Climate test chamber 190 litersVötsch
VC³ 7018 -70°C bis +180°C
Climate test chamber 190 liters
Vötsch
VC³ 7018 -70°C bis +180°C
Condition
Used
Location
Borken 

Show images
Show map
Machine data
Price & Location
- Location:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Call
Details about the offer
- Listing ID:
- A20748272
- Reference number:
- 24927
- Update:
- 12.12.2025
Description
Vötsch
Type: VC³ 7018
Vötsch Air-Cooled Climatic Test Chamber
Temperature Test:
Temperature Range: -70°C to +180°C
Temperature Rate: Heating 4 K/min
Temperature Rate: Cooling 3 K/min
Climatic Test:
+10°C to +95°C
Humidity Range: 10% to 98% RH F.
Gusdpfx Ahox Hg Uuo Dsk
Temperature deviation over time: ± 0.1 to ± 0.3 K
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1550 mm x Height 1800 mm
Test chamber volume: 190 liters
Nominal voltage: 400 V
Nominal current: 14 A
Nominal power: 5.5 kW
Heat compensation 1500 W (at 20+)
Weight: approx. 460 kg
For your safety, please note the following information!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
The listing was translated automatically. Translation errors are possible.
Type: VC³ 7018
Vötsch Air-Cooled Climatic Test Chamber
Temperature Test:
Temperature Range: -70°C to +180°C
Temperature Rate: Heating 4 K/min
Temperature Rate: Cooling 3 K/min
Climatic Test:
+10°C to +95°C
Humidity Range: 10% to 98% RH F.
Gusdpfx Ahox Hg Uuo Dsk
Temperature deviation over time: ± 0.1 to ± 0.3 K
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1550 mm x Height 1800 mm
Test chamber volume: 190 liters
Nominal voltage: 400 V
Nominal current: 14 A
Nominal power: 5.5 kW
Heat compensation 1500 W (at 20+)
Weight: approx. 460 kg
For your safety, please note the following information!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2012
Send inquiry
Telephone & Fax
+49 2861 ... show
These listings may also fit your interest.
Listing
Borken
7,009 km
Climate test chamber with humidity 190 liters
VötschVC 7018 -70 bis 180°C
VötschVC 7018 -70 bis 180°C
Listing
Borken
7,009 km
Climate test chamber with humidity
WeissSB2/500/80 -75°C bis +180°C
WeissSB2/500/80 -75°C bis +180°C
Listing
Borken
7,009 km
Climate test chamber with humidity 190 liters
VötschVC 7018 -70 bis 180°C
VötschVC 7018 -70 bis 180°C
Listing
Eislingen/Fils
6,803 km
Coordinate Measuring Machine
ZETT-MESSAMS 08/10
ZETT-MESSAMS 08/10
Listing
Germany
6,760 km
Universal Oven
MemmertUF30
MemmertUF30
Listing
Tönisvorst
7,039 km
Measuring Machine
ZEISSUPMC 850 Carat
ZEISSUPMC 850 Carat
Listing
Borken
7,009 km
Pendulum impact tester 5.5 J
Zwick RoellHIT5.5P
Zwick RoellHIT5.5P
Listing
Borken
7,009 km
Temperature cabinet 990 liters
WeissWT3-1000/40 -40°C bis +180°C
WeissWT3-1000/40 -40°C bis +180°C
Listing
Borken
7,009 km
Climatic chamber
VötschVC³ 4100
VötschVC³ 4100
Listing
Borken
7,009 km
Temperature chamber
WEISSWT11-1000/70/5
WEISSWT11-1000/70/5
Your listing has been deleted successfully
An error has occurred