Climatic chamber with humidity, 34 litersWeiss
WKL 34/60 -60°C bis 150°C
Climatic chamber with humidity, 34 liters
Weiss
WKL 34/60 -60°C bis 150°C
Condition
Used
Location
Borken 

Machine data
- Machine type:
- Climatic chamber with humidity, 34 liters
- Manufacturer:
- Weiss
- Condition:
- excellent (used)
Price & Location
- Location:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Call
Details about the offer
- Listing ID:
- A22199292
- Reference number:
- 24134
- Update:
- 24.06.2026
Description
Weiss
Type: WKL 34/60
Weiss Climate Chamber, Air-Cooled
Refrigerant converted to R-452A
-60°C to 150°C
Volume: 34 liters
Installed in basic configuration:
R1 NW 50 mm
L1NW 120 mm
Internal dimensions: Height 310 mm, Width 324 mm, Depth 300 mm
External dimensions: Height 1740 mm, Width 630 mm, Depth 970 mm
Performance data for temperature tests:
Temperature range -60 to +150 °C
Temperature differences in steady state, according to IEC 60068-3-5
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 1 K ± 1 to ± 2 K
Temperature deviation spatially (corresponds to temperature gradient) 2 to 4
Temperature change rate (according to IEC 60068-3-5)
Heating 2.5 K/min
Cooling 3 K/min
Heat compensation max. 550 W
Performance data for climate tests:
Temperature range +10 to +95 °C
Humidity range 10 to 98 % RH
Temperature and humidity differences (in steady state, according to IEC 60068-3-5)
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 0.5 K
Temperature deviation spatially ± 0.5 to ± 1.5
(corresponds to temperature gradient) 1 to 3
Humidity fluctuation over time in the center of the usable space ± 3 to ± 5 % RH
Operating data:
Test chamber lighting Halogen bulb 12V, 20W
Rated voltage 1/N / PE AC 230 V ± 10 % 50 Hz
Rated power 2.5 kW
Rated current 11 A
Fuse on customer side 16A slow-blow
Heat dissipation of air-cooled test chambers
Max. heat dissipation to the environment 1700 W
Fgedpfx Aezgr U Redrof
Refrigerant: R-452A / R23
Weight: 140 kg
For your safety as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
The listing was translated automatically. Translation errors are possible.
Type: WKL 34/60
Weiss Climate Chamber, Air-Cooled
Refrigerant converted to R-452A
-60°C to 150°C
Volume: 34 liters
Installed in basic configuration:
R1 NW 50 mm
L1NW 120 mm
Internal dimensions: Height 310 mm, Width 324 mm, Depth 300 mm
External dimensions: Height 1740 mm, Width 630 mm, Depth 970 mm
Performance data for temperature tests:
Temperature range -60 to +150 °C
Temperature differences in steady state, according to IEC 60068-3-5
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 1 K ± 1 to ± 2 K
Temperature deviation spatially (corresponds to temperature gradient) 2 to 4
Temperature change rate (according to IEC 60068-3-5)
Heating 2.5 K/min
Cooling 3 K/min
Heat compensation max. 550 W
Performance data for climate tests:
Temperature range +10 to +95 °C
Humidity range 10 to 98 % RH
Temperature and humidity differences (in steady state, according to IEC 60068-3-5)
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 0.5 K
Temperature deviation spatially ± 0.5 to ± 1.5
(corresponds to temperature gradient) 1 to 3
Humidity fluctuation over time in the center of the usable space ± 3 to ± 5 % RH
Operating data:
Test chamber lighting Halogen bulb 12V, 20W
Rated voltage 1/N / PE AC 230 V ± 10 % 50 Hz
Rated power 2.5 kW
Rated current 11 A
Fuse on customer side 16A slow-blow
Heat dissipation of air-cooled test chambers
Max. heat dissipation to the environment 1700 W
Fgedpfx Aezgr U Redrof
Refrigerant: R-452A / R23
Weight: 140 kg
For your safety as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
The listing was translated automatically. Translation errors are possible.
Send inquiry
Telephone & Fax
+49 2861 ... show
These listings may also fit your interest.
Listing
Eichenzell
6,806 km
Milling machine
isel GermanyiCV 4030EC
isel GermanyiCV 4030EC
Listing
Eislingen/Fils
6,804 km
Vertical turning and grinding centre
EMAGVLC 100 GT
EMAGVLC 100 GT
Listing
Bydgoszcz
6,269 km
BALANCING MACHINE
CIMATCMT-50VSTR
CIMATCMT-50VSTR
Listing
Dieren
7,063 km
Balancing Machine with Vertical Shaft
CEMBVPECS 30
CEMBVPECS 30
Listing
Borken
7,009 km
Climatic test chamber -42 to +190°C
MemmertCTC 256 256 Liter
MemmertCTC 256 256 Liter
Listing
Odesa
5,211 km
Vertical balancing machine
97V10 (10kg)
97V10 (10kg)
Listing
Contamine-sur-Arve
7,060 km
Vertical cnc lathe
INDEXV100
INDEXV100
Listing
Borken
7,009 km
Climatic chamber temperature and humidity
EspecPL-3KPH -40°C bis 180°C
EspecPL-3KPH -40°C bis 180°C
Listing
Dietfurt an der Altmühl
6,666 km
Temperature chamber
VötschVT 7004
VötschVT 7004
Listing
Borken
7,009 km
Climate test chamber with humidity
CTSCS-70/350 350 Liter -70°C /+180°C
CTSCS-70/350 350 Liter -70°C /+180°C
Your listing has been deleted successfully
An error has occurred