Climate test chamber XXL 3300 litersVötsch
VC 7330/S -70°C bis +180°C
Climate test chamber XXL 3300 liters
Vötsch
VC 7330/S -70°C bis +180°C
Condition
Used
Location
Borken 

Show images
Show map
Machine data
Price & Location
- Location:
- Einsteinstraße 8a, 46325 Borken, DE
Call
Details about the offer
- Listing ID:
- A17515278
- Reference number:
- 24401
- Update:
- 24.03.2025
Description
Vötsch
Type: VC 7330/S
Water-cooled climate chamber
Room volume: 3300 liters
Data for temperature tests:
Temperature range: -70°C to +180°C
Spatial temperature deviation: ± 1 to ± 2 K (corresponds to temperature gradient) (2 to 4)
Temperature fluctuation over time in the center of the usable space: ± 0.5 - 1 K
Temperature change rate (according to IEC 60068-3-5)
Heating: 1.5 K/min
Cooling: 1.5 K/min
Data for climate tests:
Temperature range: +10 to +90°C
Humidity range: 10% RH up to 98% RH
Temperature fluctuation over time ± 0.2 to -0.5 K
Humidity fluctuation over time ± 1% RH to ± 3% RH
Dew point range +5°C to +89°C
Mechanical load data:
of the test chamber floor 150 kg
Maximum chamber floor load 250 kg
Dimensions of the test chamber: Width 2000 mm x Depth 1150 mm x Height 1510 mm
External dimensions: Width 4000 mm x Depth 1450 mm x Height 2100 mm
Operating data:
Test chamber lighting: Halogen bulb 12 V, 20 W
Rated voltage: 3/N/PE AC 400V±10% 50Hz
Rated power 15 kW, Rated current 34 A
External control via the RS 232 interface is of course possible.
Refrigerant: R404A / R23
Weight: 1550 kg
For your safety, the following information is provided as a buyer!
The following steps are performed on our chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
Gksdsu Au Erepfx Aaboc
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
The listing was translated automatically. Translation errors are possible.
Type: VC 7330/S
Water-cooled climate chamber
Room volume: 3300 liters
Data for temperature tests:
Temperature range: -70°C to +180°C
Spatial temperature deviation: ± 1 to ± 2 K (corresponds to temperature gradient) (2 to 4)
Temperature fluctuation over time in the center of the usable space: ± 0.5 - 1 K
Temperature change rate (according to IEC 60068-3-5)
Heating: 1.5 K/min
Cooling: 1.5 K/min
Data for climate tests:
Temperature range: +10 to +90°C
Humidity range: 10% RH up to 98% RH
Temperature fluctuation over time ± 0.2 to -0.5 K
Humidity fluctuation over time ± 1% RH to ± 3% RH
Dew point range +5°C to +89°C
Mechanical load data:
of the test chamber floor 150 kg
Maximum chamber floor load 250 kg
Dimensions of the test chamber: Width 2000 mm x Depth 1150 mm x Height 1510 mm
External dimensions: Width 4000 mm x Depth 1450 mm x Height 2100 mm
Operating data:
Test chamber lighting: Halogen bulb 12 V, 20 W
Rated voltage: 3/N/PE AC 400V±10% 50Hz
Rated power 15 kW, Rated current 34 A
External control via the RS 232 interface is of course possible.
Refrigerant: R404A / R23
Weight: 1550 kg
For your safety, the following information is provided as a buyer!
The following steps are performed on our chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
Gksdsu Au Erepfx Aaboc
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Send inquiry
Telephone & Fax
+49 2861 ... show
Your listing has been deleted successfully
An error has occurred