Used Climatic Test Chamber for sale (16,210)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
7,009 km
Climate test chamber 11,000 liters (11 m³)
CTSCW-60/11 -60°C bis +90°C
Call
Condition: excellent (used), CTS CW‑60/11 – Water-Cooled Climatic Test Chamber
The CW‑60/6 from CTS GmbH (Climatic Test Systems) is a medium-sized, walk-in or drive-in climatic chamber designed for conducting temperature and humidity tests on multiple test specimens simultaneously.
Device Description:
This climatic test chamber allows you to evaluate the functionality or material properties of your test items under varying temperature and humidity conditions. Efficient air circulation with a high recirculation rate ensures optimal climatic transfer to the test specimens. The air treatment chamber is located at the rear of the interior space. Equipment assemblies are installed in a separate frame behind the unit, providing easy access. The control system is housed in a separate control cabinet, with the operating panel integrated into the cabinet door. For dehumidification, the test chamber features a self-regenerating compressed air dryer. A fan can be used to flush the test chamber with fresh air.
Technical Specifications:
Temperature Tests:
- Temperature range: –60 °C to +90 °C
- Temporal temperature deviation: ±0.5 to 1 K
- Spatial temperature deviation: ±1 K at 200 mm from wall
- Rate of temperature change (supply air, linear):
- Heating: 2 K/min from –40 °C to +85 °C
- Cooling: 2 K/min from +85 °C to –40 °C
Climatic Tests:
- Temperature range: +10 °C to +95 °C
- Humidity range: 10 % to 95 % RH
- Dew point range: +5 °C to +89 °C
- Temporal temperature deviation: ±0.5 K
- Temporal humidity deviation: ±2 – ±5 % RH
- Without heat radiation
- In steady-state conditions
All technical data refer to an ambient temperature of +25 °C, rated voltage of 400 V, without test specimens, no thermal radiation, and without additional equipment.
Dimensions:
Internal (test chamber/usable space):
- Volume: approx. 11,000 liters (11 m³)
- Internal dimensions (approx.): Width: 2100 mm, Depth: 2530 mm, Height: 2200 mm (may vary slightly by configuration)
External dimensions: Width: 2700 mm, Depth: 5200 mm, Height: 2520 mm (depending on door, frame, accessories, etc.)
Operating Data:
Gusdpox Anipsfx Ah Djk
- Rated power: 84.4 kW
- Rated voltage: 400 V 3/N 50 Hz
- Rated current: 131.4 A
Technical Design:
- Refrigeration unit: water-cooled, low noise, semi-hermetic, stepless capacity control via electronic monitoring and control system, eco-friendly refrigerants R 23 / R 404 A
Weight: 6000 kg
Notes:
- Viewing by appointment (46325 Borken)
- Shipping by freight carrier possible; costs & arrangement upon request
- Delivery scope: (see photo)
- (Subject to change and error in technical specifications—information provided without obligation.)
- For further questions, please contact us by phone.
Listing
Żychlin
6,147 km
Binder MKT 240 climatic chamber
BinderMKT 240 E5
Call
Condition: like new (used), Year of construction: 2025, Binder MKT 240 E5 Climate Chamber
Chamber from 2025 with only 66 operating hours.
One-year warranty on spare parts
PRODUCT DESCRIPTION
Temperature range from -70°C to 180°C and realistic simulation capabilities make the MKT series from BINDER truly unique in its class. At the same time, this chamber meets the highest standards for precision and performance in cyclic temperature testing.
KEY FEATURES
Temperature range:
-70°C to 180°C
4 potential-free relay connections
Preheating chamber technology e™
Programmable anti-condensation protection for samples
Heated inspection window with internal LED lighting
BINDER Multi Management Software APT-COM™ Basic Edition
Diagnostic system with visual and acoustic alarm
Intuitive controller with touchscreen, featuring segmental and real-time programming
Internal data logger, measurement values available in an open format readable via USB
Access port with 50 mm silicone plug, located on the left side
Independent, adjustable class 2 (DIN 12880) temperature safety device with visual alarm
Gedpfxjw U Rv Re Ah Deuk
4 casters, two with brakes
Computer connection interface:
Ethernet
Ramp function adjustable
Integrated chart recorder
Real-time clock
Door heating
Stainless steel wire shelf
Stainless steel interior
Halogen-free refrigerants R-452A and R-23
Cooling provided by cascade compressor refrigeration unit
Listing
Borken
7,016 km
Temperature shock test chamber -70-220°C
VötschVT 7012 S2
Call
Year of construction: 2000, operating hours: 1,04,382 h, condition: excellent (used), Vötsch Shock Test Chamber VT 7012 S2
System for extreme temperature cycling
Temperature shock testing is used to test the resistance of components, devices, and other products to rapid changes in ambient temperature.
The test specimens are subjected to rapid temperature changes in air with alternating upper and lower temperature loads.
These cyclical stresses and the accelerated aging caused by temperature changes reveal weaknesses in the test specimen.
Vertical arrangement of the test chambers
Ball screw drive for safe guidance of the car
Cart load capacity 50 kg for VT3 7012 S2
All-around grilles in the car secure the test specimens
High air circulation rate, short temperature change times, and uniform temperature distribution in the test chamber
Hot chamber can be used as a temperature storage unit, cold chamber as a temperature exchange unit
Minimal energy consumption
No compressed air required
Manufacturer: Vötsch
Type: VT 7012 S2
Type: Temperature shock test chamber
Test chamber volume: 120 l
Nominal voltage: 400 V
Nominal power: 10 kW
Nominal current: 25 A
Refrigerant: R452A
Godpfx Aox Exmtjh Douk
Cooling unit: Water-cooled
Shock cooling (nitrogen cooling) via customer-supplied nitrogen
External dimensions
Width: 930 mm
Depth: 2115 mm
Height: 1970 mm
Test chamber dimensions
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Protection class
Device: IP 42
Operating panel: IP 20
Control cabinet: IP 54
Temperature test parameters for single-chamber operation |
Test chamber dimensions
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Protection class ...Temperatur Temperature range
Hot chamber: +50°C to +220°C
Cold chamber: -70°C to +70°C
Temperature deviation over time: ±2 K
in steady state
Temperature deviation over space: ±2 K
in steady state in the car
Heating rate, hot chamber: 11 K/min
Cooling rate, cold chamber: K/min
Heating rate, cold chamber: 2 K/min
Cooling rate, hot chamber: K/min
Observation window: 355 x 355 mm
Pipe opening: 67 mm
Year of manufacture: 2000
Operating hours: 104,382
Weight: 1000 kg
Further items – new and used – can be found in our shop! International shipping costs on request!

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Borken
7,009 km
Climate test chamber 600 liters with humidity
WeissWK3-600/0-M -5°C bis +90°C
Call
Condition: excellent (used), Weiss
Model: WK3 600/0-M
Guodpfex Ag R Sex Ah Dsk
Weiss Climate Test Chamber, Water-Cooled
Series: WK3-../0
with SIMPAC* Controller
Test chamber volume: approx. 600 liters
Test chamber dimensions: Height 950 mm, Width 800 mm, Depth 800 mm
External dimensions: Height 1995 mm, Width 1090 mm, Depth 1660 mm
Operating data:
Test chamber lighting: LED 24 V, 6.8 W / Halogen bulb 2 x 24V, 50W
Rated voltage: 1/N / PE AC 230 V ±10% 50 Hz
Rated power: 2.3 kW
Rated current: 10 A
Site-provided fuse: 16 A slow-blow
Control cabinet and operator panel protection class: IP 54
Maximum heat emission to environment: 1200 W
Sound pressure level:
Measured at a distance of 1m from the front, at a height of 1.6m: 46 dB(A)
Data for temperature tests:
Temperature range: -5°C to +90°C
Temporal temperature deviation at center of usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Temperature gradient (according to IEC 60068-3-5)
Temperature change rate:
Heating 0.6 K/min
Cooling 0.3 K/min
Heat compensation at +20°C to +50°C: 200 W
Data for climatic tests:
Temperature range: +10°C to +90°C
Dew point range: 4 to +89.5°C
Humidity range: 10 to 98 % r.h.
Temporal temperature deviation at center of usable space: ± 0.1 to ± 0.3 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Temporal humidity deviation: +1 to +3 % r.h.
Refrigerant: R-404A
Weight: 610 kg
For your safety as a buyer, please note the following information!
The following points are carried out in advance on our offered chambers:
1. Functionality check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of delivery: (See image)
(Technical data and information subject to change and errors!)
We are happy to answer any further questions you may have by phone.
Listing
Borken
7,009 km
Spray/jet water test chamber
Weiss TechnikSWT 1000 – IPX9K
Call
Condition: excellent (used), Weiss
Type: SWT 1000 – IPX9K
Weiss Spray and Splash Water Test Chamber
Description:
Offered for sale is a WaterEvent SWT 1000 test chamber from Weiss Technik – ideal for standardized testing of enclosure or component water ingress protection (IP) classes.
With optional features, testing according to IPX9K (high-pressure/steam jet), ISO 20653, and additional standards is possible.
High-pressure/steam jet nozzles for IPX9K
Jet nozzles for IPX5/6, among others, compliant with standards:
ISO 20653, DIN EN 60529, SAE J 575, JIS D 0203,
MIL-STD 810, EN 60068-2-18, IEC 60598-1.
Guodpfoxzprcjx Ah Djk
Possible Protection Classes & Tests
Depending on configuration, the SWT system covers a wide range of tests:
Standard configuration: IPX3 / IPX4 tests (spraying and splashing water from all directions).
Optionally: Higher protection classes up to IPX5 / IPX6 (jetting water), and – with corresponding high-pressure configuration – up to IPX9 and IPX9K.
Tests are based on standards such as DIN EN 60529 (for IP protection levels) and ISO 20653 (e.g. for vehicle or outdoor applications) – depending on intended use.
Typical Applications
Typical application scenarios for such a test chamber include:
• Electronic devices or enclosures intended for outdoor use or humid environments, such as outdoor lighting, control housing, assemblies, panels.
• Components for vehicles or machines, especially those exposed to rain, splashing water, or high-pressure cleaning (e.g., construction machinery, e-bike or vehicle parts).
• Batteries or electrical components requiring water ingress protection testing – e.g., automotive industry or e-mobility applications.
Technical Data:
Applicable protection classes: IPX3 / IPX4
Oscillating tube radius (for IPX3/4 tests): standard 200 mm (for SWT 1000), optionally up to 400 mm.
Test chamber (interior):
Internal dimensions: approx. 1,000 × 1,015 × 1,000 mm (W × H × D)
Operation / Control: Web panel or GUI for test programming and control.
Condition: used
Scope of supply: (see photo)
(Data subject to change and correction. Technical specifications may be updated without notice.)
Further questions welcomed by phone.
Discover more used machines
Listing
Borken
7,009 km
Temperature test chamber 480 liters
VötschVTS 7048-10 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Model: VTS 7048-1
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
Performance Data:
With a temperature change rate of 10 K/min
Test chamber internal dimensions: height 950 mm, width 800 mm, depth 650 mm
External dimensions: height 2025 mm, width 1000 mm, depth 2480 mm
Temperature range: -70°C to +180°C
Temporal temperature deviation: ±0.3 to ±0.8
Spatial temperature uniformity: ±0.5 to ±2
Temperature change rate (cooling): 10 K/min
Temperature change rate (heating): 10 K/min
Heat compensation at -20°C: 8,000 W
Heat compensation at +20°C: 8,000 W
Test volume: 480 liters
Left: 1x side port, ∅ 125 mm
Left: 1x side port, ∅ 50 mm
Right: 1x side port, ∅ 125 mm
Chamber is water-cooled
Test chamber illumination:
Halogen bulb: 24 V, 50 W
Electrical connection:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 17 kW
Rated current: 30 A
Gsdjxzgn Iepfx Ah Douk
Refrigerant: R-404A / R-23
Weight: approx. 1,250 kg
Important information for your safety as a buyer!
The following steps are carried out in advance on our offered chambers:
1. Function check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see image)
(Specifications are subject to change and errors excepted!)
For further questions, feel free to contact us by phone.
Listing
Borken
7,009 km
Temperature test chamber 600 liters 5 K/min
VötschVTS 7060-5 -70°C bis + 180°C
Call
Condition: excellent (used), Vötsch
Type: VTS 7060-5
Halogen Bulb 24V, 50W
Vötsch temperature test chamber with color touch panel and S!MPAT
Temperature range: -70°C to +180°C, water-cooled
Temperature deviation over time: ±0.1 to ±0.5 K
Temperature deviation spatially: ±0.5 to ±2.0 K
Temperature change rate cooling: 6 K/min
Temperature change rate heating: 6 K/min
Test chamber dimensions:
Width: 800 mm, Depth: 800 mm, Height: 950 mm
External dimensions:
Width: 1000 mm, Depth: 1750 mm, Height: 2005 mm
Viewing window:
Width: 300 mm x Height: 540 mm
Test chamber volume: 600 liters
Sound level at 1m distance (free-field measurement): < 69 dB(A)
Left side port: 50 mm diameter
Right side port: 2 x 125 mm diameter
Rated voltage: 3/N/PE AC, 400 V ±10%, 50 Hz
Rated power: 16 kW, Rated current: 30 A
Circuit breaker, customer-provided: 29 A slow-blow
Chamber is water-cooled
Refrigerants: R-404A and R 23
Weight approx. 675 kg
For your safety as the buyer, please note the following information!
The following points are completed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legal, compliant refrigerants
3. After successful inspection, the chambers are subjected to a test run monitored with calibrated instruments.
Condition: used
Scope of delivery: (see picture)
Guedpfx Aexw Uqpeh Dsk
(Technical data subject to change and errors excepted!)
We would be happy to answer any further questions by phone.
Listing
Borken
7,009 km
Temperature test chamber 335 liters
VötschVT 4034 -40°C..+180°C
Call
Condition: excellent (used), Vötsch
Type: VT 4034
Vötsch Temperature Cabinet VT 4034 Air-Cooled
Gusdpfxowd Hpae Ah Dek
Refrigerant: Converted to R-452 A
Internal dimensions: Height 750 mm, Depth 765 mm, Width 580 mm
External dimensions: Height 1780 mm, Depth 1595 mm, Width 865 mm
Temperature range: -40°C to +180°C
Temperature deviation:
temporal ± 0.1 to ± 0.5 K
spatial ± 0.5 to ± 2.0 K
Heating 3.2 K/min
Cooling 3.5 K/min
Maximum load (evenly distributed across the surface)
of the test chamber floor: 60 kg
per insert: 30 kg
Total load of the grate supports: 80 kg
Test chamber lighting: 24 V halogen bulb 50W
Rated voltage: 3/N/PE AC 400V ± 10% 50 Hz
Rated power: 4.1 kW
Rated current: 12.5 A
Fuse provided by the customer: 16 A slow-blow
Refrigerant: R-452A
Weight: 490 kg / 335 liters
For your safety, the following information!
The following steps are carried out on our chambers in advance:
1. Functional test and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Temperature test chamber 600 liters
CTST-40/600 -40...180°C
Call
Condition: excellent (used), CTS
Type: T-40/600 /011232
CTS Temperature Test Chamber, Water-Cooled
Includes metal struts to increase the floor load-bearing capacity
Test chamber volume: 600 liters
Test chamber dimensions:
Height approx. 850 mm, width approx. 850 mm, depth approx. 830 mm
External dimensions:
Height approx. 1900 mm, width approx. 1050 mm, depth approx. 1850 mm
Temperature operating range:
Temperature range -40 to +180°C
Temperature deviation ±0.1 to ±0.3 K over time
Heating rate: 2.5 K/min
Cooling rate: 3 K/min
Electrical connection: 400 V +6% -10%, 3/N, 50 Hz
Rated power: approx. 5.5 kW
Rated current: approx. 8.5 A
Refrigerant: R-404A
Weight: 550 kg
For your safety, please note the following information!
The following steps are performed on our chambers in advance:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
Guedpfewfdniex Ah Dek
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Shock test chamber –80 °C to +220 °C
VötschVT 7012 S2
Call
Condition: excellent (used), Vötsch
Model: VT 7012 S2
Shock Test Chamber, Air-cooled
Two-chamber design
Hot Chamber:
The temperature range of the hot chamber extends from +50°C to +220°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 11 K/min
Cold Chamber:
The cold chamber temperature range is from -80°C to +70°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Hot chamber temperature range: +50°C to +220°C
Cold chamber temperature range: -80°C to +70°C
Test chamber dimensions: Width 470 mm, Depth 650 mm, Height 410 mm
Gujdpswxc I Usfx Ah Djk
External dimensions: Width 930 mm, Depth 2115 mm, Height 1970+ mm
Port diameter: ∅ 67 mm
Voltage: 3/N/PE AC 400V +10% 50 Hz
Nominal power: 10 kW
Nominal current: 25 A
Refrigerants: R452-A / R23
Weight: 1,000 kg
Important information for your safety as a buyer!
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical details are subject to change and correction!)
For further questions, please feel free to contact us by phone.
Listing
Borken
7,009 km
Climatic chamber with humidity, 335 liters
VötschVC³ 7034 -70°C bis +180°C
Call
Condition: excellent (used), Type: VC³ 7034
Heraeus Vötsch Climate Test Chamber with Humidity Control (Air-Cooled)
Test Chamber Dimensions: Width 580 mm x Depth 765 mm x Height 750 mm
External Dimensions: Width 780 mm x Depth 1,758 mm x Height 1,800 mm
Specifications for Temperature Testing:
Temperature range: -70°C to +180°C
Temporal deviation: ± 0.1 to ± 0.5 K
Spatial deviation: ± 0.5 to ± 1.5 K
Temperature change rate according to IEC 60068-3-5
Heating: 3.0 K/min
Cooling: 3.0 K/min
Specifications for Climate Testing:
Temperature range: -70°C to +180°C
Temperature deviation in steady-state condition, according to IEC 60068-3-5
(depending on chamber temperature)
Temporal deviation: ± 0.1 to ± 0.3 K
Spatial deviation: ± 0.5 to ± 1 K
Humidity range: 10% to 98% RH
Electrical Connection:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 4.9 kW
Rated current: 16 A
Protection: 16 A slow-blow fuse, provided by customer
Refrigerant: R-404A/R23
Test chamber volume: approx. 335 liters
Net weight: approx. 515 kg
For your safety as a buyer, please note the following information:
The following actions are performed on all chambers we offer prior to sale:
1. Functional check and replacement of necessary components
Godpoxfh Spsfx Ah Djuk
2. If required, refill with legally compliant refrigerant
3. Leak test with certificate
4. Upon successful inspection, chambers undergo a documented test run.
Condition: Used
Scope of delivery: (see picture)
(Subject to modifications and errors in technical data and specifications!)
For further inquiries, please feel free to contact us by phone.
Listing
Borken
7,009 km
Dust test chamber dust chamber
Testzentrum Baden Primus EngineeringDST 1000
Call
Condition: excellent (used), Type: DST 1000
Godpfx Asxpfx Uoh Dsuk
Description:
For sale is a dust test chamber, type DST1000, from Testzentrum Baden GmbH.
This unit was developed for conducting IP protection class “dust” tests (DIN EN 60529 / DIN 40050 Part 9).
Testing possible with or without vacuum.
Operation / Features:
- Control panel with display and buttons
- Manual regulators for individual settings
- Preset test routines for standardized testing
Technical Data:
- Test chamber volume: approx. 1,000 liters
- Internal dimensions (W × D × H): approx. 1,000 × 1,000 × 1,000 mm
- Overall dimensions (W × D × H): approx. 1,300 × 1,000 × 2,000 mm
- Supply voltage: 400 V / 50 Hz, 3~N/PE
- Current consumption: 10 A
- Total electric power: max. 2 kW
- Exhaust connection: DN100 flange
Test Performance / Protection Classes:
- Dust-protected IP5X
- Dust-tight IP6X
Weight: approx. 350 kg
Condition: used
Scope of delivery: (See image)
(Specifications are subject to change and errors excepted!)
We are happy to answer further questions by phone.
Listing
Borken
7,009 km
Temperature test chamber
Heraeus VötschHT 7010 -70°C bis +180°C
Call
Condition: excellent (used), Type: HT 7010
Heraeus Vötsch temperature test cabinet, water-cooled
Temperature deviation in time ± 1 K
Temperature deviation in space ± 2 K
Housing dimensions: Width 820 mm Depth 840 mm Height 1670 mm
Interior: Width 550 mm Depth 350 mm Height 550 mm
Rated voltage: 230V +6/-10% 1/N 50Hz
Rated power: 3.2 kW Rated current: 14.5 A
Temperature range -70°C to + 180°C
2 x side feedthrough 9cm
Guedjhhyz Sspfx Ah Dsk
Weight approx. 260 kg
Refrigerant: R404A and R23
For your safety as a buyer, the following information! The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Temperature test chamber
RS-SimulatorenTS 600/45 EX
Call
Condition: excellent (used), RS Simulators
Here we offer a test cabinet.
Water cooled
Temperature range: -40°C to +180°C
Test chamber dimensions: 850mm x 850mm x 800mm (WxHxD)
Outer dimensions: 1100mm x 1850mm x 1500mm (WxHxD)
current consumption: 13,5 A
Refrigerant: R404A
Connection voltage: 3x400V/N/PE 9A
Weight: approx. 750kg
Type: TS 600/45
Explosion proof operation not tested
but Max 160°C in this
Condition: used / used
Guedsg Urq Ispfx Ah Djk
Scope of delivery: (See picture)
(Changes and errors in technical data, specifications are reserved!)
Further questions we can answer gladly on the phone for you.
Listing
Borken
7,009 km
Climatic chamber
Heraeus VötschVC³ 0100
Call
Condition: excellent (used), Heraeus Vötsch climatic test chamber
Here we offer Heraeus Vötsch climatic test chamber.
Designation VC³ 0100
Test chamber dimensions: H x W x D, approx. 950 x 1100 x 950 mm
TEMPERATURE TESTS:
Minimum temperature -0°C
Maximum temperature +90°C
Temperature change rate cooling 0.2 K/min
Temperature change rate heating 0.5 K/min
Temperature deviation in time ± 0.1 to ± 0.5 K
Temperature homogeneity in space ± 0.5 to ± 1.0 K
Heat compensation at +20 °C 350W
CLIMATIC TESTS:
Minimum temperature +10°C
Maximum temperature +90°C
Dew point temperature range +4°C to +89.5°C
Humidity range 10 to 98% r. h.
Humidity deviation over time ± 1 to ± 3% r. h.
Temperature deviation temporal ± 0.1 to ± 0.3K
Temperature homogeneity in space ± 0.5 to ± 1.0K
Voltage: 1/N/PE AC 230V±10% 50Hz
Rated power: 2.6 kW
Nominal current: 12 A
Refrigerant: R 404A
Weight approx. 1400 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Type: VC³ 0100 / year of construction 2013
Condition: second-hand / used
Godpfon Ard Sox Ah Douk
Scope of delivery: (see picture)
(Subject to changes and errors in the technical data and specifications!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Temperature test chamber 350 liters
CTSTS-70/350 -70°C bis 180°C
Call
Condition: excellent (used), Here we offer you a temperature test cabinet.
Water cooled
Technical performance data:
Temperature working range
Temperature range in °C -70 / +180°C
Rate of change according to DIN 50 011, part 12
Cooling rate: approx. 5 K/min
Heating rate: approx. 5 K/min
Dimensions:
Test volume: 350 liters
Guodpfsn Sl T Sjx Ah Dok
Test chamber dimensions height, approx. 750 mm, width, approx. 650 mm, depth, approx. 720 mm
External dimensions height, approx. 1800 mm, width, approx. 850 mm, depth, approx. 1640 mm
Operating data:
Electrical connection 400 V, 3/N, 50 Hz.
nominal power 13,3 kW
Refrigerant: R404A / R23
Weight: approx. 650 Kg
Type: TS-70/350
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,009 km
Stress test chamber
EspecEHS-221MD
Call
Condition: excellent (used), Espec
Here we offer an Espec (ThermoTec) stress test chamber.
Outer dimensions: W x H x D: 860 x 1795 x 1000 mm
Test chamber dimensions W x H x D: 355 x 355 x 426 mm
2 x 46 l
Voltage 230 V 1/N 50 Hz
Rated current 37A
Fuses 250 V , 2 x 3 A
Type: EHS-221MD
Temperature range: + 105°C to + 142.9°C
Gusdpfxjpdm Uyj Ah Djk
Humidity range 75 to 100 % r.H.
Temperature constancy: -+ 0.5 °C
Pressure range: 0 to 2.0 kg/cm²
Heat-up or pressure build-up time: from 0 to 2.0 kg/cm² in about 60 minutes
390 kg
Condition: Used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,009 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), White temperature shock test chamber
Here we offer a temperature shock test chamber.
Weiss temperature shock test chamber air cooled
( Compressor was renewed ! )
Specification:
Temperature range hot chamber +60°C ... +220°C
Temperature range cold chamber -10°C ... -80°C
Gedpfx Ask E Htysh Deuk
Change hot-/cold chamber 10 s
Temperature constancy ±1 K
Dimensions and further data:
External dimensions: Height 1990 mm
Width ( without and with swivel arm ) without....ca. 1820 mm with....ca. 1915 mm
Depth ( without and with test chamber door ) without....approx. 900 mm with....approx. 1155 mm
Dimensions of the lifting basket ( test chamber ) height 450 mm, width 500 mm, depth 600 mm
volume 130 liters
Test space load max. 20 kg
Test chamber floor load max. 20 kg
Cooling water pressure min. 2 ... max. 6 bar
Max. Backup fuse 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of unit approx. 65 dB(A)
Cooling cascade water cooled
Connected load: 3/N/PE/AC 400V ±10% 50Hz /14,0 kW
nominal current 26,0 A
Refrigerant R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,009 km
Temperature test chamber 335 liters
Vötsch-70°C bis +180°C VTS 7034-5
Call
Condition: excellent (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50 Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
Godpsu H U Twofx Ah Dsuk
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
7,009 km
Climate test chamber with humidity
WeissWK3-340/70 -70°C bis +180°C
Call
Condition: excellent (used), Type: WK3-340/70
Weiss Climate Test Chamber, Water-Cooled
Control Unit: “Touch Panel”
All control and operating commands can be triggered simply by touching the function symbols on the “Touch Panel” control unit.
Adjustable Feet
The test chamber is equipped with adjustable feet to compensate for uneven floors and to ensure sufficient ventilation of the machine section.
Feed-Throughs
The test chamber is fitted with feed-throughs on both the left and right sides. These allow measuring cables and test devices to be routed into the test chamber. Feed-throughs included in the basic configuration:
R1: nominal width 125 mm
L1: nominal width 85 mm
Volume: 335 liters
Test Chamber Internal Dimensions:
Height: 750 mm, Width: 580 mm, Depth: 765 mm
External Dimensions:
Height: 1775 mm, Width: 870 mm, Depth: 1600 mm
Specifications for Temperature Tests:
Minimum temperature: –72°C
Maximum temperature: +180°C
Temperature deviation over time: ± 0.1 to ± 0.5 K
Temperature uniformity spatially: ± 0.5 to ± 1.5 K
Temperature change rate, cooling: 3 K/min
Temperature change rate, heating: 3 K/min
Specifications for Climate Tests:
Temperature range: +10°C to +95°C
Dew point range: –3°C to +94°C
Humidity range: 10 to 98% RH
Temperature deviation over time: ± 0.1 to ± 0.3 K
Temperature uniformity spatially: ± 0.5 to ± 1 K
Humidity deviation over time: ± 1 to ± 3% RH
Operating Data:
Test chamber lighting: Halogen bulb 2 x 24V, 50W
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 16 A
Nominal power: 4.9 kW
Protection: 16 A slow-blow fuse, to be provided onsite
Refrigerant: R-452A/R23
Weight: approx. 585 kg
Gusdpexmg Sdofx Ah Djk
For your security as a buyer, please note the following information!
The following procedures are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Technical data, information and specifications are subject to change and errors.)
If you have any further questions, we will be happy to assist you by phone.
Listing
Borken
7,009 km
Climatic chamber
VötschVCS 7034-5
Call
Condition: used, Vötsch
Model: VCS 7034-5
Climatic Test Chamber, Water-Cooled
Test chamber volume: 335 liters
Specifications for temperature testing:
Temperature range: -70 to +180°C
Temporal temperature deviation: K ±0.1 to ±0.5
Spatial temperature deviation: K ±0.5 to ±2.0
Temperature gradient: 1 to 4 K
Rate of change:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration values: +23°C and +80°C
Specifications for climate testing:
Temperature range: +10 to +95°C
Temporal temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Temporal humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400W
Climate calibration values: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580mm, Depth 765mm, Height 750mm
External dimensions: Width 870mm, Depth 1595mm, Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10%, 50 Hz
Rated power: 10 kW
Gsdpsxqzbbefx Ah Djuk
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerants: R404A / R-23
For your safety as a buyer, please take note of the following information!
The following procedures are carried out in advance on all chambers we offer:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. Upon successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see picture)
(Technical specifications subject to change and error)
If you have further questions, we would be happy to answer them by phone.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
7,009 km
Salt spray chamber corrosion test cabinet
VLMSAL 1000-FL PLC / V.715.362.520
Call
Condition: excellent (used), Type: SAL 1000-FL PLC / V.715.362.520
For sale is a used VLM Salt Spray Corrosion Test Chamber, type SAL 1000-FL PLC, ideal for industrial corrosion tests in accordance with international standards (DIN EN ISO 9227, ASTM B117). Perfectly suited for both laboratory and production environments to test materials, coatings, and components under controlled corrosive conditions.
Features:
- Robust stainless steel frame construction, max. load 450 kg
- Precise control and reproducible testing
- Versatile applications for salt spray, condensation water, and ventilation testing
Technical details:
- Exterior: Stainless steel 1.4301, powder-coated (special version)
- Test chamber: Stainless steel, ECTFE-coated
- Max. chamber temperature: +80 °C
- Temperature stability: ±0.3 °K, temporally ±0.1 °C
- Process control: PLC with touchscreen, LED display
- Interface: Ethernet
- Water quality: demineralized, max. conductivity 20 µS/cm
- Humidifier water consumption: approx. 0.5 l/h (depending on program)
- Water connection pressure: 2–4 bar
- Compressed air consumption: approx. 20 m³/h
- Compressed air connection: 6–8 bar
- External dimensions (W x D x H): 2160 x 670 x 1090 mm
incl. base cabinet: 2160 x 670 x 1890 mm
- Internal chamber dimensions (W x D x H) / volume: 1400 x 605 x 920 mm / 1040 l
- Max. load sample rod: 40 kg
Godpfx Ahsxnyqvs Djuk
- Electrical connection: 400 V / 50 Hz / 4000 W
- Weight (empty): 350 kg
Condition: used
Scope of delivery: (see image)
(Subject to changes and errors in technical data and specifications!)
For further questions, we are happy to assist you by phone.
Listing
Borken
7,009 km
Temperature test chamber 335 liters
Vötsch-70°C bis +180°C VTS 7034-5
Call
Condition: excellent (used), Type: VCS 7034-5
Climate Test Chamber Water-Cooled
Test chamber volume: 335 liters
Performance for temperature tests:
Temperature range: -70 to +180°C
Temperature deviation over time: ±0.1 to ±0.5 K
Temperature deviation spatially: ±0.5 to ±2.0 K
Gujdpfx Ahjxufypo Dek
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 3.5 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3,000 W / at -20°C: 3,000 W
Temperature calibration points: +23°C and +80°C
Performance for climate tests:
Temperature range: +10 to +95°C
Temperature deviation over time: ±0.1 to ±0.3 K
Temperature deviation spatially: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Humidity deviation over time: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climatic calibration points: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions:
Width: 580 mm, Depth: 765 mm, Height: 750 mm
External dimensions:
Width: 870 mm, Depth: 1595 mm, Height: 1775 mm
Feedthroughs:
1 x approx. 50 mm Ø, left side
2 x approx. 125 mm Ø, left side
1 x approx. 125 mm Ø, right side
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerant: R404A / R-23
For your security as a buyer, please note the following information:
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical data are subject to change and errors!)
If you have further questions, we are happy to answer them by phone.
Listing
Borken
7,009 km
Climatic chamber
EspecEGNX12-6CWL
Call
Condition: good (used), Espec
Type: EGNX12-6CWL
Espec temperature and climate test chamber air-cooled
Temperature (and humidity) test chamber N series
Power supply:
AC 400/460 V 3-phase 50/60Hz 32A
Temperature range -70 to +180°C
Humidity range 10 to 95% r. H.
Temperature change rate
Heating 15 °K/min
Gusdpfx Ahot Nf Upo Djk
Cooling 11 °K/min
Internal dimensions W x H x D in mm 600 x 750 x 850
External dimensions W x H x D in mm 889 x 2098 x 1768
Useful volume 380 l
Refrigerant R404A
Weight: 370 kg
The following information is for your safety as a buyer!
The following points are carried out on our chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Gjdpfxjun Izcs Ah Dsuk
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
We make it easier for you to find: "climatic test chamber"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Climatic Test Chamber (16,210)
Search Machineseeker now with more than 2,00,000 used machines:Browse through the most popular machine descriptions:
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month