Climatic test chamber -40 to +180°C
Weiss WK-480/40/10 480 Liter m. Feuchte

Condition
Used
Location
Borken Germany
Climatic test chamber -40 to +180°C Weiss WK-480/40/10 480 Liter m. Feuchte
Climatic test chamber -40 to +180°C Weiss WK-480/40/10 480 Liter m. Feuchte
Climatic test chamber -40 to +180°C Weiss WK-480/40/10 480 Liter m. Feuchte
Climatic test chamber -40 to +180°C Weiss WK-480/40/10 480 Liter m. Feuchte
Climatic test chamber -40 to +180°C Weiss WK-480/40/10 480 Liter m. Feuchte
Climatic test chamber -40 to +180°C Weiss WK-480/40/10 480 Liter m. Feuchte
Climatic test chamber -40 to +180°C Weiss WK-480/40/10 480 Liter m. Feuchte
Climatic test chamber -40 to +180°C Weiss WK-480/40/10 480 Liter m. Feuchte
Climatic test chamber -40 to +180°C Weiss WK-480/40/10 480 Liter m. Feuchte
more Images
Weiss WK-480/40/10 480 Liter m. Feuchte
Weiss WK-480/40/10 480 Liter m. Feuchte
Weiss WK-480/40/10 480 Liter m. Feuchte
Weiss WK-480/40/10 480 Liter m. Feuchte
Weiss WK-480/40/10 480 Liter m. Feuchte
Weiss WK-480/40/10 480 Liter m. Feuchte
Weiss WK-480/40/10 480 Liter m. Feuchte
Weiss WK-480/40/10 480 Liter m. Feuchte
Weiss WK-480/40/10 480 Liter m. Feuchte
Show images
Show map

Machine data

Machine type:
Climatic test chamber -40 to +180°C
Manufacturer:
Weiss
Model:
WK-480/40/10 480 Liter m. Feuchte
Condition:
excellent (used)

Price & Location

Location:
Einsteinstraße 8a, 46325 Borken, DE Germany
Call

Details about the offer

Listing ID:
A14398132
Reference number:
23864
Update:
15.11.2024

Description

Here we offer a Weiss climatic test chamber.
Water-cooled
Test chamber lighting Halogen bulb 24V, 50W
Data for temperature tests:
Temperature range: -40°C to +180°C
Temporal temperature deviation in the center of the chamber: ± 0.3 to ± 0.8 K
Spatial temperature deviation: ± 0.5 to ± 2 K

Temperature change rate
Heating: 10 K/min
Cooling: 12.5 K/min
Heat compensation at +20°C 8000 W
Heat compensation at -20°C 3000 W
Data for climate tests
Temperature range: +10°C to +95°C
Humidity range: 10 to 98 % r.h.
Temperature deviation in time in the center of the usable space: ± 0.2 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Humidity fluctuation over time in the center of the usable space: ± 1 to ± 3 % RH
Test chamber dimensions: Height 950 mm, width 760 mm, depth 650 mm,
External dimensions: Height 2025 mm, width 1090 mm, depth 2480 mm,
Nominal voltage: 3/N/PE AC 400 V ± 10% 50 Hz
Rated current: 24 A Rated power: 16.0 KW
Refrigerant: R452A
Weight: approx. 900 kg
Type: WK-480/40/10
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.

Condition: used

Scope of delivery: (see picture)

(Changes and errors in the technical data, specifications are reserved!)

Fpsdpfx Aasq Dpzyjbon
We will be happy to answer any further questions you may have on the phone.

The listing was translated automatically. Translation errors are possible.

Seller

Last online: A week ago

Registered since: 2012

599 listings online

Trustseal Icon
Call

Send inquiry

Countryus 
Germany
Austria
Switzerland
United States
United Kingdom
France
Belgium
Spain
Mexico
Italy
Netherlands
Poland
Russian Federation
Belarus
Ukraine
Estonia
Turkey
New Zealand
Ireland
Czech Republic
Denmark
Finland
Sweden
Norway
Luxembourg
Greece
Lithuania
Latvia
Iceland
Portugal
Brazil
Venezuela
Argentina
Hungary
Slovakia
Romania
Moldova
Slovenia
Serbia
Montenegro
Albania
Croatia
Bulgaria
Macedonia
Bosnia and Herzegovina
Israel
Egypt
Morocco
India
Indonesia
South Korea
Japan
Thailand
Malaysia
Vietnam
China
Taiwan
Iran
Bangladesh
Afghanistan
Note: Your inquiry will be forwarded to all sellers in this machine category. This allows you to receive a large number of offers.
The inquiry could not be sent. Please try again later.

Telephone & Fax

+49 2861 ... show