Used Climats Excal 1413-Ha -40 Bis 180°C for sale (75,763)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
7,009 km
Climate cabinet 138 liters
CLIMATSEXCAL 1413-HA -40 bis 180°C
Call
Condition: excellent (used), Climats
Type: EXCAL 1413-HA
Hedpfx Akov Dt T Tjrjl
Air-cooled climate control cabinet
EXCAL is equipped with a 15-inch capacitive multi-touch panel PC, SSD
memory, Windows 7 and 2 USB ports.
This means it is state-of-the-art.
Technical data:
Test room dimensions: width 550 mm x depth 500 mm x height 500 mm
Housing dimensions: width 820 mm x depth 1375 mm x height 1730 mm
Window 350 x 380
Volume: 138 liters
Flow-through installed in basic equipment
R1: 80 mm ∅
L1: 80 mm ∅
Data for temperature tests:
Temperature range: -40°C to +180°C
Temperature deviation over time ± 0.1 to ± 0.3 K
Temperature homogeneity in space ± 0.5 to ± 1.8 K
Temperature change rate
Heating 15 K/min
Cooling 10 K/min
Data for climate tests:
Temperature range + 10 to +90 °C
Humidity range 10 to 98 %r.h.
Data for operation:
3/N/Ph+T 400V±10% 50 Hz
Rated power 9.8 KVA
Refrigerant R-404A / R-23
Weight: 430 kg
For your safety as a buyer, the following information!
The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Climatic chamber temperature and humidity
EspecPL-3KPH -40°C bis 180°C
Call
Condition: excellent (used), ESPEC Climate Test Chamber PL-3KPH
Device Data
Manufacturer: ESPEC
Model: PL-3KPH
Design: Climate Test Chamber
Cooling: Air-cooled
Description
Used climate test chamber from ESPEC.
Suitable for temperature and humidity testing.
For use in research, development, and quality assurance.
Hedsy H H Iuopfx Akrol
Operating Condition
Display: STOP / ready for operation.
Technical Data
Temperature range: -40°C to +180°C
Humidity range: 20% to 98% RH
Test chamber volume: approx. 400 liters
Dimensions
Internal (W x H x D): 600 x 850 x 800 mm
External (W x H x D): 1010 x 1690 x 1195 mm
Electrical Data
400 V / 3~ / 50 Hz
Refrigeration System
Refrigerant: R404A / R23
Two-stage cooling system
Air-cooled (no external water connection required)
Weight
Approx. 350 kg
Equipment
Touchscreen control panel
Programmable and constant mode operation
BTHC temperature and humidity control
Observation window
Stainless steel test chamber
Internal lighting
Cable port
Overheating protection
Hour counter
Industrial design
Scope of Delivery
ESPEC Climate Test Chamber PL-3KPH
Scope of delivery as shown
Service before delivery (optional)
Function test
Refrigerant service
Leak test
Test run with protocol
Condition
Used.
Condition as shown in photos.
Note
Used device, sale without warranty.
Inspection possible by arrangement.
Loading and transport can be organized upon request.
Subject to prior sale and changes.
If you have any questions, feel free to contact us.
Listing
Borken
7,009 km
Alternating climate chamber
BinderMK 115 E3.1 -40°C bis 180°C
Call
Condition: excellent (used), Binder Temperature Cycling Chamber MK 115 E3.1
Device Data
Hjdpfxjy H Hvls Akrel
Manufacturer: Binder
Model: MK 115 E3.1
Article number: 9020-0175
Design: Temperature Cycling Chamber
Refrigerant: R404A (1.20 kg)
Description
Used temperature cycling chamber from Binder.
Suitable for dynamic temperature tests and rapid temperature changes.
Ideal for use in material testing, research, and quality assurance.
Technology
APT.line™ preheating chamber technology
Natural simulation of temperature gradients
High precision and reproducibility
Features
MCS controller with program memory
Adjustable ramp functions
Class 2 temperature limiter (DIN 12880)
Heated viewing window with interior lighting
Ethernet interface
50 mm pass-through (left)
Stainless steel interior with shelf
4 castors (2 lockable)
Technical Data
Temperature range: -40 °C to +180 °C
Fast temperature cycling (climate change operation)
Chamber volume: 115 liters
Dimensions
External (W x H x D): approx. 980 x 1725 x 865 mm
Internal (W x H x D): approx. 600 x 480 x 400 mm
Electrical Data
400 V / 50 Hz
Power: 3.5 kW
Current: 11.0 A
Pressure Data
Max. operating pressure: 29 bar
Weight
Approx. 260 kg
Condition
Used. For visual and technical condition, refer to the pictures.
Scope of Delivery
Binder MK 115 temperature cycling chamber
Shelf / chamber fittings
Note
Used equipment, sold without warranty.
Inspection by appointment possible.
Loading and transport can be organized upon request.
Subject to prior sale and technical changes.
If you have any questions, please do not hesitate to contact us.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Borken
7,009 km
Climate test chamber with humidity, 335 liters
WeissWK3-340/40 -42°C bis +180°C
Call
Condition: excellent (used), Weiss
Model: WK3-340/40
Weiss Climate Test Chamber, Air-Cooled
Temperature Testing
Volume: 335 liters
Test Chamber Dimensions:
Internal Dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External Dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Minimum Temperature: –42°C
Maximum Temperature: +180°C
Temperature Change Rate, Cooling: 4 K/min
Temperature Change Rate, Heating: 3.2 K/min
Temperature Deviation Over Time: ± 0.1 to ± 0.5 K
Temperature Uniformity Spatially: ± 0.5 to ±1.5 K
Climate Testing:
Temperature Range: +10°C to +95°C
Dew Point Range: -3°C to +94°C
Humidity Range: 10 to 98% RH
Temperature Deviation Over Time: ± 0.1 to ± 0.3 K
Temperature Uniformity Spatially: ± 0.5 to ± 1 K
Humidity Deviation Over Time: ± 1 to ± 3 % RH
Halogen Lamp: 2 x 24V, 50W
Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated Power: 4.1 kW, Rated Current: 14 A
Refrigerant: R-404A
Weight: approx. 515 kg
For your security as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
Hodoygv U Nopfx Akrol
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications reserved!)
Further questions can be answered by phone.
Listing
Borken
7,009 km
Temperature test chamber 990 liters
VötschVT³ 4100 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VT³ 4100
Water-Cooled Temperature Test Chamber
S!MCON/32.NET (with Touch Panel)
Control System Features:
- Color touchscreen with intuitive menu navigation (typically 5.7" or larger)
- Programming of temperature/humidity profiles with ramps and dwell times
- Data acquisition & logging (e.g., temperature profile, alarms)
- USB port for data export (CSV, optionally S!MPATI compatible)
- Network interface (Ethernet) for remote monitoring and control
- User management with password protection
- Interfaces: Volt-free contacts, optionally Modbus or Profibus
VT³ 4100 – Technical Specifications (Temperature Test Chamber)
- Test volume: 990 liters
- Temperature range: -40 °C to +180 °C
- Temporal temperature deviation: ±0.1 to ±0.5 K
- Spatial temperature deviation: ±0.5 to ±1.5 K
- Temperature gradient: 1 to 3 K
- Temperature change rate (per IEC 60068-3-5):
• Heating: 4.0 K/min
• Cooling: 3.0 K/min
- Maximum heat compensation capacity: 4500 W
- Calibration values: +23 °C and +80 °C
- Internal dimensions (W×D×H): 1100 × 950 × 950 mm
- External dimensions (W×D×H): 1390 × 1955 × 1995 mm
Feed-Throughs:
The chamber is equipped with feed-throughs on both the right and left sides, allowing insertion of measuring cables and test devices into the test space.
• 1 × L1 nominal width 50 mm
• 1 × R1 nominal width 125 mm
• 3 × R1 nominal width 50 mm
Electrical connection: 3/N/PE AC, 400V ±10%, 50Hz
Hodpeygvm Ejfx Akrjl
Power consumption: 11.5 kW
Rated current: 22 A
Noise level: approx. 62 dB(A)
Refrigerant: R452A
Weight: 920 kg
Important information for buyers:
For your security, the following measures are carried out on all our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant, if needed
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see picture)
(Subject to change and errors in technical data; information may be subject to alteration!)
For any further questions, feel free to contact us by phone.
Listing
Borken
7,009 km
Temperature test chamber 1540 liters
VötschVT³ 4150 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VT³ 4150
Vötsch Temperature Test Chamber, Air-Cooled
Temperature Testing
Temperature Range: -40°C to +180°C
Rate of Change: Cooling approx. 2.5 K/min
Rate of Change: Heating approx. 3.5 K/min
External Dimensions (W x D x H): approx. 1390 x 2380 x 1995 mm
Test Chamber Dimensions (W x D x H): approx. 1100 x 1475 x 950 mm
Rated Voltage: 3/N/PE AC, 400 V ±10%, 50 Hz
Rated Power: 11.5 kW
Rated Current: 22.0 A
Weight: approx. 1020 kg / 1540 liters
Refrigerant: R 404A
For your safety as a buyer, please note the following information:
We perform the following steps on all chambers offered:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: Used
Scope of delivery: (see photo)
(Technical data subject to change and errors excepted!)
Hjdpfx Akjygux Tsrsl
For further questions, feel free to contact us by phone.
Listing
Borken
7,009 km
Temperature test chamber 600 liters
WeissWT3-600/40 -42°C bis +180°C
Call
Condition: excellent (used), We are offering a Weiss temperature test chamber for sale.
Weiss Temperature Test Chamber with S!MCON / 32-controller, water-cooled
Control Unit: "Touchpanel"
All control and operation commands can be initiated by simply touching the function symbols on the "Touchpanel" control unit.
Adjustable Feet
The test chamber is equipped with adjustable feet to compensate for floor unevenness and to provide adequate ventilation for the machine section.
Cable Ports
Cable ports are installed on both the right and left sides of the test chamber. These allow measurement cables and test devices to be routed into the test space. Ports included as standard:
- R1: NW 125 mm
- L1: NW 50 mm
(The refrigerant has been converted to R-452A)
Test Chamber Volume: approx. 600 liters
External dimensions with hinges and door lock:
Height: 1995 mm, Width: 1090 mm, Depth: 1660 mm
External dimensions without hinges and door lock:
Height: 1995 mm, Width: 1000 mm, Depth: 1660 mm
Internal dimensions:
Height: 950 mm, Width: 800 mm, Depth: 800 mm
Temperature Test Data:
Temperature range: -42 to +180 °C
Temporal temperature deviation at center of usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5):
- Heating: 4.0 K/min
- Cooling: 3.0 K/min
Maximum thermal compensation: 2500 W
Operating Data:
- Test chamber lighting: Halogen bulb 2 x 24V, 50W
- Rated voltage: 3/N/PE AC 400V ±10% 50Hz
- Rated current: 15 A; Rated power: 7.8 kW
- Fuse (on-site): 16 A slow-blow
- Sound pressure level: approx. 58 dB(A) (measured 1 m in front, 1 m height)
- Refrigerant: R-452A
- Weight: 620 kg
Type: WT3-600/40
Important information for your safety as a buyer!
The following steps are carried out on our offered chambers in advance:
1. Function check and replacement of necessary components
2. Refill with legally compliant refrigerant, if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Hedpfx Akeyguh Isrel
Condition: used
Scope of delivery: (see photo)
(Technical data subject to change and errors reserved!)
We are happy to answer any further questions by phone.
Listing
Borken
7,009 km
Climatic chamber temperature and humidity
EspecPL-2KPH -40°C bis 180°C
Call
Condition: excellent (used), Espec
Model: PL-2KPH
ESPEC PL-2 KPH Climate Chambers, Air-Cooled
Temperature range: -40°C to +180°C
Humidity range: approx. 10 to 98% RH
Dependence on temperature range and humidity fluctuations:
± 2.5% RH over time, ± 3.0% RH
Internal dimensions (WxHxD): 500 × 750 × 600 mm
External dimensions (WxHxD): 910 × 1590 × 973 mm
Microprocessor control with 10 pre-set international test standards and 20 freely programmable memory slots,
as well as built-in timer with programmable start/stop automation and error code display.
Programming via touch screen.
Alarm display (audible and visual).
Device protection against overtemperature:
Overtemperature protection with two switching contacts
Illumination of testing chamber
Operating hours counter
Test chamber volume: 225 liters
Net weight: 300 kg
Electrical connection: 400 V 3/N 50 Hz,
Plug: CEE 16 A, max. current: 11.0 A
Refrigerant: R404A
Scope of delivery: Espec climate test chamber
Buyer information for your security:
The following procedures are carried out in advance on the chambers we offer:
1. Functional inspection and replacement of necessary components
2. Refilling with legally compliant refrigerant if necessary
3. Leak test with certificate
Hsdox Iu I Sepfx Akrol
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photos)
(Specifications and technical details subject to change and errors!)
If you have further questions, please feel free to contact us by phone.
Listing
Borken
7,009 km
Temperature chamber 2000 liters
CTST-40/2000 -40°C bis +180°C
Call
Condition: excellent (used), CTS
Type: T-40/2000
Air-cooled temperature test chamber
Technical design:
Refrigeration unit:
air-cooled, low-noise, fully hermetic, infinitely variable power adjustment
through electronic monitoring and control system,
environmentally friendly refrigerant R404A
Door:
fully opening door, door hinge left,
one-handed operation, lockable.
Shelf:
Stainless steel, support surface 970 x 980 + 500 mm
Max. load per shelf 35 kg
Total load with max. grid load 100 kg
Test area lighting: 3x halogen lamp 20 W, 12 V
Control:
32 bit controller
LCD control panel
Digital display of set and actual values
Hodpfx Asup T Uqokrsl
Numerical input of setpoint values
Error messages in plain text
RS 232 interface
Free switching channels for on-site test material control
Temperature range: -40°C to +180°C
Nominal voltage: 400V 3/N 50Hz
Rated power: 10.4 kW
Nominal current: 17.2 A
Compressor: TFH2516Z
Pipe feed-through NW 50
Control panel
Window 570x710 mm
Electrical connection, cable length 5m
Technical performance data:
Temperature tests:
Temperature range -40°C to +180°C
Temperature deviation ≤ ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 1.5 K/min
Heat radiation:
approx. 2500 W at +20°C
approx. 2100 W at ± 0°C
approx. 1500 W at -20°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume: 2000 liters
Test chamber dimensions: Height 900, width 975, depth 2200 mm
External dimensions: Height 1950, width 1290, depth 3145 mm
Operating data:
Electrical connection: 400 V +6/-10 %, 3/N, 50 Hz
Rated power: 17.2 kW
Protection class: IP 22
Condensate drain unpressurized R 1/2" internal thread
Sound pressure level (according to DIN EN ISO 3744
measured at a distance of 1 m from the front) < 55 dB(A)
Weight: approx. 1200 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Temperature cabinet 990 liters
WeissWT3-1000/40 -40°C bis +180°C
Call
Condition: excellent (used), White
Type: WT3-1000/40
Weiss Temperature test chamber With S!MCON / 32 control unit Water-cooled
Touch panel" control unit
All control and operating commands can be triggered by simply touching the function icons on the
all control and operating commands by simply touching the function icons.
Levelling feet
To compensate for uneven floors and to ensure adequate ventilation of the machine part,
the test chamber is equipped with adjustable feet.
Feed-throughs
The test chamber is equipped with feed-throughs on the right and left side.
Measuring cables and test equipment can be routed through these into the test chamber.
Feed-through built into basic equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber capacity: approx. 990 liters
Test chamber dimensions: Height 950 mm, width 1100 mm, depth 950 mm
External dimensions: Height 2000 mm, width 1415 mm, depth 2105 mm
Data for temperature tests:
Temperature range: -40 to +180 °C
Hedpfx Akethhw Asrjl
Temperature deviation in time in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate
Heating: 4.0 K/min
Cooling: 3.0 K/min
Heat compensation max. 4500 W
Data for operation:
Test room lighting Halogen bulb 2x 24V, 50W
Nominal voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Rated current: 22.0 A Rated power 11.5 kW
On-site fuse 32 A slow-blow
Sound pressure level approx.
measured at a distance of 1 m from the front. 1m height 56 dB(A)
Refrigerant: R-404A
Weight: 840 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Temperature test chamber 600 liters
WeissWT3-600/40 -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss temperature chamber.
Weiss temperature test chamber With S!MCON / 32 control Air-cooled
(refrigerant converted to R-452A)
Touch panel" control unit
All control and operating commands can be triggered on the "touch panel" control unit by simply touching the function icons.
all control and operating commands by simply touching the function icons.
Levelling feet
To compensate for uneven floors and to ensure adequate ventilation of the machine part,
the test chamber is equipped with adjustable feet.
Feed-throughs
The test chamber is equipped with feed-throughs on the right and left side.
Hsdpfx Akjrak S Dorjl
Measuring cables and test equipment can be routed through these into the test chamber.
Feed-through built into basic equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber capacity: approx. 600 liters
External dimensions with hinges and door lock
Height 1995 mm, width 1090 mm, depth 1660 mm
External dimensions without hinges and door lock
Height 1995 mm, width 1000 mm, depth 1660 mm
Internal dimensions: Height 950 mm, width 800 mm, depth 800 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5)
Heating: 4.0 K/min
Cooling: 3.0 K/min
Heat compensation max. 2500 W
Data for operation:
Test room lighting Halogen bulb 2 x 24V, 50W
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 15 A Rated power 7.8 kW
On-site fuse 16 A slow-blow
Sound pressure level approx.
measured at a distance of 1m from the front. 1m height 61 dB(A)
Refrigerant: R-452A
Weight: 620 kg
Type: WT3-600/40
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Climatic test chamber shaker chamber 2160 liters
WeissWK3-2200/40/5/V -40°C bis +180°C
Call
Condition: excellent (used), Weiss
Type: WK3-2200/40/5/V
Weiss Climate Test Chamber, Water-Cooled
Specifications for Temperature Testing:
Temperature range: -40°C to +180°C
Temperature change rates:
Heating: 6.0 K/min
Cooling: 11.5 K/min
Temperature deviation:
Temporal ± 0.8 K
Spatial ± 2.0 K
Heat compensation max. 8000 W
Specifications for Climatic Testing:
Temperature range: +10°C to +95°C
Dew point temperature range: +4°C to +94°C with closed floor element
Humidity range: 10 to 95% rH
Temperature deviation (temporal): ± 0.3 K
Humidity deviation (temporal): ± 3% rH
Temperature uniformity:
Spatial ± 1.0 K
Heat compensation max.: 500 W
Test chamber volume: 2,160 liters
Test chamber dimensions: Height 1,115 mm, Width 1,400 mm, Depth 1,400 mm
External dimensions (lowered): Height 2,318 mm, Width 1,860 mm, Depth 3,658 mm
External dimensions above shaker: Height 2,710 mm
External dimensions max. stroke height: 3,038 mm
Exchangeable floor dimensions: Width 1,600 mm, Depth 1,504 mm
Operating Data:
Rated voltage: 3/N/PE AC 400V +10% 50Hz
Rated power: 38.0 kW
Rated current: 63.0 A
Customer-side fuse: 80 A slow-blow
Refrigerant: R 404A
Weight: approx. 2,100 kg
Important information for your safety as a buyer:
The following points will be carried out on the chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. If required, refilling with refrigerant compliant with legal regulations
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Hsdpfx Aow I Rxrekrel
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and errors excepted!)
We are happy to answer any further questions you may have by phone.
Listing
Borken
7,009 km
Small climate chamber 60 liters with humidity
CTSC-40/60 -40 bis +180°C
Call
Condition: excellent (used), CTS
Type: C-40/60
CTS small climate chamber air-cooled
Test volume: 60 liters
Temperature range: -40 °C / +180 °C
Humidity range
10% to 98% relative humidity
+10 °C to +90 °C in the temperature range
+5 °C to +89.5 °C in the dew point range
Dimensions (WxDxH):
Inside: 400 mm x 345 mm x 425 mm
Housing: 560 mm x 845 mm x 1575 mm
Refrigerant: R-404A
Nominal voltage: 230V 1/N 50 Hz
Output: 3.3 kW
Rated current: 13 A
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Hsdeu Hlb Ejpfx Akrol
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Climate test chamber 1540 liters
WeissWK1-1500/40 Temp. -40°C bis +180°C
Call
Condition: used, Weiss
Type: WK1/1500/40
Weiss Climate Test Chamber, Air-Cooled with Humidity Control
Hedpfxsw Hcttj Akrol
(converted to use refrigerant R-452a)
Temperature range: -40°C to +180°C
Cooling rate approx. 2.5 K/min, heating rate approx. 3.5 K/min
Temporal temperature deviation at center of test space: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature range: +10°C to +95°C
Humidity range: 10% to 98% r.H.
Temporal temperature deviation at center of test space: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Heat compensation
In the range of +25°C to +95°C, at a relative humidity up to 90%: 500 W
Test chamber dimensions: Height: 950 mm, Width: 1100 mm, Depth: 1475 mm
External dimensions: Height: 2005 mm, Width: 1300 mm, Depth: 2450 mm
Test volume: approx. 1540 liters
Test chamber lighting: Halogen bulb 12V, 50W
Rated voltage: 3/NPEAC 400V ±10% 50Hz
Rated power: 11.5 kW, Rated current: 22.0 A
Fuse on site: 32A slow-blow
Protection class (control cabinet and operator panel): IP 54
Refrigerant: R-452a
Weight: 920 kg
For your safety as a buyer, please note the following information:
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a test run, monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Technical specifications subject to change and errors excepted!)
If you have further questions, we will be happy to answer them by phone.
Listing
Borken
7,009 km
Climate test chamber with humidity 335 liters
WeissWK3-340/40 -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss climate test chamber.
Weiss climate test chamber water-cooled
(refrigerant converted to R-452A)
Temperature test
Hedpfeq U Sdcjx Akrol
Volume 335 liters
Test chamber dimensions:
Test chamber dimensions: Height 750 mm, width 580 mm, depth 765 mm
External dimensions: Height 1775 mm, width 870 mm, depth 1600 mm
Minimum temperature -42°C
Maximum temperature +180°C
Temperature change rate, cooling 4 K/min
Temperature change rate, heating 3.2 K/min
Temperature deviation, temporal ± 0.1 to ± 0.5 K
Temperature homogeneity, spatial ± 0.5 to ±1.5 K
Climate test:
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range 10 to 98% r.h.
Temperature deviation, temporal ± 0.1 to ± 0.3 K
Temperature homogeneity, spatial ± 0.5 to ±1 K
Humidity deviation, temporal ± 1 to ± 3 % r.h.
Voltage: 3/N/PE AC 400V±10% 50Hz
Rated power 4.1 kW Rated current: 14 A
Refrigerant: R-452A
Type: WK3-340/40
Weight Approx. 515 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Climatic test chamber with humidity, 600 liters
CTSC-40/600 -40 bis +180°C
Call
Condition: excellent (used), CTS Climate Test Chamber Type: C -40/600, Air-Cooled
(converted to R-452a refrigerant)
Test chamber volume: 600 liters
Temperature tests:
Hedpfsw U Awmjx Akrsl
- Temperature range: -40°C to +180°C
- Temperature deviation: ±0.1 K / ±0.3 K over time (at stabilized condition)
- Average temperature rate of change (without test load and radiant heat):
- Heating: 2.5 K/min
- Cooling: 3.0 K/min
- Maximum radiant heat input: 2500 W at +20°C
Climatic tests:
- Climate range / Technical data:
- Temperature range: +10°C to +95°C
- Humidity range: 10% r.h. to 98% r.h.
- Dew point range I: +7°C to +94°C
- Dew point range II: –10°C to +7°C
- Consistency values (over time):
- Humidity consistency I: ±0.5% r.h. to ±1.5% r.h.
- Humidity consistency II: ±1% r.h. to ±3% r.h.
- Temperature consistency: ±0.1 K to ±0.3 K
Chamber internal dimensions (approx.): Height: 850 mm, Width: 850 mm, Depth: 830 mm
External dimensions (approx.): Height: 1900 mm, Width: 1115 mm, Depth: 1850 mm
Refrigerant: R-452A
Power connection: 400V 3/N 50Hz
Connected load: 8.2 kW, Rated current: 11.9 A
Weight: 550 kg
Important information for your purchase!
The following checks and procedures are performed on all our offered chambers prior to delivery:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see image)
(Subject to changes and errors in the technical data and specifications!)
If you have further questions, we will be happy to answer them by phone.
Listing
Borken
7,009 km
Climatic test chamber -40 to +180°C
WeissWK-480/40/10 480 Liter m. Feuchte
Call
Condition: excellent (used), Here we offer a Weiss climatic test chamber.
Water-cooled
Test chamber lighting Halogen bulb 24V, 50W
Hodpjq Dpzysfx Akrsl
Data for temperature tests:
Temperature range: -40°C to +180°C
Temporal temperature deviation in the center of the chamber: ± 0.3 to ± 0.8 K
Spatial temperature deviation: ± 0.5 to ± 2 K
Temperature change rate
Heating: 10 K/min
Cooling: 12.5 K/min
Heat compensation at +20°C 8000 W
Heat compensation at -20°C 3000 W
Data for climate tests
Temperature range: +10°C to +95°C
Humidity range: 10 to 98 % r.h.
Temperature deviation in time in the center of the usable space: ± 0.2 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Humidity fluctuation over time in the center of the usable space: ± 1 to ± 3 % RH
Test chamber dimensions: Height 950 mm, width 760 mm, depth 650 mm,
External dimensions: Height 2025 mm, width 1090 mm, depth 2480 mm,
Nominal voltage: 3/N/PE AC 400 V ± 10% 50 Hz
Rated current: 24 A Rated power: 16.0 KW
Refrigerant: R452A
Weight: approx. 900 kg
Type: WK-480/40/10
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Temperature cabinet 335 liters
WeissWT3-340/40 -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss temperature chamber.
Weiss temperature test chamber With S!MCON / 32 control Water-cooled
(refrigerant converted to R-452A)
Touch panel" control unit
All control and operating commands can be triggered on the "touch panel" control unit by simply touching the function icons.
all control and operating commands by simply touching the function icons.
Levelling feet
To compensate for uneven floors and to ensure adequate ventilation of the machine part,
the test chamber is equipped with adjustable feet.
Feed-throughs
The test chamber is equipped with feed-throughs on the right and left side.
Measuring cables and test equipment can be routed through these into the test chamber.
Feed-through built into basic equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber capacity: approx. 335 liters
Test chamber dimensions: Height 750 mm, width 580 mm, depth 765 mm
External dimensions: Height 1775 mm, width 870 mm, depth 1600 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate
Heating: 3.2 K/min
Cooling: 4.0 K/min
Heat compensation max. 2300 W
Data for operation:
Test room lighting Halogen bulb 2x 24V, 50W
Rated voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Hsdpfxerbigfe Akrsl
Rated current: 14 A Rated power 4.1 kW
On-site fuse 16 A slow-blow
Sound pressure level approx.
measured at a distance of 1 m from the front. 1m height 56 dB(A)
Refrigerant: R-452A
Weight: 515 kg
Type: WT3-340/40
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Climate test chamber with humidity
Weiss -72°C bis +180°CWK3-340/70
Call
Condition: excellent (used), Weiss
Type: WK3-340/70
Weiss Air-Cooled Climatic Test Chamber
Touch Panel Control Unit
All control and operating commands can be triggered by simply touching the function symbols on the touch panel control unit.
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Plug-ins
The test chamber is equipped with plug-ins on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Penetration included in standard equipment
R1: NW 125 mm
L1: NW 85 mm
Volume 335 liters
Test chamber dimensions:
Test chamber dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Data for temperature tests:
Minimum temperature -72°C
Maximum temperature +180°C
Temperature deviation, temporal ± 0.1 to ± 0.5 K
Temperature homogeneity, spatial ± 0.5 to ± 1.5 K
Temperature change rate, cooling 3 K/min
Temperature change rate, heating 3 K/min
Data for climatic tests:
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range: 10 to 98% RH
Temperature deviation, over time: ± 0.1 to ± 0.3 K
Temperature homogeneity, spatial: ± 0.5 to ± 1 K
Humidity deviation, over time: ± 1 to ± 3% RH
Hjdpfx Asv Sr Hzskrol
Operating data:
Test room lighting: 2 x 24V, 50W halogen bulb
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 16 A
Nominal power: 4.9 kW
Fuse: 16 A slow-blow (on-site)
Refrigerant: R-452A/R23
Weight: Approx. 585 kg
For your safety, the following information is provided as a buyer!
The following steps are performed on our chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Wiefelstede
6,930 km
Pipe quick release
unbekanntSpannbereich 40 bis 180 mm
Call
Condition: good (used), Clamping device, clamp bracket, clamp clamp, clamping bracket, pipe clamp bracket, pipe clamp, pipe clamping system, mounting device for pipes, pipe quick clamp, pipe quick clamp
Hsdpfx Akow Upx Rsrel
-Pipe clamp: pipe quick release
-Clamping range: Ø 40 to 180 mm, see photos
-Dimensions: 230/120/H310 mm
-Weight: 3.5 kg
Listing
Borken
7,009 km
Temperature cabinet 335 liters
WeissWT3-340/70 -72°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss temperature cabinet.
Weiss temperature cabinet With S!MCON / 32 control Air-cooled
(refrigerant converted to R-452A)
Test chamber capacity: approx. 335 liters
Test chamber dimensions: Height 750 mm, width 580 mm, depth 765 mm
External dimensions: Height 1775 mm, width 870 mm, depth 1600 mm
Data for operation:
Test room lighting Halogen bulb 24V, 50W
Nominal voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Rated current: 12.5 A Rated power 4.1 kW
On-site fuse 16 A slow-blow
Hsdpfx Akoq U Sdnersl
Sound pressure level approx.
measured at a distance of 1 m from the front. 1m height 58 dB(A)
Data for temperature tests:
Temperature range: -72 to +180 °C
Temperature deviation in time in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature gradient
(according to IEC 60068-3-5): 1 to 4 K
Temperature change rate (according to IEC 60068-3-5)
Heating: 3.0 K/min
Cooling: 3.0 K/min
Heat compensation max. 1500 W
Refrigerant: R-452A / R-23
Weight: 585 kg
Type: WT3-340/70
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
7,009 km
Temperature test chamber 1000 liters
CTS - 70°C bis +180°CTS -70/1000-10 bis ca.10 K/min
Call
Condition: good (used), Type: TS -70/1000-10
For sale is a CTS temperature test chamber
Model: TS -70/1000-10
Cooling: water-cooled refrigeration unit
Compressor has been replaced!
Features:
- Multi-touch control system
- USB and Ethernet interfaces
- Cable feedthroughs for test cables: 4 × Ø 125 mm
- Safety temperature limiter
Applications:
Hsdpfsxdi Ezex Akrel
- Environmental and longevity tests
- Thermal cycling tests (stress screening)
- Quality assurance and research & development
- Electronics, automotive, materials testing
Test chamber volume: 1,000 liters
Test chamber dimensions:
- Height: approx. 1,000 mm
- Width: approx. 860 mm
- Depth: approx. 1,100 mm
External dimensions:
- Height: approx. 1,950 mm
- Width: approx. 1,270 mm
- Depth: approx. 1,900 mm
Temperature range: -70°C to +180°C
Temperature deviation: ± 0.3 K over time
Temperature change rate: up to approx. 10 K/min
Electrical connection: 400V 3/N 50Hz
Rated power: approx. 23.1 kW
Rated current: approx. 40 A
Refrigerant: R404A / R23
Weight: 1,000 kg
For your peace of mind as a buyer, please note:
The following inspections and services are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant if required
3. Leak test with certificate
4. Following successful checks, chambers undergo a documented test run
Condition: used
Scope of delivery: (See pictures)
(Specifications and technical data subject to change and errors excepted!)
We are happy to answer further questions by phone.
Listing
Borken
7,009 km
Climate test chamber 990 liters
Weiss – 40…+ 180°CWK11-1000/40 mit Zander K-MT 2
Call
Condition: excellent (used), Weiss
Hedpox Hxkzsfx Akrel
Model: WK11-1000/40
For sale is a professional Weiss Umwelttechnik WT-WK 1000/40 climate test chamber with fully automatic cold-regenerating adsorption dryer.
The installed fixtures in the test chamber can be removed if required. Currently, due to these fixtures, the control cabinet is limited to a temperature range of −40°C to +60°C. Once the fixtures are removed, the manufacturer can expand the temperature range back to the standard values of −40°C to +180°C, as the fixtures are not suitable for these higher temperatures.
This equipment is ideal for precise temperature and humidity testing on components, assemblies, and devices. It is perfectly suited for applications in industry, development, quality assurance, and research.
Weiss Climate Test Chamber – Water Cooled
Data for Temperature Tests:
- Temperature range: −40°C to +60°C
- Temporal temperature fluctuation (at center of usable space): ± 0.1 to ± 0.5 K
- Spatial temperature deviation: ± 0.5 to ± 2.0 K
- Temperature change rate:
- Heating: 4 K/min
- Cooling: 3 K/min
Data for Climate Tests:
- Temperature range: +10°C to +95°C
- Humidity range: 10 to 98 % r. H.
- Temporal temperature fluctuation (at center): ± 0.1 to ± 0.3 K
- Spatial temperature deviation: ± 0.5 to ± 1 K
- Temporal humidity fluctuation (at center): ± 1 to ± 3 % r. H.
- Thermal compensation:
- In the range of +25°C to +95°C
- At a relative humidity of up to 90%, 500 W
Humidification System Data:
- Reservoir volume: 20 l
- Water quality: demineralized
- pH value: 6 to 7
- Conductivity: 5 to 20 μS/cm³
- Water consumption at constant +40°C, 92% r. H.: 21/24 h
- Temperature gradient:
- (according to IEC 60068-3-5): 1 to 2 K
Test Chamber Dimensions: Height: 950 mm, Width: 1100 mm, Depth: 950 mm
External Dimensions: Height: 1980 mm, Width: 1385 mm, Depth: 1850 mm
Test Chamber Volume: approx. 990 liters
Nominal Voltage: 3/N / PE AC 400 V +10% 50 Hz
Nominal Power: 11.5 kW, Nominal Current: 22.0 A
Refrigerant: R 404A
Weight: 840 kg
Important information for your safety as a buyer!
The following steps are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Technical data subject to modifications and errors!)
Further questions can be answered via telephone.
Listing
Borken
7,009 km
With moisture 1000 liters
CTS KlimaprüfschrankC-70/1000-S -70°C bis +180°C
Call
Condition: excellent (used), CTS Climate Test Chamber C-70/1000-S
Device Data
Manufacturer: CTS GmbH
Model: C-70/1000-S
Year of manufacture: 08/2011
Serial number: 113054
Type: Climate test chamber / Environmental simulation chamber
Cooling: Water-cooled
Description
Used CTS climate test chamber for precise temperature and climate testing.
Suitable for material, component, and reliability testing.
Applications in industry, research, development, and quality assurance.
Temperature and Climate Data
Temperature range: -70 °C to +180 °C
Temperature change rate: approx. 2.5 K/min heating
Temperature change rate: approx. 2.5 K/min cooling
Humidity range: 10% to 98% RH
Dew point range I: +7 °C to +94 °C
Dew point range II: -10 °C to +7 °C
Electrical Data
400 V / 3/N / 50 Hz
Power: 9.7 kW
Current: 17.9 A
Protection class: IP 22
Cooling System
Refrigerants: R404A / R23
Pre-cooling stage: R404A, 2.3 kg
Cooling stage: R23, 0.86 kg / 15 bar
Operating overpressure PS: 25 bar
Test pressure PT: 27.5 bar
Features
CTS control unit with LCD display
Programmable operation
Digital setpoint/actual value display
Viewing window in door
Stainless steel test chamber
Test specimen protection / temperature limiter
Interior lighting
Cable ports on the sides
Feedthroughs approx. 50 mm and approx. 125 mm
RS232 interface as per documentation
Digital outputs for test specimen control
Mobile design on castors
Dimensions
Test chamber volume: approx. 1000 liters
External (W x D x H): approx. 2245 x 1270 x 1950 mm
Installation size (W x D x H): approx. 2350 x 1290 x 2000 mm
Weight
Test chamber: approx. 1000 kg
Recooler: approx. 120 kg
Documentation
Hedpfxjy Iam Hj Akrjl
Declaration of conformity
Test certificates
Operating manual
Error messages and digital channels
Site plan
Quick guide
Humidity diagram
Scope of Delivery
CTS Climate Test Chamber C-70/1000-S
Documentation as available
Scope of delivery as shown
Optional Pre-delivery Service
Function test
Refrigerant service
Leak test
Test run with protocol
Condition
Used.
Condition as per photos.
Note
Used equipment, sold without warranty.
Inspection possible by appointment.
Loading and transport can be organized on request.
Subject to prior sale and technical changes.
If you have any questions, please feel free to contact us.
Listing
Borken
7,009 km
Temperature shock chamber 580 liters
RS-SimulatorenST2K 1000/55 -70°C bis +180°C
Call
Condition: excellent (used), RS-Simulatoren Temperature Shock Chamber ST2K 1000 / 55
Device Data
Manufacturer: RS-Simulatoren
Model: ST2K 1000 / 55
Design: Temperature Shock Chamber
Cooling: Water-cooled
Description
Used temperature shock chamber for standardized thermal shock testing. Suitable for material, component, and reliability testing. Ideal for use in industrial, automotive, research, and quality assurance applications.
System Description
- 2 separate temperature chambers (hot/cold)
- Automatic horizontal test basket transfer
- Fast cycling for temperature shock tests
Temperature Ranges
Hot chamber: +40 °C to +180 °C
Cold chamber: -70 °C to +100 °C
Temporal deviation: ±0.8 K
Test Chamber
Volume: approx. 580 liters
Internal dimensions (W x H x D): approx. 1070 x 680 x 800 mm
Max. load: approx. 150 kg
Power Supply
400 V / 3~ / N / PE / 50 Hz
Power: max. 33 kVA
Max. current: 65 A
Media Connections
Cooling water: G 1", approx. 3 bar (max. 10 bar)
Cooling water demand: max. 3.2 m³/h
Cooling water return: non-pressurized
Compressed air: NW 7.2, 4–10.5 bar
Dimensions
External (W x H x D): approx. 2800 x 2400 x 2200 mm
Weight
Approx. 2800 kg
Features
- Horizontal basket movement
- C-rails in the test chamber
- Large test basket (>1000 mm)
- Observation window
- Interior lighting
- SE-604 control system
- Programmable operation and data logging
- RS232 interface
Cooling System
Refrigerants: R449A / R23
R449A: approx. 8.0 kg
R23: approx. 2.5 kg
Operating Data
Operating hours: approx. 4,500 hrs
Sound level: approx. 67 dB(A)
Ambient Conditions
Temperature: +12 °C to +30 °C
Humidity: 25% to 75% r.h.
Scope of Delivery
- RS-Simulatoren Temperature Shock Chamber ST2K 1000 / 55
- Delivery as illustrated
Optional Pre-Delivery Service
- Functional test
- Refrigerant service
- Leak test
- Test run with report
Condition
Used. Condition as shown in photos.
Note
Hsdpfx Asy H Igfokrol
Used equipment, sold without warranty. Inspection possible by arrangement. Loading and transport can be organized upon request.
Subject to prior sale and modifications.
Should you have any questions, please feel free to contact us.
We make it easier for you to find: "climats excal 1413-ha -40 bis 180°c"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month







































































































































































































































