Carbon-sulfur analysisLeco
C 230 Anorganische Elementaranalytik
Carbon-sulfur analysis
Leco
C 230 Anorganische Elementaranalytik
Fixed price plus VAT
€5,700
Condition
Used
Location
Borken 

Show images
Show map
Machine data
Price & Location
Fixed price plus VAT
€5,700
- Location:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Call
Details about the offer
- Listing ID:
- A20546160
- Reference number:
- 24420
- Update:
- 17.11.2025
Description
Leco
LECO C230 CARBON ANALYZER
Carbon Determination C230
The LECO C230 Carbon Determiner is a microprocessor-based, software-controlled instrument for measuring the carbon and sulfur content in metals, ores, ceramics, and other inorganic materials. The C230 uses an induction furnace and measures carbon via infrared absorption.
The infrared (IR) source consists of a nichrome wire heated by resistance up to 8,500 °C. The IR source emits visible energy as well as all wavelengths of the infrared spectrum. For description purposes, carbon dioxide can be used; the same principle applies for sulfur detection. Carbon dioxide absorbs IR energy at a specific wavelength within the IR spectrum. Energy from the IR source is absorbed as the gas passes through the cell, thereby preventing it from reaching the IR detector.
One IR cell is used both as a reference and for measurement. The total carbon content in the form of carbon dioxide is captured continuously and simultaneously. The initial reference level or baseline for the detector is set by passing oxygen through the cell to remove any remaining atmospheric gases.
Technical Data:
Required Gases:
Carrier gas: Oxygen, 99.5% pure, 40 psi
Pneumatic gas: Compressed air, nitrogen, or argon, 40 psi (2.76 bar), source must be oil- and water-free
Gas flow (based on nominal analysis time):
Measurement: 3 liters per analysis
Pneumatic: 1 liter per analysis
Regulators:
Oxygen: 501-291 O₂ pressure regulator
Compressed air: 766-036 air pressure regulator
Ndjdsxxaxuspfx Afhjd
Inert gas: 764-216 inert gas regulator
Furnace: Induction, 18 MHz, 2.2 kW
Data Transfer: Included
Data Storage:
Without PC: 10 sample weights, 50 results, 5 methods
Without PC: Internal memory / Optional external display
Without PC: LCD display (16 x 26 characters)
Power Requirements:
Determinator: 230 V~, ± 10%, 50/60 Hz, single phase, 15 amp max
Operating current: 12 A
Standby current: 4 A
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in technical data; specifications subject to confirmation!)
For further questions, please feel free to contact us by phone.
The listing was translated automatically. Translation errors are possible.
LECO C230 CARBON ANALYZER
Carbon Determination C230
The LECO C230 Carbon Determiner is a microprocessor-based, software-controlled instrument for measuring the carbon and sulfur content in metals, ores, ceramics, and other inorganic materials. The C230 uses an induction furnace and measures carbon via infrared absorption.
The infrared (IR) source consists of a nichrome wire heated by resistance up to 8,500 °C. The IR source emits visible energy as well as all wavelengths of the infrared spectrum. For description purposes, carbon dioxide can be used; the same principle applies for sulfur detection. Carbon dioxide absorbs IR energy at a specific wavelength within the IR spectrum. Energy from the IR source is absorbed as the gas passes through the cell, thereby preventing it from reaching the IR detector.
One IR cell is used both as a reference and for measurement. The total carbon content in the form of carbon dioxide is captured continuously and simultaneously. The initial reference level or baseline for the detector is set by passing oxygen through the cell to remove any remaining atmospheric gases.
Technical Data:
Required Gases:
Carrier gas: Oxygen, 99.5% pure, 40 psi
Pneumatic gas: Compressed air, nitrogen, or argon, 40 psi (2.76 bar), source must be oil- and water-free
Gas flow (based on nominal analysis time):
Measurement: 3 liters per analysis
Pneumatic: 1 liter per analysis
Regulators:
Oxygen: 501-291 O₂ pressure regulator
Compressed air: 766-036 air pressure regulator
Ndjdsxxaxuspfx Afhjd
Inert gas: 764-216 inert gas regulator
Furnace: Induction, 18 MHz, 2.2 kW
Data Transfer: Included
Data Storage:
Without PC: 10 sample weights, 50 results, 5 methods
Without PC: Internal memory / Optional external display
Without PC: LCD display (16 x 26 characters)
Power Requirements:
Determinator: 230 V~, ± 10%, 50/60 Hz, single phase, 15 amp max
Operating current: 12 A
Standby current: 4 A
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in technical data; specifications subject to confirmation!)
For further questions, please feel free to contact us by phone.
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2012
Send inquiry
Telephone & Fax
+49 2861 ... show
These listings may also fit your interest.
Listing
Mainz
6,912 km
Scanning Electron Microscope Zeiss XB350
ZeissXB 350
ZeissXB 350
Listing
Köln
7,003 km
Clean air workbench
HeraguardHPH 15
HeraguardHPH 15
Listing
Germany
8,869 km
Filter Device Osmosis Plant
Thermo Fisher ScientificECO 300
Thermo Fisher ScientificECO 300
Listing
Borken
7,009 km
High-end elemental analyzer
BrukerS8 TIGER WDXRF Spektrometer
BrukerS8 TIGER WDXRF Spektrometer
Listing
Borken
7,009 km
Climatic chamber with humidity, 34 liters
WeissWKL 34/40 -40...+150°C
WeissWKL 34/40 -40...+150°C
Listing
Töltéstava
6,200 km
GC w/ Autosampler, FID, PC & Software
Agilent6890N
Agilent6890N
Listing
Freising
6,651 km
Cross Section Polisher
JEOLIB-19530CP
JEOLIB-19530CP
Listing
Borken
7,009 km
Salt spray chamber corrosion test cabinet
VLMSAL 1000-FL PLC / V.715.362.520
VLMSAL 1000-FL PLC / V.715.362.520
Listing
Borken
7,009 km
System Trace mass spectrometer
Thermo FinniganMS 2160 mit Finnigan DSQ II
Thermo FinniganMS 2160 mit Finnigan DSQ II
Your listing has been deleted successfully
An error has occurred


































































































