Used Rockwell Hardness Test for sale (12,449)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing

7,009 km
Climate test chamber 1000 liters
CTSC-55/1000 Li -50°C bis 100°C
Call
Condition: excellent (used), CTS
Climate test chamber C-55/1000 Li water-cooled
Temperature range: -50°C to +100°C
Humidity range: 5 to 95% RH
Dew point range: 5°C to +78°C
Rated voltage: 400V 3/N 50Hz
Rated power: 9.5 kW
Nominal current: 18 A
Compressor: TFH2511Z / TFH2511Z Refrigerant R404A/R23
The type designation of the CTS cabinet series is composed as follows:
z. e.g. type C -55/1000/Li
1) C means: climate
2) -55 means: lower temperature -55 °C
3) 1000 means: 1000 liter test chamber volume
4) Li means: special equipment for
Hsdpova Hi Hsfx Aabofn
tests with lithium-ion accumulators
Control:
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoints
Error messages in plain text
Ethernet interface
RS 232 interface
Free switching channels for on-site
test material control
Test room lighting:
energy-efficient, high-intensity LED light strip mounted on the door
Insert grid:
Stainless steel, support surface 970 x 980 mm
Load per shelf max. 35 kg
Total load with max. grating load 100 kg
1a Feed-through NW50
1b Feed-through 2x NW125
1c Entry port 2x Rp 314°
for Minimax
Technical performance data:
Temperature tests:
Temperature range -50°C to +100°C
Temperature deviation ≤ ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat compensation
approx. 4000 W at +20°C
approx. 2200 W at -40°C
Climate tests:
Temperature range +5 °C to +95 °C
Humidity range 5% to 95% rel. humidity
Dew point range +5°C to 78°C
Temperature deviation ≤ ±1.0 K in time
Humidity deviation ≤ ±3.0% relative humidity over time
The technical data refers to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without heat compensation and without additional equipment.
Options may influence the performance data.
Dimensions:
Test volume 1000 liters
Test chamber dimensions Height, approx. 1000 mm, width, approx. 860 mm, depth, approx. 1100 mm
External dimensions Height, approx. 1950 mm, width, approx. 1270 mm, depth, approx. 1900 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Nominal current 18 A
Rated power 9.5 kW
Protection class IP 54
Sound pressure level < 58 dB(A)
(according to DIN EN ISO 3744
measured at a distance of 1 m from the front)
Mass approx. 1000 kg
Heat output to the installation room 10.4 kW
Cooling unit:
water-cooled, low-noise, fully hermetic
Infinitely variable output adjustment via electronic monitoring and control system,
environmentally friendly refrigerant R404A/R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,009 km
Climate test chamber with humidity
VötschVC³ 4100 990 Liter -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Vötsch climatic test chamber.
Designation VC³ 4100 Air-cooled
With temperature change rate of 3 K/min
Test chamber dimensions: Height 950 mm x width 1100 mm x depth 950 mm
Unit dimensions: Height 2000 mm x width 1300 mm x depth 1916 mm
Hfodpfoqwim Ejx Aabsn
Volume: 990 liters
Feed-through: Ø 125 mm Ø 50 mm
Data for temperature tests:
Temperature range -42°C to +180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature homogeneity in space ± 0.5 to ± 1.5 K
Temperature change rate:
Heating 4.0 K/min
Cooling 3.0 K/min
Max. heat compensation at +20°C 4500 watts
Data for climate tests
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range 10 to 98% r. h.
Temperature deviation temporal ± 0.1 to ± 0.3 K
Temperature homogeneity in space ± 0.5 to ± 1.0 K
Humidity deviation temporal ± 1 to ± 3% r. h.
Heat compensation max. 500 W
Voltage: 3/N/PE AC 400V ± 10% 50Hz
Rated power: 11.5 kW
Nominal current: 22.0 A
Refrigerant: R-404 A
Weight approx. 840 kg
Type: VC³ 4100
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,009 km
Endurance test bench
EDAG Huf
Call
Condition: excellent (used), EDAG
EDAG Huf endurance test bench
Purpose:
This test bench is intended exclusively for testing parts that are capable of rotational and/or translational movement
as part of an endurance test and within the limits of the following technical data.
Technical data:
Dimensions: width 1565 mm x depth 615 mm x height 1655 mm
Weight approx. 450 kg
Operating voltage 400V /50Hz
Control voltage 5, 24
Provisional fuse 16 A
Test device:
Maximum stroke 194 mm
Maximum axial force 500 N
Maximum moment 5 Nm
Break-out force (manually operated slide) 15 N
Displacement force (manually operated slide) 10 N
Other equipment Ρ4, 24" TFT monitor (1900 X 1080)
Hfedpfxjvx S Ape Aabon
Operating system Windows XP
Measurement and control software LabVIEW 2011
PC plug-in cards 1 card, NI PCI-6251,1 card, N1 PCI-7044
Drawer 500 mm (fully extended with automatic closing) Additional load 500 N
Drawer cabinet, lockable 3 drawers
The teach-in endurance test bench is a device for carrying out endurance tests
On test objects that can rotate and/or move translationally, e.g. cylinders
Locks, door handles, key functions.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We will be happy to answer any further questions you may have over the phone.
Listing

7,009 km
Spray and splash water test cabinet
WeissSWT 200/400
Call
Condition: excellent (used), Weiss
Type: SWT 200/400
Weiss spray and splash water test cabinet
The penetration of water into the housing is tested.
In conjunction with a timer, the test cycle can be automated with an adjustable test time of 3 seconds to 30 hours.
According to DIN VDE 0470 T1 or EN 60529 for tests according to protection classes IPX3 and IPX4.
The integrated circulation device means that water consumption can be reduced to a minimum.
Hjdpfxsvzz A Rj Aabofn
Features
Glass door with wiper
Pneumatic drive of the swivel tube
Adjustable swivel angle
Replaceable swivel tubes
Nozzle holder swivels and can be replaced
Adjustable water volume flow and measurement
Control of the test duration
Data for mechanical stress
Max. load with test material (evenly distributed over the surface)
Permissible test material weight for test material carrier (total) 25 kg
Spray radius 200 mm / 400 mm
Data for IP protection class tests
Swivel speed approx. 60°/s
Swivel angle IPX3 approx. ± 60°
Swivel angle IPX4 approx. ± 180° -10°
Dimensions:
External dimensions with control cabinet (D x W x H) approx. 1000 x 1350 x 1,900 mm
External (D x W x H) approx. 1000 x 1000 x 1,900 mm
Internal dimensions (D x W x H) 400 x 650 x 750 mm
Data for operation
Voltage: 3/N/PE AC 400V ±10% 50hz
Rated power 1.5 KW
Rated current 6.0 A
Weight: 375 kg
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We will be happy to answer any further questions you may have over the phone.
Listing

7,009 km
Climate test chamber with humidity 34 liters
VötschVCL 7003 -70°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VCL 7003
Air-cooled climatic test chamber
Test chamber capacity approx. 34 liters
Capacity for temperature tests:
Temperature range -70 to +180°C
Temperature deviation over time ±0.3 to ±1.0 K
Temperature homogeneity over space ±0.5 to ±2.0 K
Heating rate of change 4.0 K/min
Cooling rate of change 3.0 K/min
Heat compensation max. 550 W
Temperature calibration value +23°C and +80°C
Capacity for climatic tests:
Temperature range +10 to +95°C
Humidity range 10 to 98%
Hfedpov Tnd Ssfx Aabon
Humidity deviation over time ±1 to ±3%
Temperature deviation over time ±0.3 to ±0.5 K
Spatial temperature homogeneity ±0.5 to ±1.5 K
Climate calibration values +23 °C / 50% RH and +95 °C / 50% RH
Test room dimensions: Width 350 mm, Depth 300 mm, Height 310 mm
External dimensions: Width 640 mm, Depth 750 mm, Height 1730 mm
Electrical connection:
1/N/PE AC 230 V ±10%, 50 Hz
Rated current 11.0 A
Rated power, max. 2.5 kW
Sound pressure level 59 dB(A)
Refrigerant: R-404 A / R23
Weight approx. 130 kg
For your safety, please note the following information as a buyer!
The following steps are performed on our chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Discover more used machines
Listing

7,009 km
Climate test chamber Temp. -70 to 180°C
Weiss explosionsgeschütztWK-600/70 (I)-(II) 2 G EEx
Call
Condition: excellent (used), Weiss
Type: WK-600/70 (I)-(II) 2 G EEx /22605147
Weiss climate chamber water-cooled
(test room explosion-proof)
INERTIZATION WITH NITROGEN / EXPLOSION-PROOF TEST ROOM
Technical data:
Test chamber designation: WK-600/70 (I)-(II) 2 G EEx
External dimensions with hinges and door lock
Height 1995 mm, width 1090 mm, depth 1660 mm
External dimensions without hinges and door lock
Hedpfx Aajv Ewy Hsbsfn
Height 1995 mm, width 1000 mm, depth 1660 mm
Test room capacity: approx. 600 liters
Cold / heat operation -70 to 180°C
Climate operation 10 – 95°C
Humidity 10...98% r. H.
Temperature change per time
Cooling approx. 2.5 K/min
Heating approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 14 kW
Rated current: 25 A
On-site fuse: 32 A slow-blow
Permissible test item weight
Total load of the grate supports 80 kg
Test room floor 80 kg, grate insert 40 kg
Weight: 800 kg
Refrigerant: R 404A/R 23
(The air conditioning system's evaporator has been replaced)
For your safety as a buyer, the following information! The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing

7,009 km
Temperature test chamber -70°C to +180°C
VötschVTS 7027-15
Call
Condition: excellent (used), Heraeus Vötsch
Type: VTS 7027-15
Vötsch Temperature Test Chamber, Water-Cooled
Temperature Range: -70°C to +180°C
Temperature Rate of Change:
Temperature Deviation Temporarily ± 0.3 to ± 0.8 K
Temperature Deviation Spatially ± 0.5 to ± 2.0 K
Cooling Rate of Change: 18.0 °C
Heating Rate of Change: 17.0 °C
Test Chamber Dimensions: Width 580 x Depth 620 x Height 950 mm
External Dimensions: Width 870 x Depth 1895 x Height 1775 mm
Side Ports: 1 x 60 mm Ø and 2 x 120 mm Ø
Hjdpfswl Argox Aabefn
Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power 16 kW
Rated current 31 A
Refrigerant R452A / R23
Approx. 270 liters
Weight: 835 kg
For your safety, the following information is provided as a buyer!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing

7,009 km
Climate test chamber with humidity 190 liters
VötschVC 7018 -70 bis 180°C
Call
Condition: excellent (used), Vötsch
Type: VC 7018
Vötsch Climatic Test Chamber VC 7018 Water-Cooled
Touch Panel Control Unit
On the touch panel control unit, all control and operating commands can be triggered by simply touching the function symbols.
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Ports
The test chamber is equipped with port holes on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Feedthrough included in standard equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Characteristics for temperature tests:
Temperature range: -70°C to +180°C
Temperature ±0.1 to ±0.5 K
Spatial ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min
Cooling: 2.3 K/min
Characteristics for climatic tests:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% r.h. F.
Temperature deviation over time in the center of the usable space ± 0.1 to ± 0.3 K
Temperature deviation over space ± 0.5 to ± 1.0 K
Temperature gradient 1 to 2 K
Humidity deviation over time in the center of the usable space ± 1 to ± 3 %RH
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10 50Hz
Nominal power: 5.9 kW
Nominal current: 12.0 A
Connection cable: 3.5 m
Fuse protection: 16 A slow-blow, provided by the customer
Refrigerants: R-404A and R-23
Test chamber capacity: approx. 190 liters
Weight: approx. 460 kg net
For your safety, the following information is provided as a buyer!
The following steps are performed on our offered chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
Hjdpfx Aaewh Ttmsbjfn
We are happy to answer any further questions you may have over the phone.
Listing

7,009 km
Temperature test chamber -20°C...+140°C
TIRATTRE 2001 S
Call
Condition: excellent (used), Here we offer a TIRA temperature test chamber.
TIRA temperature test chamber air-cooled
The chamber has the option for an external test box with external sensor connection
can therefore also be used as an external temperature control unit.
Temperature range -20°C...+140°C
Temperature stability over time ± 0.1°C...± 0.3°C
External dimensions Width 860 mm x depth 1500 mm x height 2100 mm
Test chamber dimensions width 601 mm x depth 545 mm x height 692 mm
Electrical connection 400V +6% / -10% 50Hz 3P+N+PE
Rated current: 10.0 (max.17) A
Rated power: 5.2 (max.9.0) kW
Net weight: 735 kg
Refrigerant: R404A / R23
Hfedjnyh T Sjpfx Aabon
Type: TTRE 2001S
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,009 km
Shock test chamber
VötschVT 7012 S3
Call
Condition: excellent (used), Vötsch shock test chamber
Here we offer you a Vötsch shock test chamber.
Water cooled
Temp. range -80C to +220C
Hot chamber +50 to +220
Medium chamber -10 to +90
Cold chamber -80 to +70
Mains voltage 400V +-10% 3/N 50Hz
Rated current 30.5 A
Rated power 13.5 KW
Refrigerant VK : R 404A 3.00kg p*: 25bar
Refrigerant TK : R23 15bar p* : 25 bar
Condition: used / used
Type: VT 7012 S3
For you as a buyer for safety the following information!
Hedpfx Aon Avcujabjfn
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,009 km
Climatic test chamber
Feutron3702/06
Call
Condition: excellent (used), Feutron
Type: 3702/06
Water-cooled climatic test chamber
Technical data:
Test chamber nominal volume 2.0 m³
Dimensions: Test chamber exterior, with humidifier console
Width 2970 mm Height 2370 mm Depth 1530 mm
Rear wall
Minimum insertion dimensions: Width 2970 mm Height 2390 mm Depth 1550 mm
Test chamber: Width 2000 mm Height 1000 mm Depth 1000 mm
Double-leaf door, clear width Width 2000 mm Height 1000 mm
Heated viewing window, 2 pieces Width 500 mm Height 600 mm
Feed-through opening, 1 side panel left ∅ 75 mm
Temperature range: -40...100°C
Climatic range: 10...95°C
Temperature difference, temporal ≤ ± 0.5...± 1.0 ΔN/K
Change rates measured in the supply air without load
Cooling up to 2.0 on average K/min
Heating up to 2.0 on average K/min
Humidity range: 10...95 %r. F.
Humidity difference, temporal ≤ ± 3.0 %r. F.
Dew point range, temporary down to -5... 95°C
Refrigeration system: water-cooled semi-hermetic Bitzer system
Hedpfx Aok E Hnqjabjfn
Refrigerant: R507 (Μ-Κ1)
Air conditioning and dryer refrigeration system air-cooled /hermetic system
Refrigerant: R134a (Μ.ΚΚ)
Power supply:
Electrical mains connection: 400V 3/N/PE.AC,50Hz
Mains plug: CEE 5-роlig, 32 A, with 5.0 m cable
Max. simultaneous power requirement 10.0 kW
Supply line fuse: 3x 25, Char, C A
Degree of protection IP20
Weight: 1300 kg
Condition: used
Scope of delivery: (see picture)
(Subject to changes and errors in the technical data and specifications)
We will be happy to answer any further questions you may have on the phone.
Listing

7,009 km
Vibration temperature test chamber
RS-SimulatorenVTS 600/45 RS -45°C...+180°C
Call
Condition: excellent (used), Here we offer a temperature test cabinet.
Water cooled
Temperature range: -45°C to +180°C
External dimensions: Width 1300 mm x height 2100 mm x depth 2250 mm
Test chamber dimensions: Width 840 mm x height 840 mm x depth 840 mm
Unit part : width 2300 mm x height 2000 mm x depth 1300 mm
Hsdemn Rciepfx Aabofn
Average heating rate: approx. 3 K/min
Average cooling rate: approx. 2 K/min
Power consumption: 15 A
Connection voltage: 3x400V/N/PE 50Hz
Weight: approx. 1000 kg
Type: VTS 600/45 RS
Refrigerant: R452
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,009 km
Burst test bench
LindnerAGB Berstprüfstand TMM4
Call
Condition: excellent (used), Lindner Bursting Test Stand
Here we offer a Lindner burst test stand.
AGB Bursting Test Stand TMM4
Technical data:
AGB Bursting Test Stand TMM4
Year of manufacture 2015
Rated voltage: 3/N/PE AC 400V
Rated power: 5,5 kW
Temperature range chamber: RT ... 180°C
Temperature range medium: RT ... 135°C
Pressure range: 0 ... 5 bar
Compressed air supply: 6-8 bar
Test medium: glycol / water
Heat transfer oil Fragoltherm Q-HTF
Dimensions: length 2150 mm x width 1050 mm x 2160 mm
Operating voltage: 3/N/PE AC 400V +/-10% 50Hz
power: 5,5kW
rated current: 8A
Back-up fuse: 16A
Control voltage: 24VDC
PLC system: S7-1215 DC/DC/RLY
For the commissioning of the burst test bench the following items are necessary:
Pump, cooling tower & fire alarm panel these are not supplied.
Type: AGB burst test rig TMM4
weight approx. 705 kg
Hfjdpelx A T Djfx Aabsn
Condition: used / used
Scope of supply: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,009 km
Temperature test chamber
WEISSWT-600/70
Call
Condition: excellent (used), Weiss temperature test chamber
Here we offer a temperature test chamber.
Weiss temperature test chamber water cooled
Technical data:
Test cabinet designation: WT-600/70
Outer dimensions with hinges and door lock
height 1995 mm, width 1090 mm, depth 1660 mm
Outer dimensions without hinges and door lock
height 1995 mm, width 1000 mm, depth 1660 mm
Internal dimensions:
Height 950 mm, width 800 mm, depth 800 mm
Test chamber capacity: approx. 600 liters
cold / heat operation -70°C to 180°C
Temperature change per time
cooling approx. 2.5 K/min
Heating up approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 9.1 kW
Rated current: 19 A
Fuse on site: 32 A slow blow
Hsdpfxeiqk Abo Aabsfn
Permissible test material weight
Total load of grate supports 80kg
test chamber floor 80kg, insert grate 40kg
Refrigerant: R 404A/R23
Weight: 675kg
Type: WT-600/70
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,009 km
Temperature shock test chamber
Weiss130 Liter TS 130 *
Call
Condition: excellent (used), Here we offer a temperature shock test cabinet.
White Temperature Shock Test Cabinet Air Cooled
Specification:
Temperature range hot chamber +60°C ... +220°C
Temperature range cold chamber -10°C ... -80°C
Change hot/cold chamber 10 s
Temperature constancy ±1 K
Dimensions and other data:
External dimensions: Height 1990 mm
Width ( without and with door hinge ) without....approx. 1820 mm with....approx. 1850 mm
Depth ( without and with test room door ) without....ca. 900 mm with....ca. 1155 mm
Hfedpfx Aaslgux Aobon
Dimensions of the lifting basket ( test chamber ) height 450 mm, width 500 mm, depth 600 mm
volume 130 liters
Test space load max. 20 kg
Test chamber floor load max. 20 kg
Cooling water pressure min. 2 ... max. 6 bar
Max. Backup fuse 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of unit approx. 65 dB(A)
Cooling cascade water cooled
Connected load: 3/N/PE/AC 400V ±10% 50Hz /14,0 kW
nominal current 26,0 A
Refrigerant R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,009 km
Temperature test chamber 270 liters
VötschVTS³ 7027-25 -72°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VTS³ 7027-25
Heraeus Vötsch temperature test chamber, water-cooled
Performance data:
With temperature change rate of 25 K/min
Test chamber dimensions Height 750 mm Width 580 mm Depth 615 mm
External dimensions Height 1775 mm Width 780 mm Depth 1895 mm
Temperature range -72°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5
Temperature homogeneity in space ± 0.5 to ± 2.0
Temperature change rate cooling 25 K/min
Temperature change rate heating 25 K/min
Heat compensation at -20 °C 8000 W
Heat compensation at +20 °C 8000 W
Test volume: 270 liters
2x lateral feed-through ∅ 125 cm
1x side feed-through ∅ 50 cm
Cabinet is water-cooled
Test room lighting:
LED strip 24 V, 6.8 W / 2x halogen bulb 24 V, 50 W
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal power: 26 KW
Rated current: 44 A
Refrigerant: R-452A and R-23
Weight: approx. 980 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Hodpetz Rqmjfx Aabofn
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,009 km
Climate test chamber with humidity
VötschVC³ 0100 0°C bis + 90°C
Call
Condition: excellent (used), Vötsch
Type: VC³ 0100
Vötsch climatic test chamber, air-cooled
Test chamber dimensions: Height 950 mm x width 1100 mm x depth 950 mm
Device dimensions: Height 2000 mm x width 1300 mm x depth 1916 mm
Test chamber 990 liters
Temperature tests:
Minimum temperature -0°C
Maximum temperature +90°C
Temperature change rate cooling 0.2 K/min
Temperature change rate heating 0.5 K/min
Temperature deviation in time ± 0.1 to ± 0.5 K
Temperature homogeneity in space ± 0.5 to ± 1.0 K
Heat compensation at +20 °C 350W
Climatic tests:
Minimum temperature +10°C
Maximum temperature +90°C
Dew point temperature range +4°C to +89.5°C
Humidity range 10 to 98% r. h.
Humidity deviation over time ± 1 to ± 3% r. h.
Temperature deviation temporal ± 0.1 to ± 0.3K
Temperature homogeneity in space ± 0.5 to ± 1.0K
Voltage: 1/N/PE AC 230V±10% 50Hz
Hedpfstz T D Aox Aabsfn
Rated power: 2.3 kW
Rated current: 10 A
Refrigerant: R-404A
Weight approx. 1400 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,009 km
Temperature test chamber
CTSTSR-30/1000
Call
Condition: good (used), CTS
Type: TSR-30/1000
Hfedpferivfcsx Aabon
Water-cooled
The type designation of the CTS enclosure series is made up as follows:
z. e.g. type TSR -30/1000
1) T means: Temperature
2) S means: stress screening
3) R means: external conditioning
4) -30 means: lower temperature -30 °C
5) 1000 means: 1000 liter test chamber volume
Technical performance data:
A) TSR-30/1000 basic device without hose connections,
i.e. when used as a stand-alone temperature test chamber
Temperature tests:
Temperature range -40°C to +180°C
Final temperature -45°C
Temperature deviation ≤ ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 6.0 K/min
Cooling 5.0 K/min
Heat radiation
approx. 5000 W at +20°C
approx. 4200 W at ± 0°C
approx. 3000 W at -20°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment.
Air volume flow
approx.2000m³/h
B) TSR-30/1000 basic unit with hose connections,
for connection to an external test room provided by the customer
Temperature tests:
Temperature range -30°C to +170°C
Temperature deviation ≤ ±0.1 to 0.5 K in time
Average rate of temperature change,
measured with short-circuited circuit
Heating 4.0 K/min
Cooling 4.0 K/min
in the range from +150°C to -10°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment,
measured with short-circuited circuit
Attention: The external test chamber provided by the customer must be absolutely tight and appropriately insulated,
any feed-throughs must be optimally sealed on site.
Dimensions:
Test volume 1000 liters
Air circulation connection Ø 200 mm
Test chamber dimensions Height 900 mm Width 1000 mm Depth 1100 mm
External dimensions Height 1950 mm Width 1270 mm Depth 2245 mm
Technical design:
Refrigeration unit:
water-cooled, low-noise, fully hermetic
Infinitely variable capacity adjustment through
electronic monitoring and control system,
environmentally friendly refrigerant R404A
Door:
Fully opening door, door hinge on the left,
one-handed operation, lockable.
Shelf:
Stainless steel, support surface 970 x 980 mm
Max. load per shelf 35 kg
Total load with max. shelf load 100 kg
Test area lighting: Halogen lamp 20 W, 12 V
Control:
- 32 bit controller
- LCD control panel
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 13.3 kW
Protection class IP 22
Sound pressure level < 60 dB(A)
Weight approx. 850 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,009 km
Temperature test chamber 1000 liters
CTST-55/1000 Li -50°C bis 100°C
Call
Condition: excellent (used), CTS
Temperature test chamber T-55/1000 Li water-cooled
Temperature range: -50°C to +100°C
Rated voltage: 400V 3/N 50Hz
Rated power: 9.5 kW
Nominal current: 18 A
Compressor: TFH2511Z / TFH2511Z Refrigerant R404A/R23
The type designation of the CTS cabinet series is composed as follows:
z. e.g. type T -55/1000/Li
1) T means: temperature
2) -55 means: lower temperature -55 °C
Hfedpfx Aovba Raeaben
3) 1000 means: 1000 liter test chamber volume
4) Li means: special equipment for
tests with lithium-ion accumulators
Control:
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoints
Error messages in plain text
Ethernet interface
RS 232 interface
Free switching channels for on-site
test material control
Test room lighting:
energy-efficient, high-intensity LED light strip mounted on the door
Insert grid:
Stainless steel, support surface 970 x 980 mm
Load per shelf max. 35 kg
Total load with max. grating load 100 kg
1a Feed-through NW50
1b Feed-through 2x NW125
1c Entry port 2x Rp 314°
for Minimax
Technical performance data:
Temperature tests:
Temperature range -50°C to +100°C
Temperature deviation ≤ ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat compensation
approx. 4000 W at +20°C
approx. 2200 W at -40°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without heat compensation and without additional equipment.
Options may affect the performance data.
Dimensions:
Test volume 1000 liters
Test chamber dimensions Height, approx. 1000 mm, width, approx. 860 mm, depth, approx. 1100 mm
External dimensions Height, approx. 1950 mm, width, approx. 1270 mm, depth, approx. 1900 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Nominal current 18 A
Rated power 9.5 kW
Protection class IP 54
Sound pressure level < 58 dB(A)
(according to DIN EN ISO 3744
measured at a distance of 1 m from the front)
Mass approx. 1000 kg
Heat output to the installation room 10.4 kW
Cooling unit:
water-cooled, low-noise, fully hermetic
Infinitely variable output adjustment via electronic monitoring and control system,
environmentally friendly refrigerant R404A/R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,009 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Hfedpjun Rv Nsfx Aabsn
We will be happy to answer any further questions you may have on the phone.
Listing

7,009 km
Temperature shock test system
RS-SimulatorenST2K320/45
Call
Condition: excellent (used), RS Simulators
Type: ST2K320/45
Hfedstqcu Eepfx Aabjn
Water-cooled shock test system
Working climate area
Temperatures in the upper test chamber
Temperature range: +40 °C to +180 °C
Temperatures in the lower test chamber
Temperature range: -40 °C to +100 °C
Temperature: +12 °C to +30 °C
Humidity: 25% to 75% relative humidity
Dimensions Width 1100 mm Height 2300 mm Depth 2300 mm
Test chamber dimensions: Width 470 mm Depth 700 mm Height 440 mm
Electrical power supply:
Voltage: 3x400V/N/PE / 50Hz
Refrigerant: R404A/2.5 kg
Chamber: approx. 850 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Trust Seal
Dealers certified through Machineseeker

Listing

7,009 km
Temperature test chamber spraying device
VötschVBT 03/500 500 Liter -30 bis 80°C
Call
Condition: excellent (used), Vötsch
Type: VBT 03/500
Hfodewc Nvgspfx Aabjn
Air-cooled
Temperature test chamber with spray device
Technical description:
Data for temperature tests without water:
Temperature range -30°C to +80°C
Temperature deviation in steady state
according to IEC 60068-3-5 dependent on the test chamber temperature
over time ± 1 K
Temperature change rate according to IEC 60068-3-5
Heating: approx. 2 K/min.
Cooling: approx. 2 K/min.
Data for temperature tests with water
Temperature range +5°C to +80°C
Possible water level -10 mm to 540 mm
Water level = -10 mm
The water level is below the insert grid
Water level = 0 mm
The water level is at the top edge of the insert grid
Data for standard spray device
Number of spray nozzles: 6
Spray volume per nozzle: 0.5 l/min
Data for spray device according to EN 539-2, Method B
Number of spray nozzles: 6
Spray volume per nozzle: 4.5 l/min
Additional flooding nozzles: 2
Spray volume of additional nozzle: 6 l/min
Compressed air consumption: approx. 3 m³/h
Data for water tank with pre-temperature control
Volume: approx. 2000 l
Temperature range for pre-temperature control +5°C to +40°C
Temperature change duration
Cooling of +18°C to +5°C approx. 15 h
Heating from +15°C to +40°C approx. 10 h
Installation and Operation Data:
Test chamber: Width 1120 mm, Depth 840 mm, Height 540 mm
Housing: Width 2700 mm, Depth 1300 mm, Height 1575 mm
Water tank: Width 1100 mm, Depth 800 mm, Height 2200 mm
Plug-ins
1 50 mm diameter plug installed on the left
Test chamber capacity: approx. 500 liters
Refrigerant R-404a
Electrical connection:
Nominal voltage 3/N/PE AC 400V ± 10% 50Hz
Nominal power approx. 26 kW
Nominal current approx. 44.0 A (neutral conductor loaded)
Fuse protection 63 A gG, on-site
Weight approx. 890 kg net
For your safety, please note the following information!
The following steps are carried out on our chambers in advance:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing

7,009 km
Climate test chamber with humidity 190 liters
VötschVC 7018 -70 bis 180°C
Call
Condition: excellent (used), Vötsch
Type: VC 7018
Vötsch Climatic Test Chamber VC 7018 Water-Cooled
Touch Panel Control Unit
On the touch panel control unit, all control and operating commands can be triggered by simply touching the function symbols.
Adjustable Feet
Hfjdswgaykjpfx Aabon
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Ports
The test chamber is equipped with port holes on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Feedthrough included in standard equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Characteristics for temperature tests:
Temperature range: -70°C to +180°C
Temperature ±0.1 to ±0.5 K
Spatial ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min
Cooling: 2.3 K/min
Characteristics for climatic tests:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% r.h. F.
Temperature deviation over time in the center of the usable space ± 0.1 to ± 0.3 K
Temperature deviation over space ± 0.5 to ± 1.0 K
Temperature gradient 1 to 2 K
Humidity deviation over time in the center of the usable space ± 1 to ± 3 %RH
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10 50Hz
Nominal power: 5.9 kW
Nominal current: 12.0 A
Connection cable: 3.5 m
Fuse protection: 16 A slow-blow, provided by the customer
Refrigerants: R-404A and R-23
Test chamber capacity: approx. 190 liters
Weight: approx. 460 kg net
For your safety, the following information is provided as a buyer!
The following steps are performed on our offered chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing

7,009 km
Shock test chamber -80°C to +220°C
VötschVT 7012 S2
Call
Condition: excellent (used), Here we offer Vötsch shock test chamber.
Temperature shock test chamber water cooled
Two-chamber design
Warm chamber:
The temperature control of the warm chamber ranges from +50°C to +220°C
Temperature deviation in time in the center of the chamber ± 1 K
Temperature deviation spatially ± 2 K
Temperature change rate
heating 11 K/min
cold chamber:
the cold chamber from -80°C to +70°C
Temperature deviation temporally in useful space center ± 1 K
temperature deviation spatially ± 2 K
Temperature change rate
heating 2 K/min
cooling 3 K/min
Test chamber volume 125 liters
Temperature range hot chamber +50°C to +220°C
Temperature range cold chamber -80°C to +70°C
Test chamber dimensions width 470mm depth 650mm height 410mm
Outer dimensions width 930mm depth 2115mm height 1970+mm
Feedthrough ∅ 67mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant R404A / R23
Weight: 1000 kg
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: VT 7012 S2
Hodpsigg Hnjfx Aabofn
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,009 km
Temperature test chamber 335 liters
VötschVTS 7034-5 -70°C bis +180°C
Call
Condition: excellent (used), Heraeus Vötsch temperature test chamber
Here we offer you a Heraeus Vötsch temperature test chamber.
Heraeus Vötsch temperature test chamber water cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6,5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
Outer dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Hodpfsir D U Dox Aabsfn
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free field measurement) < 69dB (A)
side entry 5,5 cm / 12,5 cm
cabinet is water cooled
Refrigerant: R 452A and R 23
weight approx. 570 kg
Type: VTS 7034-5
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
We make it easier for you to find: "rockwell hardness test"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Rockwell Hardness Test (12,449)
Search Machineseeker now with more than 2,00,000 used machines:Browse through the most popular machine descriptions:
This may be of interest to you