Used Climatic Test Chamber for sale (16,354)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing

7,009 km
Temperature test chamber
WEISSWT-600/70
Call
Condition: excellent (used), Weiss temperature test chamber
Here we offer a temperature test chamber.
Weiss temperature test chamber water cooled
Technical data:
Test cabinet designation: WT-600/70
Outer dimensions with hinges and door lock
height 1995 mm, width 1090 mm, depth 1660 mm
Outer dimensions without hinges and door lock
height 1995 mm, width 1000 mm, depth 1660 mm
Internal dimensions:
Height 950 mm, width 800 mm, depth 800 mm
Test chamber capacity: approx. 600 liters
cold / heat operation -70°C to 180°C
Temperature change per time
cooling approx. 2.5 K/min
Heating up approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 9.1 kW
Rated current: 19 A
Fuse on site: 32 A slow blow
Permissible test material weight
Total load of grate supports 80kg
test chamber floor 80kg, insert grate 40kg
Refrigerant: R 404A/R23
Weight: 675kg
Type: WT-600/70
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Fodpeiqk Abofx Aabepn
Further questions we can answer on the phone for you.
Listing

7,009 km
Climatic chamber
RS-Simulatoren
Call
Condition: excellent (used), RS Simulators
Here we offer a climatic test chamber.
Water cooled
300 liters
Temperature range from -75 °C to +180 °C
Time deviation +- 0.2 K to +- 0.8 K
Average heating rate: approx. 2.1 K/min
Average cooling rate: approx. 1.2 K/min
Humidity range from 10 % to 98 % rel. humidity
Working climate range
Temperature: 10 °C to 95 °C
Humidity: 25 % to 75 % relative humidity
Dimensions: Width 1000 mm 1800 Height mm 1400 Depth mm
Voltage: 3x400V/N/PE Current: 40A
Refrigerant: R404a / R23
Type: KS 300 / 75
Weight: 630 kg
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Fjdpfx Aaoiivgvjbjpn
Condition: used / used
Scope of delivery: (See pictures)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,009 km
Temperature test chamber spraying device
VötschVBT 03/500 500 Liter -30 bis 80°C
Call
Condition: excellent (used), Vötsch
Type: VBT 03/500
Air-cooled
Temperature test chamber with spray device
Technical description:
Data for temperature tests without water:
Temperature range -30°C to +80°C
Temperature deviation in steady state
according to IEC 60068-3-5 dependent on the test chamber temperature
over time ± 1 K
Temperature change rate according to IEC 60068-3-5
Heating: approx. 2 K/min.
Cooling: approx. 2 K/min.
Data for temperature tests with water
Temperature range +5°C to +80°C
Possible water level -10 mm to 540 mm
Water level = -10 mm
The water level is below the insert grid
Water level = 0 mm
The water level is at the top edge of the insert grid
Data for standard spray device
Number of spray nozzles: 6
Spray volume per nozzle: 0.5 l/min
Data for spray device according to EN 539-2, Method B
Number of spray nozzles: 6
Spray volume per nozzle: 4.5 l/min
Additional flooding nozzles: 2
Spray volume of additional nozzle: 6 l/min
Compressed air consumption: approx. 3 m³/h
Data for water tank with pre-temperature control
Volume: approx. 2000 l
Temperature range for pre-temperature control +5°C to +40°C
Temperature change duration
Cooling of +18°C to +5°C approx. 15 h
Heating from +15°C to +40°C approx. 10 h
Installation and Operation Data:
Test chamber: Width 1120 mm, Depth 840 mm, Height 540 mm
Housing: Width 2700 mm, Depth 1300 mm, Height 1575 mm
Fpjdpfx Aswc Nvgsabsn
Water tank: Width 1100 mm, Depth 800 mm, Height 2200 mm
Plug-ins
1 50 mm diameter plug installed on the left
Test chamber capacity: approx. 500 liters
Refrigerant R-404a
Electrical connection:
Nominal voltage 3/N/PE AC 400V ± 10% 50Hz
Nominal power approx. 26 kW
Nominal current approx. 44.0 A (neutral conductor loaded)
Fuse protection 63 A gG, on-site
Weight approx. 890 kg net
For your safety, please note the following information!
The following steps are carried out on our chambers in advance:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing

7,009 km
Temperature test chamber -20°C...+140°C
TIRATTRE 2001 S
Call
Condition: excellent (used), Here we offer a TIRA temperature test chamber.
TIRA temperature test chamber air-cooled
The chamber has the option for an external test box with external sensor connection
can therefore also be used as an external temperature control unit.
Temperature range -20°C...+140°C
Temperature stability over time ± 0.1°C...± 0.3°C
External dimensions Width 860 mm x depth 1500 mm x height 2100 mm
Test chamber dimensions width 601 mm x depth 545 mm x height 692 mm
Electrical connection 400V +6% / -10% 50Hz 3P+N+PE
Rated current: 10.0 (max.17) A
Fpodponyh T Ssfx Aabjn
Rated power: 5.2 (max.9.0) kW
Net weight: 735 kg
Refrigerant: R404A / R23
Type: TTRE 2001S
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,009 km
Shock test chamber
VötschVT 7012 S3
Call
Condition: excellent (used), Vötsch shock test chamber
Here we offer you a Vötsch shock test chamber.
Water cooled
Temp. range -80C to +220C
Hot chamber +50 to +220
Medium chamber -10 to +90
Cold chamber -80 to +70
Mains voltage 400V +-10% 3/N 50Hz
Rated current 30.5 A
Rated power 13.5 KW
Fpjdpfxen Avcuo Aabjn
Refrigerant VK : R 404A 3.00kg p*: 25bar
Refrigerant TK : R23 15bar p* : 25 bar
Condition: used / used
Type: VT 7012 S3
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Discover more used machines
Listing

7,009 km
Temperature test chamber 270 liters
VötschVTS³ 7027-25 -72°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VTS³ 7027-25
Heraeus Vötsch temperature test chamber, water-cooled
Performance data:
With temperature change rate of 25 K/min
Test chamber dimensions Height 750 mm Width 580 mm Depth 615 mm
External dimensions Height 1775 mm Width 780 mm Depth 1895 mm
Temperature range -72°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5
Temperature homogeneity in space ± 0.5 to ± 2.0
Temperature change rate cooling 25 K/min
Temperature change rate heating 25 K/min
Heat compensation at -20 °C 8000 W
Heat compensation at +20 °C 8000 W
Test volume: 270 liters
2x lateral feed-through ∅ 125 cm
1x side feed-through ∅ 50 cm
Cabinet is water-cooled
Test room lighting:
LED strip 24 V, 6.8 W / 2x halogen bulb 24 V, 50 W
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal power: 26 KW
Rated current: 44 A
Refrigerant: R-452A and R-23
Weight: approx. 980 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
Fpodpfetz Rqmex Aaben
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,009 km
Climate test chamber with humidity
VötschVC³ 0100 0°C bis + 90°C
Call
Condition: excellent (used), Vötsch
Type: VC³ 0100
Vötsch climatic test chamber, air-cooled
Test chamber dimensions: Height 950 mm x width 1100 mm x depth 950 mm
Device dimensions: Height 2000 mm x width 1300 mm x depth 1916 mm
Test chamber 990 liters
Temperature tests:
Minimum temperature -0°C
Maximum temperature +90°C
Temperature change rate cooling 0.2 K/min
Temperature change rate heating 0.5 K/min
Temperature deviation in time ± 0.1 to ± 0.5 K
Temperature homogeneity in space ± 0.5 to ± 1.0 K
Heat compensation at +20 °C 350W
Climatic tests:
Minimum temperature +10°C
Maximum temperature +90°C
Dew point temperature range +4°C to +89.5°C
Humidity range 10 to 98% r. h.
Humidity deviation over time ± 1 to ± 3% r. h.
Temperature deviation temporal ± 0.1 to ± 0.3K
Temperature homogeneity in space ± 0.5 to ± 1.0K
Voltage: 1/N/PE AC 230V±10% 50Hz
Rated power: 2.3 kW
Rated current: 10 A
Fpsdpfx Aotz T D Aeabjn
Refrigerant: R-404A
Weight approx. 1400 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,009 km
Temperature test chamber 1000 liters
CTST-55/1000 Li -50°C bis 100°C
Call
Condition: excellent (used), CTS
Temperature test chamber T-55/1000 Li water-cooled
Temperature range: -50°C to +100°C
Rated voltage: 400V 3/N 50Hz
Rated power: 9.5 kW
Nominal current: 18 A
Compressor: TFH2511Z / TFH2511Z Refrigerant R404A/R23
The type designation of the CTS cabinet series is composed as follows:
z. e.g. type T -55/1000/Li
1) T means: temperature
2) -55 means: lower temperature -55 °C
3) 1000 means: 1000 liter test chamber volume
4) Li means: special equipment for
tests with lithium-ion accumulators
Control:
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoints
Error messages in plain text
Ethernet interface
RS 232 interface
Free switching channels for on-site
test material control
Test room lighting:
energy-efficient, high-intensity LED light strip mounted on the door
Insert grid:
Stainless steel, support surface 970 x 980 mm
Load per shelf max. 35 kg
Total load with max. grating load 100 kg
1a Feed-through NW50
1b Feed-through 2x NW125
1c Entry port 2x Rp 314°
for Minimax
Technical performance data:
Temperature tests:
Temperature range -50°C to +100°C
Temperature deviation ≤ ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat compensation
approx. 4000 W at +20°C
approx. 2200 W at -40°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without heat compensation and without additional equipment.
Options may affect the performance data.
Dimensions:
Test volume 1000 liters
Test chamber dimensions Height, approx. 1000 mm, width, approx. 860 mm, depth, approx. 1100 mm
External dimensions Height, approx. 1950 mm, width, approx. 1270 mm, depth, approx. 1900 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Nominal current 18 A
Rated power 9.5 kW
Protection class IP 54
Sound pressure level < 58 dB(A)
(according to DIN EN ISO 3744
measured at a distance of 1 m from the front)
Mass approx. 1000 kg
Heat output to the installation room 10.4 kW
Cooling unit:
water-cooled, low-noise, fully hermetic
Infinitely variable output adjustment via electronic monitoring and control system,
environmentally friendly refrigerant R404A/R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
Fjdpovba Raofx Aabopn
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,009 km
Vibration temperature test chamber
RS-SimulatorenVTS 600/45 RS -45°C...+180°C
Call
Condition: excellent (used), Here we offer a temperature test cabinet.
Water cooled
Temperature range: -45°C to +180°C
External dimensions: Width 1300 mm x height 2100 mm x depth 2250 mm
Test chamber dimensions: Width 840 mm x height 840 mm x depth 840 mm
Unit part : width 2300 mm x height 2000 mm x depth 1300 mm
Average heating rate: approx. 3 K/min
Fpsdpfxemn Rcio Aabjn
Average cooling rate: approx. 2 K/min
Power consumption: 15 A
Connection voltage: 3x400V/N/PE 50Hz
Weight: approx. 1000 kg
Type: VTS 600/45 RS
Refrigerant: R452
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,009 km
Temperature test chamber
CTSTSR-30/1000
Call
Condition: good (used), CTS
Type: TSR-30/1000
Water-cooled
The type designation of the CTS enclosure series is made up as follows:
z. e.g. type TSR -30/1000
1) T means: Temperature
2) S means: stress screening
3) R means: external conditioning
4) -30 means: lower temperature -30 °C
5) 1000 means: 1000 liter test chamber volume
Technical performance data:
A) TSR-30/1000 basic device without hose connections,
i.e. when used as a stand-alone temperature test chamber
Temperature tests:
Temperature range -40°C to +180°C
Final temperature -45°C
Temperature deviation ≤ ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 6.0 K/min
Cooling 5.0 K/min
Fpsdpfxerivfcj Aabjn
Heat radiation
approx. 5000 W at +20°C
approx. 4200 W at ± 0°C
approx. 3000 W at -20°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment.
Air volume flow
approx.2000m³/h
B) TSR-30/1000 basic unit with hose connections,
for connection to an external test room provided by the customer
Temperature tests:
Temperature range -30°C to +170°C
Temperature deviation ≤ ±0.1 to 0.5 K in time
Average rate of temperature change,
measured with short-circuited circuit
Heating 4.0 K/min
Cooling 4.0 K/min
in the range from +150°C to -10°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment,
measured with short-circuited circuit
Attention: The external test chamber provided by the customer must be absolutely tight and appropriately insulated,
any feed-throughs must be optimally sealed on site.
Dimensions:
Test volume 1000 liters
Air circulation connection Ø 200 mm
Test chamber dimensions Height 900 mm Width 1000 mm Depth 1100 mm
External dimensions Height 1950 mm Width 1270 mm Depth 2245 mm
Technical design:
Refrigeration unit:
water-cooled, low-noise, fully hermetic
Infinitely variable capacity adjustment through
electronic monitoring and control system,
environmentally friendly refrigerant R404A
Door:
Fully opening door, door hinge on the left,
one-handed operation, lockable.
Shelf:
Stainless steel, support surface 970 x 980 mm
Max. load per shelf 35 kg
Total load with max. shelf load 100 kg
Test area lighting: Halogen lamp 20 W, 12 V
Control:
- 32 bit controller
- LCD control panel
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 13.3 kW
Protection class IP 22
Sound pressure level < 60 dB(A)
Weight approx. 850 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,009 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Fjdpfxjun Rv Ns Aabspn
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,009 km
Temperature shock test chamber
Weiss130 Liter TS 130 *
Call
Condition: excellent (used), Here we offer a temperature shock test cabinet.
White Temperature Shock Test Cabinet Air Cooled
Specification:
Temperature range hot chamber +60°C ... +220°C
Temperature range cold chamber -10°C ... -80°C
Change hot/cold chamber 10 s
Temperature constancy ±1 K
Dimensions and other data:
External dimensions: Height 1990 mm
Width ( without and with door hinge ) without....approx. 1820 mm with....approx. 1850 mm
Depth ( without and with test room door ) without....ca. 900 mm with....ca. 1155 mm
Dimensions of the lifting basket ( test chamber ) height 450 mm, width 500 mm, depth 600 mm
volume 130 liters
Test space load max. 20 kg
Fpsdpfelgux Aox Aabjn
Test chamber floor load max. 20 kg
Cooling water pressure min. 2 ... max. 6 bar
Max. Backup fuse 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of unit approx. 65 dB(A)
Cooling cascade water cooled
Connected load: 3/N/PE/AC 400V ±10% 50Hz /14,0 kW
nominal current 26,0 A
Refrigerant R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,009 km
Climate test chamber with humidity 190 liters
VötschVC 7018 -70 bis 180°C
Call
Condition: excellent (used), Vötsch
Type: VC 7018
Vötsch Climatic Test Chamber VC 7018 Water-Cooled
Touch Panel Control Unit
On the touch panel control unit, all control and operating commands can be triggered by simply touching the function symbols.
Fedpfx Aaswgaykjbopn
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Ports
The test chamber is equipped with port holes on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Feedthrough included in standard equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Characteristics for temperature tests:
Temperature range: -70°C to +180°C
Temperature ±0.1 to ±0.5 K
Spatial ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min
Cooling: 2.3 K/min
Characteristics for climatic tests:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% r.h. F.
Temperature deviation over time in the center of the usable space ± 0.1 to ± 0.3 K
Temperature deviation over space ± 0.5 to ± 1.0 K
Temperature gradient 1 to 2 K
Humidity deviation over time in the center of the usable space ± 1 to ± 3 %RH
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10 50Hz
Nominal power: 5.9 kW
Nominal current: 12.0 A
Connection cable: 3.5 m
Fuse protection: 16 A slow-blow, provided by the customer
Refrigerants: R-404A and R-23
Test chamber capacity: approx. 190 liters
Weight: approx. 460 kg net
For your safety, the following information is provided as a buyer!
The following steps are performed on our offered chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing

7,009 km
Climate test chamber with humidity
CTSCS-70/350 350 Liter -70°C /+180°C
Call
Condition: excellent (used), Here we offer you a climatic test chamber.
Water cooled
Test chamber volume 350 liters
Test chamber dimensions: Height 750 mm Width 650 mm Depth 720 mm
Outer dimensions: Height 1800 mm Width 850 mm Depth 1640 mm
Temperature working range:
Temperature range -70°C/+180°C
cooling speed: 3,0 K/min
heating speed: 5,0 K/min
Climate working range:
Temperature range +10°C to +90°C
Humidity range: +10% to 98% r.H.
Dew point range: +5°C to 89.5°C
Temperature deviation ±0.1 - ±0.3 K temporal
Humidity deviation ±1 - ±2 % r.h. temporal up to 90% r.h.
max. ±1 - 3 % r.h. time above 90% r.h.
Fpedpfoi Tw Uvox Aabon
Electrical connection: 400V +6-10 %, 3/N, 50Hz
connected load: 13 kW
rated current: 25,5 A
Refrigerant: R404A / R23
Weight: 650 Kg
Type: CS-70/350
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,009 km
Temperature test chamber
CTST -70/600
Call
Condition: excellent (used), CTS Temperature Test Chamber
Here we offer you a CTS temperature test chamber.
Water cooled
CTS temperature test chamber
Technical performance data:
Temperature working range
temperature range -70°C / +180°C
cooling speed 3,0 K/min
Heating speed 3.5 K/min
Temperature constancy, temporal ≤± 0.3 K.
Dimensions:
Test volume: 600 liters
Test chamber dimensions height, approx. 850 mm, width, approx. 850 mm, depth, approx. 830 mm
External dimensions height, approx. 1900 mm, width, approx. 1120 mm, depth, approx. 1875 mm
Operating data:
Fpjdpoichkvofx Aabon
Electrical connection 400 V +6% -10%, 3/N, 50 Hz
connected load 8,2 kW, 14,2 A
Refrigerant: R404A / R23
Weight: 600 Kg
Type: T-70/600
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,009 km
Temperature test chamber 350 liters
CTSC-40/350 -40/+180°C
Call
Condition: excellent (used), CTS
Type: C-40/350
CTS air-cooled temperature test chamber
Test chamber volume 350 liters
Test chamber dimensions: Height 750 mm Width 650 mm Depth 720 mm
External dimensions: Height 1800 mm Width 850 mm Depth 1640 mm
Design: Floor-standing appliance
Fpjdpfsg Sr Egjx Aabon
Temperature working range:
Temperature range -40°C/+180°C
Cooling speed: 4.0 K/min
Heating speed: 3.0 K/min
Electrical connection: 400V +6-10 %, 3/N, 50Hz
Connected load: 5.5 kW
Rated current: 8.3 A
Condenser refrigeration machine: Air-cooled
Refrigerant: R-404A
Weight: 550 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,009 km
Temperature test chamber
RS-SimulatorenTS 150/45 (50)
Call
Condition: excellent (used), RS simulators
Here we offer a temperature test cabinet.
Fpjdpfx Aaegl Acrobjn
Air cooled
Temperature range: -50°C to +100°C
Test chamber dimensions: Width 520 mm x height 520 mm x depth 500 mm
External dimensions: Width 820 mm x height 1750 mm x depth 1300 mm
current consumption: 13,5 A
Connection voltage: 3x400V/N/PE 50Hz
Weight: approx. 800 kg
Type: TS 150/45 (50)
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, information are reserved!)
Further questions we can answer on the phone for you.
Listing

7,009 km
Temperature test chamber 190 L
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
Call
Condition: excellent (used), Here we offer you a Heraeus Vötsch temperature test chamber.
Heraeus Vötsch temperature test chamber water cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ±0,1 to ±0,5 K
Temperature deviation in time ±0.5 to ±2.0 K
Fpsdohh H Hijpfx Aaben
Temperature change rate cooling 7.5 K/min
Temperature change rate heating 7.5 K/min
Heat compensation +20°C 3000 W
Heat compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 450 mm Height 750 mm
Outer dimensions: Width 870 mm Depth 1280 mm Height 1575 mm
Observation window:
Width 300 mm x height 540 mm
Test chamber volume 190 litres
Rated voltage: 3/N/PE AC, 400 V ±10 %, 50Hz
Rated power: 10.5 kW Rated current: 22 A
Fuse, on-site: 32 A slow-blow
Sound level at 1m distance (free field measurement) < 69dB (A)
lateral feed-through 50 cm / 125 cm
Cabinet is water cooled
Refrigerant: R 404A and R 23
Weight approx. 460 kg
Type: VTS 7018-5
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. function check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer gladly on the phone for you.
Listing

7,009 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), White temperature shock test chamber
Here we offer a temperature shock test chamber.
Weiss Temperature Shock Test Cabinet Water Cooled
Specification:
Temperature range hot chamber +60°C ... +220°C
Temperature range cold chamber -10°C ... -80°C
Change hot/cold chamber 10 s
Temperature constancy ±1 K
Dimensions and other data:
External dimensions: Height 1990 mm
Width ( without and with door hinge ) without....approx. 1820 mm with....approx. 1850 mm
Depth ( without and with test room door ) without....ca. 900 mm with....ca. 1155 mm
Dimensions of the lifting basket ( test chamber ) height 450 mm, width 500 mm, depth 600 mm
volume 130 liters
Test space load max. 20 kg
Test chamber floor load max. 20 kg
Cooling water pressure min. 2 ... max. 6 bar
Max. Backup fuse 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of unit approx. 65 dB(A)
Cooling cascade water cooled
Connected load: 3/N/PE/AC 400V ±10% 50Hz /18.7 kW
nominal current 26,0 A
Refrigerant R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Fpedjlmkn Tjpfx Aabon
Listing

7,009 km
Shock test chamber -80°C to +220°C
VötschVT 7012 S2
Call
Condition: excellent (used), Here we offer Vötsch shock test chamber.
Temperature shock test chamber water cooled
Two-chamber design
Warm chamber:
The temperature control of the warm chamber ranges from +50°C to +220°C
Temperature deviation in time in the center of the chamber ± 1 K
Temperature deviation spatially ± 2 K
Temperature change rate
heating 11 K/min
cold chamber:
the cold chamber from -80°C to +70°C
Temperature deviation temporally in useful space center ± 1 K
temperature deviation spatially ± 2 K
Temperature change rate
heating 2 K/min
cooling 3 K/min
Test chamber volume 125 liters
Temperature range hot chamber +50°C to +220°C
Temperature range cold chamber -80°C to +70°C
Test chamber dimensions width 470mm depth 650mm height 410mm
Outer dimensions width 930mm depth 2115mm height 1970+mm
Feedthrough ∅ 67mm
Fpjdpfxsigg Hnj Aabsn
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant R404A / R23
Weight: 1000 kg
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: VT 7012 S2
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,009 km
Temperature test chamber 335 liters
VötschVTS 7034-5 -70°C bis +180°C
Call
Condition: excellent (used), Heraeus Vötsch temperature test chamber
Here we offer you a Heraeus Vötsch temperature test chamber.
Heraeus Vötsch temperature test chamber water cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6,5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
Outer dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free field measurement) < 69dB (A)
side entry 5,5 cm / 12,5 cm
cabinet is water cooled
Refrigerant: R 452A and R 23
weight approx. 570 kg
Type: VTS 7034-5
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Fpodpfxsir D U Dj Aaben
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Trust Seal
Dealers certified through Machineseeker

Listing

7,009 km
Climate test chamber with humidity 335 liters
WeissWK3-340/40 -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss climate test chamber.
Weiss climate test chamber water-cooled
(refrigerant converted to R-452A)
Temperature test
Volume 335 liters
Test chamber dimensions:
Test chamber dimensions: Height 750 mm, width 580 mm, depth 765 mm
External dimensions: Height 1775 mm, width 870 mm, depth 1600 mm
Minimum temperature -42°C
Maximum temperature +180°C
Temperature change rate, cooling 4 K/min
Temperature change rate, heating 3.2 K/min
Temperature deviation, temporal ± 0.1 to ± 0.5 K
Temperature homogeneity, spatial ± 0.5 to ±1.5 K
Climate test:
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range 10 to 98% r.h.
Fpedpfx Aajq U Sdcobon
Temperature deviation, temporal ± 0.1 to ± 0.3 K
Temperature homogeneity, spatial ± 0.5 to ±1 K
Humidity deviation, temporal ± 1 to ± 3 % r.h.
Voltage: 3/N/PE AC 400V±10% 50Hz
Rated power 4.1 kW Rated current: 14 A
Refrigerant: R-452A
Type: WK3-340/40
Weight Approx. 515 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,009 km
Temperature shock test chamber
EspecTSD-100 -70 °C bis +200 °C
Call
Condition: excellent (used), Here we offer a temperature shock test chamber.
with 100 liters of usable space for larger test specimens up to 30 kg.
Compliant with all current international standards.
Fpodpfxen Smtms Aabon
Water cooled
Temperature range hot chamber: +60 °C to +200 °C
Temperature range cold chamber: -70 °C to 0 °C
Test chamber dimensions: 710 x 345 x 410 (W x H x D) in mm
External dimensions: 1100 x 1885 x 1965 (W x H x D) in mm
Water-cooled refrigeration unit
Program control via touch panel
Automatic defrost
Overtemperature protection
Operating hours counter
Mobile version
2 test material baskets made of stainless steel
Cable gland Ø 100 mm
Refrigerant: 3 kg R404A 1kg R23
Power supply: 400V 3Ph 50Hz
Max. Current consumption: 32A
Type: TSD-100
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,009 km
Environmental test chamber -70°C - +180°C Humidity
ThermotronSM-8-8200
Call
Condition: excellent (used), Here we offer you Thermotron environmental test chamber.
Thermotron Environmental Test Chamber Water Cooled
Working volume: 227 liters
Temperature uniformity: All models 0.7°C
Temperature range: -70°C to + 180°C
Temperature control tolerance: All models 0.3°C
Shipping weight: approx 400 kg
Internal dimensions width 610 mm x depth 610 mm x height 610 mm
Outer dimensions width 890 mm x depth 1240 mm x height 1850 mm
Humidity range: All models 10% to 98% RH
Humidity control: All models 2.5% RH
Heating capacity in minutes -65º to 71ºC: 17
Heating power in minutes -65º to 180ºC: 43
Heating power in minutes -40º to 85ºC: 16
Electrical requirements in full load amplifiers 230/3/60: 19
Electrical requirements in full load amplifiers 230/1/60: 25
Fedpfx Aaemhfr Isbopn
Electrical requirements in full power amplifiers 220/1/50: 27
Cooling capacity in minutes 85º to -40ºC: 32
Cooling capacity in minutes 71º to -65ºC: 54
Cooling capacity in minutes 180º to -65ºC: 72
Compressor size: (2) -2 Hp
Operating voltage: 400V 16.7 A
Type: SM-8-8200
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,009 km
Temperature shock test chamber
EspecTSD-100
Call
Condition: good (used), Espec
Type: TSD-100
Fodpfxot I S Rhj Aabopn
100 liters of usable space for larger test specimens up to 30 kg.
Complies with all current international standards.
Water-cooled
Temperature range hot chamber: +60 °C to +200 °C
Cold chamber temperature range: -70 °C to 0 °C
Test chamber dimensions: 710 x 345 x 410 (W x H x D) in mm
External dimensions: 1100 x 1885 x 1965 (W x H x D) in mm
Water-cooled refrigeration unit
Program control via touch panel
Automatic defrosting
Overtemperature protection
Operating hours counter
Mobile version
2 stainless steel test baskets
Cable gland Ø 100 mm
Refrigerant: 3 kg R404A 1kg R23
Power supply: 400V 3Ph 50Hz
Max. Current consumption: 32A
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
We make it easier for you to find: "climatic test chamber"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Climatic Test Chamber (16,354)
Search Machineseeker now with more than 2,00,000 used machines:Browse through the most popular machine descriptions:
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month