Bioer Quant Gene 9600 Fluorescent Quantitative Detection SystemBioer Quant Gene 9600 Fluorescent Quantitative ...
Gene 9600
Bioer Quant Gene 9600 Fluorescent Quantitative Detection System
Bioer Quant Gene 9600 Fluorescent Quantitative ...
Gene 9600
Condition
Used
Location
Duxford 

Show images
Show map
Machine data
Price & Location
- Location:
- Duxford, UK
Call
Machine sale

Found a new machine? Now turn the old one into cash.
Achieve the best price through Machineseeker.
More about selling machinery
More about selling machinery
Details about the offer
- Listing ID:
- A20124805
- Reference number:
- PR-001.SR4C
- Update:
- 02.10.2025
Description
This listing is for the Bioer Quant Gene 9600 Fluorescent Quantitative Detection System
The unit is in full working condition and is ready for immediate use
Bioer LineGene Plus 9600 FQD-96A – Fluorescent Quantitative Detection System
Key Specifications
Sample Capacity: 96-well 0.2 mL PCR plates, 12 × 8-strip tubes, or 96 × 0.2 mL single tubes (transparent bottom)
Reaction Volume: 5–100 µL
Dynamic Range: 1–10¹⁰ copies/µL
Detection Channels: 5 or 6 channels (F1–F6)
Excitation Wavelength: 300–800 nm
Emission Wavelength: 500–800 nm
Temperature Range: 4–105°C (0.1°C increments)
Temperature Control Accuracy: ±0.1°C
Temperature Uniformity: ≤ ±0.3°C
Heating Rate: Up to 4.0°C/s
Cooling Rate: Up to 4.0°C/s
Hot Lid Temperature Range: 30–110°C (adjustable, default 105°C)
Fjdpfx Asxhgfgeabepn
Gradient Temperature Range: 1–36°C
Scanning Mode: Full-plate scanning and designated line scanning (5.5 seconds per scan)
Programming: Up to 20 segments per program, up to 99 cycles
Operating System Compatibility: Windows 7/8/10
Software Requirements: Microsoft Excel 2000/2002/2003/2007/2012
Minimum Computer Configuration: RAM: 512 MB; Hard Disk: 10 GB; CPU: Pentium 4; Virtual Memory: ≥1000 MB
Power Supply: 100–240V, 50/60Hz, 600W
Dimensions: 410 mm (W) × 386 mm (D) × 352 mm (H)
Weight: Approximately 20 kg
Certifications: CE, EMC, RoHS2.0, MET
.
The unit is in full working condition and is ready for immediate use
Bioer LineGene Plus 9600 FQD-96A – Fluorescent Quantitative Detection System
Key Specifications
Sample Capacity: 96-well 0.2 mL PCR plates, 12 × 8-strip tubes, or 96 × 0.2 mL single tubes (transparent bottom)
Reaction Volume: 5–100 µL
Dynamic Range: 1–10¹⁰ copies/µL
Detection Channels: 5 or 6 channels (F1–F6)
Excitation Wavelength: 300–800 nm
Emission Wavelength: 500–800 nm
Temperature Range: 4–105°C (0.1°C increments)
Temperature Control Accuracy: ±0.1°C
Temperature Uniformity: ≤ ±0.3°C
Heating Rate: Up to 4.0°C/s
Cooling Rate: Up to 4.0°C/s
Hot Lid Temperature Range: 30–110°C (adjustable, default 105°C)
Fjdpfx Asxhgfgeabepn
Gradient Temperature Range: 1–36°C
Scanning Mode: Full-plate scanning and designated line scanning (5.5 seconds per scan)
Programming: Up to 20 segments per program, up to 99 cycles
Operating System Compatibility: Windows 7/8/10
Software Requirements: Microsoft Excel 2000/2002/2003/2007/2012
Minimum Computer Configuration: RAM: 512 MB; Hard Disk: 10 GB; CPU: Pentium 4; Virtual Memory: ≥1000 MB
Power Supply: 100–240V, 50/60Hz, 600W
Dimensions: 410 mm (W) × 386 mm (D) × 352 mm (H)
Weight: Approximately 20 kg
Certifications: CE, EMC, RoHS2.0, MET
.
Seller
Note: Register for free or log in, to access all information.
Send inquiry
Telephone & Fax
+44 20 38... show
Your listing has been deleted successfully
An error has occurred