Transformer 630 kVA 20/0.4 kV Dyn5Elmowa
DO 630/20
Transformer 630 kVA 20/0.4 kV Dyn5
Elmowa
DO 630/20
Year of construction
1988
Condition
Used
Location
Speyer 

Show images
Show map
Machine data
- Machine type:
- Transformer 630 kVA 20/0.4 kV Dyn5
- Manufacturer:
- Elmowa
- Model:
- DO 630/20
- Machine number:
- 20999
- Year of construction:
- 1988
- Condition:
- used
- Functionality:
- fully functional
Price & Location
- Location:
- Franz-Kirrmeier-Straße 22, 67346 Speyer, Deutschland

Call
Technical details
- Type of input current:
- three-phase
- Overall weight:
- 2,050 kg
- Input voltage:
- 20,000 V
- Input frequency:
- 50 Hz
- Nominal power (apparent):
- 630 kVA
- Secondary voltage:
- 400 V
- Temperature:
- 18 °C
- Input current:
- 18 A
- Type of output current:
- three-phase
- Output voltage:
- 400 V
- Equipment:
- documentation/manual, type plate available
Details about the offer
- Listing ID:
- A21544328
- Update:
- 19.03.2026
Description
For sale is a used oil transformer manufactured by ELMOWA.
Technical Data:
Power: 630 kVA
Voltage: 20 kV / 0.4 kV (400/231 V)
Vector group: Dyn5
Ihodpoyvtpkjfx Abcsw
Year of manufacture: 1988
Cooling: ONAN
Total weight: approx. 2,050 kg
Oil volume: approx. 440 kg
Condition:
The transformer was in operation until it was removed and is fully functional.
An insulating oil test dated 12/2023 is available – the oil meets the requirements according to DIN EN 60422.
PCB content is below the relevant threshold values.
The transformer is ideal as a replacement unit, for industrial applications, or for export.
Inspection possible by appointment.
Pickup only. Loading on site possible / by arrangement.
Sale as used equipment, with exclusion of liability for material defects.
The listing was translated automatically. Translation errors are possible.
Technical Data:
Power: 630 kVA
Voltage: 20 kV / 0.4 kV (400/231 V)
Vector group: Dyn5
Ihodpoyvtpkjfx Abcsw
Year of manufacture: 1988
Cooling: ONAN
Total weight: approx. 2,050 kg
Oil volume: approx. 440 kg
Condition:
The transformer was in operation until it was removed and is fully functional.
An insulating oil test dated 12/2023 is available – the oil meets the requirements according to DIN EN 60422.
PCB content is below the relevant threshold values.
The transformer is ideal as a replacement unit, for industrial applications, or for export.
Inspection possible by appointment.
Pickup only. Loading on site possible / by arrangement.
Sale as used equipment, with exclusion of liability for material defects.
The listing was translated automatically. Translation errors are possible.
Documents
Seller
Note: Register for free or log in, to access all information.
Last online: Today
Registered since: 2026
1 listing online
Send inquiry
Telephone & Fax
+49 173 3... show
Your listing has been deleted successfully
An error has occurred