
2. If necessary, the chamber is refilled with refrigerant in compliance with applicable laws
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Specifications subject to change and possible errors!)
If you have further questions, feel free to call us.
Listing

6,695 km
Hot air furnace, workshop furnace, hall heater
FabbriF55 c.v.
Call
Condition: new, Year of construction: 2024, Firing chamber output: 49 kW
Working power: 45 kW
New appliance, original packaging: yes
Hot air blower, flue gas blower, control with digital display: included
Hot air conveying pipes: 2 x 200 mm with freely rotatable plug-in bends
Smoke outlet diameter: 180 mm
Firebox length: 660 mm
Firebox width: 480 mm
Firebox height: 600 mm
Air flow : 3500 m³/h
Power consumption: 550 W
designed for room volume: 1000 m³
Area to be heated: 200/250 m²
Stove height without hot air conveying pipes: 1750 mm
Oven width: 700
Oven length without flue gas fan: 1150
Hedjk Utrdopfx Aabjnu
Weight: 305 kg
Listing

6,679 km
(2x) Climate chamber for stability testing
ThermoTEC / VIESSMANNWL80
Call
Condition: good (used), Year of construction: 2005, functionality: fully functional, (2x) Climate chamber for stability tests
The system for storing stability samples consists of 2 climate chambers. 2 climate chambers are supplied by an electrical control cabinet and have separate circuit diagrams.
The climate chambers are based on cooling cells from Viessmann. The climate chambers are dimensionally identical and equipped with stainless steel shelves.
The climate chambers were connected to a measured value recording system. This is currently not available for the system. However, a connection to a building management system is basically possible and prepared.
The entire system was taken out of service in 2024 and finally qualified. The qualification documents can be made available on request.
The delivery and installation of the system as well as the technical service were carried out exclusively by ThermoTEC.
The client offers the objects mentioned EXW
Ex Works "ex works". This means that the dismantling and loading of the objects is the responsibility of the buyer.
The system essentially consists of:
2 constant climate chambers made of 80mm PU elements, stainless steel floor and single-leaf revolving door with frame heating
2 chamber fittings for air conditioning consisting of:
-Fans for circulating the chamber air
-Direct evaporation register with refrigerant R404A, for cooling and dehumidification
-Electric resistance heating 2*1.5kW
Cold steam inlet hoses from the ultrasonic humidifier
2 air-cooled refrigeration condenser units for cooling and dehumidifying the
climate chambers.
2 ultrasonic humidifiers with an output of 1kg/h
Switch cabinet for controlling and regulating the climate chambers
The circulating air of the constant climate chambers is sucked in via the air conditioning unit, processed and blown out via the front.
The temperature and humidity sensor mounted in the intake area transmits the actual values of the test room to the respective control circuit of the climate chambers.
An independent process controller is installed in the control cabinet front for each control circuit (temperature/humidity).
The controllers control the following functions as required:
> HEATING with electric resistance heating
> COOLING with refrigeration unit and direct evaporation
> HUMIDIFICATION with ultrasonic humidifier
> DEHUMIDIFICATION with refrigeration unit and direct evaporation
The climate chamber temperature and humidity are controlled automatically.
Hnsdpfx Aajvpu Tlsbou
Cell type: Tecto cooling and deep-freezing cell Standard WL80 VIESSMANN
Dimensions of the climate chambers (KK) 2 each:
Outside (WxDxH): 2100 x 3000 x 2310 mm
Door dimensions (WxH): 800 x 2000 mm
Inside (WxDxH): 1940 x 2840 x 2140 mm
Climate chamber 1 25°C/60%RH
- A0429_00
- Year of construction: 2005
Climate chamber 2 25°C/60%RH
- A0430_00
- Year of construction: 2005
Listing

7,016 km
Climate test chamber with seat pulsator
WeissSD 1400/+20 DU
Call
Condition: good (used), Weiss Climatic Test Chamber with Seat Pulsator
Manufacturer: Weiss
Hsdpsxbgrgofx Aabsnu
Type: SD 1400/+20 DU
Test Chamber:
Material: Stainless steel
Dimensions
Height approx. 800 mm
Width approx. 2000 mm
Depth approx. 900 mm
Capacity: 1440 liters
Outer casing
Material: Double-coated Zincor sheet
Dimensions
Height approx. 2000 mm
Width approx. 2200 mm
Depth approx. 2000 mm
HxWxD 2000 x 2200 x 2000 mm
Paint finish: Light gray (RAL 9002)
Double-leaf door: hinged on the left and right
Equipment:
Tubing in the floor and ceiling: 2 each, NW 100 mm, for installing the pulsator tables
Tubing in the the side walls: 1 each, left and right, 100 mm
Cooling unit: Air-cooled
Control: Digital measurement and control system DMR
Basic control panel: Integrated into the main switch panel
Interface: RS 232 C, for connection to a PC
Software: Operating software for MS Windows
Performance data:
Temperature range without air conditioning: +20...+100 °C
Temperature stability without air conditioning: +0.2 ... t0.5 K (over time) depending on the range, in steady state
Temperature range with air conditioning: 20...+95 °C
Temperature stability with air conditioning: +0.2 ... +0.5 K (over time) depending on the range, in steady state
Dew point range: 20...+94 °C
Humidity range: 10...98 % RH
Humidity stability: +3 ... +5 % RH depending on the range, in steady state
Temperature change rate measured in the exhaust without a test specimen and without load
- Cooling: 0.5 K/min on average, between +100 and +20 °C
⁃ Heating: 0.5 K/min. On average, between +20 and +100 °C
The performance specifications refer to an ambient temperature of max. +25 °C and the specified nominal voltage.
For proper operation of the system, the ambient temperature must be between +10 and +35 °C.
Seat test device with steel construction for placing and attaching to the climatic test chamber, including:
• 2 pneumatic weight lifting devices (150 mm stroke) for changing test specimens, 12 weights of 5 kg each
• 1 base frame in mild steel welded construction for attaching to the underside of the climatic test chamber. This frame is equipped with removable panels on all sides and has two hinged doors for adjusting the eccentricity. These doors have safety switches.
• 2 eccentric discs with bearings and tachometer, 2 connecting rods, 2 ball bearings,
• 2 mounting tables, perforated, 20 mm grid, 650 x 650 mm, for attaching the test specimens, made of aluminum, thickness min. 10 mm
• 2 mounting plates, perforated, 20 mm grid, 200 x 200 mm, for attaching the buttocks simulation
• 2 stainless steel 60° load rods (The connection to the test specimen is not included in our price, but can be offered subsequently upon precise specification.)
• 2 three-phase motors, 2 belt drives with tensioning devices,
• 1 pneumatic control unit with 2 manual valves, a filter-regulator unit, and a shut-off valve. 1 electrical control cabinet with 2 SEW frequency converters, hand switches, emergency stop button, 2 on/off switches, 2 speed indicators, 2 potentiometers for speed adjustment, 2 pre-selected load changers with zero position and shutdown.
Technical specifications:
Frequency: 100-1000 strokes/minute
Load: 2 x 45 g
Stroke: 0-40 mm
Load from above: 450 N each
You can find more items - new and used - in our shop!
International shipping costs upon request!
Listing

7,009 km
Climatic test chamber shaker chamber 2160 liters
WeissWK3-2200/40/5/V -40°C bis +180°C
Call
Condition: excellent (used), Weiss
Type: WK3-2200/40/5/V
Weiss Climate Test Chamber, Water-Cooled
Specifications for Temperature Testing:
Temperature range: -40°C to +180°C
Temperature change rates:
Heating: 6.0 K/min
Cooling: 11.5 K/min
Temperature deviation:
Temporal ± 0.8 K
Spatial ± 2.0 K
Heat compensation max. 8000 W
Specifications for Climatic Testing:
Temperature range: +10°C to +95°C
Dew point temperature range: +4°C to +94°C with closed floor element
Humidity range: 10 to 95% rH
Temperature deviation (temporal): ± 0.3 K
Humidity deviation (temporal): ± 3% rH
Temperature uniformity:
Spatial ± 1.0 K
Heat compensation max.: 500 W
Test chamber volume: 2,160 liters
Hnodpfew I Rxrsx Aabju
Test chamber dimensions: Height 1,115 mm, Width 1,400 mm, Depth 1,400 mm
External dimensions (lowered): Height 2,318 mm, Width 1,860 mm, Depth 3,658 mm
External dimensions above shaker: Height 2,710 mm
External dimensions max. stroke height: 3,038 mm
Exchangeable floor dimensions: Width 1,600 mm, Depth 1,504 mm
Operating Data:
Rated voltage: 3/N/PE AC 400V +10% 50Hz
Rated power: 38.0 kW
Rated current: 63.0 A
Customer-side fuse: 80 A slow-blow
Refrigerant: R 404A
Weight: approx. 2,100 kg
Important information for your safety as a buyer:
The following points will be carried out on the chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. If required, refilling with refrigerant compliant with legal regulations
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and errors excepted!)
We are happy to answer any further questions you may have by phone.
Listing

6,695 km
Hot air furnace, workshop furnace, hall heater
FabbriF55 c.v. mit Komfort Kit
Call
Condition: new, Year of construction: 2024, Firing chamber output: 49kW
Working power: 45kW
New appliance in original packaging: Yes
Hodpfxepn Nyzo Aabsnu
Hot air blower, flue gas blower, electronic control with digital display: included
Supply air filter, recirculation air intake filter: large-surface supply air filter without power loss / included
Hot air conveying pipes: 2 x 200mm with plug-in freely rotatable 90° bends
Smoke outlet diameter: 180mm
Firebox length: 660mm
Firebox width: 480mm
Firebox height: 600mm
Air flow : 3500m³/h
Supply air filter: Yes, large-surface supply air filter without power losses
Power consumption: 550W
designed for room volume: 1000m³
Weight: 310 kg
Listing

7,016 km
Weathering test device Test chamber
HeraeusXenotest 1200 CPS
Call
Operating hours: 3,888 h, condition: good (used), Heraeus Xenotest 1200 CPS weathering tester
Xenon device for testing the lightfastness and weather resistance of materials under simulated conditions
Hodsxal Haepfx Aabenu
Electrical connection
Voltage: 400 V
Nominal current: 50 A max.
Connected load: 33 kVA max.
Power consumption of xenon lamps: 2.8 - 6 kW per lamp
Compensation: 3 capacitors, 50 uF each
Operating hours: 3888
You can find more items - new and used - in our shop!
International shipping costs on request!
Listing

7,009 km
Climate test chamber 600 liters
WeissWK3-600/70 -70°C bis +180°C
Call
Condition: good (used), Weiss
Type: WK3-600/70
Hnedpfew Inmmjx Aabeu
Climate Test Chamber, Water-Cooled
Specifications for Temperature Testing:
Temperature range: -70°C to +180°C
Temperature change rate:
Heating: 4.0 K/min
Cooling: 2.5 K/min
Temperature deviation:
Over time: ±0.1 to ±0.5 K
Spatially: ±0.5 to ±1.5 K
Heat compensation max.: 2,500 W
Specifications for Climate Testing:
Temperature range: +10 to +95 °C
Dew point temperature range: -3 to +94°C
Humidity range: 10 to 98 % rH
Temperature deviation over time: ±0.1 to ±0.3 K
Temperature deviation spatially: ±0.5 to ±1 K
Humidity deviation over time: ±1 to ±3 % rH
Temperature uniformity (spatial): ±0.5 to ±1.0 K
Heat compensation max.: 500 W
Test chamber volume: 600 liters
Test chamber dimensions: Height 950 mm, Width 800 mm, Depth 800 mm
External dimensions: Height 1,998 mm, Width 1,000 mm, Depth 1,745 mm
Operating Data:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 9.1 kW
Rated current: 19.0 A
Refrigerant: R404A & R23
Weight: 680 kg
Important information for you as the buyer:
The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After a successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Specifications subject to change. Errors and omissions excepted!)
If you have any further questions, we are happy to answer them by phone.
Trust Seal
Dealers certified through Machineseeker

Listing

7,016 km
Large-scale climate test chamber
VötschVCZ 04032
Call
Condition: good (used), Large-scale system for climate tests with S!MCON control
Design
The system consists of the following main components:
- Walk-in, insulated test room
Hnedjw U Sv Espfx Aabeu
- Air treatment room
- Machine unit
- Air conditioning system
- Control cabinet
Test room
The fixtures in the test room are made of corrosion-resistant material.
The test room can be illuminated, is walk-in, and has a condensate and cleaning drain.
Air treatment room
The air treatment room is located behind the air baffle in the insulated interior.
It contains the following components necessary for temperature control and is accessible via easily removable panels.
- Test room fans
- Heat exchangers
- Electric heaters
- Ventilation and exhaust system
- Temperature sensors
In the air treatment room, the air is tempered (cooled/heated), humidified and dehumidified, and circulated by fans.
The air is drawn in under the ceiling and expelled at floor level.
Sensors
The temperature and humidity sensors are located behind the air baffle in the air treatment room.
Machine Unit
The machine unit, consisting of refrigeration units, supplies the air treatment room with the required energy.
Climate System
The climate system consists of:
- Steam humidifier
- Dehumidification evaporator
Technical Data
Test chamber volume: approx. 32 m³
Direct temperature range: -40 to +100°C
Temperature fluctuation over time in the center of the usable space: +/- 0.5 to +/- 1
Temperature change rate
Heating: from -35°C to +50°C at 3 K/min
Cooling: from +85°C to +85°C at 2 K/min
from +80°C to -40°C at 1 K/min
Data for climate testing
Temperature range: 10 to 95°C
Humidity range: 10 to 95% RH
Dew point range: 5 to 93°C
Temperature fluctuation: +/- 5°C
Humidity fluctuation: +/- 3 to +/- 5% RH
Cooling water specifications
Connections
Inlet: 2 x 1 1/2" RH
Return: 2 x 1 1/2" RH
Consumption at full load: max. 16 m³/h
Maximum load on the test chamber floor: 10,000 N/m²
Nominal voltage: 3/N / PE AC 400 V 50 Hz
Nominal power: 97 kW
Nominal current: 148 A
Dimensions:
Test chamber: Width 3.60 m, Height 2.20 m, Depth 5 m
Climate chamber divided for transport at a specified location (approx. 2.50 m).
Find more items – new and used – in our shop!
International shipping costs on request!
Listing

7,009 km
Salt spray chamber corrosion test cabinet
VLMCC 1000-FL HL V.745.672.430 1000 Liter
Call
Condition: excellent (used), VLM
Type: V.745.672.430 Model CC 1000-FL HL
Corrosion Test Chamber for Salt Spray Tests
Hnsdpfx Asw H Aatsabou
Specifications:
Test Chamber Volume: approx. 1000 L
Test Chamber Dimensions (W x D x H1/H2): 1400 x 800 x 800/1020 mm
Door Opening Dimensions (W x H): 1300 x 680 mm
External Housing Dimensions (W x D x H): 2162 x 995 x 2080 mm
Operating Temperature Range: 5°C above ambient to +80°C
Heavy-duty Version for loads up to 350 kg
Process Control: Beckhoff PLC, Color Touchscreen Display, 50 program memory locations for test procedures, 50 memory locations for test segments, ramps: humidity-temperature throughout the entire working range, Ethernet connection
Electrical Connection: 400 V, 50 Hz, 5900 W
Mains Water: at least 2.5 bar, 3/4" tap connection with external thread for ion exchanger cartridge connection
Compressed Air: 7–8 bar
Wastewater: Siphon / 30 mm ID hose nozzle
Exhaust Air: Pipe end AD 75 mm
Operating Modes:
- Salt spray
- Condensed water (CWC)
- Chamber air ventilation
- Warm air
- Controlled humidity
Listing

7,009 km
Salt spray chamber / climate cycling device
WeissSC/KWT 450
Call
Condition: excellent (used), Weiss
Type: SC/KWT 450
Salt Spray Chamber
Technical Data:
Test chamber volume: 450 liters
Maximum load: 100 kg
Brine reservoir: 180 liters
External dimensions: Height 920 mm, Width 1930 mm, Depth 800 mm
Test chamber dimensions: Height 740 mm, Width 850 mm, Depth 570 mm
Applications:
Corrosion tests:
Salt spray test: Ambient temperature up to +50°C
Condensation water test: Ambient temperature up to +45°C
Humidifier +75°C
Temperature stability
The temporal temperature deviation is ± K.
Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated power: 2.0 kW Rated current: 8.5 A
Combination:
Salt spray test SS: DIN 50021
Condensation water test KFW: DIN 50017
Hnsdpew Hz Trjfx Aabou
Standard climate (ventilation): DIN 50014
Weight: 180 kg
Condition: used
Scope of delivery: (See picture)
(Subject to technical modifications and errors! All provided data are subject to change!)
For further questions, please feel free to contact us by phone.
Listing

7,009 km
Climate test chamber -10°C to +90°C
VötschVC 0018
Call
Condition: used, Vötsch
Model: VC 0018
Climate Test Chamber, Air-Cooled
Test Chamber Dimensions: Width 580 x Depth 450 x Height 750 mm
External Dimensions: Width 865 x Depth 1150 x Height 1780 mm
Test Chamber Volume: approx. 190 liters
Specifications for Temperature Testing:
Temperature Range: -10°C to +90°C
Temperature Deviation at steady state, according to IEC 60068-3-5,
depending on chamber temperature
over time: ±0.1 to ±0.5 K
spatial: ±0.5 to ±2.0 K
Temperature Change Rate according to IEC 60068-3-5
Heating: 0.6 K/min
Cooling: 0.3 K/min
Heat compensation in the range +20°C to +50°C: 200 W
Calibration Points: +4°C and +90°C
Specifications for Climate Testing:
Temperature Range: +10°C to +90°C
Temperature Deviation at steady state, according to IEC 60068-3-5,
depending on chamber temperature
over time: ±0.1 to ±0.3 K
spatial: ±0.5 to ±1.0 K
Humidity Range: 10% to 98% RH
Electrical Connection:
Rated Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated Power: 1.7 kW
Rated Current: 9.5 A (neutral conductor plug loaded), Schuko approx. connection cable: 3.5 m
Protection: 16 A slow-blow, provided by the customer
Weight: approx. 380 kg net
Refrigerant: R 134A
For your safety as a buyer, please note the following information!
The following points are carried out on all climate chambers we offer prior to delivery:
1. Functional check and replacement of necessary components
2. If necessary, a refill with legally compliant refrigerant
Hsdpfxow Hz S Ue Aabenu
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Specifications and technical data are subject to change and errors are excepted!)
We are happy to answer any further questions you may have by phone.
We make it easier for you to find: "chamber furnace"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Chamber Furnace (2,768)
Search Machineseeker now with more than 2,00,000 used machines:Browse through the most popular machine descriptions:
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month