Used Climatic Test Chamber for sale (14,249)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
7,009 km
Climate chamber
DycometalCCK -40/1500 T 1500 Liter
Call
Year of construction: 2022, condition: excellent (used), Dycometal
Type: CCK -40/1500T
Climate chamber water-cooled
Volume liters 1500
Internal dimensions height 1000 mm width 1000 mmm depth 1500 mm
Bsdou N Uugspfx Apajwn
External dimensions Height 2200 mm Width 1293 mmm Depth 3400 mm
Thermal test
Minimum temperature -40°C
Maximum temperature +150°C
Thermal gradient cooling 2.0 K/min.
Thermal gradient during heating 3.5 K/min.
Temperature stability ±0.1°C to ±0.3°C
Temperature uniformity ±0.5°C to 1.5°C
Climate test Temperature range +10°C to +90°C
Humidity range 10% to 98% %RH
Dew point range +6.5°C to +86°C
Humidity stability ±1%RH to ±3%RH
Water-cooled condenser
Nominal voltage 400 V 3N~PE 50 Hz
Output 16.1 kW 27.5 A
Refrigerant R-452A
Weight: 1120 kg
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Shock test chamber
HeraeusHT 7012 S2
Call
Condition: excellent (used), Here we offer shock test chamber.
Temperature shock test chamber water cooled
Two-chamber design
Warm chamber:
Temperature control of the warm chamber ranges from +50°C to +220°C
Temperature deviation temporally in useful chamber center ± 1 K
Temperature deviation spatially ± 2 K
Temperature change rate
heating 11 K/min
cold chamber:
the cold chamber from -65°C to +70°C
Temperature deviation temporally in useful space center ± 1 K
temperature deviation spatially ± 2 K
Temperature change rate
heating 2 K/min
cooling 3 K/min
Test chamber volume 125 liters
Temperature range hot chamber +50°C to +220°C
Temperature range cold chamber -80°C to +70°C
Bodpfx Apoi Az Egsaown
Test chamber dimensions width 470mm depth 650mm height 410mm
Outer dimensions width 930mm depth 2115mm height 1970+mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant R404A / R23
Operating hours: 27.903 hrs.
Weight: 1000 kg
For you as a buyer, the following information for your safety!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: HT 7012 S2
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,009 km
Climate chamber
CTSCW-40/16
Call
Condition: excellent (used), CTS climate chamber climate test cell
Here we offer a CTS climate chamber climate test cell.
Available from mid-January 2023!
Water cooled
Height adjustable!
Footprint approx. (W x D x H): 3755x 3470x 2480
Test area approx. (W x D x H): 2500x 2720x 2200
Test space volume: approx. 15m³
Temperature range: -40°C to +140°C
Temperature deviation 1 K temporally
Temperature change speed in the average without heat radiation Measured in the supply air
heating: 2 K/min
Cooling: 1 K/min
from +110°C to -35°C
Climatic tests:
Temperature range: +10 °C to +90 °C
Humidity range . +30 % to +95% r.H.
dew point range : +5°C to 89°C
Bwjdpoip Dp Sefx Apajn
temperature deviation 0,5 K temporal
Humidity deviation ±1- ±3% r.H. temporal
nominal voltage: 400V 3/N, PE, 50 Hz
rated power: 53,5 KW
Rated current: 92,3 A
Compressor: S6J-16.2
+ chiller
Refrigerant: R404A
Weight 5500 kg
Type: CW-40/16
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Borken
7,009 km
Temperature test chamber 335 liters
VötschVTS 7034-5 -70°C bis +180°C
Call
Condition: excellent (used), Heraeus Vötsch temperature test chamber
Here we offer you a Heraeus Vötsch temperature test chamber.
Heraeus Vötsch temperature test chamber water cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6,5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
Outer dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free field measurement) < 69dB (A)
side entry 5,5 cm / 12,5 cm
cabinet is water cooled
Refrigerant: R 452A and R 23
weight approx. 570 kg
Bjdpoir D U Djfx Apaown
Type: VTS 7034-5
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,009 km
Temperature test chamber 600 liters
CTST-70/600/S 70°C bis 180°C
Call
Condition: good (used), CTS
Type: T-70/600/S
Temperature test chamber water-cooled
Refrigerant: Converted to R-452A
Control:
- 32 bit controller
- LCD control panel
- Digital display of setpoints and actual values
- Numerical input of setpoints
- Error messages in plain text
- RS 232 interface
- Free switching channels for on-site test material control
Technical performance data
Temperature tests:
Temperature range -70 °C to +180 °C
Temperature deviation ±0.1 to ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Bwjdpfx Aevitmdopasn
Heat radiation
approx. 2500 W at +20°C
approx. 2500 W at + 0°C
approx. 1800 W at -40°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions Height, approx. 850 mm, width, approx. 850 mm, depth, approx. 830 mm
External dimensions Height, approx. 1900 mm, width, approx. 1120 mm, depth, approx. 1875 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 8.8 kW
Nominal current 14.8 A
Protection class IP 22
Weight approx. 700 kg
Refrigerant: R-452A / R23
Weight: 700 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Temperature test chamber 600 liters
CTST-70/600/S -70°C bis 180°C
Call
Condition: excellent (used), CTS
Type: T-70/600/S
Water-cooled temperature test chamber
Control system:
- 32 bit controller
- LCD control panel
- Digital display of set and actual values
- Numerical input of setpoints
- Error messages in plain text
- RS 232 interface
- Free switching channels for on-site test material control
Technical performance data
Temperature tests:
Temperature range -70 °C to +180 °C
Temperature deviation ±0.1 to ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat radiation
approx. 2500 W at +20°C
approx. 2500 W at + 0°C
approx. 1800 W at -40°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions Height, approx. 850 mm, width, approx. 850 mm, depth, approx. 830 mm
External dimensions Height, approx. 1900 mm, width, approx. 1120 mm, depth, approx. 1875 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 8.8 kW
Nominal current 14.8 A
Protection class IP 22
Weight approx. 700 kg
Refrigerant: R404A / R23
Weight: 600 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
Bwedpfx Aju U Ixmepajn
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Temperature test chamber -70°C to +180°C
VötschVTS 7018-5 190 Liter
Call
Condition: excellent (used), Vötsch
Model: VTS 7018-5
Water-cooled Temperature Test Chamber
System retrofitted with R-452A
Temperature range: -70°C to +180°C
Temporal temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature change rate cooling: 7.5 K/min
Temperature change rate heating: 7.5 K/min
Heat compensation at +20°C: 3000 W
Heat compensation at -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 450 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1280 mm, Height 1575 mm
Test chamber volume: 190 liters
Rated voltage: 3/N/PE AC, 400V ±10%, 50Hz
Rated power: 10.0 kW, Rated current: 21 A
Main fuse (on-site): 32 A slow-blow
Sound level at 1m distance (free-field measurement): < 69dB (A)
Side port: 50 mm / 125 mm
Chamber is water-cooled
Refrigerants: R-452A and R 23
Weight approx. 460 kg
For your safety as a buyer, the following information:
Bwsdpfx Aewq Iymjpasn
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, new charging with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (See picture)
(Technical data may be subject to change or error!)
If you have any further questions, we will be happy to answer them by phone.
Listing
Borken
7,009 km
Temperature shock test chamber
EspecTSD-100
Call
Condition: good (used), Espec
Type: TSD-100
100 liters of usable space for larger test specimens up to 30 kg.
Complies with all current international standards.
Water-cooled
Temperature range hot chamber: +60 °C to +200 °C
Temperature range cold chamber: 0 °C to -70 °C
Bwjdpjugl H Sjfx Apajn
Test chamber dimensions: 710 x 345 x 410 (W x H x D) in mm
External dimensions: 1100 x 1885 x 1965 (W x H x D) in mm
Water-cooled refrigeration unit
Program control via touch panel
Automatic defrosting
Overtemperature protection
Operating hours counter
Mobile version
2 stainless steel test baskets
Cable gland Ø 100 mm
Refrigerant: R404A 1kg R23
Power supply: 400V 3Ph 50Hz
Max. Current consumption: 32A
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Shock test chamber -80°C to +220°C
VötschVT 7012 S2
Call
Condition: excellent (used), Here we offer Vötsch shock test chamber.
Temperature shock test chamber water cooled
Two-chamber design
Warm chamber:
The temperature control of the warm chamber ranges from +50°C to +220°C
Temperature deviation in time in the center of the chamber ± 1 K
Temperature deviation spatially ± 2 K
Temperature change rate
heating 11 K/min
cold chamber:
the cold chamber from -80°C to +70°C
Temperature deviation temporally in useful space center ± 1 K
temperature deviation spatially ± 2 K
Temperature change rate
heating 2 K/min
cooling 3 K/min
Test chamber volume 125 liters
Temperature range hot chamber +50°C to +220°C
Temperature range cold chamber -80°C to +70°C
Test chamber dimensions width 470mm depth 650mm height 410mm
Outer dimensions width 930mm depth 2115mm height 1970+mm
Feedthrough ∅ 67mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant R404A / R23
Weight: 1000 kg
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: VT 7012 S2
Condition: used / used
Scope of delivery: (See picture)
Bjdpfx Aoigg Hnjpajwn
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,009 km
Temperature test chamber -70°C to +180°C
VötschVT 7021
Call
Condition: excellent (used), Heraeus Vötsch
Type: VT 7021
Air-cooled temperature test chamber
1 port, nominal width 80 mm,
Test chamber volume: 210 liters
Temperature range: -70°C to +180°C
Temporal temperature deviation: ± 0.2 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (heating): 2.5 K/min
Temperature change rate (cooling): 2.5 K/min
Max. heat compensation: 800 W
Test chamber dimensions: Width 560 mm, Depth 570 mm, Height 630 mm
External dimensions: Width 850 mm, Depth 1250 mm, Height 1640 mm
Electrical connection: 1/NPE AC 230 V ± 10% 50 Hz
Rated power approx. 1.8 kW, rated current 12 A
Refrigerant: R404A and R23
Weight: 355 kg
For your safety as a buyer, please note the following information!
Bwjdpfx Apjwylv Djasn
The following procedures are performed on the chambers we offer, in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Subject to technical modifications and errors in the details!)
For further questions, please feel free to contact us by phone.
Listing
Borken
7,009 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), White temperature shock test chamber
Here we offer a temperature shock test chamber.
Weiss Temperature Shock Test Cabinet Water Cooled
Specification:
Temperature range hot chamber +60°C ... +220°C
Temperature range cold chamber -10°C ... -80°C
Change hot/cold chamber 10 s
Temperature constancy ±1 K
Dimensions and other data:
External dimensions: Height 1990 mm
Width ( without and with door hinge ) without....approx. 1820 mm with....approx. 1850 mm
Depth ( without and with test room door ) without....ca. 900 mm with....ca. 1155 mm
Dimensions of the lifting basket ( test chamber ) height 450 mm, width 500 mm, depth 600 mm
volume 130 liters
Test space load max. 20 kg
Test chamber floor load max. 20 kg
Cooling water pressure min. 2 ... max. 6 bar
Max. Backup fuse 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of unit approx. 65 dB(A)
Cooling cascade water cooled
Connected load: 3/N/PE/AC 400V ±10% 50Hz /18.7 kW
nominal current 26,0 A
Refrigerant R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Bwedslmkn Tjpfx Apaen
Listing
Borken
7,009 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), White temperature shock test chamber
Here we offer a temperature shock test chamber.
Weiss Temperature Shock Test Cabinet Water Cooled
Specification:
Temperature range hot chamber +60°C ... +220°C
Temperature range cold chamber -10°C ... -80°C
Change hot/cold chamber 10 sec.
Temperature constancy ±1 K
Dimensions and further data:
External dimensions: Height 1990 mm
Width ( without and with door hinge ) without....approx. 1820 mm with....approx. 1850 mm
Depth ( without and with test room door ) without....ca. 900 mm with....ca. 1155 mm
Dimensions of the lifting basket ( test chamber ) height 450 mm, width 500 mm, depth 600 mm
volume 130 liters
Test space load max. 20 kg
Test chamber floor load max. 20 kg
Bwedpom Ak H Hefx Apasn
Cooling water pressure min. 2 ... max. 6 bar
Max. Backup fuse 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of unit approx. 65 dB(A)
Cooling cascade water cooled
Connected load: 3/N/PE/AC 400V ±10% 50Hz /14,0 kW
nominal current 26,0 A
Refrigerant R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,009 km
Temperature shock test chamber
WeissTS 130
Call
Condition: used, White
Type: TS 130
Temperature shock test chamber water-cooled
Specification:
Temperature range hot chamber +60°C … +220°C
Temperature range cold chamber -10°C … -80°C
Switch between hot and cold chambers 10 sec.
Temperature stability ±1 K
Dimensions and other data:
External dimensions: Height 1990 mm
Width (without and with door hinge) without....approx. 1820 mm with....approx. 1850 mm
Depth (without and with test chamber door) without....approx. 900 mm with....approx. 1155 mm
Dimensions of the lifting basket (test room) height 450 mm, width 500 mm, depth 600 mm
Volume 130 liters
Test room load max. 20 kg
Test room floor load max. 20 kg
Cooling water pressure min. 2 ... max. 6 bar
Max. fuse 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of the device approx. 65 dB(A)
Water-cooled cooling cascade
Connection values: 3/N/PE/AC 400V ±10% 50Hz /14.0 kW
Rated current 26.0 A
Refrigerant R 404A / R23
Weight: approx. 950 kg
Condition: used
Scope of delivery: (See picture)
Bwedpfsvwckhsx Apaen
(Changes and errors in the technical data, information is subject to change!)
More We will be happy to answer any questions you may have over the phone.
Listing
Borken
7,009 km
Temperature test chamber 1000 liters
CTS - 70°C bis +180°CTS -70/1000-10 bis ca.10 K/min
Call
Condition: good (used), Type: TS -70/1000-10
For sale is a CTS temperature test chamber
Model: TS -70/1000-10
Cooling: water-cooled refrigeration unit
Compressor has been replaced!
Features:
- Multi-touch control system
- USB and Ethernet interfaces
- Cable feedthroughs for test cables: 4 × Ø 125 mm
- Safety temperature limiter
Applications:
- Environmental and longevity tests
- Thermal cycling tests (stress screening)
- Quality assurance and research & development
- Electronics, automotive, materials testing
Test chamber volume: 1,000 liters
Test chamber dimensions:
- Height: approx. 1,000 mm
- Width: approx. 860 mm
- Depth: approx. 1,100 mm
External dimensions:
- Height: approx. 1,950 mm
- Width: approx. 1,270 mm
- Depth: approx. 1,900 mm
Temperature range: -70°C to +180°C
Temperature deviation: ± 0.3 K over time
Temperature change rate: up to approx. 10 K/min
Electrical connection: 400V 3/N 50Hz
Rated power: approx. 23.1 kW
Rated current: approx. 40 A
Refrigerant: R404A / R23
Weight: 1,000 kg
For your peace of mind as a buyer, please note:
The following inspections and services are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant if required
3. Leak test with certificate
4. Following successful checks, chambers undergo a documented test run
Condition: used
Scope of delivery: (See pictures)
(Specifications and technical data subject to change and errors excepted!)
Bwsdpfx Ajxdi Ezopajn
We are happy to answer further questions by phone.
Listing
Borken
7,009 km
Temperature test chamber
CTSTS -70/600-13
Call
Condition: used, CTS
Type: TS -70/600-13
Temperature test chamber, water-cooled
Type series: TS -70/600-13
Control system:
- 32 bit controller
- LCD control panel
- Digital display of setpoints and actual values
- Numerical input of setpoint values
- Error messages in plain text
- RS 232 interface
- Free switching channels for on-site test material control
Test chamber volume: 600 liters
Test chamber dimensions: Height approx. 730 mm, width approx. 850 mm, depth approx. 830 mm
External dimensions: Height approx. 2250 mm, width approx. 1300 mm, depth approx. 2475 mm
Temperature range: -70 to +180°C
Heating speed: 13 K/min at -40°C to +120°C
Cooling speed: 13 K/min at 120°C to -40°C
Temperature deviation: ± 0.1K temporal, ± 0.5 K spatial
Electrical connection 400/3P/N/PE
Nominal power: approx. 27.8 kW
Nominal current: approx. 44.1 A
Compressor: 4TC-8.2Y/4PC-10.2Y
Refrigerant: R-404 A / R-23
Weight: 1350 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
Bedpfx Apovcyaweaewn
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Temperature test chamber 680 liters
Heraeus VötschVLM 3068/S -30 °C bis +125 °C
Call
Year of construction: 2010, condition: excellent (used), Here we offer you a Heraeus Vötsch temperature test chamber.
Vötsch temperature test chamber VLM 3068/S air-cooled
(building material test chambers loaded from above)
Control panel
The control panel is mounted on a console on the temperature test chamber. By
control and operating commands can be triggered by simply touching the function symbols.
can be triggered. The operating instructions for the control panel are enclosed
Main switch
The main switch is located at the front of the temperature test chamber.
Air treatment room
The air treatment room is located in the test room
and contains the components required for temperature control.
In the air treatment room, the air is tempered (cooling/heating) and circulated by the test room fan.
circulated by the test room fan. The air is sucked in at the center of the side wall and
enters the test chamber again via the air baffles on the long sides.
Feed-throughs
The temperature test chamber can optionally be equipped with feed-throughs. Through these
can be used to route cables and test equipment into the test chamber.
Entry port front 2 x 82 mm ∅ rear 1 x 85 mm ∅
Internal dimensions Width 2000 mm Depth 570 mm Height 600 mm
External dimensions Width 3000 mm Depth 870 mm Height 1060 mm
Technical data:
Data for mechanical load:
Max. load with test material
Test area floor
(evenly distributed over the surface) 600 kg
Point load 50 kg
Data for temperature tests:
Temperature range -30 °C to +125 °C
Temperature deviation over time in the center of the usable space ±1 K
Bodpfx Aorbiyfjpaswn
Temperature change rate
Heating approx. 1 K/min
Cooling approx. 2 K/min
Data for operation:
Nominal voltage 3/N / PE AC 400 V ±10% 50 Hz
Rated power 3 kW Rated current 9 A
Customer fuse 16A slow-blow
Temperature test chamber VLM 3068/S
Test chamber volume approx. 680 l
Weight approx. 700 kg
Refrigerant: R-404A
Noise measurement Sound pressure level approx. 68 dB(A)
Type: VLM 3068/S
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,009 km
Temperature test chamber ex protected
CTST-30/950 Ex/I
Call
Year of construction: 2011, condition: excellent (used), CTS
Type: T-30/950 Ex/I
CTS Temperature Test Chamber, Explosion-Proof
Control – 32-bit controller
LCD control panel
Digital display for set and actual values
Numerical input of set values
Error messages in plain text
RS 232 interface
Free switching channels for product-side test specimen activation
Temperature Testing:
Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
Heating: 2 K/min
Cooling: 1.5 K/min down to -10°C
Thermal radiation: approx. 1000 W at +20°C
approx. 200 W at -25°C
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with a large flow rate of N2 until the
o2 content drops below 3%. Then, it switches to a base flow amount (approx. 10% of the large flow rate).
The nitrogen flow for the base amount is measured and displayed using a flowmeter and monitored via a limit switch.
O2 monitoring continuously extracts gas from the test chamber via a flame arrestor and passes it over an O2 sensor which checks the residual oxygen content of the extracted air.
Afterwards, the gas is returned to the test chamber via a second flame arrestor.
The extraction pump is monitored by a volumetric flow meter. Additional details can be found in the Dräger user manual in the appendix.
The gas system is currently deactivated!
All technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without irradiation, and without additional equipment.
Dimensions:
Test chamber volume: 950 liters
Test chamber dimensions: Height approx. 700 mm / Width approx. 900 mm / Depth approx. 1500 mm
External dimensions: Height approx. 2400 mm / Width approx. 1270 mm / Depth approx. 3125 mm
Operating data:
Electrical connection: 400V +6/-10 %, 3/N, 50 Hz
Nominal power: 21.6 kW
Rated current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, R 1/2" inner thread
Sound pressure level:
Bjdpfx Aeihb Amjpaown
Listing
Borken
7,009 km
Temperature shock test chamber 60 liters
WeissTS 60 -72…+220 °C
Call
Condition: excellent (used), Weiss Technik TS 60 Thermal Shock Test Chamber / 60 L, –71…+220 °C
Water-cooled
Item description:
For sale is a Weiss Technik TS 60 Thermal Shock Test Chamber.
Bedpfx Ajxr A R Topaewn
The chamber is ideally suited for rapid temperature cycling tests (e.g., per IEC, MIL-STD, JEDEC) and has been well maintained.
Volume & internal dimensions:
Test volume: 60 liters
Internal basket/test room dimensions (W × D × H): approx. 380 × 430 × 370 mm
External dimensions (W × D × H): 895 × 1970 × 1895 mm
Temperature ranges & cycling:
Hot chamber: +50 °C to +220 °C
Cold chamber: –72 °C to +70 °C
Transfer time (basket between both zones): < 10 seconds
Heating rate / speed up to 17 °C/min
Cooling rate / speed up to 3.7 °C/min
In single mode (cold zone only), heating rate: approx. 3.2 °C/min
Temperature deviation & uniformity:
Temporal deviation (temperature control over time): ± 0.3 to ± 1.0 °C
Load / permissible weight & lifting system:
Basket/lifting system load capacity: 20 kg maximum load
Transfer basket secured by safety grilles on all sides
Additional features & equipment:
Noise level: approx. 58 dB(A) in operation
Control: Touchscreen, RS-232 / USB / Ethernet interfaces
Electrical connection:
3/N/PE AC 400 V ±10% 50 Hz
Rated power: approx. 8.5 kW
Rated current: approx. 25 A
On-site protection: 32 A
Refrigerants: R-404A / R-23
Weight: 800 kg
Important safety information for buyers!
The following steps are carried out on our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and errors reserved!)
For further questions, feel free to contact us by phone.
Listing
Borken
7,009 km
Shock test chamber –75°C to +220°C
VötschVT 7012 S2
Call
Condition: excellent (used), Vötsch
Model: VT 7012 S2
Water-cooled
Two-chamber configuration
Hot chamber:
Temperature range of hot chamber: +50°C to +220°C
Temporal temperature deviation at the center of useful space: ±1 K
Spatial temperature deviation: ±2 K
Temperature change rate:
Heating: 11 K/min
Cold chamber:
Temperature range of cold chamber: -74.5°C to +70°C
Temporal temperature deviation at the center of useful space: ±1 K
Spatial temperature deviation: ±2 K
Temperature change rate:
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Temperature range hot chamber: +50°C to +220°C
Bwjdjx Hhfhopfx Apaen
Temperature range cold chamber: -80°C to +70°C
Test chamber dimensions: width 470 mm, depth 650 mm, height 410 mm
External dimensions: width 930 mm, depth 2115 mm, height 1970+ mm
Port diameter: 67 mm
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Rated power: 10 kW
Rated current: 25 A
Refrigerants: R-452A / R-23
Weight: 1000 kg
Important safety information for buyers:
The following actions are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Recharging with legally compliant refrigerant
3. Leak test with certificate
4. After a successful check, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Subject to changes and errors in technical data and specifications!)
We are happy to answer further questions by phone.
Listing
Borken
7,009 km
Spray/jet water test chamber
Weiss TechnikSWT 1000 – IPX9K
Call
Condition: excellent (used), Weiss
Type: SWT 1000 – IPX9K
Weiss Spray and Splash Water Test Chamber
Description:
Offered for sale is a WaterEvent SWT 1000 test chamber from Weiss Technik – ideal for standardized testing of enclosure or component water ingress protection (IP) classes.
With optional features, testing according to IPX9K (high-pressure/steam jet), ISO 20653, and additional standards is possible.
Bwsdpfsxzprcox Apajn
High-pressure/steam jet nozzles for IPX9K
Jet nozzles for IPX5/6, among others, compliant with standards:
ISO 20653, DIN EN 60529, SAE J 575, JIS D 0203,
MIL-STD 810, EN 60068-2-18, IEC 60598-1.
Possible Protection Classes & Tests
Depending on configuration, the SWT system covers a wide range of tests:
Standard configuration: IPX3 / IPX4 tests (spraying and splashing water from all directions).
Optionally: Higher protection classes up to IPX5 / IPX6 (jetting water), and – with corresponding high-pressure configuration – up to IPX9 and IPX9K.
Tests are based on standards such as DIN EN 60529 (for IP protection levels) and ISO 20653 (e.g. for vehicle or outdoor applications) – depending on intended use.
Typical Applications
Typical application scenarios for such a test chamber include:
• Electronic devices or enclosures intended for outdoor use or humid environments, such as outdoor lighting, control housing, assemblies, panels.
• Components for vehicles or machines, especially those exposed to rain, splashing water, or high-pressure cleaning (e.g., construction machinery, e-bike or vehicle parts).
• Batteries or electrical components requiring water ingress protection testing – e.g., automotive industry or e-mobility applications.
Technical Data:
Applicable protection classes: IPX3 / IPX4
Oscillating tube radius (for IPX3/4 tests): standard 200 mm (for SWT 1000), optionally up to 400 mm.
Test chamber (interior):
Internal dimensions: approx. 1,000 × 1,015 × 1,000 mm (W × H × D)
Operation / Control: Web panel or GUI for test programming and control.
Condition: used
Scope of supply: (see photo)
(Data subject to change and correction. Technical specifications may be updated without notice.)
Further questions welcomed by phone.
Listing
Germany
6,760 km
Climate Chamber
Wolf StahlbauWLE-B-K 90/140
Call
Year of construction: 1995, condition: ready for operation (used), Two walk-in climate chambers including Wolf burner are available. Heating capacity: 105kW, heating medium: oil/gas, max. oil throughput: 14.9kg/h, air volume flow: 2.78m³/h, max. external delivery pressure: 400Pa, control: PLC. Documentation available. An on-site inspection is possible.
Bsdpfx Ajyit Hbopaown
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
7,016 km
Temperature test chamber
VötschVTR 7033/S
Call
Condition: good (used), Year of construction: 1996, Vötsch VTR 7033/S Temperature test chamber
Manufacturer: Vötsch
Type: VTR 7033/S
Item no.: 60885637
Temperature chamber
Temp. range: -70°C to +180°C
Mains voltage:400V
Rated current:24A
Rated output: 9.5 kW
Refrigerant VK: R 404 A
Refrigerant TK: R 23
Year of manufacture: 1996
TK 07
Financing through our bank is also possible.
komplett-konzept.leasingo.de
You will find further articles - new and used - in our store!
Bedewbpzmepfx Apaewn
International shipping costs on request!
Listing
Borken
7,016 km
Temperature shock test chamber
VötschVT 7030 S2
Call
Condition: good (used), Year of construction: 1998, Vötsch VT 7030 S2 Temperature Shock Test Chamber -80 °C to +220 °C
The Vötsch VT 7030 S2 Environmental Test Chamber is designed for laboratory applications that require testing of materials and components in a known environment. With its versatile capabilities and easy-to-use controls, this programmable unit can be used to simulate a variety of environmental conditions for scientific studies, product testing and process control.
Data for temperature tests in single chamber operation
Hot chamber:
Temperature shock test chamber Test chamber 300 l
Temperature range +50 °C to +220 °C
Temperature deviation in time in the center of the chamber ± 1 K
Temperature deviation in space ± 2 K
Temperature gradient (according to IEC 60068-3-5) 4 K
Rate of temperature change (according to IEC 60068-3-5, measured in supply air)
Heating 11 K/min
Cold chamber:
Temperature shock test chamber Test chamber 300 l
Temperature range -80 °C to +70 °C
Temperature deviation in time in the middle of the usable space ± 1 K
Bwedpfx Apowbdv Seasn
Temperature deviation in space 2 K
Temperature gradient (according to IEC 60068-3-5) 4 K
Rate of temperature change (according to IEC 60068-3-5, measured in supply air)
Heating 1.5 K/min
Cooling 4K/min
Technical data:
Temperature shock test chamber
Test chamber volume approx. 300 l
Voltage: 3/N/PE AC 400 V ± 10 % , 50 Hz
Rated power: 30 kW
Rated power: 50 A
Refrigerant: R-404a /R-23
Chiller: Water-cooled
Weight: approx. 940 kg
Year of construction. 1998
Test room dimensions: Width 770 mm x depth 650 mm x height 610 mm
Housing dimensions: Width 1200 mm x depth 1800 mm x height 2050 mm
TS 05
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Further items - new and used - can be found in our store!
International shipping costs on request!
Listing
Borken
7,016 km
Temperature test chamber
VötschVT 7100
Call
Condition: excellent (used), Heraeus Vötsch VT 7100 Temperature test chamber -70°C to +180°C
Bwodpsph Uzxofx Apajn
Heraeus Vötsch
Temperature test chamber
VT 7100
-70°C to +180°C
1035 liters
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Further articles - new and used - you will find in our store!
International shipping costs on request!
Listing
Borken
7,016 km
Temperature shock test chamber -70-220°C
VötschVT 7012 S2
Call
Year of construction: 2000, operating hours: 1,04,382 h, condition: excellent (used), Vötsch Shock Test Chamber VT 7012 S2
System for extreme temperature cycling
Temperature shock testing is used to test the resistance of components, devices, and other products to rapid changes in ambient temperature.
The test specimens are subjected to rapid temperature changes in air with alternating upper and lower temperature loads.
These cyclical stresses and the accelerated aging caused by temperature changes reveal weaknesses in the test specimen.
Vertical arrangement of the test chambers
Ball screw drive for safe guidance of the car
Cart load capacity 50 kg for VT3 7012 S2
All-around grilles in the car secure the test specimens
High air circulation rate, short temperature change times, and uniform temperature distribution in the test chamber
Hot chamber can be used as a temperature storage unit, cold chamber as a temperature exchange unit
Minimal energy consumption
No compressed air required
Manufacturer: Vötsch
Type: VT 7012 S2
Type: Temperature shock test chamber
Test chamber volume: 120 l
Nominal voltage: 400 V
Nominal power: 10 kW
Nominal current: 25 A
Refrigerant: R452A
Cooling unit: Water-cooled
Shock cooling (nitrogen cooling) via customer-supplied nitrogen
External dimensions
Width: 930 mm
Depth: 2115 mm
Height: 1970 mm
Test chamber dimensions
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Protection class
Device: IP 42
Operating panel: IP 20
Control cabinet: IP 54
Bwjdpfx Aex Exmtspajn
Temperature test parameters for single-chamber operation |
Test chamber dimensions
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Protection class ...Temperatur Temperature range
Hot chamber: +50°C to +220°C
Cold chamber: -70°C to +70°C
Temperature deviation over time: ±2 K
in steady state
Temperature deviation over space: ±2 K
in steady state in the car
Heating rate, hot chamber: 11 K/min
Cooling rate, cold chamber: K/min
Heating rate, cold chamber: 2 K/min
Cooling rate, hot chamber: K/min
Observation window: 355 x 355 mm
Pipe opening: 67 mm
Year of manufacture: 2000
Operating hours: 104,382
Weight: 1000 kg
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Further items – new and used – can be found in our shop! International shipping costs on request!
We make it easier for you to find: "climatic test chamber"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Climatic Test Chamber (14,249)
Search Machineseeker now with more than 2,00,000 used machines:Browse through the most popular machine descriptions:
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month