New digitally controlled MFC mass flow controller for gas, SLA5800 Biotech MassFlowControllerBROOKS INSTRUMENT
SLA585081BAB1A2S1
New digitally controlled MFC mass flow controller for gas, SLA5800 Biotech MassFlowController
BROOKS INSTRUMENT
SLA585081BAB1A2S1
Fixed price plus VAT
€1,000
Condition
Used
Location
Hessisch Lichtenau 

Show images
Show map
Machine data
- Machine type:
- New digitally controlled MFC mass flow controller for gas, SLA5800 Biotech MassFlowController
- Manufacturer:
- BROOKS INSTRUMENT
- Model:
- SLA585081BAB1A2S1
- Condition:
- used
Price & Location
Fixed price plus VAT
€1,000
- Location:
- 37235 Hessisch Lichtenau
Call
Machine sale

Found a new machine? Now turn the old one into cash.
Achieve the best price through Machineseeker.
More about selling machinery
More about selling machinery
Details about the offer
- Listing ID:
- A17208372
- Reference number:
- 61764
- Update:
- 14.09.2025
Description
SLA5800 Biotech - MFC - Digitally controlled mass flow controller for gas, Mass Flow Controller
elastomer-sealed mass flow controller, flow control, flow meter, flow controller, thermal mass flow
BROOKS INSTRUMENT Type SLA585081BAB1A2S1
Ser. No. 01C00500222
Year of manufacture 2020 (new / unused in original packaging)
SLA5800 Biotech series
Option package Biotech Premium Packet Code T
Mains connection 13.5 - 27 VDC (plug M8, 5 pin, male)
Power consumption max. 10 watts
PROFINET interface (2x RJ-45)
Visual display 2 LEDs (NET / MOD)
Gas connection 6 mm Swagelok
Valve design Normally closed
User gas O2 (oxygen) Active - Multiple / O2 (oxygen), N2 (nitrogen), CO2 (carbon dioxide), AIR (air)
Calibration gas N2 (nitrogen)
Flow control ranges (full scale) 20000 sccm (20 liters / minute)
Maximum inlet pressure 4500 psi (300 bar)
Normal operation Pressure differential 60 psig (4 bar)
Dkjdpfx Aheuqgbysxju
Control range 2% to 100% of full scale (range of mechanism)
Typical accuracy from 20 to 100 % ± 0.9 % of set point for 20 to 100 % of full scale
Typical accuracy from 2 to 20 % ± 0.18 % of full scale for 2 to 20 % of full scale
Repeatability ± 0.2 % of the measured value
Resolution 0.1 % of full scale
Typical response time of the controller
The listing was translated automatically. Translation errors are possible.
elastomer-sealed mass flow controller, flow control, flow meter, flow controller, thermal mass flow
BROOKS INSTRUMENT Type SLA585081BAB1A2S1
Ser. No. 01C00500222
Year of manufacture 2020 (new / unused in original packaging)
SLA5800 Biotech series
Option package Biotech Premium Packet Code T
Mains connection 13.5 - 27 VDC (plug M8, 5 pin, male)
Power consumption max. 10 watts
PROFINET interface (2x RJ-45)
Visual display 2 LEDs (NET / MOD)
Gas connection 6 mm Swagelok
Valve design Normally closed
User gas O2 (oxygen) Active - Multiple / O2 (oxygen), N2 (nitrogen), CO2 (carbon dioxide), AIR (air)
Calibration gas N2 (nitrogen)
Flow control ranges (full scale) 20000 sccm (20 liters / minute)
Maximum inlet pressure 4500 psi (300 bar)
Normal operation Pressure differential 60 psig (4 bar)
Dkjdpfx Aheuqgbysxju
Control range 2% to 100% of full scale (range of mechanism)
Typical accuracy from 20 to 100 % ± 0.9 % of set point for 20 to 100 % of full scale
Typical accuracy from 2 to 20 % ± 0.18 % of full scale for 2 to 20 % of full scale
Repeatability ± 0.2 % of the measured value
Resolution 0.1 % of full scale
Typical response time of the controller
The listing was translated automatically. Translation errors are possible.
Seller
Send inquiry
Telephone & Fax
+49 5602 ... show