Used Climatic Test Chamber for sale (16,295)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing

7,009 km
Temperature test chamber 600 liters
CTST-70/600/S -70°C bis 180°C
Call
Condition: excellent (used), CTS
Type: T-70/600/S
Water-cooled temperature test chamber
Control system:
- 32 bit controller
- LCD control panel
- Digital display of set and actual values
- Numerical input of setpoints
- Error messages in plain text
- RS 232 interface
- Free switching channels for on-site test material control
Technical performance data
Temperature tests:
Temperature range -70 °C to +180 °C
Temperature deviation ±0.1 to ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat radiation
approx. 2500 W at +20°C
approx. 2500 W at + 0°C
approx. 1800 W at -40°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions Height, approx. 850 mm, width, approx. 850 mm, depth, approx. 830 mm
External dimensions Height, approx. 1900 mm, width, approx. 1120 mm, depth, approx. 1875 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 8.8 kW
Nominal current 14.8 A
Protection class IP 22
Weight approx. 700 kg
Refrigerant: R404A / R23
Weight: 600 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
Gsdpfx Aaeu U Ixmsbekc
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,016 km
Solar cells Photovoltaic Test chamber
Parker Hannifin GmbHVertical Light Stack Module
Call
Condition: like new (used), Year of construction: 2012, Parker Engineering & Design Vertical Light Stack Module
For testing solar modules Photovoltaic modules
Electrical and mechanical safety testing
Support for product development, design and quality control
Detection of potential problems during development
Quality and safety control
Endurance test stand
Gksdpfx Aaeh Rvh Soboc
Temperature control
Mobile on rollers
Entry pockets for forklift trucks
400 VAC, 3.PH, 50 AMP
IR. 10,000 amp
Year 2012
Weight 1400 kg
Further test equipment - new and used - you will find in our shop!
International shipping costs on request!
Listing

7,009 km
Temperature shock test chamber
EspecTSD-100
Call
Condition: good (used), Espec
Type: TSD-100
100 liters of usable space for larger test specimens up to 30 kg.
Complies with all current international standards.
Water-cooled
Temperature range hot chamber: +60 °C to +200 °C
Cold chamber temperature range: -70 °C to 0 °C
Test chamber dimensions: 710 x 345 x 410 (W x H x D) in mm
External dimensions: 1100 x 1885 x 1965 (W x H x D) in mm
Water-cooled refrigeration unit
Program control via touch panel
Gjdpfst I S Rhsx Aabjkc
Automatic defrosting
Overtemperature protection
Operating hours counter
Mobile version
2 stainless steel test baskets
Cable gland Ø 100 mm
Refrigerant: 3 kg R404A 1kg R23
Power supply: 400V 3Ph 50Hz
Max. Current consumption: 32A
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing

7,016 km
Climate test chamber Temperature test
Andreas SchmidVKT 3.000 /-40/+130
Call
Condition: good (used), Year of construction: 2005, Andreas Schmid Climatic Test Chamber -40°C to +130°C
Manufacturer: Andreas Schmid
Type: VKT 3.000 /-40/+130
Temp. Range: -40°C to +130°C
Program Controller: Stange SE - 502
Line Voltage: 400 V
Rated Current: 32 A
Gsdpfxsuuibkj Aabskc
Refrigerant: R 404 A / R 23
Year of Manufacture: 2005
External Dimensions: W 1600 x D 800 x H 2430 mm
TK-16
Find more items - new and used - in our shop!
International shipping costs on request!
Listing

7,009 km
Climate test chamber with humidity 335 liters
WeissWK3-340/40 -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss climate test chamber.
Weiss climate test chamber water-cooled
(refrigerant converted to R-452A)
Gsdpfxeq U Sdce Aabokc
Temperature test
Volume 335 liters
Test chamber dimensions:
Test chamber dimensions: Height 750 mm, width 580 mm, depth 765 mm
External dimensions: Height 1775 mm, width 870 mm, depth 1600 mm
Minimum temperature -42°C
Maximum temperature +180°C
Temperature change rate, cooling 4 K/min
Temperature change rate, heating 3.2 K/min
Temperature deviation, temporal ± 0.1 to ± 0.5 K
Temperature homogeneity, spatial ± 0.5 to ±1.5 K
Climate test:
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range 10 to 98% r.h.
Temperature deviation, temporal ± 0.1 to ± 0.3 K
Temperature homogeneity, spatial ± 0.5 to ±1 K
Humidity deviation, temporal ± 1 to ± 3 % r.h.
Voltage: 3/N/PE AC 400V±10% 50Hz
Rated power 4.1 kW Rated current: 14 A
Refrigerant: R-452A
Type: WK3-340/40
Weight Approx. 515 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Discover more used machines
Listing

7,016 km
Temperature shock chamber climate test
NemaNTS 3000 / 2S
Call
Year of construction: 2000, condition: good (used), Nema Temperature Shock Test Chamber -40°C to +120°C
Manufacturer: Nema
Gkjdeuuiayspfx Aabjc
Type: NTS 3000 / 2S
Temp. Range: -40°C to +120°C
Line Voltage: 400 V
Rated Current: 88 A
Rated Power: 55 kW
Refrigerant: R 404 A
Year of Manufacture: 2000
Weight: 5000 kg
External Dimensions: W 4000 x D 2760 x H 3450 mm
Chamber: W 3000 x D 1250 x H 1610 mm
TS-06
Find more items - new and used - in our shop!
International shipping costs upon request!
Listing

7,009 km
Temperature test chamber 600 liters
CTST-70/600/S 70°C bis 180°C
Call
Condition: good (used), CTS
Type: T-70/600/S
Temperature test chamber water-cooled
Refrigerant: Converted to R-452A
Control:
- 32 bit controller
- LCD control panel
- Digital display of setpoints and actual values
- Numerical input of setpoints
- Error messages in plain text
- RS 232 interface
- Free switching channels for on-site test material control
Technical performance data
Temperature tests:
Temperature range -70 °C to +180 °C
Temperature deviation ±0.1 to ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat radiation
approx. 2500 W at +20°C
approx. 2500 W at + 0°C
approx. 1800 W at -40°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions Height, approx. 850 mm, width, approx. 850 mm, depth, approx. 830 mm
External dimensions Height, approx. 1900 mm, width, approx. 1120 mm, depth, approx. 1875 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 8.8 kW
Nominal current 14.8 A
Protection class IP 22
Weight approx. 700 kg
Refrigerant: R-452A / R23
Weight: 700 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
Gkjdpfx Ajvitmdeabjc
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,016 km
Corrosion test chamber
NemaNSN 300
Call
Condition: good (used), Year of construction: 1999, Nema corrosion test chamber for salt spray tests
Manufacturer: Nema
Type: NSN 300
Rated voltage: 400 V
Rated current: 11 A
Compressed air: 8-10 bar
Air consumption: 6 Nm³/h
Humidifier: 0.5 l/h
Water pressure: 2-8 bar
Power consumption: 5.6 kW
Gedpfxeu Ecrxo Aabskc
Salt solution: NaCl: 50 +- 5.6 kW
External dimensions (WxDxH) 3200 x 1200 x 1900 mm
Internal dimensions of the test chamber (WxDxH) 3100 x 1000 x 880 mm
Weight: 390 kg
Further items in other sizes - new and used - can be found in our store!
International shipping costs on request!
Listing

7,009 km
Temperature shock test chamber
WeissTS 130
Call
Condition: used, White
Type: TS 130
Temperature shock test chamber water-cooled
Specification:
Temperature range hot chamber +60°C … +220°C
Temperature range cold chamber -10°C … -80°C
Gjdpfxsvwckhe Aabjkc
Switch between hot and cold chambers 10 sec.
Temperature stability ±1 K
Dimensions and other data:
External dimensions: Height 1990 mm
Width (without and with door hinge) without....approx. 1820 mm with....approx. 1850 mm
Depth (without and with test chamber door) without....approx. 900 mm with....approx. 1155 mm
Dimensions of the lifting basket (test room) height 450 mm, width 500 mm, depth 600 mm
Volume 130 liters
Test room load max. 20 kg
Test room floor load max. 20 kg
Cooling water pressure min. 2 ... max. 6 bar
Max. fuse 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of the device approx. 65 dB(A)
Water-cooled cooling cascade
Connection values: 3/N/PE/AC 400V ±10% 50Hz /14.0 kW
Rated current 26.0 A
Refrigerant R 404A / R23
Weight: approx. 950 kg
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
More We will be happy to answer any questions you may have over the phone.
Listing

7,016 km
Climate test chamber Environmental test
EspecPR-3KP
Call
Operating hours: 56,530 h, condition: good (used), Espec PR-3KP Climatic Test Chamber -20 to +100 °C
Features:
Manufacturer: Espec
Type: PR-3KP
Temperature range: -20 to +100 °C
Humidity: 20 to 98% RH
Refrigerant R-404A: CFC-free – ozone-preserving
Operating hours: 56,530
Dimensions:
External dimensions: HxWxD = 1680 x 1050 x 1200 mm
Chamber dimensions: HxWxD = 850 x 600 x 800 mm
Gkedpfor H Dr Nex Aaboc
Other items in other sizes – new and used – can be found in our shop!
International shipping costs upon request!
Listing

7,009 km
Shock test chamber +50 - 220°C -80 - +70°C
VötschVT 7012 S2 (6603)
Call
Condition: excellent (used), Here we offer Vötsch shock test chamber.
Temperature shock test chamber water cooled
Two-chamber design
Gkodpfx Ajn Arc Aeaboc
Warm chamber:
The temperature control of the warm chamber ranges from +50°C to +220°C
Temperature deviation in time in the center of the chamber ± 1 K
Temperature deviation spatially ± 2 K
Temperature change rate
heating 11 K/min
cold chamber:
the cold chamber from -80°C to +70°C
Temperature deviation temporally in useful space center ± 1 K
temperature deviation spatially ± 2 K
Temperature change rate
heating 2 K/min
cooling 3 K/min
Test chamber volume 125 liters
Temperature range hot chamber +50°C to +220°C
Temperature range cold chamber -80°C to +70°C
Test chamber dimensions Width 470 mm Depth 650 mm Height 410 mm
External dimensions Width 930 mm Depth 2115 mm Height 1970 mm
Feedthrough ∅ 67mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V ±10% 50Hz
Refrigerant R404A / R23
Weight: 1000 kg
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: VT 7012 S2
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,009 km
Temperature test chamber
VötschVT³ 4150/S
Call
Condition: excellent (used), Vötsch
Type: VT³ 4150/S
Gkodpfx Aaoinuhgebec
Vötsch temperature test chamber
Water-cooled
Rated voltage: 3/N/PE AC, 400 V ±10 %, 50 Hz
Rated power: 11.5 kW Rated current: 22.0 A
Rate of change: cooling approx. 3.5 K/min.
Rate of change: Heating approx. 4 K/min.
Temperature test
Temperature range -40°C to + 180°C
Display plan
External dimensions: W x D x H approx. 1390 x 2380 x 1995 mm
Test chamber dimensions: W x D x H approx. 1100 x 1475 x 950 mm
Weight approx. 1020 kg / 1540 liters
Refrigerant R 404A
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,009 km
Temperature test chamber 680 liters
Heraeus VötschVLM 3068/S -30 °C bis +125 °C
Call
Year of construction: 2010, condition: excellent (used), Here we offer you a Heraeus Vötsch temperature test chamber.
Vötsch temperature test chamber VLM 3068/S air-cooled
(building material test chambers loaded from above)
Control panel
The control panel is mounted on a console on the temperature test chamber. By
control and operating commands can be triggered by simply touching the function symbols.
can be triggered. The operating instructions for the control panel are enclosed
Main switch
The main switch is located at the front of the temperature test chamber.
Air treatment room
The air treatment room is located in the test room
and contains the components required for temperature control.
In the air treatment room, the air is tempered (cooling/heating) and circulated by the test room fan.
circulated by the test room fan. The air is sucked in at the center of the side wall and
enters the test chamber again via the air baffles on the long sides.
Feed-throughs
The temperature test chamber can optionally be equipped with feed-throughs. Through these
can be used to route cables and test equipment into the test chamber.
Entry port front 2 x 82 mm ∅ rear 1 x 85 mm ∅
Internal dimensions Width 2000 mm Depth 570 mm Height 600 mm
External dimensions Width 3000 mm Depth 870 mm Height 1060 mm
Technical data:
Data for mechanical load:
Max. load with test material
Test area floor
(evenly distributed over the surface) 600 kg
Point load 50 kg
Data for temperature tests:
Temperature range -30 °C to +125 °C
Temperature deviation over time in the center of the usable space ±1 K
Temperature change rate
Heating approx. 1 K/min
Cooling approx. 2 K/min
Data for operation:
Nominal voltage 3/N / PE AC 400 V ±10% 50 Hz
Rated power 3 kW Rated current 9 A
Customer fuse 16A slow-blow
Temperature test chamber VLM 3068/S
Test chamber volume approx. 680 l
Weight approx. 700 kg
Refrigerant: R-404A
Noise measurement Sound pressure level approx. 68 dB(A)
Type: VLM 3068/S
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Gkodperbiyfofx Aabjc
Listing

7,009 km
Climatic chamber 8m³ with humidity #1
EspecEWSH282-4CW -65°C bis 150°C
Call
Condition: excellent (used), Espec
Type: EWSH282-4CW
Temperature and Climatic Test Chamber
Water-cooled
Temperature range: -65°C to 150°C
Temperature fluctuation: ±1°C
Temperature gradient: ±2°C
Temperature change rate
Heating: approx. 2.5K/min
Cooling: approx. 2.5K/min
Humidity range: 20 to 95°C RH
Humidity fluctuation: ±5% RH
Gkedekl Axtspfx Aabsc
Humidity gradient: ±5% RH
Dimensions
External dimensions: Width 2324 mm, Depth 4006 mm, Height 2889 mm
Internal dimensions: Width 1829 mm, Depth 1829 mm, Height 2388 mm
Voltage: 8.0 m³
Weight: approx. 3,600 kg
Power supply: 400V, 3PH, 50HZ (+5% / 10%)
Controller: Espec SCP-220
Refrigerants: R-404a and R-508b
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing

7,009 km
Temperature test chamber 1540 liters
VötschVT³ 4150 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VT³ 4150
Vötsch temperature test chamber
Air-cooled
Rated voltage: 3/N/PE AC, 400 V ±10 %, 50 Hz
Rated power: 11.5 kW Rated current: 22.0 A
Rate of change: Cooling approx. 3.5 K/min.
Rate of change: Heating approx. 4 K/min.
Temperature test
Temperature range -40°C to + 180°C
Gsdou Nh Rbjpfx Aabekc
Display plan
External dimensions: W x D x H approx. 1390 x 2380 x 1995 mm
Test chamber dimensions: W x D x H approx. 1100 x 1475 x 950 mm
Weight approx. 1020 kg / 1540 liters
Refrigerant R 404A
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,009 km
Climate test chamber XXL 3300 liters
VötschVC 7330/S -70°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VC 7330/S
Water-cooled climate chamber
Room volume: 3300 liters
Gjdpfx Aeu Au Ersabjkc
Data for temperature tests:
Temperature range: -70°C to +180°C
Spatial temperature deviation: ± 1 to ± 2 K (corresponds to temperature gradient) (2 to 4)
Temperature fluctuation over time in the center of the usable space: ± 0.5 - 1 K
Temperature change rate (according to IEC 60068-3-5)
Heating: 1.5 K/min
Cooling: 1.5 K/min
Data for climate tests:
Temperature range: +10 to +90°C
Humidity range: 10% RH up to 98% RH
Temperature fluctuation over time ± 0.2 to -0.5 K
Humidity fluctuation over time ± 1% RH to ± 3% RH
Dew point range +5°C to +89°C
Mechanical load data:
of the test chamber floor 150 kg
Maximum chamber floor load 250 kg
Dimensions of the test chamber: Width 2000 mm x Depth 1150 mm x Height 1510 mm
External dimensions: Width 4000 mm x Depth 1450 mm x Height 2100 mm
Operating data:
Test chamber lighting: Halogen bulb 12 V, 20 W
Rated voltage: 3/N/PE AC 400V±10% 50Hz
Rated power 15 kW, Rated current 34 A
External control via the RS 232 interface is of course possible.
Refrigerant: R404A / R23
Weight: 1550 kg
For your safety, the following information is provided as a buyer!
The following steps are performed on our chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing

7,009 km
Temperature test chamber
CTSTS -70/600-13
Call
Condition: used, CTS
Type: TS -70/600-13
Temperature test chamber, water-cooled
Type series: TS -70/600-13
Control system:
Gkodpfx Asvcyawsaboc
- 32 bit controller
- LCD control panel
- Digital display of setpoints and actual values
- Numerical input of setpoint values
- Error messages in plain text
- RS 232 interface
- Free switching channels for on-site test material control
Test chamber volume: 600 liters
Test chamber dimensions: Height approx. 730 mm, width approx. 850 mm, depth approx. 830 mm
External dimensions: Height approx. 2250 mm, width approx. 1300 mm, depth approx. 2475 mm
Temperature range: -70 to +180°C
Heating speed: 13 K/min at -40°C to +120°C
Cooling speed: 13 K/min at 120°C to -40°C
Temperature deviation: ± 0.1K temporal, ± 0.5 K spatial
Electrical connection 400/3P/N/PE
Nominal power: approx. 27.8 kW
Nominal current: approx. 44.1 A
Compressor: 4TC-8.2Y/4PC-10.2Y
Refrigerant: R-404 A / R-23
Weight: 1350 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,009 km
Temperature test chamber 600 liters
CTST-70/600 -70°C bis 180°C
Call
Condition: excellent (used), CTS
Climatic test chamber T-70/600 water-cooled
Temperature range: -70°C to +180°C
Rated voltage: 400V 3/N PE 50 Hz
Rated power: 6.7 kW
Rated current: 10.2 A
Godpfx Aaevaxq Nobskc
Compressor: TFH2480Z/TFH2511Z Refrigerant R23/R404A
Control system:
-Microprocessor-controlled control and monitoring system
Simple, user-friendly terminal built into the door.
-Digital temperature setpoint and actual value display
Simple variation via +/- button
-Digital input for temperature in °C
-PLC compatible
-Up to 100 test programs possible
-RS 232 interface
-2 free switching channels for on-site
test material control
Insert grid:
Stainless steel, contact surface 820 x 710 mm
Load per grid max. 35 kg
Total load with max. grid configuration 100 kg
Cooling unit:
Water-cooled, low-noise, fully hermetic Infinitely variable power adjustment
through electronic monitoring and control system,
environmentally friendly refrigerant R404A/R23
Temperature tests:
Temperature range -70 °C to+ 180 °C
Temperature deviation ±0.1 to 10.3 K in time
Rate of temperature change
according to DIN 50 011, part 12 measured in the center of the test room
Heating 2.5 K/min
Cooling 2 K/min
Heat radiation max. 1500 W at +20°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400 V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions 850 x 830 x 850 mm (W x Dx H)
External dimensions 1050 x 1850 x 1900 mm (W x DxH)
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 6.7 kW
Rated current: 10.2 A
Protection class IP 22
Condensate drain unpressurized R 1/2" internal thread
Sound pressure level < 62 dB(A)
Weight approx. 400 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,009 km
Climatic chamber
VötschVC³ 4100
Call
Condition: excellent (used), Vötsch climatic test chamber
Here we offer a Vötsch climate test chamber.
Designation VC³ 4100 Air-cooled
With temperature change rate of 3 K/min
Test chamber dimensions: Height 950 mm x width 1100 mm x depth 950 mm
Device dimensions: Height 2000 mm x width 1300 mm x depth 1916 mm
Volume: 990 liters
Feed-through: Ø 125 mm Ø 50 mm
Data for temperature tests:
Temperature range -42°C to +180°C
Temperature deviation in time ± 0.1 to ± 0.5 K
Temperature homogeneity in space ± 0.5 to ± 1.5 K
Godpfoqnutmjx Aabokc
Rate of temperature change:
Heating 4.0 K/min
Cooling 3.0 K/min
max. heat compensation at +20°C 4500 Watt
Data for climate tests
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range 10 to 98% r. h.
Temperature deviation temporal ± 0.1 to ± 0.3 K
Spatial temperature homogeneity ± 0.5 to ± 1.0 K
Humidity deviation temporal ± 1 to ± 3% r. h.
Heat compensation max. 500 W
Voltage: 3/N/PE AC 400V ± 10% 50Hz
Rated power: 11.5 kW
Rated current: 22.0 A
Refrigerant: R-404 A
Weight approx. 840 kg
Type: VC³ 4100
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after a successful check, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,009 km
Climate test chamber with humidity 1000 liters
CTSC-40/1000 -40°C bis +180°C
Call
Condition: excellent (used), CTS
Type: C-40/1000
CTS climatic test chamber
Condenser chiller air-cooled
Control:
32 bit controller
LCD control panel
Digital display of setpoints and actual values
Numerical input of setpoints
Error messages in plain text
RS 232 interface
Free switching channels for on-site test material control
Temperature test:
Temperature range: -40°C to +180°C
Godpfxsru Dzuo Aabskc
Temperature change rate
Heating speed 2.0 K/min
Cooling rate 2.5 K/min
Temperature deviation ± 0.1 to ± 0.3 K in time
Heat radiation:
approx. 2500 W at +20°C
approx. 2500 W at ± 0°C
approx. 1500 W at -20°C
Climate Working range:
Temperature range +10°C to +95°C
Humidity range 10 to 98% r.h.
Dew point range I +7 to +94°C
Dew point range II -10 to +7°C
Temperature deviation ± 0.1 to ± 0.3 K in time
Humidity constancy I, temporal ± 0.5 to ± 1.5 % r.h.
Humidity constancy II, temporal ± 1 to ± 3 % r.h.
Panorama window 570 x 710 mm
Test chamber dimensions Width 1000 mm Depth 1100 mm Height 900 mm
External dimensions Width 1270 mm Depth 2220 mm Height 1950 mm
Test chamber volume 1000 liters
Pipe feed-throughs, ø 50
Electrical connection: 400 V +6/-10% 3/N, PE 50 Hz
Connected load: 8.4 kW Rated current: 12.4 A
Refrigerant: R-404A
Weight: 800 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,009 km
Climate test chamber with humidity 800 liters
EspecEGNX28-6CWL -70 bis +180°C
Call
Condition: excellent (used), Espec
Type: EGNX28-6CWL
Espec climate test chamber water-cooled
Climate test chamber N series
Temperature range -70 to +180°C
Temperature change rate
Heating 10 °K/min
Cooling 5.5 °K/min
Humidity range 10 to 95% RH according to diagram
Internal dimensions W x H x D in mm 1000 x 1000 x 800
External dimensions W x H x D in mm 1205 x 1930 x 1960
Usable space volume 800 liters
Cooling capacity 3.6 kW at -50 °C
Heating system 10 kW
Godpfx Asv Duuxjabjkc
Refrigerant R-404A
Refrigerant R- 508A
Power supply:
AC 400 V 3-phase 50/60Hz 38A
Weight: approx. 695 kg
For your safety as a buyer, the following information!
The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Trust Seal
Dealers certified through Machineseeker

Listing

7,009 km
Climate test chamber with humidity
Weiss -72°C bis +180°CWK3-340/70
Call
Condition: excellent (used), Weiss
Type: WK3-340/70
Weiss Air-Cooled Climatic Test Chamber
Touch Panel Control Unit
All control and operating commands can be triggered by simply touching the function symbols on the touch panel control unit.
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Plug-ins
The test chamber is equipped with plug-ins on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Penetration included in standard equipment
R1: NW 125 mm
L1: NW 85 mm
Volume 335 liters
Test chamber dimensions:
Gsdov Sr Hzjpfx Aabskc
Test chamber dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Data for temperature tests:
Minimum temperature -72°C
Maximum temperature +180°C
Temperature deviation, temporal ± 0.1 to ± 0.5 K
Temperature homogeneity, spatial ± 0.5 to ± 1.5 K
Temperature change rate, cooling 3 K/min
Temperature change rate, heating 3 K/min
Data for climatic tests:
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range: 10 to 98% RH
Temperature deviation, over time: ± 0.1 to ± 0.3 K
Temperature homogeneity, spatial: ± 0.5 to ± 1 K
Humidity deviation, over time: ± 1 to ± 3% RH
Operating data:
Test room lighting: 2 x 24V, 50W halogen bulb
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 16 A
Nominal power: 4.9 kW
Fuse: 16 A slow-blow (on-site)
Refrigerant: R-452A/R23
Weight: Approx. 585 kg
For your safety, the following information is provided as a buyer!
The following steps are performed on our chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing

7,009 km
Temperature test chamber ex protected
CTST-30/950 Ex/I
Call
Year of construction: 2011, condition: excellent (used), CTS
Type: T-30/950 Ex/I
CTS Temperature Test Chamber, Explosion-Proof
Control – 32-bit controller
LCD control panel
Digital display for set and actual values
Numerical input of set values
Error messages in plain text
RS 232 interface
Free switching channels for product-side test specimen activation
Gkjdsihb Amspfx Aabec
Temperature Testing:
Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
Heating: 2 K/min
Cooling: 1.5 K/min down to -10°C
Thermal radiation: approx. 1000 W at +20°C
approx. 200 W at -25°C
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with a large flow rate of N2 until the
o2 content drops below 3%. Then, it switches to a base flow amount (approx. 10% of the large flow rate).
The nitrogen flow for the base amount is measured and displayed using a flowmeter and monitored via a limit switch.
O2 monitoring continuously extracts gas from the test chamber via a flame arrestor and passes it over an O2 sensor which checks the residual oxygen content of the extracted air.
Afterwards, the gas is returned to the test chamber via a second flame arrestor.
The extraction pump is monitored by a volumetric flow meter. Additional details can be found in the Dräger user manual in the appendix.
The gas system is currently deactivated!
All technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without irradiation, and without additional equipment.
Dimensions:
Test chamber volume: 950 liters
Test chamber dimensions: Height approx. 700 mm / Width approx. 900 mm / Depth approx. 1500 mm
External dimensions: Height approx. 2400 mm / Width approx. 1270 mm / Depth approx. 3125 mm
Operating data:
Electrical connection: 400V +6/-10 %, 3/N, 50 Hz
Nominal power: 21.6 kW
Rated current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, R 1/2" inner thread
Sound pressure level:
Listing

7,009 km
Climate test chamber Temp. -70°C to +180°C
Vötsch 190 LiterVCS 7018-5
Call
Condition: excellent (used), Heraeus Vötsch
Type: VCS 7018-5
Climatic Test Chamber with Humidity Control, Water-Cooled
Test Chamber Dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing Dimensions: Width 870 mm x Depth 1280 mm x Height 1775 mm
Characteristics for Temperature Tests:
Temperature Range: -70°C to +180°C
Temperature Range: ± 0.1 to ± 0.5 K
Spatial Range: ± 0.5 to ± 2.0 K
Temperature Gradient: 1 to 4 K
Temperature Rate of Change according to IEC 60068-3-5
Heating: 7.5 K/min
Cooling: 7.5 K/min
Characteristic values for climatic tests:
Temperature range +10 to +95°C
Humidity range: 10 to 98% RH
Gkjdov N Hc Eopfx Aabjc
Temperature deviation over time: ± 0.1 to ± 0.3 K
Temperature deviation over space: ± 0.5 to ± 1 K
Temperature gradient: 1 to 2 K
Humidity fluctuation over time: ± 1 to ± 3% RH F.
Dew point range -3 to +94 °C
Electrical connection:
Nominal voltage: 3/N/PE AC 400V±10% 50Hz
Nominal power: 10 kW
Nominal current: 21 A
Fuse protection: 32 A slow-blow, provided by the customer
Refrigerant: R-404A / R-23
Test chamber volume: approx. 190 liters
Weight: approx. 460 kg
For your safety, please note the following information!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications!)
We are happy to answer any further questions you may have over the phone.
Listing

7,009 km
Climate test chamber, 6000 litres (6 m³)
CTSCW-60/6 -60°C bis +120°C
Call
Condition: excellent (used), CTS CW-60/6 – Climate Test Chamber, Water-cooled
The CW-60/6 from CTS GmbH (Climatic Test Systems) is a medium-sized, walk-in or drive-in climate chamber designed for conducting temperature and humidity tests on multiple test specimens simultaneously.
Device Description
The climate test chamber allows for the testing of functional or material properties of a specimen under the influence of temperature and humidity.
Efficient air circulation with a high recirculation volume ensures optimal heat transfer to the test specimen.
The air conditioning compartment is located at the rear of the interior section.
The technical assemblies are housed in a separate frame behind the unit, allowing easy access.
The control system is housed in a separate control cabinet.
The operating panel is integrated into the control cabinet door.
For dehumidification, the test chamber is equipped with a self-regenerating compressed air dryer.
The test chamber can be purged with fresh air via a fan.
Technical Performance Data:
Temperature Testing:
Temperature range: -60 °C to +120 °C
Temperature deviation: ±0.5 to 1 K over time
Temperature change rate linear with test specimen,
measured in supply air:
Heating: 1 K/min from -40 °C to +80 °C
Cooling: 1 K/min from +80 °C to -40 °C
Test specimen: 700 kg steel
Thermal radiation:
2 kW during temperature change
5 kW steady-state at -40 °C
Climate Testing:
Temperature range: +10 °C to +95 °C
Humidity range: 10% to 85% RH
In dew point mode: +5 °C to +89 °C
Temperature deviation: ±0.5 K over time
Humidity deviation: ±1 to ±3% RH over time
Technical data refer to an ambient temperature of +25 °C,
nominal voltage 400 V, without test specimen, without irradiation,
and without additional equipment.
Dimensions:
Internal dimensions (test chamber / usable space):
Volume: approx. 6,000 liters (6 m³)
Internal dimensions (approx.): Height: ~2000 mm Width: ~2000 mm Depth: ~1500 mm
(slight variations possible depending on configuration)
External dimensions: Height: ~2300–2500 mm Width: ~2400–2600 mm Depth: ~1800–2200 mm
(depending on door, frame, accessories, etc.)
Operating Data:
Electrical connection: 400 V +6/-10%, 3/N, PE, 50 Hz
Rated power: 44.4 kW (incl. 5 sockets)
Rated current: 84.7 A
Godpfx Aajwu Epgebjkc
Protection class: IP54
Technical Design:
Cooling unit:
water-cooled, low noise, semi-hermetic,
stepless power adjustment via electronic
monitoring and control system,
environmentally friendly refrigerants R23 / R404A
Notes
Inspection possible by appointment (46325 Borken)
Shipping by freight carrier possible – costs & organization upon request
Scope of delivery: (see image)
(Specifications subject to change and error!)
For further questions, please contact us by phone.
We make it easier for you to find: "climatic test chamber"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Climatic Test Chamber (16,295)
Search Machineseeker now with more than 2,00,000 used machines:Browse through the most popular machine descriptions:
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month